Circuit Breaker, frame only
Transcripción
Circuit Breaker, frame only
s Item: Circuit Breaker, frame only Interruptor caja base Disjoncteur de base U.S. Cat. No. Euro Order No. NDG _F150 HDG_F150 LDG_F150 NFG _F250 HFG _F250 LFG _F250 3VL2015-1RA_0-0AA0 3VL2015-2RA_0-0AA0 3VL2015-3RA_0-0AA0 3VL3025-1RA_0-0AA0 3VL3025-2RA_0-0AA0 3VL3025-3RA_0-0AA0 For Use With Frame DG, FG Para Usar Con Caja Base DG, FG Installation Instructions / Instructivo de Instalación Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Use only with Siemens certified Components. Utilizar únicamente con componentes certificados de Siemens. A utiliser uniquement avec les composants certifiés Siemens. Tension dangereuse. Danger de mort ou risque de blessures graves. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. Ø 1 mm-1.5 mm X 100 mm Cal ISO 6789 NOTE - These instructions do not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens sales office. The contents of this instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. Ø = .22“ [ Ø = 5.5 ] 5/16” 7mm 1/4” 5/32” 4mm 6mm 11/32“ 7mm NDG4F150 3VL2015-1RA40-0AA0 HDG4F150 3VL2015-2RA40-0AA0 LDG4F150 3VL2015-3RA40-0AA0 Trademarks - Unless otherwise noted, all names identified by ® are registered trademarks of Siemens AG or Siemens Industry, Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. NFG4F250 3VL3025-1RA40-0AA0 HFG4F250 3VL3025-2RA40-0AA0 LFG4F250 3VL3025-3RA40-0AA0 NFG2F250 HFG2F250 LFG2F250 NFG3F250 HFG3F250 LFG3F250 NDG2F150 HDG2F150 LDG2F150 NDG3F150 HDG3F150 LDG3F150 3VL3025-1RA20-0AA0 3VL3025-2RA20-0AA0 3VL3025-3RA20-0AA0 3VL3025-1RA30-0AA0 3VL3025-2RA30-0AA0 3VL3025-3RA30-0AA0 1/ 6 8 0 6 8 0 2 A 0 2 3VL2015-1RA20-0AA0 3VL2015-2RA20-0AA0 3VL2015-3RA20-0AA0 3VL2015-1RA30-0AA0 3VL2015-2RA30-0AA0 3VL2015-3RA30-0AA0 I.L. No. 806802A02 DG / FG 1 Trip [ Interrumpir ] 1 2 2 3 4 1 2 3 5 6 Ex: HFG3F250 / 3VL3025-2RA30-0AA0 HFG3 F250 2X 9 lb. in. [ 1 Nm ] HFG HFG3F250 HFG3F250 cat. no . HFG3 F250 250A In=250 4X 4 lb. in. [ 0.5 Nm ] = 250A In=250A 2/ 6 806802A02 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Tension dangereuse. Danger de mort ou risque de blessures graves. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. Test: [ Prueba: ] 7 Trip [ Interrumpir ] ON / I 1 4 2 OFF / O NDG_F150 HDG_F150 LDG_F150 NFG_F250 HFG_F250 LFG_F250 Trip [ Interrumpir ] 6 OK 3 3VL2015 - 1RA_0 -0AA0 3VL2015 - 2RA_0 -0AA0 3VL2015 - 3RA_0 -0AA0 3VL3025 - 1RA_0 -0AA0 3VL3025 - 2RA_0 -0AA0 3VL3025 - 3RA_0 -0AA0 8 ON / I 5 7 OFF / O Trip .14” [ Interrumpir ] [ 3.5mm ] 2.0 lbf [ 9.0 N ] OK 8 11/32” .06 - .12” ] 1 [ .5 - 3 mm 2X 19 lb. in. [ 2.2 Nm ] 3/ 6 806802A02 DG FG 4/ 6 806802A02 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Tension dangereuse. Danger de mort ou risque de blessures graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. Accessory [ Accesorio ] NDG _ F150 3VL2015-1RA _ _ - 0AA0 HDG _ F150 3VL2015-2RA _ _ - 0AA0 LDG _ F150 3VL2015-3RA _ _ - 0AA0 NFG _ F250 3VL3025-1RA _ _ - 0AA0 HFG _ F250 3VL3025-2RA _ _ - 0AA0 LFG _ F250 3VL3025-3RA _ _ - 0AA0 4 4 2 1/4 [ 6 mm ] 89 lb. in. [ 10 Nm ] 3X 2 5 / 32 [ 4 mm ] 40 lb. in. [ 4.5 Nm ] 2 2 1 1 clic clic 3 3 3X - TMKF3 / 3VL9300-4TA31– M8 X 1.25 X 20mm 1X - TNKF / 3VL9300-4TB01– 5 / 16-18UNC X .75” 3X - TNKF3 / 3VL9300-4TB31–5 / 16-18UNC X .75” Phase B Phase C 4 Pole Application example: [ Aplicación ejemplo de 4 polos :] Phase A TSSF3 3VL9300-8CB31 TSSF4 3VL9300-8CB41 General Information: [ Información General: ] Neutral Accessory [ Accesorio ] 3X - TMKD3 / 3VL9200-4TA31 - M6 X 1 X 20mm 1X - TNKD / 3VL9200-4TB01–10–32UNF X .75” 3X - TNKD3 / 3VL9200-4TB31–10–32UNF X .75” N 1 3 5 Circuit Breaker with Unprotected Neutral N 2 4 6 LOAD Example Customer Tramsformer Phase C Phase B Phase A Neutral For Support in Europe refer to : Bestell-Nr. / Order No.: 3ZX1012-0VL21-0AA1 Technical Support: Subject to change without prior notice Siemens Industry, Inc. , Norcross, GA 30092 U.S.A. Internet: www.siemens.de/lowvoltage/technical-assistance Toll Free: 1-800-241-4453 5/ 6 GWA 4NEB 172 6802-10 DS 03 Internet: www.usa.siemens.com/powerdistribution © Siemens Industry Inc. 2010 806802A02 Mounting Template / [ Patrón para el Montaje ] 2.07” ( 4P ) 52.5 (4P) [ 52.5 ] .69” 2P, 3P & 4P ) 17.5((3P&4P) [ 17.5 ] 1.42” [36 36 ] .77” 19.5 [ 19.5 ] 2.68” 68 [ 68 ] 5.18” 131.5 [ 131.5 ] 1.34” [ 34 ] 2.56” 65 [ 65 ] .71” [ 18 ] 1/4 1/2 3/4 1 in. .69”17.5 ( 2P,(3P&4P) 3P & 4P ) [ 17.5 ] 1 cm 2 3 4 5 2X Ø.217 ( 2P, 3P ) 4X Ø.217 ( 4P ) [ 2X Ø5.5 (2P, 3P ) ] 2X Ø5.5 (3P) [ 4X Ø5.5 (4P ) ] 4X Ø5.5 (4P) Verify 1:1 scale before using [ Verifique la escala de 1:1 antes de usar ] 6/ 6 Dg / Fg_MTG-Template.pdf 806802A02