DT-110PS/PD and DT-111PS/PD Message edition Working order
Transcripción
DT-110PS/PD and DT-111PS/PD Message edition Working order
Message edition Editing and saving messages on the display. Messages are edited by PC with TDL editor of Lartet. LARTET 20 CARACTERES POR LINEA RS-232 SC-105C 512 MENSAJES Recording messages. Messages edited by PC are sent to DT-110P and DT-111P displays by RS-232 serial port and they remain saved in EEPROM memory. Batteries are not needed for message maintenance. ROTACION AUTOMATICA FUSION DE VARIABLES TDL editing program DT-110PS/PD and DT-111PS/PD Message control DT-110PS/PD and DT-111PS/PD are run by PLC, with conventional digital outputs of any kind, NPN, PNP or contacts. There are three different functions: ?Displaying a single message. ?Displaying all the linked messages in autonomous working order. ?Displaying multiple messages in memory. Variables. DT-110P and DT-111P displays not only display texts, but also variables values. For this to be possible, it is necessary to work with static PLC outputs. They allow from one variable with 16 characters to 16 variables of one character to inserted in every message. Every message to be displayed will be given an address, which consists of the binary code. Working order The message are controlled by 14 inputs. LARTET 20 CARACTERES POR LINEA 512 MENSAJES Each message needs a binary code. To control 512 messages 9 bits are needed. RUN STOP ALARM ERROR PLC ROTACION AUTOMATICA FUSION DE VARIABLES PLC-OUTPUTS NPN - PNP CONTACT INPUTS DT-110P DT-111P DT-110SX/DX and DT-111SX/DX DT-110SX,DX and DT-111SX/DX are run by a PC, a PLC or any device with a RS-232 or RS-485 serial output. Using the serial line RS-232 the maximum advisable it is working distance is 10m, while using the serial line RS-485 is 1000m. Transmission protocols: Some protocols are ready to use, select the protocol and run. Lartet protocol: The message sent remains in the buffer display, which saves the information until a new message arrives. ModBus protocol: Follows the ModBus rules using RTU. ASCII protocol: Is an easy protocol without CRC. Host-Link protocol: To be used with Omron PLC’s. It is possible to use the RS-422 serial line, but must be pointed out at your order. Protocol S7-200: To be used with S7-200 Siemens PLC’s. LARTET 20 CARACTERES POR LINEA RS-232 512 MENSAJES ROTACION AUTOMATICA FUSION DE VARIABLES Working order program for the user. LARTET 20 CARACTERES POR LINEA RS-232 RS-485 CONVERTER RS-232/ RS485 512 MENSAJES ROTACION AUTOMATICA FUSION DE VARIABLES Up to 32 displays LARTET 20 CARACTERES POR LINEA Working order program for the user All displays include all the protocols. To select the protocol and other parameters the display has two push buttons and a easy menu. 512 MENSAJES ROTACION AUTOMATICA FUSION DE VARIABLES LARTET 20 CARACTERES POR LINEA 512 MENSAJES RUN STOP ALARM ERROR PLC ROTACION AUTOMATICA FUSION DE VARIABLES RS-232 or RS-485 ModBus, Host-Link, S7-200 TDL editing program SC-105C programming cable Accessories DISTRIBUTED BY ® LARTET a registered trademark of TETRALEC, S.L. 1007K02E