DT-110PS/PD and DT-111PS/PD Message edition Working order

Transcripción

DT-110PS/PD and DT-111PS/PD Message edition Working order
Message edition
Editing and saving messages on the display.
Messages are edited by PC with TDL editor of Lartet.
LARTET
20 CARACTERES
POR LINEA
RS-232
SC-105C
512 MENSAJES
Recording messages.
Messages edited by PC are sent to DT-110P and DT-111P
displays by RS-232 serial port and they remain saved in
EEPROM memory. Batteries are not needed for message
maintenance.
ROTACION AUTOMATICA
FUSION DE VARIABLES
TDL editing
program
DT-110PS/PD and DT-111PS/PD
Message control
DT-110PS/PD and DT-111PS/PD are run by PLC, with conventional digital outputs of any kind, NPN, PNP or contacts.
There are three different functions:
?Displaying a single message.
?Displaying all the linked messages in autonomous working
order.
?Displaying multiple messages in memory.
Variables.
DT-110P and DT-111P displays not only display texts, but also
variables values. For this to be possible, it is necessary to
work with static PLC outputs.
They allow from one variable with 16 characters to 16 variables of one character to inserted in every message. Every
message to be displayed will be given an address, which
consists of the binary code.
Working order
The message are controlled by 14 inputs.
LARTET
20 CARACTERES
POR LINEA
512 MENSAJES
Each message needs a binary code. To control 512 messages
9 bits are needed.
RUN
STOP ALARM ERROR
PLC
ROTACION AUTOMATICA
FUSION DE VARIABLES
PLC-OUTPUTS
NPN - PNP CONTACT
INPUTS
DT-110P
DT-111P
DT-110SX/DX and DT-111SX/DX
DT-110SX,DX and DT-111SX/DX are run by a PC, a PLC or
any device with a RS-232 or RS-485 serial output. Using the
serial line RS-232 the maximum advisable it is working distance is 10m, while using the serial line RS-485 is 1000m.
Transmission protocols:
Some protocols are ready to use, select the protocol and run.
Lartet protocol: The message sent remains in the buffer display, which saves the information until a new message arrives.
ModBus protocol: Follows the ModBus rules using RTU.
ASCII protocol: Is an easy protocol without CRC.
Host-Link protocol: To be used with Omron PLC’s. It is possible to use the RS-422 serial line, but must be pointed out
at your order.
Protocol S7-200: To be used with S7-200 Siemens PLC’s.
LARTET
20 CARACTERES
POR LINEA
RS-232
512 MENSAJES
ROTACION AUTOMATICA
FUSION DE VARIABLES
Working order program
for the user.
LARTET
20 CARACTERES
POR LINEA
RS-232
RS-485
CONVERTER
RS-232/ RS485
512 MENSAJES
ROTACION AUTOMATICA
FUSION DE VARIABLES
Up to 32
displays
LARTET
20 CARACTERES
POR LINEA
Working order program
for the user
All displays include all the protocols. To select the protocol
and other parameters the display has two push buttons and a
easy menu.
512 MENSAJES
ROTACION AUTOMATICA
FUSION DE VARIABLES
LARTET
20 CARACTERES
POR LINEA
512 MENSAJES
RUN
STOP ALARM ERROR
PLC
ROTACION AUTOMATICA
FUSION DE VARIABLES
RS-232 or RS-485
ModBus, Host-Link, S7-200
TDL editing program
SC-105C programming cable
Accessories
DISTRIBUTED BY
®
LARTET a registered trademark of TETRALEC, S.L.
1007K02E