Ground fault protector/earth leakage protector for Series G E
Transcripción
Ground fault protector/earth leakage protector for Series G E
Instructional Leaflet IL01202012E Effective October 2010 Ground fault protector/earth leakage protector for Series G E-Frame circuit breakers and HMCPE motor circuit protectors El protector de fallas a tierra/protector de fugas a tierra para interruptores de circuito Serie G Marco-E y protectores de motores HMCPE WARNING ADVERTENCIA DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH, SEVERE PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE CAN RESULT FROM CONTACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING. NO INTENTE INSTALAR O LLEVAR A CABO TRABAJOS DE MANTENIMIENTO EN EL EQUIPOMIENTRAS TENGA ENERGIA. EL CONTACTO CON EQUIPO CON ENERGIA PUEDE PROVOCAR LA MUERTE O LESIONES PERSONALES SEVERAS. ANTES DE PROCEDER, VERIFIQUE SIEMPRE QUE NO HAYA VOLTAJE PRESENTE. Insert Unit Into Breaker. Attach Endcap. Maximum Breaker Rating 125A Continuous. Coloque la unidad en el interruptor. Reset Unit Coloque la tapa en el extremo. Denominación máxima del interruptor 125A continuo. Figure 1. Figure 3. Tighten Breaker Screws. Insert Screws and Washers. Apriete los tornillos del interruptor. Inserte los tornillos y arandelas dentro de los retenedores. 0.156 in (3.97mm) 0.156 pulg. A_1 A_1 A_1 A_1 34–38 in lb (3.8–4.3 Nm) 34–38 pulg./lb. Figure 2. Figure 4. Instructional Leaflet IL01202012E Ground fault protector/earth leakage protector for Series G E-Frame circuit breakers and HMCPE motor circuit protectors Effective October 2010 Remove Secondary Cover. Test by Pushing Push-To-Trip Button. Remueva la tapa secundaria. Pruebe la unidad presionado el boton de disparo. 1 3 2 Figure 5. Figure 9. 3 Reset Unit and Latch Breaker. Insert Push Bar into Mechanical Accessory. Reinicie la unidad y cierre el interruptor. Inserte la barra en el accesorio mecánico. 2 Figure 6. 1 Figure 10. Insert Push Bar into RCD Window and Rotate Mechanical Accessory into Pocket. Attach Accessories. Coloque los accesorios. Inserte la barra en la ventana del RCD y rote el accesorio dentro de la cavidad (abertura). Customer Provided Contact. Bell Alarm (3A–250V~) White White Black 50% IG (0.1A–250V~) Remote Trip (0.1A–250V~) Accessory Wires Figure 11. Figure 7. Replace Secondary Cover, Reset Unit and Latch Breaker. Reemplace la tapa secundaria y opere el interruptor. 3 Position of the Toggle Handle 1 Off/Reset Apriete los tornillos de la tapa secundaria a un torque de 10–13 pulg. lb. (1.1–1.5 Nm). Figure 8. On ON Tripped TRIP Orange Blue Green Orange Blue Green State of bell alarm contacts as a function of circuit breaker and protector. Estado de los contactos de la alarma de timbre como una función de interruptor de circuito y protector. Figure 12. eaton corporation www.eaton.com Position of the Protector Position of the Reset Button (Yellow) Protector Bell Alarm Orange Blue Green ON 2 Torque Secondary Cover Mounting Screws 10–13 in lb (1.1–1.5 Nm). 2 Black Green Blue Orange Contacto provisto por el cliente. Instructional Leaflet IL01202012E Ground fault protector/earth leakage protector for Series G E-Frame circuit breakers and HMCPE motor circuit protectors 50% IG (or 50% I n) (Indicates 50% of Leakage Value has Been Reached) Test Button Boton de prueba 50% IG (o 50% I n) Indica que 50% del valor defuga fue alcanzado) Status Light (Flashes to indicate proper operation) Push-to-Trip Button Boton de disparo C.B. Acc. 560U Ground Fault Protector Cat. ELEBN4125W S# 68D3907G03 Terminal Block Access (4-Pole Only) Acceso al bloque de terminal (4 polos solamente) STATUS 50% IG TEST Push to Trip RESET IG (A) t(s) 0.15 0.06 0.3 0.3 0.5 Inst. 1 0.1 3 0.03 1 10 NOTICES: - Terminals if used must be aluminum 0.03 Inst. TA125EF or TA150EF (Al/Cu). - See breaker for terminal torque. - See instrction sheet for high voltage tests. - For use on Seres G, E-Frame Circuit Breaker, Switch, Motor Circuit Protector. WARNING Hazardous voltage – can cause severe injury or death. In reverse-feed applications GFP (Ground Fault Protector) is energized when breaker handle is in any position. Disconnect all power before installing or removing GFP. Do not remove cover from GFP. t(s) (o t) Adjustment CU-A L 68 C3733 H04 Reset Button Boton de reinicio In 125A 4 POLE 120–480 VΣ 50/60 Hz Class 1 Luz para indicacion del estado (Parpadea para indicar operacion apropiada) IG (or In) Adjustment Adjuste del IG (o I n) Adjuste de t(seg.) (o t) Figure 13. Product operation 1. Earth leakage detected a. 50% Earth Leakage setting detected, LED and contacts change state. b. 100% Earth Leakage setting detected, the module trips the circuit breaker via mechanical interlock. c. Reset button on earth leakage module extends, indicating trip due to earth leakage current. d. Bell Alarm Auxiliary NO/NC contact in module changes state. 2. Reset a. Depress Reset button on module (if tripped on earth leakage). This will reset the mechanical interlock allowing the circuit breaker to be reset. b. Reset circuit breaker. Effective October 2010 Operación del producto 1. Falla a tierra detectada a. Se detecta 50% de Falla a Tierra, el LED y contactos cambian de estado. b. Se detecta 100% de Falla a Tierra, el modulo dispara el interruptor de circuito por medio del enlace mecánico. c. El botón de reajuste en el modulo de fallo a tierra se extiende, indicando que hubo un disparo debido a un fallo de corriente a tierra. d. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado. 2. Reajustar a. Presione el botón de reajuste en el modulo (si se disparo debido a falla a tierra). Esto reajustara el enlace mecánico lo que permitirá que el interruptor de circuito pueda ser reajustado. b. Reajustar el interruptor de circuito. 3. Prueba de operación (el voltaje de línea debe de estar presente) a. Presione el botón de prueba para probar el circuito de fallo a tierra. b. El modulo dispara el interruptor de circuito por medio del enlace mecánico. c. El botón de reajuste en el modulo de fallo a tierra se extiende. d. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado. 4. Disparo remoto del interruptor de circuito a. Señal energizada suplida por el cliente (contacto seco cercano). b. El modulo dispara el interruptor de circuito por medio del enlace mecánico. c. El botón de reajuste en el modulo de fallo a tierra se extiende. d. El contacto en el modulo Alarma de Campana Auxiliar NO/NC cambia de estado. Table 1a. EG-Frame Line and Load Terminations Wire Size Torque mm2 Terminal Materials Catalog Number Lb In 2.5–6 Aluminum TA125EF a 35 4.0 16–95 Aluminum TA150EF 80 9.0 Frame Type Wire Type AWG a. Depress test button to test earth leakage circuit. EG-Frame Cu/Al 14–10 b. The module trips circuit breaker via mechanical interlock. EG-Frame Cu/Al 6–3/0 c. Reset button on earth leakage module extends. a Standard collars mounted on ground fault/earth leakage. d. Bell Alarm Auxiliary NO/NC contact in module changes state. Table 1b. Terminaciones de línea y carga del marco EG 3. Test operation (line voltage must be present) Tamano de Alambre 4. Remote tripping of breaker (line voltage must be present) a. Customer-supplied signal energized (dry contact closer). Tipo de Marco Tipo de Alambre AWG b. The module trips the circuit breaker via mechanical interlock. Marco EG Cu/Al 14–10 Marco EG Cu/Al 6–3/0 c. Reset button on earth leakage module extends. d. Bell Alarm Auxiliary NO/NC contact in module changes state. Nm Torosion mm Material de la terminal Numero de catalogo Lb In Nm 2.5–6 Aluminio TA125EF a 35 4.0 16–95 Aluminio TA150EF 80 9.0 2 a Conectores estándares montados en el dispositivo falla a tierra/fuga a tierra. eaton corporation www.eaton.com 3 Instructional Leaflet IL01202012E Ground fault protector/earth leakage protector for Series G E-Frame circuit breakers and HMCPE motor circuit protectors Effective October 2010 10.26 (260.6) 0.50 (12.7) 1.00 (25.4) 2.00 (50.8) 3.98 (101.1) Four-Pole 2.98 (75.7) Three-Pole 1.49 (37.8) 0.97 (24.6) 3.81 (96.8) 8.59 (218.2) 2.96 (75.2) 2.90 (73.7) 2.74 (69.6) 2.75 (69.9) 3.01 (76.5) 3.54 (89.9) 3.58 (90.9) 10.26 (260.6) 5.50 (139.7) 1.00 (25.4) 3.00 (76.2) 2.00 (50.8) 1.49 3.98 (101.1) Four-Pole (37.8) 2.98 (75.7) Three-Pole 0.97 (24.6) 3.81 (96.8) 8.59 (218.2) Figure 14. Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com © 2010 Eaton Corporation All Rights Reserved Printed in USA Publication No. IL01202012E H01 / Z10486 October 2010 PowerChain Management is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.