2.4 Installing the Universal IDU Indoor Unit

Transcripción

2.4 Installing the Universal IDU Indoor Unit
Chapter 2 - Installation
2.4
Installing the Universal IDU Indoor Unit
Installing the Universal IDU Indoor Unit
The unit can be placed on a desktop or a shelf. Alternatively, it may be
wall-mounted using the kit supplied with the unit.
Figure 2-13: IDU PS 1073 Front Panel
The RADIO connector and RESET button are located on the front panel, the
ETHERNET connector is located on the side panel and LEDs are located on the
top panel.
CAUTION
Do not connect the data equipment to the RADIO port. The RADIO port supplies DC power to the
ODU, and this may harm other equipment connected to it.
To install the IDU:
1
Connect the Indoor-to-Outdoor cable to the RADIO connector, located on the
front panel of the indoor unit.
2
Connect the power cord to the unit's AC socket, located on the rear panel.
Connect the other end of the power cord to the AC mains. The unit can operate
with AC mains of 100-240 VAC, 50-60 Hz.
NOTE
The color codes of the power cable are as follows:
Brown
Phase
Blue
Neutral
Yellow/Green
Ground
3
BreezeACCESS VL
~
0
Verify that the POWER LED is lit, indicating that power is supplied to the unit.
53
System Manual
Chapter 2 - Installation
4
Installing the Universal IDU Indoor Unit
Configure the basic parameters as described in “Configuring Basic
Parameters” on page 73.
5
Connect the 10/100 BaseT ETHERNET connector to the network. The cable
connection should be a straight Ethernet if connecting the indoor unit to a
hub/switch and a crossed cable if connecting it directly to a PC Network
Interface Card (NIC).
NOTE
The length of the Ethernet cable connecting the indoor unit to the user's equipment, together with
the length of the Indoor-to-Outdoor cable, should not exceed 100 meters.
2.4.1
RESET Button Functionality
Using a sharp object, press the recessed RESET button for a short time to reset
the unit and reboot from the Main version.
In units with ODU HW revision C and higher, the RESET button can be used for
setting the unit to its factory defaults. Press the button for about 10 seconds (until
the ETH LED of the IDU stops blinking): the unit will reboot with the factory
default configuration.
BreezeACCESS VL
54
System Manual