Sales Flier: Installer`s Pocket Guide (S-C
Transcripción
Sales Flier: Installer`s Pocket Guide (S-C
INSTALLER’S POCKET GUIDE GUÍA DE BOLSILLO PARA EL INSTALADOR S-C-INSTALL16 Simpson Strong-Tie QUESTIONS? ¿PREGUNTAS? (800) 999-5099 or visit strongtie.com The information in this guide shows contractors how our Simpson Strong-Tie® products should be correctly installed. It is not intended for use by Designers. It is important that users of this guide also follow any installation guidelines specified by the Designer and refer to the current Simpson Strong-Tie Wood Construction Connectors catalog for other crucial installation information. Esta guía tiene como objetivo servir como herramienta de referencia rápida para facilitar la correcta instalación de los productos Simpson Strong-Tie®. Es importante que los usuarios sigan todas las pautas de instalación especificadas por el diseñador y consulten el catálogo de Conectores para Construcciones de Madera de Simpson Strong-Tie para obtener más información importante sobre la instalación. 2 Index/Indice Concrete Connectors & Anchors BPS-LBPS............................ 15 FWANZ.................................. 16 MAB................................ 17–19 MASA.............................. 20–23 SB......................................... 24 SSTB..................................... 25 UFP....................................... 26 Holdown & Tension Ties HD......................................... 27 HDQ8.................................... 28 HDU...................................... 29 HTT....................................... 30 STHD.................................... 31 Caps & Bases ABA....................................... 32 ABU ............................... 33–35 ABW...................................... 36 BC......................................... 37 BCS2-2/ 4.............................. 38 BC40..................................... 39 CB................................... 40–41 CBSQ.................................... 42 CC........................................ 43 CCQ...................................... 44 CPTZ..................................... 45 LCE4..................................... 46 PB......................................... 47 PCZ/EPZ............................... 48 RPBZ.................................... 49 PPBZ..................................... 50 Solid Sawn Joist Hangers HUS...................................... 51 LSSU..................................... 52 LUCZ..................................... 53 LUS................................. 54–55 SUR/L............................. 56–57 VPA................................. 58–59 Engineered Wood & Structural Composite Lumber Connectors ITS.................................. 60–61 IUS.................................. 62–63 Plated Truss Connectors DTC....................................... 64 HTU....................................... 65 STC....................................... 66 THA................................. 67–68 THJA..................................... 69 THJU..................................... 70 TSBR.................................... 71 Masonry Connectors HETA............................... 72–73 LGT................................. 74–75 VGT................................. 76–77 Straps & Ties A35....................................... 78 CS/CMST14.................... 79–80 H1................................... 81–82 H2.5A.................................... 83 H2.5T.................................... 84 H10A............................... 85–86 LS......................................... 87 LSTA..................................... 88 LTP4/LTP5............................. 89 MST................................ 90–91 RBC...................................... 92 RSP....................................... 93 SP......................................... 94 SSP....................................... 95 TSP....................................... 96 Decking DTT1Z................................... 97 DTT2Z................................... 98 Miscellaneous HSS...................................... 99 PSPN.................................. 100 TWB............................ 101–102 Anchoring & Fastening Systems for Concrete and Masonry Adhesive Anchoring..... 103–104 Titen HD®............................ 105 Fastening Systems Strong-Drive® SDWC........... 106 Strong-Drive® SDWF....107–108 3 Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: To fasten a connector. •• Fill Requirements: Always fill, unless otherwise noted. ROUND REDONDO •• Propósito: Para fijar un conector. •• Requisitos para Llenar: Llénelo siempre, salvo que se indique lo contrario. •• Purpose: To increase a connector’s strength or to achieve MAX strength. TRIANGULAR •• Fill Requirements: When the Designer specifies Max nailing. •• Propósito: Para aumentar la fuerza de un conector o para lograr una fuerza máxima. •• Requisitos para Llenar: Llénelo cuando el diseñador lo especifica clavado “Máx.” •• Purpose: To fasten a connector to concrete or masonry. HEXAGONAL HEXÁGONO •• Fill Requirements: Always fill when fastening a connector to concrete or fastening a connector with masonry screws. •• Propósito: Para fijar un conector a concreto o mampostería. •• Requisitos para Llenar: Siempre llénelo al fijar un conector a concreto o al fijar un conector con tornillos de mampostería. 4 Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: To make fastening a connector in a tight location easier. OBROUND ALARGADO •• Fill Requirements: Always fill, unless otherwise noted. •• Propósito: Para fijar un conector en una locación apretada con el fin de facilitar el trabajo. •• Requisitos para Llenar: Llénelo siempre, salvo que se indique lo contrario. •• Purpose: To temporarily fasten a connector to make installing it easier. DIAMOND DIAMANTE •• Fill Requirements: None. •• Propósito: Para fijar temporalmente un conector, con el propósito de facilitar su instalación. •• Requisitos para Llenar: Ninguno. 5 Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: Installed into the joist and header, distributing the load through two points on each joist nail for greater strength. Must use full length nail. •• Fill Requirements: Always fill. DOUBLE-SHEAR NAILING CLAVADO DE DOBLE PENETRACIÓN •• Propósito: Para lograr mayor fuerza, los clavos penetran a la vigueta y la viga cabezal, así distribuyendo la carga entre las dos puntas de cada clavo. •• Requisitos para Llenar: Llénelo siempre. DO NOT use short (1 1/2") nails for double-shear nailing. NO usen los clavos cortos de 1 1/2" para uso de doble penetración. •• Purpose: To temporarily position and secure the connector for easier and faster installation. •• Fill Requirements: None. SPEED PRONGS DIENTES RÁPIDOS •• Propósito: Se usan para colocar el conector y fijarlo temporalmente, con el fin de facilitar y hacer más rápida su instalación. •• Requisitos para Llenar: Ninguno. 6 Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: To guide the nail into the joist and header at a 45° angle. •• Fill Requirements: Always fill. DOME NAILING U.S. Patent No. 5,603,580 CLAVADO CON CÚPULA •• Propósito: Con este dispositivo se guían el clavo en lavigueta y la viga cabezal en ángulo de 45°. •• Requisitos para Llenar: Llénelo siempre. Patente de EE.UU. No. 5,603,580 •• Purpose: Provided when wood splitting may occur, and to speed installation. •• Fill Requirements: Always fill. POSITIVE-ANGLE NAILING CLAVADO EFECTIVO EN ÁNGULO •• Propósito: Se usa cuando la madera puede rajarse oabrirse y con el propósito hacer más rápida la instalación. •• Requisitos para Llenar: Llénelo siempre. 7 Fasteners/Clavos 16d 16d x 2 1/2" 16d Sinker 10d Same uses Mismo uso (0.162") (0.162") 16d Common Straps, heavy hangers, plated truss and SCL connectors. 16d Común Cintas, soporte de viga pesadas, para cerchas y madera composito. 8 16d x 2 1/2" 3x Wood nailers. NOT for double-shear nailing unless approved by Designer. 16d x 2 1/2" Para madera de 3". NO para clavado de double penetración salvo que así lo apruebe el diseñador. (0.148") (0.148") 16d Sinker Straps, hangers, header fastening. 16d Sinker Cintas, soporte de viga. 10d Common Straps, hangers, header fastening. 10d Común Cintas, soporte de viga. Fasteners/Clavos 10d x 1 1/2" 8d 8d x 1 1/2" (0.148") (0.131") 10d x 11/2" 2x Joist nailing. Caution: Load reduction if used as header nails. 8d x 11/2" Light-duty framing anchors and some rafter ties. Galvanized nail shown. 10d x 11/2" Clavado de vigas 2x. Cuidado: Reduce la capacidad si se usa en la viga cabezal. (0.131") 8d Common Rafter ties. 8d Común “Clips” de huracán. Galvanized nail shown. 8d x 11/2" Conectores ligeros y “clips” de huracán. Se muestra un clavo galvanizado. Se muestra un clavo galvanizado. When using stainless-steel connectors, use stainless-steel fasteners. When using ZMAX®/hot-dip galvanized connectors, use fasteners galvanized per ASTM A153. Al usar los conectores del acero inoxidable, utilice los sujetadores del acero inoxidable. Al usar conectores ZMAX®/HDG galvanizados, utilizan los sujetadores galvanizados por ASTM A153. 9 Fasteners/Clavos Framing nail-gun nails can only be used if: 1. Correct diameter and length 2. Correct quantity is installed 3. Driven with a hole location tool (finds the hole) or by hand NOTE: .121 may NOT be used to replace 10d or 16d nails. Sólo se pueden utilizar clavos estructurales para pistola si: 1. Tengan diámetro y tamaño correcto 2. Se instala la cantidad correcta 3. Usan maquina que encuentre el agujero, o se clavan a mano DO NOT OVERDRIVE H2.5 WRONG NO SHOOTING-THRU CONNECTORS NO SE METE DEMASIADO NO SE PUEDE HACER AGUJEROS CON MAQUINA NOTA: NO se pueden utilizar clavos 121 como sustitutos de clavos 10d o 16d. Common screws, such as wood and drywall screws, may NOT be used to replace NAILS in connectors. NO se puede usar tornillos comunes, tales como tornillos para madera y panel yeso, en vez de CLAVOS en conectores. 10 12 Fasteners/Clavos 00 12 00 12 Some connectors install with the Simpson Strong-Tie® Strong-Drive® 1/4" SDS HEAVY-DUTY CONNECTOR screw. 1. Install with 3⁄8" hex socket or nut driver 2. Pre-drilling generally not required 3. Do not substitute with lag screws Algunos conectores se instalan con el Simpson Strong-Tie® Strong-Drive® 1/4" SDS HEAVY-DUTY CONNECTOR screw. 1. Instalar con un destornillador de casquillo hexagonal o de tuercas de 3⁄8" 2. Generalmente no es necesario efectuar perforaciones previas 3. No sustituir con tirafondos TITEN® Masonry Screw Diameter: 3/16", 1/4" Tornillo Para Mampostería Diametro: 3/16", 1/4" Machine Bolt Diameter: 1/2", 5/8", 3/4", 7/8", 1" Pernos Diametro: 1/2", 5/8", 3/4", 7/8", 1" 11 General Connector Installation Instalación de Conectores en General TOP FLANGE HANGERS SOPORTES CON ALA SUPERIOR Hanger over-spread Hanger not plumb Soporte demasiado abierto Soporte fuera de plomo WOOD NAILERS LISTONES CLAVADORES DE MADERA ¼" max. Correct attachment Nailer too wide Montaje correcto Listón clavador muy ancho Nailer too narrow Nailer too thin Listón clavador muy estrecho Listón clavador demasiado delgado 12 General Connector Installation Instalación de Conectores en General PREVENT ROTATION / EVITAR LA ROTACIÓN Shorter hanger with no web stiffener results in rotation Un soporte colgante más corto sin de entramado permitirá la rotación TOE-NAILING / CLAVADO EN DIAGONAL Do not toe-nail I-joists before installing top flange or face-mount hangers No clave en ángulo las viguetas ‘I’ antes de montar los soportes (con o sin ala superior) POSITIVE ANGLE NAILING CLAVADO EFECTIVO EN ÁNGULO Correct nailing approx. 45° angle Clavado correcto aproximadamente a 45° Nail at wrong angle Nail too long Clavado con un ángulo incorrecto Clavos demasiado largos 13 General Connector Installation Instalación de Conectores en General ITS/IUS HANGERS / SOPORTES DE ITS/IUS DO NOT make your own holes NO HAGA sus propios agujeros DO NOT nail seat hole, #8 wood screw is OK NO clave en los agujeros del conector, tornillos para madera #8 es aceptable DOUBLE-SHEAR NAILING CLAVADO DE DOBLE PENETRACIÓN Double-shear nailing must use full length 10d or 16d common nails Al trabajar con clavado de doble penetración, se deben emplear clavos comunes 10d o 16d de longitud normal Shorter nails may not be used as double-shear nails No se pueden utilizar clavos más cortos como clavos de doble penetración 14 Concrete Connectors & Anchors BPS-LBPS 1 BPS-LBPS-IN-1 BPS-LBPS-IN-1 BPS-LBPS-IN-1 2 BPS-LBPS-IN-2 BPS-LBPS-IN-2 3 BPS-LBPS-IN-2 BPS-LBPS-IN-3 BPS-LBPS-IN-3 15 FWANZ HDG N8HDG SSN10 SSN8 10d x 11/2" (0.148" x 11/2") 1 2 16 al MAB – Block/Bloque N16 SS8D 2½" Spiral N54 (Included with product) N10HDG N8HDG SSN10 1 SSN8 10d x 11/2" (0.148" x 11/2") MAB-IN-1 MAB-IN-2 MAB-IN-1 2 3/4" MAB-IN-2 MAB-IN-2 3/4" 3 MAB-IN-3 MAB-IN-4 MAB-IN-3 4 17 MAB-IN-4 MAB-IN-4 MAB – Concrete/Concreto 1 MAB15IN1 2 MAB15IN2 3 MAB15IN3 4 MAB15IN4 5 18 MAB15IN5 MAB – Concrete/Concreto 6 MAB15IN6 7 SSN8 MAB15IN7 0HDG N8HDG SSN10 MAB15IN9 10d x 11/2" (0.148" x 11/2") 19 MASA 2 1/2 x 2 1/2) 10d Common Forming (0.148 x 3) Encofrado 2-8d Duplex nails / Clavo duplex or/ó 1-10d or/ó 1 MASA-IN-1 8d Duplex (0.131" x 21/2") MASA-IN-3 10d (0.148" x 3") Connector 2 G N8HDG Conector SSN10 SSN8 MASA-IN-1 MASA-IN-1 -3 MASA-IN-3 10d x 11/2" (0.148" x 11/2") 3 MASA-IN-5 MASA-IN-4 20 MASA MASA-IN-3 4 MASA-IN-4 5 MASA-IN-5 Option 1 Opción 1 Reduced loads apply, check with Designer. Se aplican cargas reducidas; consulte al diseñador. (MASAP Similar) Option 2 Opción 2 Blocking required attached to sill with A35Z (not shown) or per Designer. Se debe adjuntar un bloqueo al larguero con A35Z (no se muestra) o según indicaciones del diseñador. Reduced loads apply, check with Designer before nailing over sheathing. Se aplican cargas reducidas; consulte al diseñador antes de clavar sobre el relleno. 21 MASA Brick-Ledge Installation Instalación Sobre Cornisa de Ladrillos 2-8d Duplex nails / Clavo duplex or/ó 1-10d 1 2x4 Plate 3½" 2 3 22 MASA Inside-the-Mudsill Installation Instalación en Solera 2-8d Duplex nails / Clavo duplex or/ó 1-10d MASA-IN-2 1 IN-1 MASA-IN-5 2 3 MASA-IN-4 MASALTin2 MASAP/MASP Similar / Similar 23 (MASAP Similar) SB Embedment line (top of concrete) AnchorMate® Línea de empotramiento (parte superior del concr Embedment Embedment line line (top (topofofconcrete) concrete) 1 Línea Líneade deempotramiento empotramiento (parte (partesuperior superiordel delconcreto) concreto) Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) SB-IN-1 24 24 SB-IN-1 24 24 24 24 SB-IN-2 SB-IN-1 SB-IN-2 Install a minimum 45° from either edge. 450 24 34 24 Instalar a mínimo 45° de cada cara. SB-IN-2 SB-IN-3 2 SB-IN-3 24 SB-IN-3 24 450 SSTB AnchorMate® Embedment line Embedment line (top of concrete) 1 (top of concrete) Línea de empotramiento Línea de empotramiento (parte (partesuperior superiordel del concreto) concreto) Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) 24 24 SSTB_1 24 SSTB-IN-2a SB-IN-1 450 34 Install 45° from either edge. 450 24 24 24 Instalar 45° de cada cara. SB-IN-2 2 25 SB-IN-3 UFP 1 2 3 4 5 6 7 S3 S3 S3 S3 S3 26 Holdowns & Tension Ties HD 1 Model No. / N.º de Modelo Machine Bolt Diameter / Diámetro del Perno Torneado HD3B HD5B HD7B HD9B HD12 HD19 5⁄8" 3⁄4" 3⁄4" 7⁄8" 1" 1" 2 3 4 Machine Bolt Diameter: 1/2" Length: ABU44/ABU46 = 4 1/2" ABU66 = 6 1/2" 5 Perno Torneado Diámetro: 1/2" Largo: ABU44/ABU46 = 4 1/2" ABU66 = 6 1/2" Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Los orificios para los pernos deben ser al menos 1⁄32" y como máximo 1⁄16" más grandes que el diámetro del perno. 27 HDQ8 1 2 HDQIN1 3 HDQIN2 Square washer required (included). Se requiere una arandela cuadrada (incluida). 412 Use 3⁄8" driver. 312 HDQIN3 Use un destornillador de 3⁄8". 300 212 28 1/4" x 3" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw (Included / Incluida) HDU 1 2 HDU-IN-1 1 HDU-IN-2 HDU-IN-2 3 HDU-IN-1 HDU-IN-2 412 312 300 212 HDU-IN-3 Use 3⁄8" driver. HDU-IN-3 Use un destornillador de 3⁄8". HDU-IN-3 1/4" x 2 1/2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw (Included / Incluida) 29 HTT 16d x 2 1/2 HTT4 (0.162 x 2 1/2) HTT5 10d Common (0.148 x 3) 1 HTTIN1 2 16d x 2 1/2" (0.162" x 2 1/2") 3 HTTIN2 30 HTTIN3 STHD – w/StrapMate® StrapMate® SSN8 Línea de empotramiento (parte superior del concreto) 2 Strap may be bent down and back up one time only. La abrazadera se puede doblar hacia abajo y hacia arriba sólo una vez. 3½" Spiral (16DHDG similar size diffenrent finish) 16d Sinker (10DHDG similar size different finish) 3" Spiral N16 SS8D 2½" Spiral (Included with product) Embedment line (top of concrete) N10HDG N8HDG SSN10 1 16d Sinker (0.148" x 3 1/4") 31 Caps & Bases N10HDG N8HDG SSN10 SSN8 ABA 1 (Included (10DHDG Spiral diffenrent finish) Sinker different finish) Spiral with 3" 2½" similar size product) Spiral different finish) Spiral N16 SS8D product) Spiral N16 SS8D N10HDG N8HDG SSN10 SSN8 ABAIN1 6d nker 32 2 ABAIN2 3 ABAIN3 If using an adhesive anchor, see pages 103–104 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 103–104. 4 ABAIN4 16d (0.162" x 3 1⁄2") – ABA46, ABA46R, ABA66, ABA66R 10d (0.148" x 3") – ABA44, ABA44R ABU – Nails/Clavos 3½" Spiral ss16D (16DHDG similar size diffenrent finish) 1 ABUIN1 2 ABUIN2 3 ABUIN3 4 16d (0.162" x 3 1/2") 5 ABUIN3 ABUIN5 If using an adhesive anchor, see pages 103–104 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 103–104. 33 ABUIN4a_BOLTS 1 Sin ABU – Machine Bolts/Pernos 1 ABUIN1 2 ABUIN2 3 ABUIN3 4 If using an adhesive anchor, see pages 103–104 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 103–104. 5 34 ABUIN5 ABUIN ABU – Machine Bolts/Pernos 6 ABUIN4b_BOLTS 7 ABUIN4c_BOLTS 8 Machine Bolt Perno Torneado ABUIN4d_BOLTS Diameter: 1/2" Diámetro: 1/2" Length: Largo: ABU44/ABU46 = 4 1/2" ABU44/ABU46 = 4 1/2" ABU66 = 6 1/2" ABU66 = 6 1/2" Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Los orificios para los pernos deben ser al menos 1⁄32" y como máximo 1⁄16" más grandes que el diámetro del perno. 35 6d nker ABW SS10D (10DHDG similar size different finish) 3" Spiral N16 SS8D N54 (Included with product) 2½" Spiral 1 2 3 10d (0.148" x 3") 4 5 6 36 7 N10HDG N8H BC 3½" Spiral ss16D (16DHDG similar size diffenrent finish) 1 BCIN1 2 BCIN2 16d (0.162" x 3 1⁄2") 3 BCIN3 4 37 16d Sinke 16d nker BCS2-2/4 SS10D (10DHDG similar size different finish) 3" Spiral N16 SS8D 1 2½" Spiral N54 (Included with product) 2BCS2-2/4-IN-1 BCS2-2/4-IN-1 BCS2-2/4-IN-1 N10HDG N8H BCS2-2/4- BCS2-2/4-IN-2 BCS2-2/4-IN-2 3 BCS2-2/4-IN-1 BCS2-2/4-IN-2 BCS2-2/4-IN-3 10d (0.148" x 3") 38 -2/4-IN-3 BCS2-2/4-IN-3 BCS2-2/4-IN-3 BCS2-2/4-IN-4 BCS2-2/4-IN-4 4 BCS2-2/4-IN-4 BC40 3½" Spiral ss16D (16DHDG similar size diffenrent finish) 16d Sinker 1 BC40IN1 2 BC40IN2 16d (0.162" x 3 1/2") 3 39 BC40IN3 CB – Machine Bolts/Pernos 1 CBIN1 3" Side cover (min.) 3" min. 3" min. Cubierta lateral de 3" (mín.) 2 CBIN2 3 40 CB 3" Side cover (min.) Cubierta lateral de 3" (mín.) 3" min. 3" min. 4 CBIN4 Model No. / N.º de Modelo Machine Bolt Size / Tamaño del Perno CB44 CB46 CB48 CB64 CB66 CB68 CB86 CB88 CB1010 CB1012 CB1212 5⁄8" x 4 1⁄2" 5⁄8" x 4 1⁄2" 5⁄8" x 4 1⁄2" 5⁄8" x 4 1⁄2" 5⁄8" x 6 1⁄2" 5⁄8" x 6 1⁄2" 3⁄4" x 8 1⁄2" 3⁄4" x 8 1⁄2" 3⁄4" x 10 1⁄2" 3⁄4" x 10 1⁄2" 3⁄4" x 11 1⁄2" 5 CBIN5 Machine Bolt Perno Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Los orificios para los pernos deben ser al menos 1⁄32" y como máximo 1⁄16" más grandes que el diámetro del perno. 6 41 CBIN6 CBSQ 3" 3" min. min. 3"3"min. min. 3" min. 412 3" 3" min. min. 3"3"min. min. 3" min. 1 CBSQ-1 CBSQ-1 CBSQ-1 CBSQ-1 CBSQ-1 2 3 CBSQ-2 CBSQ-2 CBSQ-2 CBSQ-2 CBSQ-2 CBSQ-3 CBSQ-3 CBSQ-3 CBSQ-3 CBSQ-3 312 300 4 212 CBSQ-4 CBSQ-4 CBSQ-4 CBSQ-4 CBSQ-4 5 CBSQ-5 CBSQ-5 CBSQ-5 CBSQ-5 CBSQ-5 200 112 1⁄4" x 2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 42 Use 3⁄8" driver. Use un destornillador de 3⁄8". CC CC-IN-2 1 CC-IN-1 CC-IN-1 CC-IN-1 CC-IN-2 CC-IN-2 2 CC-IN-2 CC-IN-2 CC-IN-1 CC-IN-1 CC-IN-2 CC-IN-1 3 CC-IN-3 CC-IN-4 4 CC-IN-3 CC-IN-3 CC-IN-3 CC-IN-3 CC-IN-4 CC-IN-4 Machine Bolt / Perno CC-IN-4 CC-IN-4 CC-IN-3 CC-IN-4 5 CC-IN-5 CC-IN-5 CC-IN-5 CC-IN-6 Machine Bolt Size Beam or CC-IN-5 Column Width Tamaño del Perno Torneado CC-IN-5 Ancho de Dintel o de Columna Diameter Diámetro Length Longitud 3 1⁄8" 5⁄8" 4 1⁄2" 5⁄8" 4 1⁄2" 5 1⁄8" 3⁄4" 6 1⁄2" 5 1⁄2" 5⁄8" 6 1⁄2" 6 3⁄4" 3⁄4" 8" 7" 3⁄4" 8" 7 1⁄2" 3⁄4" 8 1⁄2" 8 3⁄4" 3⁄4" 10" 9 1⁄2" 3⁄4" 10 1⁄2" 3 1⁄2" CC-IN-5 CC-IN-6 CC-IN-6 CC-IN-6 CC-IN-6 6 CC-IN-6 Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Los orificios para los pernos deben ser al menos 1⁄32" y como máximo 1⁄16" más grandes que el diámetro del perno. 43 CCQ 1 2 25412 3 25312 Use 3⁄8" driver. 25300 Use un destornillador de 3⁄8". 4 25212 ¼" x 2 ½" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 44 25200 CPTZ 1 2 3 4 5 6 7 8 If using an adhesive anchor, see pages 103–104 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 103–104. 9 10 45 LCE4 ss16D (16DHDG similar size diffenrent finish) 3½" Spiral 16d Sinker SS10D (10DHDG similar size different finish) 3" Spiral N16 4x4 Beam Viga 4x4 Post Poste 1 16d (0.162" x 3 1/2") 2 3 46 SS8D 2½" Spiral PB 3½" Spiral ss16D (16DHDG similar size diffenrent finish) 1 PBIN1 2 PBIN2 16d (0.162" x 3 1/2") 3 PBIN3 4 5 47 PBIN4 PBIN5 16d Sinke 6d ker PCZ/EPZ 1 SS10D (10DHDG similar size different finish) 2 3 3" Spiral N16 SS8D 2½" Spiral N54 4 (Included with product) 1 10d (0.148" x 3") 48 3 2 4 N10HDG N8H RPBZ 1 2 SDS25412 3½" Side cover (min.) 3½" Cubierta SDS25312 lateral 3 4 SDS25300 S1.5 S1.5 S1.5 SDS25212 S1.5 SDS25200 5 6 SDS25112 1/4" x 1 1/2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 49 PPBZ Mark drill holes. Marque los agujeros a taladrar. 1" min. 1" min. Drill ¼"-diameter hole ½" deeper than Titen®. 6" min. 1 Perfore un agujero de ¼" de diámetro a una profundidad de ½" mayor que el Titen®. N10HDG N8HDG SSN10 SSN8 2 4 5 6 similar size different finish) 3" Spiral N16 SS8D 2½" Spiral with product) 3 er 50 Titen® Masonry Screw/Tornillo para mampostería (1/4" x 1 1/4") For installation in concrete, use Titen 1/4" x 1 1/4". Para instalaciones en concreto, utilice Titen de 1/4" x 1 1/4". 10d (0.148" x 3") Solid Sawn Joist Hangers HUS 2 1 ss16D (16DHDG HUSIN2 3½" similar size Spiral diffenrent finish) HUSIN1 3 HUSIN3 4 HUSIN4 16d (0.162" x 3 1⁄2") 5 HUSIN5 51 16d Sinke LSSU 10d x 1½" N54 ss16D SS10D (Included (16DHDG (10DHDG 16d x 2 1/2 10d Common with size 2½" 3½" 16d 3" similar similar size 0.162 x 2 1/2) (0.148 x 3) product) finish) Spiral Spiral diffenrent SinkerN8HDG Spiral N10HDG SSN10 different finish)SSN8 1 N16 SS8D 2½" Spiral N54 (Included with product) 2 10d x 1 1/2" (0.148" x 1 1/2") 16d or/ó 10d (See table) (Vea la tabla) 10d (0.148" x 3") 3 16d or/ó 10d (See table) (Vea la tabla) 16d (0.162" x 3 1/2") Nails / Clavos Face / Cara Joist / Viga Sloped Only Hangers / Sólo Conectores Sesgados 1 1/2 LSSU28 10-10d 5-10dx1 1/2 1 1/2 LSSU210 10-10d 7-10dx1 1/2 2 1/2 LSSUH310 18-16d 12-10dx1 1/2 3 LSSU210-2 18-16d 12-10dx1 1/2 3 1/2 LSSU410 18-16d 12-10dx1 1/2 Skewed Hangers or Sloped and Skewed Conectores Sesgados o Con Sego y Pendiente 1 1/2 LSSU28 9-10d 5-10dx1 1/2 1 1/2 LSSU210 9-10d 7-10dx1 1/2 2 1/2 LSSUH310 14-16d 12-10dx1 1/2 3 LSSU210-2 14-16d 12-10dx1 1/2 3 1/2 LSSU410 14-16d 12-10dx1 1/2 Joist Width (in.) Ancho de Vigueta 52 Model Modelo N10HDG N8H " ral LUCZ N16 SS8D 2½" Spiral ss16D N54 (16DHDG (Included 16d similar size with3½" Header Joist Spiral N10HDG Sinker diffenrentN8HDG finish) SSN10 product) Viga cabezal Viga 1 2 SS10D (10DHDG similar size different fini SSN8 10d x 1 1/2" (0.148" x 1 1/2") 16d (0.162" x 3 1/2") 3 53 LUS 1 LUSIN1 2 LUSIN2 3 54 LUSIN3 LUS 16d x 2 1/2 (0.162 x 2 1/2) ss16D (16DHDG 10d Common 3½" similar size (0.148 x 3) diffenrent finish) Spiral 4 LUSIN4 10d for single 2x. 10d para un solo 2x (0.148" x 3"). 16d for all others. 16d para los demás (0.162" x 3½"). 5 LUSIN5 6 LUSIN6 55 16d Sinke SUR/L ss16D SS10D (16DHDG (10DHDG d 3½" 16d similar size similar size Spiral Sinker SSN8 diffenrent finish)SSN10 different finish) ) N10HDG N8HDG 3" Spiral N16 SS8D 2½" Spiral 1 10d x 1½" (0.148" x 1½") SUR-L-SSJ-IN-1 16d (0.162" x 3½") SUR-L-SSJ-IN-3 16d R-L-SSJ-IN-1 2 SUR-L-SSJ-IN-2 3SUR-L-SSJ-IN-5 56 SUR/L SUR-L-SSJ-IN-1 SUR-L-SSJ-IN-1 SUR-L-SSJ-IN-1 4 SUR-L-SSJ-I SUR-L-SSJ-IN-2 16d SUR-L-SSJ-IN-2 SUR-L-SSJ-I SUR-L-SSJ-IN-3 5 10d x 1½" SUR-L-SSJ-IN-4 SUR-L-SSJ-IN-3 SUR-L-SSJ-IN-4 SUR-L-SSJ-IN-3 SUR-L-SSJ-IN-5 10d x 1½" 6 SUR-L-SSJ-IN-5 SUR-L-SSJ-IN-5 57 SS10D VPA (10DHDG 6d 3" similar size N10HDG N8HDG nker Spiral SSN8 different finish) SSN10 N16 2½" Spiral SS8D N54 (Included with product) N10HDG N8H 10d 1 10d x 1½" (0.148" x 1½") Adjust to Required Required Pitch. Pitch Inclinación Inclinación Requerida. Requerida 10d (0.148" x 3") 2 10d 3 58 VPA 10d x 1½" 4 10d x 1½" 5 Solid Wood Madera Sólida I-Joist Vigueta 59 Engineered Wood & Structural Composite Lumber Connectors ITS The Strong-Grip™ seat allows the I-joist to “snap” in securely — no joist nails needed. El asiento Strong-Grip™ permite que la viga ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 90° 90° 1 See pages 12–14 for ITS-IN-1 more information. ITS-IN-2 Vea las páginas 12–14 para más información. ITS-IN-1 10d 10d 2 10d ITS-IN-2 10d 10d Common (0.148 x 3) 3 60 ITS-IN-5 ITS-IN-4 ITS-IN-2 ITS-IN-3 10d 10d ITS-IN-4 (0.148" x 3") ITS-IN-5 0° ITS ITS-IN-1 ITS-IN-2 ITS-IN-1 ITS-IN-2 ITS-IN- 10d 10d 90° -1 ITS-IN-2 ITS-IN-3 10d 10d 4 ITS-IN ITS-IN-4 ITS-IN-4 ITS-IN-5 ITS-IN-3 ITS-IN-2 10d 5 ITS-IN-5 No nails required in joist. No es necesario clavar clavos en la viga. 6 N-4 ITS-IN-5 ITS-IN-7 ITS-IN-6 ITS-IN ITS-IN-6 7 ITS-IN-7 ITS-IN-6 ITS-IN-6 ITS-IN-7 61 IUS The Strong-Grip™ seat allows the I-joist to “snap” in securely – no joist nails needed. El asiento Strong-Grip™ permite que la viga en ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 1 IUS_1 2 IUS_2 3 IUS_3 See pages 12–14 for more information. 10d Common (0.148 x 3) Vea las páginas 12–14 para más información. 10d (0.148" x 3") 62 4 IUS 5 IUS_4 6 No nails required in joist. No es necesario clavar clavos en la viga. 7 IUS_7 8 IUS_8 63 Plated Truss Connectors DTC 1 DTC-IN-1 DTC-IN-1 N54 (Included with product) N10HDG N8HDG SSN10 SSN8 Install nail in center of slot. Install nail in center of slot Instale Instale el clavo enel el centro la ranura clavodeen el 2 centro de la ranura. Install nail in center of slot Truss nails not Instale el clavo en el centro de la ranura driven Truss nails notflush. driven flush Los clavos de la cercha no deberían Los clavos de la asentarse contra el conector cercha no deberían asentarse contra el conector. Truss nails not driven flush Los clavos de la cercha no deberían asentarse contra el conector " iral 64 N16 SS8D 2½" Spiral DTC-IN-2 8d (0.131" x 2 1/2") DTC-IN-2 8D HTU 2½" Spiral N54 (Included with product) ss16D (16DHDG 16d x 2 1/2 10d Common 3½" similar size (0.162 x 2 1/2) (0.148 x 3) SSN8 diffenrent finish) N10HDG N8HDG SSN10 Spiral 16d 1 HTU-IN-1 HTU-IN-2 10d x 1 1/2" (0.148" x 1 1/2") HTU-IN-1 16d HTU-IN-2 2 HTU-IN-2 10d (0.148" x 3") For double HTU-IN-4 2x joists HTU-IN-2 HTU-IN-3 10d x 1 1/2" HTU-IN-3 16d (0.162" x 3 1/2") 3 HTU-IN-4 HTU-IN-4 5 4 10d x 1 1/2" HTU-IN-4 For double truss, use 10d x 3" nails into trusses. Para cerchas dobles, use clavos 10d x 3" insertados en las cerchas. 65 16d Sinke ral STC N16 SS8D 2½" Spiral N54 (Included with product) N10HDG N8HDG SSN10 SSN8 1 STC-IN-1 STC-IN-1 8d (0.131" x 1 1/2") 2 Gap Gap -IN-1 STC-IN-2 STC-IN-2 Install nail in center of slot. Instale el clavo en el centro de la ranura. Truss nails not driven flush. Los clavos de la cercha no deberían asentarse contra el conector. 66 THA Installation on Solid Header Instalación Sobre Viga Cabezal Sólida 2 1 THAIN2 Install joist nails both sides. THAIN3 Instale clavos para vigas a ambos lados. Face-Mount Condition / Condición de Montaje Sobre Cara Install joist nails both sides. SS8D 2 N10HDG N8HDG SSN10 SSN8 1 N54 (Included with product) HDG (10DHDG Spiral diffenrent finish) Sinker 16d r size similar size nt finish) Sinker different finish) different finish) 3" Spiral N16 Spiral N16 2½" Spiral (Included product) N10HDG N8HDG SSN10 Spiral SS8Dwith product) N10HDG N8HDG SSN10 SSN8 SSN8 Top-Mount Condition / Condición de Montaje Superior Instale clavos para vigas a ambos lados. 10d x 1 1/2" (0.148" x 1 1/2") 10d (0.148" x 3") 16d (0.162" x 3 1/2") 67 THA Installation on Solid Header Instalación Sobre Viga Cabezal Sólida Model Modelo Top & Face Carried Member Encima & Cara Miembro Soportado THA29 THA213 THA413 THA218 THA218-2 THA418 THA422 THA222-2 THA422-2 THA426 16-10d 4-10d 14-10d 4-10d 18-10d 4-10d 22-16d 6-16d 30-16d 6-16d Installation on Truss Instalación Sobre Cercha Nail Location Ubicación de Los Clavos Qty / Nail Cant./Clavo Top / Encima 4-16d Face / Cara 4-16d Carried Member Miembro soportado Fill all holes with 16d Llene todos los orificios con clavos 16d Installation on Nailer Instalación en Listón Clavador 68 Nail Location Ubicación de Los Clavos 4x Nailer / Listón Clavador 4x Top / Encima 4-16d Face / Cara 4-16d Carried Member Miembro soportado Fill all holes with 16d Llene todos los orificios con clavos 16d. Double 2x4 Top Chord Min. Viga Superior Doble de 2 x 4 Como Mínimo Top / Encima Face / Cara Straighten the double shear nailing tabs and install nails straight. Enderece las pestañas de clavado de doble penetración e instale los clavos rectos. Top / Encima Min. 4x Nailer Listón Clavador 4x Como Mínimo Face / Cara Straighten the double shear nailing tabs and install nails straight into the joist. Enderece las pestañas de clavado de doble penetración e instale los clavos rectos en la viga. THJA 16d 1 16d THJA-IN-1 THJA-IN-1 THJA-IN-2 THJA-IN-2 THJA-IN-1 THJA-IN-1 2 THJA-IN-2 THJA-IN-2 THJA-IN-1 THJA-IN-2 10d x 1½" THJA-IN-4 THJA-IN-4 THJA-IN-3 THJA-IN-3 THJA-IN-4 THJA-IN-4 4 SS8D 3 THJA-IN-3 10dTHJA-IN-3 x 1½" THJA-IN-3 THJA-IN-4 N16 Left Lefthand handhip hip installation installationsimilar similar Similar Similara alalainstalación instalación Left‘izquierda’ hand hip de Left hand hip ‘izquierda’ decumbre cumbre installation similar installation similar Similar a la ainstalación Similar la instalación ‘izquierda’ de cumbre ‘izquierda’ de cumbre Left hand hip installation similar Similar a la instalac ‘izquierda’ de cumb Left hand hip installation similar. THJA-IN-5 THJA-IN-5 Similar a la instalación ‘izquierda’ THJA-IN-5 deTHJA-IN-5 cumbre. 10HDG N8HDG SSN10 SSN8 THJA-IN-5 10d x 1½" (0.148" x 1½") 16d (0.162" x 3½") 69 1 2 THJU-IN-1 THJU-IN-1 THJU-IN-2 THJU-IN-2 THJU-IN-1 THJU-IN-1 THJU-IN-2 THJU-IN-2 THJU-IN-3 THJU-IN-3 THJU-IN-4 THJU-IN-4 3 4 THJU-IN-3 THJU-IN-3 THJU-IN-4 THJU-IN-4 16d Sinker similar size different finish) 3" Spiral N16 SS8D 2½" Spiral with product) N10HDG N8HDG SSN10 SSN8 THJU h) 70 10d (0.148" x 3") TSBR G N8HDG SSN10 SSN8 10d x 1 1/2" (0.148" x 1 1/2") 71 Masonry Connectors HETA 1 HETAIN1 2 HETAIN2 3 72 3" iral HETA N16 SS8D 2½" Spiral N54 (Included with product) N10HDG N8HDG SSN10 SSN8 10d x 1 1/2" (0.131" x 1 1/2") Quantity per Designer. 4 Cantidad según indicaciones del diseñador. HETAIN4 5 HETAIN5 73 LGT Fill holes with Titen® masonry screws. Llene los orificios con tornillos para mampostería Titen®. 1 LGT2 shown. LGT3 and LGT4 similar. LGT2-IN-1 For wood-to-wood connections using the LGT, visit www.strongtie.com. LG Se muestra LGT2. Similar a LGT3 y LGT4. Para conexiones de madera a madera usando el LGT, visite LGT2-IN-1 www.strongtie.com. 2 3⁄16" Drill bit Broca de 3⁄16" LGT2-IN-1 LGT2-IN-2 LGT2-IN-2 LGT2-IN-3 3 Compressed Air Aire comprimido (next page) (next page) LGT2-IN-3 LGT2-IN-3 Titen® Masonry Screw/Tornillo para mampostería (1/4" x 2 1/4") For installation in concrete, use Titen 1/4" x 1 3/4". 74 Para instalaciones en concreto, utilice Titen de 1/4" x 1 3/4". 3½" Spiral similar size diffenrent finish) 16d Sinker similar size different finish) 3" Spiral N16 SS8D 2½" Spiral with product) N10HDG N8HDG SSN10 SSN8 LGT 4 LGT2-IN-4 LGT2-IN-5 5 LGT2-IN-4 LGT2-IN-5 LGT2-IN-6 6 LGT2-IN-6 16d Sinker (0.148" x 3 1/4") 75 VGT V 1 If using an adhesive anchor, see pages 103–104 for instructions. 412 Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 103–104. Use 3⁄8" driver. 312 Use un destornillador de 3⁄8". VGT-IN-2 300 212 1⁄4" x 76 3" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw VGT VGT-IN-1 2 VGT-IN-2 3 VGT-IN-3 77 S8D Straps & Ties A35 1 1 A35IN2a A35IN1a 2 2 A35IN2b A35IN1b 2½" Spiral N54 (Included with A35IN2c product) 3 3 N10HDG N8HDG SSN10 SSN8 A35IN1c 4 A35IN2d 78 8d x 1 1/2 (0.131" x 1 1/2") 3½" piral ss16D ss16DSS10D ss16D SS10D SS10D (16DHDG (10DHDG (10DHDG 3½"- size -similar 16d 3"sizesimilar 16d3" 2½" similar size - 3½" 16d similar similar size size similar size SpiralSinker Spiral Sinker Spiral Sinker SpiralSpiral diffenrent finish) diffenrent different finish) finish) diffenrent finish) different finish) different finish N16 N16 SS8D CS/CMST14 (16DHDG (16DHDG (10DHDG 1 CS14 Shown Mostrado See chart for nail selection. Consulte la tabla para seleccionar los clavos. 8d (0.131" x 2 1/2") 10d (0.148" x 3") 2 16d (0.162" x 3 1/2") Sheathing not shown for clarity. No muestra el revestimento para mayor claridad. (CMST requires minimum 2-2x studs) (CMST requiere puntales de 2-2x como mínimo) 3 th ng d le En o del g Larremo ext ils re na he No uired a req cesit í ne qu Novos a cla th ng d le En o del g Larremo ext Provide min. 1⅝" end distance for CS and CMST Dejar al menos 1⅝" y distancia para CS y CMST Equal number of specified nails in each end Igual cantidad de clavos especificados en cada extremo 79 CS/CMST14 Sheathing not shown for clarity. Across joists No muestra el revestimento para mayor claridad. Sobre varias viguetas. Lumber Species / Especies de Madera Douglas Fir-Larch / Southern Pine Spruce-Pine-Fir / HemFir CSIN5 End End Model / Total Total Modelo Length / Cut Length / Fasteners / Length / Cut Length / Fasteners / Largo Largo Largo Largo Total de Total de del del a Cortar a Cortar Clavos Extremo Clavos Extremo CS14 CS14-R CS16 CS16-R CS18S CS18S CS18-R CS20 CS20-R CS22 CS22-R 16" Clear Span (Luz)+32" 30-8d 19" Clear Span (Luz)+38" 36-8d 15" Clear Span (Luz)+30" 26-10d 16" Clear Span (Luz)+32" 30-10d 13" Clear Span (Luz)+26" 22-8d 14" Clear Span (Luz)+28" 26-8d 11" Clear Span (Luz)+22" 20-10d 12" Clear Span (Luz)+24" 22-10d 11" Clear Span (Luz)+22" 18-8d 12" Clear Span (Luz)+30" 22-8d 9" Clear Span (Luz)+18" 16-10d 10" Clear Span (Luz)+24" 18-10d 9" Clear Span (Luz)+18" 14-8d 9" Clear Span (Luz)+18" 16-8d 6" Clear Span (Luz)+16" 12-10d 8" Clear Span (Luz)+16" 14-10d 6" Clear Span (Luz)+16" 14-8d 8" Clear Span (Luz)+20" 14-8d 5" Clear Span (Luz)+14" 12-10d 7" Clear Span (Luz)+18" 12-10d 30" Clear Span (Luz)+60" 66-10d 34" Clear Span (Luz)+76" 76-10d 26" Clear Span (Luz)+52" 56-16d 30" Clear Span (Luz)+66" 66-16d CMST14 NOTE: Install half of the total fasteners in each end of strap. Clear Span = Luz 80 NOTA: Instale la mitad de la cantidad total de sujetadores en cada extremo del fleje. H1 – Rafter/Cabrio 8d x 2 1/2" 1 N54 D ss16D SS10D (Included DG 6DHDG (10DHDG H1IN1 with ize - - 3" 16d lar size similar size - 2½" 3" SpiralSinkerN16different finish) Spiral finish) Spiral product) rent finish) N16 SS8D 8d x 1 1/2" N54 (Included with 2½" Rafter SSN10 Plate Spiral N10HDG N8HDG product) S Cabrio Placas SS8D 2 H1IN2 8d x 1 1/2" (0.131" x 1 1/2") 8d x 1 1/2" 8d (0.131" x 2 1/2") 3 H1IN3 H1 Reversed 4 H1 Invertido 81 H1IN4_Backward H1 – Truss/Viga 1 8d x 2 1/2" N54 (Included with product) N16 H1IN1_TRUSS N54 (Included with 2½" Truss SSN10 Plate Spiral N10HDG N8HDG product) SSN8 N10HDG N8HDG SSN10 Viga Placas SS8D 8d x 1 1/2" H1IN2_TRUSS 8d x 1 1/2" (0.131"x1 1/2") 8d (0.131" x 2 1/2") 3 8d x 1 1/2" H1IN3_TRUSS H1 Reversed H1 Invertido 4 H1IN4_TRUSS_Backward 82 2 SSN8 ½" iral H2.5A ss16D (16DHDG similar size diffenrent finish) SS10D (10DHDG similar size different finish) 16d Sinker 3" Spiral N16 SS8D 2½" Spiral 1 H2_5AIN1 Rafter Cabrio 2 8d (0.131" x 2 1/2") H2_5AIN2 Rafter Truss Viga 3 H2_5AIN2_TRUSS Installations in Pairs Both connectors shall be same model. Instalaciones en Pares Ambos conectores deben ser del mismo modelo. Wall Top Plate Placa superior de la pared Plan View Vista de Planta Install diagonally across from each other for minimum 2x truss. Instale diagonalmente uno respecto del otro para dejar una cercha de 2x como mínimo. 83 H2.5T N16 SS8D 2½" Spiral N54 (Included with product) N10HDG N8HDG SSN10 SSN8 1 H2_5IN1 Rafter Cabrio 2 8d (0.131" x 2 1/2") H2_5IN 2a RAFTER 3½" Truss Viga 3 H2_5T_INSTALLED Wall Top Plate Placa superior de la pared Products can be on the same side of the wall provided they are configured as shown. Los productos se pueden instala a ambos lados de la pared siempre que se configuren como se muestra. Plan View / Vista de Planta 84 H2_5A_TOPVIEW D DG ize finish) H10A – Rafter/Cabrio 3" Spiral N16 SS8D 2½" Spiral N54 (Included with product) N10HDG N8HDG SSN10 1 10d x 1 1/2" (0.148" x 1 1/2") H10AIN1 2 H10AIN2 3 H10AIN3 85 S H10A – Blocking/Entramado 3" piral N16 SS8D 2½" Spiral N54 (Included with product) 1 N10HDG N8HDG SSN10 H10AIN1 2 H10AIN4a 3 8d (0.131" x 2 1/2") H10AIN4b 4 H10AIN4c 5 86 H10AIN4d SSN8 LS 1a 1b LS50IN1a LS50IN1b 2a 2b LS50IN2a LS50IN2b 3a 3b 0HDG N8HDG SSN10 SSN8 LS50IN3ab LS50IN3b 10d x 1 1/2" (0.148" x 1 1/2") 87 LSTA 2⅜" Min. / Mínimo Bend strap one time only. Max 12/12 joist pitch. Doble las alas una vez. 1 LSTAIN1 2 Hanger not shown for clarity. 88 SSN8 HDG N8HDG SSN10 d x 2 1/2 62 x 2 1/2) 10d Common (0.148 x 3) 3 El soporte colgante no se muestra para ofrecer mayor claridad. 10d (0.148" x 3") 10d x 1 1/2" (0.148" x 1 1/2") For I-joist installation only. Sólo para instalación de vigas en ‘I’. ½" ral l LTP4/LTP5 ss16D (16DHDG 2½" 16d similar size Sinker diffenrent finish) Spiral N16 SS8D N54 SS10D (Included (10DHDG with size 3" 2½" similar product) finish) SpiralN8HDG Spiral N10HDG different N16SSN10 SSN8 SS8D LTP4IN_BLOCK_RIM 8d x 1 1/2" (0.131" x 1 1/2") FASTENERS: LTP4 No sheathing: 8d x 1 1/2" Over sheathing (3⁄8" thick max.): 8d x 2 1/2" 8d (0.131" x 2 1/2") LTP5 No sheathing: 8d x 1 1/2" Over sheathing (1⁄2" thick max.): 8d x 2 1/2" SUJETADORES: LTP4 Sin relleno: 8d x 1 1/2" Sobre relleno (3⁄8" de espesor máx.): 8d x 2 1/2" LTP5 Sin relleno: 8d x 1 1/2" Sobre relleno (1/2" de espesor máx.): 8d x 2 1/2" 89 MST ss16D 3½" Spiral (16DHDG similar size diffenrent finish) 16d Sinker SS10D (10DHDG similar size different finish) 3" Spiral 1 MSTIN1 16d (0.162" x 3 1/2") 3 N16 2 MSTIN2 No sheathing / Sin relleno End Length Largo Del Extremo CLEAR SPAN LUZ No nails required here No necesita clavos aquí End Length Largo Del Extremo MSTIN3 90 SS8D 2½" Spiral MST 3½" Spiral 1 ss16D (16DHDG similar size diffenrent finish) 16d Sinker 2 With sheathing / Con relleno MSTIN1a 3 MSTIN2a End Length Largo Del Extremo CLEAR SPAN LUZ 16d (0.162" x 3 1/2") No nails required here No necesita clavos aquí End Length Largo Del Extremo MSTIN3a 91 ral RBC N16 SS8D N54 (Included with product) 2½" Spiral N10HDG 1N8HDG SSN10 SSN8 RBC-IN-1 2 C-IN-1 RBC-IN-2 RBC-IN-1 RBC-IN-2 RBC-IN-2 10d x 1 1/2" (0.148" x 1 1/2") 3 Up to Hasta Up to Hasta RBC-IN-3 RBC-IN-4 4 92 3/4" Up to Up to Hasta Hasta 3/4" 3/4" 3/4" RBC-IN-4 RBC-IN-3 RBC h) RSP 3" Spiral N16 N54 (Included with product) 2½" Spiral RSP4-IN-1 SS8D RSP4-IN-2 N10HDG N8HDG SSN10 SSN8 1 RSP4-IN- RSP4-IN-1 8d x 11/2" (0.131" x 11/2") RSP4-IN-2 RSP4-IN-1 2 RSP4-IN-2 RSP4-IN-3 RSP4-IN-4 3 RSP4-IN-3 4 RSP4-IN-4 RSP4-IN-4 93 RSP4-IN-3 SP 10d Common (0.148 x 3) 1 10d (0.148" x 3") 2 94 SSP 16d x 2 1/2 (0.162 x 2 1/2) 10d Common (0.148 x 3) 1 Installation on mudsill / bottom plate similar. Instalación sobre durmientes / soleras similar. 2 10d (0.148" x 3") 3 Alternate with double top plate. Alterne con una placa superior doble. 95 16d inker (10DHDG similar size different finish) 3" Spiral N16 SS8D 2½" Spiral (Included with product) N10HDG N8HDG SSN10 SSN8 TSP 1 96 2 3 10d (0.148" x 3") Decking DTT1Z DTT1Z 1 2 3 3" Embedment 3" Empotramiento Strong-Drive® SDWH TIMBER-HEX HDG Screw #9 x 1 1/2" Strong-Drive® SD CONNECTOR Screw 97 DTT2Z 1 2" 2" 2 Threaded Rod Threaded Rod 3 1/4" x 1 1/2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 98 Miscellaneous Bend flanges one time only. Doble las alas una vez. HSS Bend flanges one time only. Doble las alas una vez. SDS25412HSS-IN-1 HSS-IN-2 flanges one time only. BendBend flanges one time only. 1 las alas Doble una vez. Doble las alas una vez. HSS-IN-1 HSS-I SDS25312 SDS25300 HSS-IN-1 HSS-IN-2 2 HSS-IN-1 HSS-IN-2 3 SDS25212 HSS-IN-3 HSS-IN-4 SDS25200 HSS-IN-3 HSS-IN-3 N-3 4 HSS-IN-4 HSS-IN-4 Use 3/8" driver. SDS25112 Use un destornillador de 3/8". 1/4" x 1 1/2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw HSS-IN-4 99 3½" piral ss16D PSPN (16DHDG similar size diffenrent finish) SS10D (10DHDG similar size different finish) 16d Sinker 3" Spiral PSPN-IN-1 1 PSPN-IN-1 PSPN-IN-1 PSPN-IN-1 PSPN-IN-2 2 PSPN-IN-2 PSPN-IN-2 PSPN-IN-2 16d (0.162" x 3 1/2") 3 PSPN-IN-3 4 PSPN-IN-3 PSPN-IN-3 PSPN-IN-3 PSPN-IN-4 100 N16 SS8D 2½" Spiral ½" iral ss16D TWB (16DHDG similar size diffenrent finish) 16d Sinker SS10D ss16D SS (10DHDG (16DHDG (10 16d 2½"simila similar size -3½" 3" similar size SpiralSpiral different finish) diffenrent finish) Sinker Spiral differe N16 SS8D 1 TWB_1 2 TWB_2 8d (0.131" x 2 1/2") at studs/ en los montantes 16d (0.162" x 3 1/2") at plates/ 3 en las soleras TWB_3 4 Cut 5/8" kerf. Corte un corte de 5/8". TWB_4 101 TWB (2) 16d 5 TWB_5 7 6 TWB_7 TWB_6 8 8d (2) 16d 102 TWB_8 Anchoring and Fastening Systems for Concrete and Masonry Adhesive Anchoring (AT-XP ® & SET-XP®) Anclaje Adhesivo Compressed air (80 psi min.), 4 seconds (min.) Aire comprimido (80 psi mín.), Adhesive Anchor 4 segundos (mín.) 1 Adhesive Anchoring-1 Adhesive Anchoring-1 2 Nylon brush 4 cycles (min.) Adhesive Anchoring-3 Cepillo de nailon 4 ciclos (mín.) 3 Fill 1/2 to 2/3 Llene 1/2 a 2/3 Adhesive Anchoring-3 Adhes Adhesive Anchor 103 Adhes Adhesive Anchoring Anclaje Adhesivo Compressed air (80 psi min.), 4 seconds (min.) Adhesive Anchoring-1Aire comprimido (80 psi mín.), Adhesive Anchor 4 segundos (mín.) Anchoring-1 4 Adhesive Anchoring-2 Dispense until uniform color Adhesive Anchoring-3 Anchoring-3 Adhesive Anchor Aplique hasta lograr un color uniforme. Adhesive Anchoring-4 Fill Fill 1/2 1/2toto2/32/3 Llene 1/2 a a2/32/3 Llene 1/2 5 Adhesive Anchoring-5 Fill 1/2 to 2/3 Llene 1/2 a 2/3 104 Anchoring-5 Adhesive Anchor 6 Adhesive Anchoring-6 Titen HD ® 1 Titen HD-IN-1 Titen HD-IN-1 Titen HD-IN-2 Titen HD-IN-2 2 Titen HD-IN-1 Titen HD-IN-1 Titen HD-IN-2 Washer or bearing plate as Titen HD-IN-2 required by building code. Arandela o disco de presión según lo requiera el código de construcción. 3 Titen HD-IN-4 Titen HD-IN-4 1/2" min. Titen HD-IN-3 Titen HD-IN-3 Titen HD-IN-3 Titen HD-IN-4 105 1/2" m Fastening Systems Strong-Drive® SDWC Truss Screw Metal Installation Guide Tool 1 Herramienta guía de instalación de metal Installation Guide Channel Canal de guía de instalación Step 1: - Align the metal installation guide tool (included) with the truss or rafter, and Metal drive the tip of the Strong-Drive SDWC to engage the threads. 2 Installation Step 2: - While continuing to drive the SDWC, “drop” the fasteners head into the guide Guide Tool channel to ensure optimal installation angle of 22.5º. The installation angle range is 10º-30º (see detail 1a). Once the installation angle is established, the metal installation Herramienta guide tool may be removed. guía de Installation Step 3:Guide - Drive the SDWC until the head of the fastener is fully countersunk into theinstalación double to plate. Verify that the entire shank of the fasteners is installed into a wood de metal Channel member. Canal de guía de instalación Optimal 22o o 10o 0 30 o 3 4 ½" Max. SDWC15600 SDWC15600 Installation Angle Limit Límite de ángulo para instalación Installation Angle Limit 5 106 SDWC15600 SDWC15600 3" Strong-Drive® SDWF Floor-to-Floor Screw 1 1.a 2 2"min. 1.b 3 1 TUW Take-Up Washer Arandela de recogida 1.c 4 Loca to Pest r Tab aña d el loc a lizad or Insid e Vista Wall V del m uro d iew esde dentr o 5 Ou Vista tside Wall del m uro d View esde afue ra SD #9 x 2 1/2" 107 Strong-Drive® SDWF Floor-to-Floor Screw SDWF Depth Guide (included) 6 Outsid Vista e del m Wall View uro d esde afuera 7 3¼ " Vista (U.S. 3½" Insid eW del m all V iew uro d esde afuera 5" SDW Paten F t 8,27 6,3 23) TUW (U.S. Patent 8,276,323) Upper-wall, bottom-plate splice shown Se muestra el empalme de placa inferior a muro superior F ve® SDWw un ong-Dri instalar One Str O-FLOOR screen Se debeentre 4" y 12" e -T e d FLOOR installed betwh o de ill torn uier lado a must be d 12" on eac all, en cualq palme de plac 4" an ny upper-w m e r ie erior. u p u lq . s a a e f u c ro c o li a mu side m-plate sp inferior botto 1" min. Rim Joist 108 . min 4" d ennce ta dis . min " 4 cia n a t dis orde al b Lower-wall, top-plate splice shown Se muestra el empalme de placa superior a muro inferior Typical Strong-Drive® SDWF FLOOR-TO-FLOOR and TUW Installation Notes/Notas 109 Notes/Notas 110 Notes/Notas 111 Every day we work hard to earn your business, blending the talents of our people with the quality of our products and services to exceed your expectations. This is our pledge to you. Nos esforzamos fuerte diariamente combinando el talento de nuestro personal con la calidad de nuestros productos y servicios excediendo sus expectativas para tenerlo a usted como cliente. Este es nuestro compromiso para con usted. (800) 999-5099 www.strongtie.com S-C-INSTALL16 4/16 exp. 6/18 © 2016 Simpson Strong-Tie Company Inc.
Documentos relacionados
WC-C-EWPBI13
The 33° collated structural-connector nail is designed to provide installers a pneumatic-driven alternative to hand-driven nails. The nail has been tested and approved for use in many popular Sim...
Más detalles