Hioki HPK-3
Professional HVAC/Electrical Contractor Kit


o



o




o








o






o




o





6 different items to aide the user with HVAC/Electrical work
Included in Kit:
FT3701-20 30:1 Infrared Thermometer
Pistol design with easy-to-see display
A full menu of basic measuring functions
Easy test in difficult locations, moving objects or where there is
danger of electric shock
3280-10 Clamp On Meter
1000A AC Current Capable
Lightweight
Independent Jaw Opening Design
Resistance and Continuity
Hioki 3129-10 Phase Rotation Meter for Thick Conductors
CAT III 1000V, CATIV 600V Safety through Non-Metallic-Contact
Testing
Detect phase with red LED signal rotation and buzzer
Auto Power Off
Voltage range: 70V to 1000V AC
Frequency: 45/66 Hz
Cord length: 0.7m
Clamp Diameter: 10 to 40 mm max.
Dimensions, mass: 70W x 75H x 30D mm, 220g
Hioki IR4056-20 Insulation Tester
5-range testing voltage 50 V/100 MΩ to 1000 V/4000 MΩ
Stable & medium-speed digital readings, response time at PASS/
FAIL decision 0.8 second
Drop proof onto concrete from 1m (3.28 feet)
Bright LED luminous LCD, Test lead with bright LED lamp to
illuminate near hand (Optional)
Continuity check via 200 mA testing
Built in AC/DC voltage meter, useful for testing solar power
generation systems and electric vehicles
Hioki 3120 Non-Contact Voltage Detector
Visual and audible indicators for non-contact voltage detection
Continually indicates battery status by green indicator lamp
Top "primary supply level" safety class rating for voltage detectors
CAT IV 600V design meets CE Mark qualifications
Automatic power switching prevents battery discharge
Hioki DT4281 Digital Multimeter
60,000 count, 5-digit display, high-resolution measurements
±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency
characteristics
Low-pass filter cuts high harmonics (when measuring inverter
fundamental waveforms)
Includes multiple measurement functions such as DC+ACV,
temperature, capacitance, and frequency
Includes terminal shutter mechanism for accident prevention
(prevents erroneous test lead insertion)
Hioki HPK-3 Shown



Measures large currents with optional clamp probe (only for DT4281,
which has no 10 A terminal for accident prevention)
USB communications function supports PC measurements
(optional)
Broad -15 (5°F) to 55°C (131°F) operating temperature range
Specifications
Range (0.06) - 42.00/42.0/1000A
AC Current
(50/60Hz) Accuracy ±1.5% reading + 5 digits
DC Voltage
Range
420.0m/4.200/42.00/420.0/600V
Accuracy ±1.3% reading + 4 digits
AC Current
Range 4.200/42.00/420.0/600V
(50 to
Accuracy ±2.3% reading + 8 digits
500Hz)
3280-10
Clamp On
Meter
Resistance
Range 420.0/4.20k/42.00k/420.0k/4.20M/42.00MΩ
(open
terminal
voltage 3.4V Accuracy ±2.3% reading + 8 digits
max)
Resistance
Range 420.0Ω (buzzer sounds at approx. 50Ω or less)
(open
terminal
Accuracy ±2.0% Reading + 6 digits
voltage
3.4V)
Function
Voltage Detection
Method
3129-10
Phase
Rotation
Meter
Voltage Range
Frequency Range
Safety
Clamp Diameer
(Insulated wiring)
IR4056-20
Insulation
Tester
Phase Detection (positive and negaive)
Electrosatic Induction Method
3-phase 70 to 1000V AC
(Continuous sine wave)
45 Hz to 66 Hz
CATIII 1000V, CAT IV 600V
10 to 40mm
DC voltage
measurement
4.2V (0.001V resolution) to 600V (1V resolution), 4 ranges, Accuracy: ±1.3%
rdg. ±4 dgt., Input resistance: 100 kΩ or higher
AC voltage
measurement
420V (0.1V resolution) / 600V (1V resolution), 2 ranges, 50/60 Hz, Accuracy:
±2.3% rdg. ±8 dgt., Input resistance: 100 kΩ or higher, Average rectifier
Low resistance
measurement
For checking the continuity of ground wiring, 10 Ω (0.01 Ω resolution) to 1000
Ω (1 Ω resolution), 3 ranges, Basic accuracy: ±3 % rdg. ±2 dgt., testing
current 200 mA or more (at 6 Ω or less)
Display
Semi-transmissive FSTN LCD with back lighting, bar-graph indicator
Response time
Approx. 0.8 second for PASS/FAIL decision (at HIOKI's conditions)
Other functions
Live circuit indicator, Automatic electric discharge, Automatic DC/AC
detection, Comparator, Drop proof, Auto power save
DC Voltage
60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage
(45 to 65 Hz)
DC + AC Voltage
(45 to 65 Hz)
DT4281
Digital
Multimeter
60.000 mV to 1000.0 V, 6 ranges,
Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance
60.000 Ω to 600.0 MΩ, 8 ranges
Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC Current
600.00 μA to 600.00 mA, 4 ranges
Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC Current
(45 to 65 Hz)
10.00 A to 1000 A, 7 ranges
Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt.
(True RMS, crest factor 3)
AC Current
10.00 A to 1000 A, 7 ranges
(use with the Clamp on
Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt.
probe)
(True RMS, crest factor 3)
40 to 1kHz