Hioki HPK-3 Professional HVAC/Electrical Contractor Kit
Transcripción
Hioki HPK-3 Professional HVAC/Electrical Contractor Kit
Hioki HPK-3 Professional HVAC/Electrical Contractor Kit o o o o o o 6 different items to aide the user with HVAC/Electrical work Included in Kit: FT3701-20 30:1 Infrared Thermometer Pistol design with easy-to-see display A full menu of basic measuring functions Easy test in difficult locations, moving objects or where there is danger of electric shock 3280-10 Clamp On Meter 1000A AC Current Capable Lightweight Independent Jaw Opening Design Resistance and Continuity Hioki 3129-10 Phase Rotation Meter for Thick Conductors CAT III 1000V, CATIV 600V Safety through Non-Metallic-Contact Testing Detect phase with red LED signal rotation and buzzer Auto Power Off Voltage range: 70V to 1000V AC Frequency: 45/66 Hz Cord length: 0.7m Clamp Diameter: 10 to 40 mm max. Dimensions, mass: 70W x 75H x 30D mm, 220g Hioki IR4056-20 Insulation Tester 5-range testing voltage 50 V/100 MΩ to 1000 V/4000 MΩ Stable & medium-speed digital readings, response time at PASS/ FAIL decision 0.8 second Drop proof onto concrete from 1m (3.28 feet) Bright LED luminous LCD, Test lead with bright LED lamp to illuminate near hand (Optional) Continuity check via 200 mA testing Built in AC/DC voltage meter, useful for testing solar power generation systems and electric vehicles Hioki 3120 Non-Contact Voltage Detector Visual and audible indicators for non-contact voltage detection Continually indicates battery status by green indicator lamp Top "primary supply level" safety class rating for voltage detectors CAT IV 600V design meets CE Mark qualifications Automatic power switching prevents battery discharge Hioki DT4281 Digital Multimeter 60,000 count, 5-digit display, high-resolution measurements ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms) Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency Includes terminal shutter mechanism for accident prevention (prevents erroneous test lead insertion) Hioki HPK-3 Shown Measures large currents with optional clamp probe (only for DT4281, which has no 10 A terminal for accident prevention) USB communications function supports PC measurements (optional) Broad -15 (5°F) to 55°C (131°F) operating temperature range Specifications Range (0.06) - 42.00/42.0/1000A AC Current (50/60Hz) Accuracy ±1.5% reading + 5 digits DC Voltage Range 420.0m/4.200/42.00/420.0/600V Accuracy ±1.3% reading + 4 digits AC Current Range 4.200/42.00/420.0/600V (50 to Accuracy ±2.3% reading + 8 digits 500Hz) 3280-10 Clamp On Meter Resistance Range 420.0/4.20k/42.00k/420.0k/4.20M/42.00MΩ (open terminal voltage 3.4V Accuracy ±2.3% reading + 8 digits max) Resistance Range 420.0Ω (buzzer sounds at approx. 50Ω or less) (open terminal Accuracy ±2.0% Reading + 6 digits voltage 3.4V) Function Voltage Detection Method 3129-10 Phase Rotation Meter Voltage Range Frequency Range Safety Clamp Diameer (Insulated wiring) IR4056-20 Insulation Tester Phase Detection (positive and negaive) Electrosatic Induction Method 3-phase 70 to 1000V AC (Continuous sine wave) 45 Hz to 66 Hz CATIII 1000V, CAT IV 600V 10 to 40mm DC voltage measurement 4.2V (0.001V resolution) to 600V (1V resolution), 4 ranges, Accuracy: ±1.3% rdg. ±4 dgt., Input resistance: 100 kΩ or higher AC voltage measurement 420V (0.1V resolution) / 600V (1V resolution), 2 ranges, 50/60 Hz, Accuracy: ±2.3% rdg. ±8 dgt., Input resistance: 100 kΩ or higher, Average rectifier Low resistance measurement For checking the continuity of ground wiring, 10 Ω (0.01 Ω resolution) to 1000 Ω (1 Ω resolution), 3 ranges, Basic accuracy: ±3 % rdg. ±2 dgt., testing current 200 mA or more (at 6 Ω or less) Display Semi-transmissive FSTN LCD with back lighting, bar-graph indicator Response time Approx. 0.8 second for PASS/FAIL decision (at HIOKI's conditions) Other functions Live circuit indicator, Automatic electric discharge, Automatic DC/AC detection, Comparator, Drop proof, Auto power save DC Voltage 60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt. AC Voltage (45 to 65 Hz) DC + AC Voltage (45 to 65 Hz) DT4281 Digital Multimeter 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3) 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz Basic accuracy: ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3) Resistance 60.000 Ω to 600.0 MΩ, 8 ranges Basic accuracy: ±0.03 % rdg. ±2 dgt. DC Current 600.00 μA to 600.00 mA, 4 ranges Basic accuracy: ±0.05 % rdg. ±5 dgt. AC Current (45 to 65 Hz) 10.00 A to 1000 A, 7 ranges Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt. (True RMS, crest factor 3) AC Current 10.00 A to 1000 A, 7 ranges (use with the Clamp on Add the Clamp on probe accuracy to Basic accuracy: ±0.6 % rdg. ±2 dgt. probe) (True RMS, crest factor 3) 40 to 1kHz