CD-PLUS/4+N
24 Protocol converter CD-PLUS/4+N Instructions manual TCD-PLUS4N ML rev.0108 25 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar. The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one. Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual. SYSTEM CHARACTERISTICS O A protocol converter for the PLUS system, which permits the following combinations: ÜIn systems with PLUS installations, it allows an IT-4N telephone interface connection. ÜIn systems with PLUS installations, it allows the connection of announcement systems or PABXs that are compatible with 4+n installations. O With an FA-Plus/C power supply the maximum number of converters and telephones in one installation is 10, and with an FA-Plus, the maximum is 50. O It requires programming but there is no need for it to be configured. O Autodiagnostic LEDs which allow the detection of programming errors. OPERATION MODES The CD-PLUS/4+N converter has 2 possible operation modes: Connection to an IT-4N telephone interface It allows an IT-4N telephone interface connection to an audio or video door entry system with Plus installation, performing the normal functions of this interface: receive and answer calls from the door panel on any telephone in the apartment, door open function, diverting of calls from the door panel to any telephone number (fixed or cellular), etc.. Plus Monitors NOTE: Nothing should be installed between the converter and the interface as this could cause inadequate operation. 1 2 4 3 5 7 * 6 8 9 0 # IT-4N CD-PLUS/4+N Telephone line 4+n 4 TF-104 3 + coax 4 + twisted pair PLUS door panel Lock release 2 FA-Plus 2 PLUS door panel Lock release 2 FA-Plus 2 To other door panels 2+coax 3+twisted pair 2 26 OPERATION MODES Connection to 4+N compatible systems It allows the connection of systems that are compatible with 4+n installations (announcement systems, PABXs, etc.), to audio or video door entry systems with Plus installations. NOTES: FA T/700 telephone (or equivalent) should be connected to the converter's 4+n connection block for its programming, once programmed this telephone should be disconnected. FOnly one function per converter is admitted, if more functions are needed then install the corresponding amount of converters while keeping in mind the power supply limitations. FSometimes a reduction in functionality can occur depending on the manufacturer of the system to be installed, or even more rarely, there could be unexpected results. Example with an announcement system Plus Monitors ANNOUNCEMENT SYSTEM CONTROL UNIT APARTMENT'S ANNOUNCEMENT SYSTEM CD-PLUS/4+N INTERFACE 4+N 4+n 4 3 + coax 4 + twisted pair PLUS door panel PLUS door panel Lock release FA-Plus 2 Lock release 2 FA-Plus 2 2 To other door panels 2+coax 3+twisted pair Example with a PABX Plus Monitors 1 2 4 3 5 7 6 8 * 9 0 # PABX PSTN CD-PLUS/4+N 1 2 4 3 5 7 6 8 * 9 0 # INTERFACE 4+N 1 2 4 3 5 7 * 6 8 4+n 9 0 # 4 3 + coax 4 + twisted pair PLUS door panel Lock release PLUS door panel FA-Plus 2 Lock release 2 FA-Plus 2 To other door panels 2+coax 3+twisted pair 2 27 DESCRIPTION D escription of the converter. DIN rail latch release Autodiagnostic LEDs Connection block D escription of the autodiagnostic LEDs. The autodiagnostic LEDs are placed next to the configuration dip switch. Green LED Fixed: Correct operation. Slow blinking: Programming activated. Quick blinking: Programming finished. Red LED Fixed: Programming error, go through the steps from the beginning. Off: Correct operation INSTALLATION D etail of the converter installation. The converter can be installed on a DIN guide (6 elements) by lightly pressing it. To extract the converter from the DIN guide, use a plain screwdriver to lever the flange as shown on the picture. DIN 46277 f3,5 x 45 DIN-7971 To install the converter directly on the wall, drill two holes of Ø6mm. and insert the wallplugs. Fix the transformer with the specified screws. Install the converter in a dry and protected place. f3,5 x 45 DIN-7971 28 PROGRAMMING P rogramming the converter. For the correct operation of this system it must be programmed as indicated in the following instructions: Programming methods With an IT-4N telephone interface With the telephone connected to the output line to telephones of the IT-4N telephone interface. 3 1 1 4 7 * 1 4 7 * 1 2 3 5 6 8 9 0 # 2 3 5 6 8 9 0 # Master 5 Access the door panel programming mode. If it is a door panel with pushbuttons set dip switch no. 2 from the EL 500 module to ON, and if it is a coded panel press the key button followed by the installer Pin (from factory: 1315). Enter “##9” code with the telephone buttons to access the programming mode of the Plus/4N Converter. 3 6 9 # To show that the system is ready for programming, the door panel and handset will emit a tone, audio communication is established and the green LED on the protocol converter will blink slowly. 3 6 9 # Press the door panel push button that will call this converter, or in the case of a coded door panel, enter the apartment code and press the button . At this moment the door panel and handset will emit tones and the converter's green LED will blink quickly. 1 4 7 * 2 3 5 6 8 9 0 # With the handset lifted: If programming the converter as master, replace the handset. If programming it as slave, press push button 5 and finally, replace the handset. Slave ÜThe converter should be programmed as slave when it is installed in an apartment with a monitor. ÜEach apartment must have one master unit only; in case of parallel units configure them as slaves, whether they are monitors, telephones or converters. The programming of the converter is complete. ÜMake a call to check that it has been successfully programmed. ÜHaving completed the programming set the Door panel's programming switch to OFF, or exit the configuration mode (coded panel) by pressing the C button. 29 PROGRAMMING P rogramming the converter. For the correct operation of this system it must be programmed as indicated in the following instructions: Programming methods With an IT-4N telephone interface (Divert Mode Always Enabled) Without the telephone being connected to the output line to telephones of the IT-4N telephone interface. 3 1 1 4 7 * 1 4 7 * 1 From a telephone on the PABX, call the IT-4N extension and establish audio communication. Enter “##9” code to access the programming mode of the CD-PLUS/4N protocol converter. (In the case of a coded door panel you have 10 seconds to enter this code starting from the moment communication has been established). 2 3 5 6 8 9 0 # 2 3 5 6 8 9 0 # Master 5 Access the door panel programming mode. If it is a door panel with pushbuttons set dip switch no. 2 from the EL 500 module to ON, and if it is a coded panel press the key button followed by the installer Pin (from factory: 1315). 3 6 9 # To show that the system is ready for programming, the door panel and handset will emit a tone, and the green LED on the protocol converter will blink slowly. 3 6 9 # Press the door panel push button that will call this converter, or in the case of a coded panel, enter the apartment code and press the button . At this moment the door panel and handset will emit tones and the converter's green LED will blink quickly. 1 4 7 * 2 3 5 6 8 9 0 # Slave With the handset lifted: If programming the converter as master, press the “ ” push button * and replace the handset. If programming it as slave, press push button 5 followed by push button “ ” and finally, replace the handset. * ÜThe converter should be programmed as slave when it is installed in an apartment with a monitor. ÜEach apartment must have one master unit only; in case of parallel units configure them as slaves, whether they are monitors, telephones or converters. The programming of the converter is complete. ÜMake a call to check that it has been successfully programmed. ÜHaving completed the programming set the Door panel's programming switch to OFF, or exit the configuration mode (coded panel) by pressing the C button. 30 PROGRAMMING P rogramming the converter. For the correct operation of this system it must be programmed as indicated in the following instructions: Programming methods Without an IT-4N telephone interface Connect a T-700 telephone (or equivalent) to the converter's 4+n connection block following the terminal correspondences (3, 10, 5, 0 and P1). 1 3 1 5 Access the door panel programming mode. If it is a door panel with pushbuttons set dip switch no. 2 from the EL 500 module to ON, and if it is a coded panel press the key button followed by the installer Pin (from factory: 1315). With the door release push button pressed, lift the handset off the telephone. To show that the system is ready for programming, the door panel and handset will emit a tone, and audio communication can be established. Release the door release push button. Press the door panel push button that will call this converter, or in the case of a coded panel, enter the apartment code and press the button . At this moment both door panel and handset will emit tones. With the handset lifted: To program the converter as master, replace the handset, and to program it as slave, press the door release push button and finally, replace the handset. Master Slave ÜThe converter should be programmed as slave when it is installed in an apartment with a monitor. ÜEach apartment must have one master unit only; in case of parallel units configure them as slaves, whether they are monitors, telephones or converters. The programming of the converter is complete. ÜMake a call to check that it has been successfully programmed. ÜHaving completed the programming set the Door panel's programming switch to OFF, or exit the configuration mode (coded panel) by pressing the C button and disconnect the T-700 telephone from the converter. 31 CONNECTIONS C onnection to an IT-4N telephone interface. TF-104 PRI IT-4N SEC ~ ~ ~ ~ 3 P1 10 5 0 M PD DA RA RB LA LB PA PB Telephone Main Telephone line BUS 4+N 3 Monitor or Plus telephone 5 10 0 P1 CD-PLUS/4+N + _ A D BUS PLUS + A VP D VP Malla MP MP + SA To door panel C onnection to 4+N compatible systems. INTERFACE 4+N BUS 4+N 3 ANNOUNCEMENT SYSTEM CONTROL UNIT OR PABX Monitor or Plus telephone 5 10 0 P1 CD-PLUS/4+N + _ A D BUS PLUS + A D VP VP Malla MP MP + SA To door panel 32 OPTIONAL CONNECTIONS A dditional call repeater connection. BUS 4+N 3 5 10 0 P1 Monitor or Plus telephone CD-PLUS/4+N SAV-90 BUS PLUS + A D VP VP Malla MP MP + SA + _ A D + SA To door panel V ideo signal shunt. If it were necessary, the MP and VP terminals can be used as a shunt (input-output) for the video signal. Keep in mind that this module does not handle this signal; it just acts as a shunt so that it can continue to the next point. Twisted pair BUS 4+N 3 Coaxial BUS 4+N 5 10 0 P1 3 CD-PLUS/4+N CD-PLUS/4+N BUS PLUS + A 5 10 0 P1 BUS PLUS D VP VP Malla MP MP + SA + A D VP VP Malla MP MP + SA CN4 D1 SEC + + - - FA-Plus or FA-Plus/c rev.938072. Main ~ ~ * PRI FA-Plus or FA-Plus/c NOTE: Place this power supply as close as possible to the first distributor. + _ Vin Malla Vout A D E + JP1 D2 CN4 1 2 JP 3 4 + A BUS PLUS BUS 4+N CN1 CV- CV+ - + D Aout Ain Vin- Vin+ Malla Vout+ Vout- SW1 Master door panel + _ Vin Malla Vout A D Main 5 10 0 P1 VP VP Malla MP MP + SA 3 0 M PD DA RA RB LA LB PA PB SAV-90 Additional call repeater output Input for enabling/disabling call diverting 12Vcc / 40mA Divert enabled output 30Vcc/Vca 1A Relay Output Telephone line (Subscriber loop) Output to telephones (Local subscriber loop) RG-59 0.25mm² 1.00mm² RG-59 0.25mm² 2.50mm² 150m. Distance 50m. For greater distances, please consult with our technical support department. Vin+, Vout+, Vin, Vout Ain, Aout, A, D +, –, CV+, CV– Terminal SECTIONS CHART Refer to the IT-4N document for its programming and start-up. D CD-PLUS/4+N 3 P1 10 5 IT-4N C S ~ ~ ~ ~ PRI SEC * D4L-PLUS TF-104 INSTALLATION DIAGRAMS 33 onnecting a video door entry system to an IT-4N interface using coaxial cable. * * JP 3 4 CV- CV+ - + D Aout Ain Vin- Vin+ Malla Vout+ Vout- 2 + + - - 1 CN1 SW1 Master door panel + A BUS PLUS BUS 4+N SEC + _ A D Vpi Mpi A D CT + _ Md6 Vd6 Main CD-PLUS/4+N 3 5 10 0 P1 SA 3 0 M PD DA RA RB LA LB PA PB SAV-90 Additional call repeater output Input for enabling/disabling call diverting 12Vcc / 40mA Divert enabled output 30Vcc/Vca 1A Relay Output Output to telephones (Local subscriber loop) Telephone line (Subscriber loop) 150m. CAT-5 0.25mm² 2.50mm² IMPORTANT: For this type of installation, the door panels must have plugged an EL560 module in each and the monitors must have an EL562 plugged in each. For greater distances, please consult with our technical support department. CAT-5 0.25mm² Ain, Aout, A, D Vin+,-, Vout+,-, Vp,d, Mp,d 1.00mm² 50m. Distance +, –, CV+, CV– Terminal SECTIONS CHART Refer to the IT-4N document for its programming and start-up. + P1 10 5 D VP VP Malla MP MP * FA-Plus or FA-Plus/c rev.938072. Main ~ ~ * PRI FA-Plus or FA-Plus/c NOTE: Place this power supply as close as possible to the first distributor. A D CT JP1 D6L-Plus/2H PRI SEC * ~ ~ ~ ~ IT-4N C + _ + _ A D Vpo Mpo + _ A D Vp Mp + _ A D Vp Mp Md1 Vd1 EL562 JP1 EL562 JP1 TF-104 34 INSTALLATION DIAGRAMS onnecting a video door entry system to an IT-4N interface using twisted pair cable. * TROUBLESHOOTING HINTS 35 ONothing operates. w Check that the voltage between the + and - terminals of the converter is between 17.5 to 18.5Vc.c., if not, check the power supply and its connections. w Connect a T-700 telephone (or equivalent) to the converter's 4+n connection block and check that it works correctly. w If it does, then check the configuration of the unit that is connected to the 4+n connection block. w If it does not, check that the programming has been done correctly. Reprogram it if necessary. ONot receiving calls. w Check that the unit connected to the 4+n connection block supports electronic calls and that it is configured for this. w Check that the programming has been done correctly. Reprogram it if necessary. CONFORMIDAD/COMPLIANCE/CONFORMITÉ Este producto es conforme con las disposiciones de las Directivas Europeas aplicables respecto Compatibilidad Electromagnética 89/336/CEE, así como con la ampliación en la Directiva del Marcado CE 93/68/CEE. This product meets the essentials requirements of applicable European Directives regarding Electromagnetic Compatibility 89/336/ECC, and as amended for CE Marking 93/68/ECC. NOTA: El funcionamiento de este equipo está sujeto a las siguientes condiciones: (1) Este dispositivo no puede provocar interferencias dañinas, y (2) debe aceptar cualquier interferencia recibida, incluyendo las que pueden provocar un funcionamiento no deseado. NOTE: Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any received interference, including the ones that may cause undesired operation. [email protected] www.golmar.es Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.