Seismic application Cellules pour risques sismiques Aplicación
Seismic application Spacial SF Main characteristics General overview Around the world can be found different zones with a specific seismic risk. These zones have been classified according to the Uniform Building Code (UBC). zone 4 zone 3 zone 2 zone 1 PB501884 zone 0 Spacial SF seismic solutions Schneider Electric offers a range of LV earthquake resistant floor-standing switchboards. The Spacial range is among these, with an answer to each type of project for different seismic risk zones. From weak to strong earthquakes: • Automation & Control switchboards. The standard Spacial SF with dimensions 2000 H 3 800 W 3 600 D has been tested to guarantee the right performance on seismic risk up to UBC zone 3. • Industrial 19" Electronic applications. Standard Spacial SF with dimensions 2000 H 3 600 W 3 800 D and with a 19" fixed rack configuration suitable for seismic risk up to UBC zone 3. • LV power distribution up to 3200A. Standard Spacial SFP is tested to perform up to UBC zone 3. For very strong earthquakes: • Automation & Control and 19" rack applications. Spacial SF 5G performs up to UBC zone 4 thanks to its reinforced structure, special panel fixation and locking system. • LV power distribution up to 3200 A. Spacial SFP 5G performs up to UBC zone 4, also thanks to its reinforce structure, special panel fixation and locking system. All tests have been performed according to the following technical regulations: • EDF CRT 91 C 112 00, Nuclear. EDF (French Electricity Board) technical specification. • IEC 61587-2, 60917 & 60297-2. Weak to Strong Spacial SF (2000 3 800 3 600) OK Spacial SF 19" (2000 3 800 3 600) OK Very Strong Spacial SFP OK Spacial SF 5G OK Spacial SFP 5G IEC 60068-3-3 Ground aceleration reference OK Seismic characteristics General description g m/s AG2 Intensity from weak to average 2 > 5.5 AG3 Intensity from average to strong 3 5.5 to 7.0 2-3 VIII to IX AG5 Intensity from strong to very strong 5 > 7.0 4 > IX Richter scale UBC magnitude Zone MSK Intensity** 0 > VIII 1 * Aproximate value of the Uniform Building Code Zone. ** MSK (Medvedev-Sponheuer-Kamik corresponding to the intensity scale Mercalli modified). 2 version: 2.0 SFM084.indd Seismic application Spacial SF Standard Spacial SF Standard Spacial SF Two configuration of the standard Spacial SF have been tested: • Automation & Control configuration. 150 kg dummy load installed on mounting plate and homogeneously distributed, according to IEC 61587-2. • 19" fixed rack configuration. 150 kg dummy load installed on a 19" fixed rack, homogeneously distributed, according to IEC 61587-2. Nominal dimensions Plain door Additional dummy load With mounting Without Height Width Depth tested (kg) plate mounting plate Side panels Plinth 100 (mm) Front panel Side panel Mounting plate A&C Configuration 2000 800 600 150 NSYSF20860P NSYSF20860 NSY2SP206 NSYSPF8100 NSYSPS6100 NSYMP208 19" Configuration 2000 600 800 150 - NSYSF20680 NSY2SP208 NSYSPF6100 NSYSPS8100 - 19" Rack NSYRCK42 Compliance with local standards Standard Standard EDF CRT91C11200 Level and specifications of the standard 60% of the ensemble response spectrum: 3 g peak and 0.6 g ZPA* AS1170 Australia Soil Type: Ee / Floor zero EAK 2000 Greece Soil Type: D (delta) Seismic importance factor: gi = 0.85 Ground acceleration factor: a = 0.12 Foundation factor: q = 1 Quality factor = 1.35 Spectral amplification factor: b0 = 2.5 ENDESA 1986 Seismic Category A 5% damping Ground acceleration = 0.5 g RPA 99 2003 Algeria Soil type: S4 5% damping Ground acceleration factor A = 0.15 Behaviour factor = 2 Quality factor z = 1.35 Gore GR 63 5% damping Zone 3 Turkish Seismic Code 2009 GOST 17516.1-90 Russia Site Class: Z4 5% damping Importance factor = 1.5 Ground acceleration factor: A0 = 0.4 Civil market standardl MSK (Mercalli) intensity 9, level 2: envelope epectra CRT91C11200 * ZPA - Zero Period Acceleration. SFM084.indd version: 2.0 3 Seismic application Spacial SF Standard Spacial SFP Standard Spacial SFP Two configuration of standard Spacial SFP have been tested. Functional systems have been installed on the switchboard and checked at the end of the test to verify that there was no damage. The 2 tested configurations are: • 1600 A configuration. • 3200 A configuration. Nominal dimensions 1600 A configuration 3200 A configuration Height Width Depth Additional dummy load (kg) Plain door Side panels NSY2SP205 Spacial SFP 2000 700 500 350 NSYSFP20750 Busbar duct 2000 300 500 350 NSYSF20350 NSY2SP205 Spacial SFP 2000 700 800 450 NSYSF20780 NSY2SP208 Busbar duct 2000 300 800 450 NSYSF20380 NSY2SP208 Compliance with local standards Standard Level and specifications of the standard Standard EDF CRT91C11200 71% of the ensemble response spectrum: 3.5 g peak and 0.71 g ZPA* AS1170 Australia Soil Type: Ee / Floor zero EAK 2000 Greece Soil Type: D (delta) Seismic importance factor: gi = 0.85 Ground acceleration factor: a = 0.12 Foundation factor: q = 1 Quality factor = 1.35 Spectral amplification factor: b0 = 2.5 ENDESA 1986 Seismic Category A 5% damping Ground acceleration = 0.5 g RPA 99 2003 Algeria Soil type: S4 5% damping Ground acceleration factor A = 0.15 Behaviour factor = 2 Quality factor Q = 1.35 Gore GR 63 5% damping Zone 3 Turkish Seismic Code 2009 GOST 17516.1-90 Russia Site Class: Z4 5% damping Importance factor = 1.5 Ground acceleration factor: A0 = 0.4 Civil market standardl MSK (Mercalli) intensity 9, level 2: envelope epectra CRT91C11200 * ZPA - Zero Period Acceleration. 4 version: 2.0 SFM084.indd Seismic application Spacial SF Spacial SF 5G Spacial SF 5G & Spacial SFP 5G Spacial SF 5G and Spacial SFP 5G have been designed to withstand earthquakes up to UBC zone 4. The two tested configurations, automation & control and LV power distribution, enable it to be certified for nuclear applications. This new design is based on the following principles: PB501885 Reinforced cross • Two reinforced crosses guarantee the mechanical withstand of the structure. PB501886 Panel fixations • Fixation systems that avoid loosening of screws. PB501888 PB501887 Security locking system • EDF-certified seismic locking system. • Specific bars and handle to avoid accidental door opening under severe vibration conditions. PB501889 Reinforced plinths • New monoblock reinforced plinths. SFM084.indd version: 2.0 5 Seismic application Spacial SF Spacial SF 5G Spacial SF 5G Same characteristics as the Spacial SF but with the upgrades already mentioned. Nominal dimensions Plain door Height Width Depth Additional dummy load tested (kg) A&C Configuration 2000 800 600 150 - 19" Configuration 2000 600 800 150 - Plinth 100 (mm) Mounting plate 19" Rack NSYSF5G20860 NSY5G2SP206 NSYS5GPC86 NSYMP208 - NSYSF5G20680 NSY5G2SP208 NSYS5GPC68 - NSYRCK42 With mounting With out plate mounting plate Side panels Spacial SFP 5G Same characteristics as the Spacial SFP but with the upgrades already mentioned. Spacial SFP 2000 700 500 Additional dummy load (kg) 350 NSYSFP5G20750 NSY5G2SP205 Busbar duct 2000 300 500 350 NSYSF5G20350 NSY5G2SP205 NSYS5GPC35 Spacial SFP 2000 700 800 450 NSYSF5G20780 NSY5G2SP208 NSYS5GPC78 Busbar duct 2000 300 800 450 NSYSF5G20380 NSY5G2SP208 NSYS5GPC38 Nominal dimensions 1600 A configuration 3200 A configuration Height Width Depth Plain door Side panels Plinth 100 (mm) NSYS5GPC75 Important: Spacial SFP 5G 300 mm width for busbar duct purpose is not compatible with Spacial SF 5G. Compliance with local standards Standard Standard EDF CRT91C11200 AS1170 Australie All type of soil class / Floor zero EAK 2000 Greece All type of soil class (delta) Seismic importance factor: gi = 1.3 Ground acceleration factor: a = 0.36 Foundation factor: q = 1 Quality factor = 1.35 Spectral amplification factor: b0 = 2.5 ENDESA 1986 All seismic category Ground acceleration = 0.5 g RPA 99 2003 Algeria All type of soil class Ground acceleration factor A = 0.36 Behaviour factor R = 2 Quality factor Q = 1.35 Gore GR 63 Zone 4 with a factor 0.8 for the vertical severity relating to the horizontal severity Turkish Seismic Code 2009 GOST 17516.1-90 Russia IEEE 693 6 Level and specifications of the standard General response spectrum: - ZPA = 1 g in horizontal & maximum aceleration = 5 g. - ZPA = 0.8 g in vertical & maximum aceleration = 4 g. version: 2.0 All type of site class Importance factor = 1.5 Ground acceleration factor: A0 = 0.4 Civil market: MSK (Mercalli) intensity 9, level 2 Nuclear market: - MSK (Mercalli) intensity 9, level 0. - MSK (Mercalli) intensity 8, level 2. High Level SFM084.indd Spacial SF Seismic application Spacial SF 5G Reinforcement kits for Spacial SF 5G In case the following mounting components are used inside the SF 5G: • Plain mounting plates • 19" fixed rack then it is mandatory to mount the corresponding reinforcement kits, in order to guarantee safety and maximum performance of the enclosure and of the equipment installed inside. PB502031 Plain mounting plate reinforcement kit Kit for reinforcement of fixation between the plain mounting plate and structure. Depth Reference 600 800 NSY5GSPK6 NSY5GSPK8 Supply: • 2 90 mm universal cross rails. • 2 brackets for central fixation. • 2 heavy cross rails & fixing elements. PB502030 19" fixed rack reinforcement kit Kit for reinforcement of fixation between 19" fixed rack and structure. The purpose of this kit is to reinforce the 19" fixed rack. Depth Reference 600 NSY5GRCK42 Supply: • 2 90 mm universal cross rails. • 4 brackets for upright support. • 1 set of standard 42 units 19" fixed rack. • Fixing elements. SFM084.indd version: 2.0 7