2016 - Support Home
Transcripción
2016 - Support Home
Protect Your Company Build a Strong Team STRUCTURAL BUILDING COMPONENTS ASSOCIATION Measure Progress Educate Your Staff Two SCORE Designations Are Available to Participants: SCORE Member The plant is a member in good standing with a year to work toward SCORE certification and has purchased the following either individually or as a package: ■ Access to TTT for all truss designers. ■ Access to SBCA’s online QC program. ■ Jobsite Packages, which are sent with every truss delivery. Simplified Certifications ■ Centered on programs that matter most to CMs’ customers. SCORE Certified The plant is a member in good standing and is compliant with all items below: ■ Streamlined certification requirements and quality focused. ■ ■ ■Simplified designations available: SCORE Certified or a SCORE Member working toward certification. ■ ■ ■ Members who are working toward SCORE certification start reaping the benefit of their efforts immediately. ■ ■ New Simplified Requirements ■ Continuing Education: Plant fulfills ongoing TTT requirements. J obsite Packages: Plant purchases and sends with every truss delivery. Plant Tour: Plant hosts one plant tour or similar event per year. C Certification: Plant is SBCA QC certified and continues to Q submit quarterly data files for SBCA review. afety Certification: Plant meets safety program requirements, S either with SBCA Operation Safety or a program reviewed and approved by SBCA staff. TT Certification: Average TTT level for CM designers at a location T must be 1.5 or higher. Quality-Focused ■ Customer-Centered ■ Best Practices 2016 PRODUCTS&PROGRAMS Order online at sbcindustry.com/pubs 2016 Instructions: (Photocopy this page to use with future orders) For each product you want to order: SHIPPING & HANDLING (SHIPPING UNITS) CONTINENTAL U.S. ORDERS ONLY 1.Enter the Product Code (A), Quantity (B), Price Per Item (C) and Shipping Units (D). 2.For all products, multiply Quantity (B) by Price Per Item (C) to get the Extended Price (E). 3. Multiply the Quantity (B) by Shipping Units Per Item (D) to get Extended Shipping Units (F). SHIPPING UNITS To calculate totals: 4.Subtotal the Extended Prices (E) and the Extended Shipping Units (F) columns. 5. ONLY FOR ORDERS DELIVERED TO WISCONSIN: Calculate WI Sales Tax by multiplying your Subtotal by the appropriate tax amount–5.5%, 5.6%, etc. 6.To calculate Shipping & Handling, find your Total Extended Shipping Units in the first column of the Shipping & Handling chart. Total Shipping & Handling will be the amount shown in the middle or right column, if you are a member or non-member, respectively. Place this amount in Shipping & Handling. Please note: all shipping charges are subject to adjustment. *If you are located outside the CONTINENTAL U.S., your shipping charge will increase. please contact SBCA Staff for shipping and handling. 7.Calculate the Order Total by adding the Subtotal, WI Sales Tax (if applicable), and Shipping & Handling. 8.Add $3.00 for Residential Deliveries. 9. Make checks payable to: SBca They’re your golden defense. 1-39 40-79 80-129 130-179 180-239 240-289 290-349 350-409 410-469 470-529 530-599 600-659 660+ MEMBER NONMEMBER 18.00 21.00 22.00 26.00 24.00 30.00 26.00 36.00 29.00 40.00 33.00 45.00 39.00 52.00 44.00 60.00 51.00 70.00 57.00 79.00 64.00 90.00 69.00 102.00 CONTACT SBCA FOR DELIVERY TIME OF LESS THAN TWO WEEKS, PLEASE CALL SBCA. ADDITIONAL HANDLING FEES MAY APPLY. PRICES SUBJECT TO CHANGE WITHOUT NOTICE. (A) Product Code (B) Quantity or Lots (C) Price (D) Shipping Units (B) x (C) = (E) Extended Price (B) x (D) = (F) Extended Shipping Units Follow the industry’s best practices. Subtotal: “Being able to doccument that a JOBSITE PACKAGE was duly received by your customer and the truss erector is a risk management tool that can provide significant protection to component manufacturers.” Kent Pagel SBCA Legal Counsel WI Sales Tax: NOTE: BUILDING OFFICIALS, FIRE OFFICIALS, ARCHITECTS & ENGINEERS USE LOWEST PRICING Shipping & Handling (Continental U.S. Only*): Residential Delivery Add $3.00: Shipping Address (No P.O. Boxes) City, State, Zip Is this a residential delivery? Yes No Your Name JOBSITE PACKAGES are available for wood, cold-formed steel, long span trusses, floor trusses and wall panels. To learn more or order, visit sbcindustry.com/jobsite. 6300 Enterprise Lane Madison, WI 53719 608-274-4849 phone 608-274-3329 fax sbcindustry.com Telephone (Area Code) Name that appears on credit card (please print) VISA/MC/AmEx Number Credit Card Billing Address Send me information about new publications & specials. Email Address (for automated shipping notification) F O R M F O R & TOTAL: Company Place your order online at sbcindustry.com/pubs IT'S FAST AND SIMPLE! (or fax to 608-274-3329) O R D E R P R O D U C T S Educate your customers. Protect your company. Boost your commitment to safety. S B C A Purchase Order Number (if required) Signature Verification Code Exp. Date S E R V I C E S Products IN ALPHABETICAL ORDER Additional Loading Tag........................................................................22 ANSI/TPI 1-2014 packaged with Metal Plate Connected Wood Truss Handbook .......................................................................................... 6 (In-Plant) Basic Training................................................................. 16-17 BCSI Book & All Summary Sheets.................................................... 8-10 BCSI Book for Cold-Formed Steel.........................................................20 Bearing Location Tag...........................................................................22 Bearing Location Tag – CFS.................................................................22 Builder Advisory on Mold (TTB)...........................................................13 Building with Floor Trusses CD.............................................................18 CFSC Guide for Handling & Installing Cold-Formed Steel Wall Panels…21 CalcuSlope Scale.................................................................................19 Canadian BCSI Book........................................................................…20 Checklist for Handling & Installing Trusses (TTB)..................................13 Checklist for Handling & Installing Trusses (SCC) – CFS........................21 Cold-Formed Steel Jobsite Cover Sheet…………………………………...21 Commentary for Permanent Bracing of MPCWT Booklet........................7 Component Industry Information Binder..................... See Online Catalog Component Technology Workshops (CTWs on CD)...............................18 Concentrated Load Tag.......................................................................22 Considerations for Contractors Building with Wall Panels (TTB).............13 Construction Loading – BCSI-B4............................................................9 Construction Loading for CFS – CFSBCSI-B4........................................20 Crane Use & Proper Truss Handling (TTB)...........................................12 Design Tools CD..................................................................................19 Do Not Cut, Drill or Alter Tag...............................................................22 Do Not Use Damaged Components Tag – CFS.....................................22 Drywall Cracking & Crowning (DCC) Issues (CTB)................................12 Facts on the Fire Performance of Wood Trusses Brochure.......................6 Facts Regarding Mold on Wood Structural Building Components (TTB).....13 Fall Protection & Trusses – BCSI-B11....................................................10 Fall Protection & Trusses for CFS – CFSBCSI-B11..................................20 Fall Protection Tag...............................................................................22 Floor Truss Fact Sheet (TTB)................................................................12 Floor Truss JOBSITE PACKAGE............................................................11 Forklift Certification Program and Materials.................................... 15-16 Framing the American Dream® Brochure...............................................6 Framing the American Dream® with Roof & Floor Trusses Brochure........6 Framing the American Dream® DVD...................................................18 Framing the American Dream® – Wall Panel Demonstration CD...........19 Future of Framing Brochure...................................................................6 Long Span Truss Installation (TTB).......................................................13 Metal Plate Connected Wood Truss Handbook................................... 6-7 Multi-Ply Girders – BCSI-B9.................................................................10 Multi-Ply Truss Tag...............................................................................22 Operation Safety Program and Materials........................................ 14-16 (CFSC) QC Wall Panel Program...........................................................21 (SBCA) QC In-Plant Wood Truss Program.............................................19 (SBCA) QC Wall Panel Program...........................................................19 (Online) Risk and Liability Management Program (ORisk) - See Online Catalog Gable End Frame Permanent Bracing (TTB).........................................12 Handling, Installing, Restraining & Bracing of Engineered Wood Products.... 6 Handling, Installing, Restraining & Bracing of Trusses – BCSI-B1.............8 Handling, Installing, Restraining & Bracing of Trusses for CFS – CFSBCSI-B1....20 Handling, Installing & Temporary Bracing of Wall Panels........................7 Housekeeping Program for Combustible Dust.......................................16 How to Read a Truss Design Drawing (TTB).........................................12 How to Read a Truss Placement Diagram (TTB)...................................13 Information for Framers Flyer…………………..…………................ …..10 Installation Restraint & Bracing Tag – CFS............................................22 Jobsite Cover Sheet English/Spanish…………………..………….. …..10 Jobsite Bags………………................................…..…………………..10 JOBSITE PACKAGE for CFS.................................................................21 JOBSITE PACKAGE for Floor Trusses ...................................................11 JOBSITE PACKAGE for Long Span Trusses...........................................11 JOBSITE PACKAGE for Trusses ...........................................................11 JOBSITE PACKAGE for Wall Panels......................................................11 Jobsite Warning Tag..........................................................................22 Jobsite Warning Tag – CFS................................................................22 Keys to Quality Wood Truss Production CD...........................................18 Partition Separation Prevention & Solutions (TTB)................................13 Permanent Lateral Bracing Tag............................................................22 Permanent Lateral Restraint Tag – CFS................................................22 Permanent Restraint/Bracing of Chords & Web Members – BCSI-B3........9 Permanent Restraint/Bracing of Chords & Web Members for CFS – CFSBCSI-B3....20 Post Frame Truss Installation & Temporary Restraint/Bracing – BCSI-B10 .. 10 Professional’s Guide to the Structural Component Industry Binder...........7 SBCA 2015 Financial Performance Survey of Fiscal Year 2014…..... ….19 SBCA 2014 Wage & Benefit Survey of Calendar Year 2013……….... …19 Safety (Operation Safety Program and Materials)........................... 14-16 Safety Zone Materials..........................................................................17 Standard Responsibilities in the Design Process Involving MPCWT (TTB)..12 Strongback Bridging Tag......................................................................22 Take Five Brochure (TTB)....................................................................13 Technical Assessment Test Online (TATO)................... See Online Catalog Technical Assessment Test Online (TATO) – CFS......... See Online Catalog Temporary & Permanent Restraint/Bracing for Parallel Chord Trusses – BCSI-B7... 9 Temporary Bracing Tag........................................................................22 This Side Up Tag.................................................................................22 Toe-Nailed Connections to Attach Trusses at Bearing Locations – BCSI-B8.10 TRUCK Program and Materials............................................................17 Truss Basics Training and Materials............................ See Online Catalog Truss Configurations (TTB)..................................................................12 Truss Configurations Poster..................................................................12 Truss Damage, Jobsite Modifications & Installation Errors – BCSI-B5...... 9 Truss Damage, Jobsite Modifications & Installation Errors for CFS – CFSBCSI-B5...20 Truss Installation & Temporary Restraint/Bracing – BCSI-B2....................8 Truss Installation & Temporary Restraint/Bracing for CFS – CFSBCSI-B2....20 Truss Manufacturing Orientation (TMO)..................... See Online Catalog Truss Technician Training (TTT), Materials and Certification Exams - See Online Catalog TTB Binder.........................................................................................13 Wall Panel Jobsite Cover Sheet………….......................................... ….10 Wall Panel Jobsite Package.............................................................11 Wall Panel and Hoisting Strap Inspection and Use Requirements (CTB)... 12 Web Reinforcement Tag.......................................................................22 Wood Truss Construction and Fire Performance CD .............................18 Work Force Development Binder………………………………………..…..7 Work Force Development Brochures………………………………….…….7 TABLE OF CONTENTS3-5 DOCUMENTS 6-7 BCSI & JOBSITE PACKAGES 8-11 TRUSS TECHNOLOGY IN BUILDING 12-13 TRAINING & SAFETY PROGRAMS 14-17 EDUCATIONAL CDs 18-19 STEEL PRODUCTS20-22 TRUSS TAGS 22 3 Products by category BRACING – PERMANENT B3 and B7 Summary Sheets................................................................ 9 Building Component Safety Information (BCSI) Book............................ 8 Cold-Formed Steel BCSI Book............................................................ 20 CFSBCSI-B3 Summary Sheet............................................................. 20 Commentary for Permanent Bracing of MPCWT Booklet...................... 7 Gable End Frame Permanent Bracing (TTB)....................................... 12 Overview of Building Component Safety Information (CTW on CD)..... 18 Permanent Lateral Bracing Tag.......................................................... 22 Permanent Lateral Restraint Tag – CFS............................................. 22 Strongback Bridging Tag.................................................................... 22 Web Reinforcement Tag..................................................................... 22 BRACING – TEMPORARY B1, B2, B7 and B10 Summary Sheets............................................. 8-10 Building Component Safety Information (BCSI) Book............................ 8 Cold-Formed Steel BCSI Book............................................................ 20 CFSBCSI-B1 and B2 Summary Sheets................................................ 20 Checklist for Handling & Installing Trusses (TTB)................................ 13 Overview of Building Component Safety Information (CTW on CD)..... 18 Storage, Handling, Installation, Restraining and Bracing (CTW on CD)....18 Temporary Bracing Tag...................................................................... 22 BUILDING DESIGN Building Component Safety Information (BCSI) Book............................ 8 B8 Summary Sheet........................................................................... 10 CFSDRESP Standard Responsibilities................................................. 21 Cold-Formed Steel BCSI Book............................................................ 20 Design Tools CD............................................................................... 19 Florida Board of Professional Engineers Rule 61G15-31.003 (CTW on CD)...18 Gable End Frame Permanent Bracing (TTB)....................................... 13 Overview of Building Component Safety Information (CTW on CD)..... 18 Partition Separation Prevention & Solutions (TTB).............................. 13 Standard Responsibilities in the Design Process Involving MPCWT (TTB)...12 Wood Trusses and the IBC (CTW on CD)............................................ 18 Wood Trusses and the IRC (CTW on CD)........................................... 18 EDUCATION & training Building Component Safety Information (BCSI) Book............................ 8 CFSC QC Wall Panel......................................................................... 21 CFSDRESP Standard Responsibilities................................................. 21 Cold-Formed Steel BCSI Book............................................................ 20 Component Technology Workshop (CTWs on CD).............................. 18 Design Tools CD ..............................................................................19 Forklift Certification Program and Materials.................................. 15-16 Housekeeping Program for Combustible Dust..................................... 16 In-Plant Basic Training.................................................................. 16-17 Online Risk & Liability Management (ORisk) Program....See Online Catalog Operation Safety Program and Materials....................................... 14-15 Overview of Building Component Safety Information (CTW on CD)..... 18 SBCA 2015 Financial Performance Survey of Fiscal Year 2014……….19 SBCA 2014 Wage & Benefit Survey of Calendar Year 2013................. 19 SBCA QC In-Plant Wood Truss Program............................................. 19 Safety Zone Materials....................................................................... 17 Technical Assessment Test Online (TATO)................. See Online Catalog Technical Assessment Test Online (TATO) – CFS....... See Online Catalog TRUCK Program and Materials.......................................................... 17 Truss Basics Training and Materials........................... See Online Catalog Truss Manufacturing Orientation (TMO).................... See Online Catalog Truss Technician Training (TTT), Materials & Certification Exams...See Online Catalog Truss Technology in Building (TTB) Series...................................... 12-13 Truss Technology Workshops (CTWs on CD)........................................18 WTCA QC Wall Panel Program.......................................................... 19 Work Force Development Binder.......................................................... 7 Work Force Development Brochures..................................................... 7 FIRE Facts on the Fire Performance of Wood Trusses Brochure............................6 Wood Truss Construction and Fire Performance CD............................ 18 FLOOR TRUSSES B7 Summary Sheet............................................................................. 9 JOBSITE PACKAGE for Floor Trusses...................................................11 Building with Floor Trusses CD........................................................... 18 Floor Truss Fact Sheet (TTB).............................................................. 12 HANDLING & INSTALLATION 3-5 TABLE OF CONTENTS 6-7 DOCUMENTS 8-10 BCSI & JOBSITE PACKAGES 12-13 TRUSS TECHNOLOGY IN BUILDING 14-17 TRAINING & SAFETY PROGRAMS 18-19 EDUCATIONAL CDs 20-22 STEEL PRODUCTS 22 4 TRUSS TAGS Additional Loading Tag...................................................................... 22 B1-B11 Summary Sheets................................................................ 8-10 CFSBCSI-B1, B2, B3, B4, B5 and B11 Summary Sheets..................... 20 Cold-Formed Steel BCSI Book........................................................... 20 Bearing Location Tag......................................................................... 22 Bearing Location Tag – CFS.............................................................. 22 Checklist for Handling & Installing Trusses (TTB)................................ 12 Checklist for Handling & Installing Trusses (SCC) – CFS..................... 21 Cold-Formed Steel Jobsite Cover Sheet.............................................. 21 Concentrated Load Tag..................................................................... 22 Crane Use & Proper Truss Handling (TTB)......................................... 12 Design Tools CD ...............................................................................19 Do Not Cut, Drill or Alter Tag............................................................. 22 Products by category Do Not Use Damaged Components Tag – CFS.................................. 22 Four Steps to Safe Truss Installations (CTW on CD)............................ 18 Guide for Handling, Installing, Restraining & Bracing of Engineered Wood Products....6 JOBSITE PACKAGE for CFS.............................................................. 21 JOBSITE PACKAGE for Floor Trusses ................................................. 11 JOBSITE PACKAGE for Trusses ......................................................... 11 JOBSITE PACKAGE for Wall Panels.................................................... 11 Jobsite Cover Sheet English/Spanish.................................................. 10 Jobsite Warning Tag.......................................................................... 22 Jobsite Warning Tag – CFS................................................................ 22 Long Span JOBSITE PACKAGE.......................................................... 11 Long Span Truss Installation (TTB)..................................................... 13 Metal Plate Connected Wood Truss Handbook (Print and CD)............ 6-7 Multi-Ply Truss Tag............................................................................. 22 Overview of Building Component Safety Information (CTW on CD)..... 18 Storage, Handling, Installation, Restraining and Bracing (CTW on CD)....18 This Side Up Tag............................................................................... 22 Wall Panel Jobsite Cover Sheet........................................................... 10 joBSITE SAFETY B1, B2, B4 and B11 Summary Sheets............................................. 8-10 CFSBCSI-B1, B2, B4 and B11 Summary Sheets.................................. 20 Checklist for Handling & Installing Trusses (TTB)................................ 12 Crane Use & Proper Truss Handling (TTB)......................................... 12 Design Tools CD ..............................................................................19 Do Not Cut, Drill or Alter Tag............................................................. 22 Do Not Use Damaged Components Tag – CFS.................................. 22 Four Steps to Safe Truss Installations (CTW on CD)............................ 18 JOBSITE PACKAGE for CFS.............................................................. 21 JOBSITE PACKAGE for Floor Trusses .......................................................11 JOBSITE PACKAGE for Trusses (English/Spanish and English/French)....11 JOBSITE PACKAGE for Wall Panels.................................................... 11 Jobsite Warning Tag.......................................................................... 22 Jobsite Warning Tag – CFS................................................................ 22 Long Span JOBSITE PACKAGE.......................................................... 11 Long Span Truss Installation (TTB)..................................................... 13 Overview of Building Component Safety Information (CTW on CD)..... 18 Safety Zone Materials........................................................................ 17 Storage, Handling, Installation, Restraining and Bracing (CTW on CD)....18 TRUCK Program and Materials.......................................................... 17 Framing the American Dream® (CTW on CD)..................................... 18 Framing the American Dream® – Wall Panel Demonstration CD.......... 19 Future of Framing Brochure................................................................. 6 Professional’s Guide to the Structural Component Industry Binder......... 7 Truss Configurations (TTB)................................................................ 12 Truss Configurations Poster................................................................ 12 QUALITY CONTROL CFSC QC Wall Panel Program........................................................... 21 In-Plant WTCA QC Program.............................................................. 19 Keys to Quality Wood Truss Production CD......................................... 18 WTCA QC Wall Panel Program.......................................................... 19 REFERENCE MATERIALS Building Component Safety Information (BCSI) Book............................ 8 ANSI/TPI 1-2014 with Metal Plate Connected Wood Truss Handbook.... 6-7 CFSDRESP Standard Responsibilities................................................. 21 Cold-Formed Steel BCSI Book........................................................... 20 Commentary for Permanent Bracing of MPCWT Book.......................... 7 How to Read a Truss Design Drawing (TTB)....................................... 12 How to Read a Truss Placement Diagram (TTB)................................. 13 Metal Plate Connected Wood Truss Handbook (Print and CD)............... 6 Standard Responsibilities in the Design Process Involving MPCWT (TTB)..12 Truss Configurations (TTB)................................................................ 12 Truss Configurations Poster................................................................ 12 steel products & Services Bearing Location Tag – CFS............................................................... 22 CFSBCSI-B1, B2, B3, B4, B5 and B11 Summary Sheets..................... 20 CFSC QC Wall Panel Program........................................................... 21 Checklist for Handling & Installing Trusses (SCC) – CFS..................... 21 Cold-Formed Steel BCSI Book........................................................... 20 Do Not Use Damaged Components Tag – CFS................................... 22 Installation, Restraint & Bracing Tag – CFS........................................ 22 JOBSITE PACKAGE for CFS.............................................................. 21 Jobsite Warning Tag – CFS................................................................ 22 Permanent Lateral Restraint Tag – CFS............................................. 22 Technical Assessment Test Online (TATO) – CFS....... See Online Catalog 11x17 Guide for Handling & Installing CFS Wall Panels..................... 21 CFSDRESP Standard Responsibilities................................................. 21 LUMBER & MOLD Builder Advisory on Mold (TTB)......................................................... 13 Drywall Cracking & Crowning (DCC) Issues (CTB) ............................. 12 Facts Regarding Mold on Wood Structural Components (TTB)............ 13 Minimizing Mold on Structural Building Components (CTW on CD) .....18 Mold and Structural Wood Components (CTW on CD)........................18 MARKETPLACE Design Tools CD ...............................................................................19 Framing the American Dream® Brochure............................................. 6 Framing the American Dream® with Roof & Floor Trusses Brochure...... 6 Framing the American Dream® CD.................................................... 18 waLL PANELS CFSC QC Wall Panel Program........................................................... 21 CFSC Guide for Handling & Installing Cold-Formed Steel Wall Panels..21 Considerations for Contractors Building with Wall Panels (TTB).......... 13 Framing the American Dream® Brochure............................................. 6 Framing the American Dream® – Wall Panel Demonstration CD..........19 Guide for Handling, Installing & Temporary Bracing of Wall Panels....... 7 JOBSITE PACKAGE for Wall Panels.................................................... 11 WTCA QC Wall Panel Program.......................................................... 19 Wall Panel and Hoisting Strap Inspection and Use Requirements.. 12 5 ewphirb11x17p Guide for Handling, Installing, Restraining & Bracing of Engineered Wood Products HB3-set+ansi Metal Plate Connected Wood Truss Handbook Third Edition (PRINT, CD-ROM) and ANSI/TPI 1-2014 ANSI/TPI 1-2007 COMMENTARY & APPENDICES ANSI/TPI 1-2014 ANSI/TPI 1-2014 This guide for builders features proper techniques for unloading, storing, lifting, erecting, installing, restraining and bracing engineered wood products, such as I-joists and structural composite lumber. Numerous graphics and ANSI standardized safety alert symbols accompanied by written instructions provide an easy-to-follow reference. Due to the proprietary nature of most engineered wood products, this sheet is intended to be a supplement to the more specific product information provided by each manufacturer. member non-member shipping The full-color 11"x17" size is lots of 100 PRICE EACH lot PRICE EACH lot units x qty. perfect for printing engineered 1-4 $59.00 $100.00 wood product placement 5-10 56.00 95.00 40 diagrams on the blank side. 11-20 54.00 92.00 COMMENTARY & APPENDICES TO ANSI/TPI 1-2007 D O C U M E N T S Revision of ANSI/TPI 1-2007 Commentary & Appendices to NATIONAL DESIGN STANDARD American National FOR Standard METAL PLATE CONNECTED NATIONAL DESIGN WOOD TRUSS CONSTRUCTION STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION Truss Plate Institute Connecting the Truss Industry 218 North Lee Street, Ste. 312 Alexandria, VA 22314 (703) 683-1010 www.tpinst.org Truss Plate Institute Connecting the Truss Industry Truss Plate Institute Connecting the Truss Industry 141209 TPI 1 and Commentary Covers.indd 1 218 North Lee Street, Ste. 312 Alexandria, VA 22314 (703) 683-1010 www.tpinst.org 141209 TPI 1 and Commentary Covers.indd 2 21+ 52.00 89.00 12/9/2014 12:00:42 PM Truss Plate Institute Connecting the Truss Industry 12/9/2014 12:00:42 PM WTCA's Metal Plate Connected Wood Truss Handbook (printed and on CD) covers industry standards, building codes, design, manufacturing, testing, quality assurance, connection details, fire resistance assemblies and more. Also included are appendices with span tables, design aids, specifications, a glossary and industry associations. The most comprehensive industry reference of its kind! This package also comes with ANSI/ TPI 1-2014, the “National Design Standard for Metal Plate Connected Wood Truss Construction” and Commentary. This is the building code-referenced standard by which all trusses are designed and manufactured in the U.S. quantity member price each non-member price each shipping units x qty. 1-4 5-19 20+ $105.00 83.00 77.00 $210.00 166.00 154.00 55 FAD-D Framing the American Dream® FADrf-D Framing the American Dream® with Roof and Floor Trusses Two identical 2,600 sq. ft. homes were built at the 1996 NAHB Builders Show – one conventionally framed, the other built with trusses and wall panels. This document details what we learned about craftsmanship in component manufacturing. Customize it with your company’s logo and get maximum exposure. This document focuses exclusively on what we learned about framing with roof and floor trusses. Perfect for educating markets about the benefits of framing with roof and floor trusses. (4 pages) lots of 50 1-4 5-19 20+ member non-member price each lot price each lot $10.00 9.50 9.00 $25.00 23.75 22.50 24 Produced by the Carbeck Structural Components Institute to accompany the Fire Performance of Wood Trusses CD and is great for fire service presentations and others in the construction industry, It summarizes important facts about trusses' performance when subjected to fire. 1-9 10-19 20+ member non-member price each lot price each lot $15.00 14.00 13.00 $37.50 35.00 32.50 shipping units x qty. 24 future-d Future of Framing This marketing brochure is an excellent way to show customers and homeowners the many benefits of truss construction and that structural building components are the future of framing. (4 pages) lots of 50 1-9 10-19 20+ 6 2016 member non-member price each lot price each lot $15.00 14.00 13.00 $37.50 35.00 32.50 WTCA's Metal Plate Connected Wood Truss Handbook is the most comprehensive industry reference of its kind! Can be 3-hole punched. quantity member price each non-member price each shipping units x qty. 1-4 5-19 20+ $49.95 35.95 30.00 $124.90 89.90 75.00 45 shipping units x qty. FIREBRO-d Facts on the Fire Performance of Wood Trusses (4 pages) lots of 50 HB3-D Metal Plate Connected Wood Truss Handbook Third Edition (PRINT version) shipping units x qty. HB3-eD Metal Plate Connected Wood Truss Handbook Third Edition (cd-rom version) The electronic version of the Handbook allows you to search, print and email pages as Acrobat® PDF files. quantity member price each non-member price each shipping units x qty. 1-4 5-19 20+ $49.95 35.95 30.00 $124.90 89.90 75.00 7 HB3-set Metal Plate Connected Wood Truss Handbook Third Edition (print & cd-rom) WTCA's Metal Plate Connected Wood Truss Handbook (printed and CD version). Purchase the set and save! quantity 1-4 5-19 20+ member price each $74.95 60.00 52.50 non-member price each $187.40 150.00 131.25 shipping units x qty. 48 24 ORDER ONLINE AT sbcindustry.com/pubs hb3-D+ANSI Metal Plate Connected Wood Truss Handbook Third Edition (PRINT) & ANSI/TPI 1-2014 wallpanel11x17-p wallpanelfold-p Guide for Handling, Installing & Temporary Bracing of Wall Panels This guide for builders features proper techniques for unloading, storing, lifting, erecting, installing, and temporarily bracing wall panels. Numerous graphics and ANSIstandardized safety alert symbols accompanied by written instructions provide an easy-to-follow reference. This full-color 11"x17" size is perfect for printing wall panel placement diagrams on the blank side. WTCA's Metal Plate Connected Wood Truss Handbook packaged with ANSI/TPI 1-2014 and Commentary. ANSI/TPI 1-2014 ANSI/TPI 1-2014 COMMENTARY & APPENDICES TO ANSI/TPI 1-2007 ANSI/TPI 1-2007 COMMENTARY & APPENDICES Revision of ANSI/TPI 1-2007 Commentary & Appendices to NATIONAL DESIGN STANDARD AmericanFOR National Standard METAL PLATE CONNECTED NATIONAL DESIGN WOOD TRUSS CONSTRUCTION STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION quantity member price each non-member price each shipping units x qty. 1-4 5-19 20+ $80.00 65.00 58.00 $200.00 162.50 145.00 60 wallpanel11x17-p lots of 100 Truss Plate Institute Connecting the Truss Industry member non-member shipping PRICE EA. lot PRICE EA. lot units x qty. lots of 1000 12/9/2014 12:00:42 PM 1-4 5-10 11-20 21+ Truss Plate Institute Connecting the Truss Industry 12/9/2014 12:00:42 PM hb3-ed+ansi Metal Plate Connected Wood Truss Handbook Third Edition (CD-ROM) & ANSI/TPI 1-2014 ANSI/TPI 1-2014 ANSI/TPI 1-2014 COMMENTARY & APPENDICES TO ANSI/TPI 1-2007 ANSI/TPI 1-2007 COMMENTARY & APPENDICES Commentary & Appendices to NATIONAL DESIGN STANDARD American FOR National Standard METAL PLATE CONNECTED NATIONAL DESIGN WOOD TRUSS CONSTRUCTION STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION quantity member price each non-member price each shipping units x qty. 1-4 5-19 20+ $105.00 83.00 77.00 $210.00 166.00 154.00 20 $100.00 95.00 92.00 89.00 40 1 2 wallpanelfold-p member non-member shipping PRICE EA. LOT PRICE EA. LOT units x qty. $560.00 540.00 $950.00 920.00 300 WFDbinder Work Force Development Binder WTCA's Metal Plate Connected Wood Truss Handbook on CD packaged with ANSI/TPI 1-2014 and Commentary. Revision of ANSI/TPI 1-2007 $59.00 56.00 54.00 52.00 D D O O C C U U M M EE N N T T S S YOUR TOOLKIT FOR BUILDING RELATIONSHIPS & GROWING YOUR WORKFORCE Truss Plate Institute Connecting the Truss Industry 12/9/2014 12:00:42 PM 2 SBCA – Structural Building Components Association 6300 Enterprise Lane | Madison, WI 53719 | 608-274-4849 | sbcindustry.com Truss Plate Institute Connecting the Truss Industry 12/9/2014 12:00:42 PM The SBCA Work Force Development Industry Promotion Binder is an excellent tool to use in building relationships with tech schools, community colleges and even high schools. The binder includes a ten-minute introduction to the structural building components industry, with an emphasis on careers. Perfect for classroom presentations and job fairs! There are also full-color brochures about careers in the industry, as well as various SBCA publications to give interested candidates a better understanding of the many job opportunities available. PBrace-D Commentary for Permanent Bracing of Metal Plate Connected Wood Trusses Provides guidelines for Building Designers to use in designing and specifying permanent bracing for metal plate connected wood truss systems. Illustrations clarify key points. (26 pages) QUANTITY 1-9 10-19 20+ member non-member price each lot price each lot •Accountants •ComponentBuilders •Computer-savvyIndividuals •Designers •Drafters •Engineers •HumanResource& PersonnelExperts •ITSpecialists •JobSchedulers •Marketing&Sales Representatives •PlantManagers •ProductionForemen •PurchasingAgents •SoftwareProgrammers •Transportation Planners •TruckDrivers •YardForemen $17.50 16.25 15.00 TheWFDpathisgood forfinding: •Accountants •ComponentBuilders •Computer-savvyIndividuals •Designers •Drafters •Engineers SBCA’s WorkForce Development (WFD) •HumanResource& website is a “one-stop” resource for PersonnelExperts members, educational institutions and •ITSpecialists potential employees, which will help •JobSchedulers build the talents needed to grow the industry•Marketing&Sales and provide career opportunities Representatives for workers across the country. This site •PlantManagers also provides exceptional online train•ProductionForemen ing resources to help potential, new and existing•PurchasingAgents employees increase their knowledge of•SoftwareProgrammers the industry and its technology in order•Transportation to be more valuable assets and reach their individual potential. Planners •TruckDrivers •YardForemen shipping units x qty. TheSBCIndustryNeeds: $7.00 6.50 6.00 YOUR PATH TO A GREAT NEW CAREER 4 To begin your search for dynamic candidates, go to SBCA’s WorkForce Development website at wfd.sbcindustry.com. wfd.sbcindustry.com There you can post current job openings, review resumés posted by individuals seeking job opportunities and contact those who have the potential to be a good fit for your company. You can also use this website to interface with schools, promote your company to potential employees and utilize SBCA’s evaluation and training programs. To find out more about careers in the structural building components industry, go to SBCA’s WorkForce Development website at wfd.sbcindustry.com. There you can view current job openings at companies across the country, post your resumé, apply for jobs and gain access to additional industry-specific training and education opportunities. You can also use this website to find a component manufacturer near you who may be offering internships or part-time employment. 2014 CM WFD Brochure STEPS.indd 1 Structural Building Components Association (SBCA) 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • 608-274-3329 fax [email protected] • sbcindustry.com Proguide-D Professional's Guide to the Structural Components Industry SBCA’s new WorkForce Development (WFD) website is a “one-stop” resource for members, educational institutions and potential employees, which will help build the talents needed to grow the industry and provide career opportunities TheSBCIndustry Needs: for workers across the country. This site also •Accountants provides exceptional online training resources to help potential, new and •ComponentBuilders existing employees increase their knowl•Computer-savvyIndividuals edge of the industry and its technology •Designers in order to be more valuable assets and •Drafters reach their individual potential. •Engineers •HumanResource& PersonnelExperts •ITSpecialists •JobSchedulers wfd.sbcindustry.com •Marketing&Sales Representatives •PlantManagers •ProductionForemen •PurchasingAgents •SoftwareProgrammers •Transportation Planners •TruckDrivers •YardForemen YOUR PATH TO A GREAT NEW CAREER To find out more about careers in the structural building components industry, go to SBCA’s WorkForce Development Structural Building Components Association website (SBCA) at wfd.sbcindustry.com. 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • 608-274-3329 fax There you can view current job openings, [email protected] • sbcindustry.com post your resumé, apply for jobs and gain access to additional industry-specific training and education opportunities. Build Your Dream Job You can also use this website to find a component manufacturer near you who may be offering The Structural Building internships or part-time employment. Components Industry May Be Right for You 2014 WFD Brochure.indd 1 2014 APPL WFD Brochure STEPS.indd 1 This binder designed for architects, engineers, specifiers and building officials includes selected information and SBCA publications: the BCSI Book, Commentary for Permanent Bracing of Metal Plate Connected Wood Trusses and the Metal Plate Connected Wood Truss Handbook. Binder cover can be customized with your company or chapter logo. Minimum customized order of 25. TheSBCIndustryNeeds: I M P O R TA N T S A F E T Y I N F O R M AT I O N Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses NOTICE WARNING CAUTION DANGER JOINTLY PRODUCED BY •Accountants •ComponentBuilders •Computer-savvyIndividuals •Designers •Drafters •Engineers •HumanResource& PersonnelExperts •ITSpecialists •JobSchedulers •Marketing&Sales Representatives •PlantManagers •ProductionForemen •PurchasingAgents •SoftwareProgrammers •Transportation Planners •TruckDrivers •YardForemen quantity 1 SBCA’s WorkForce Development (WFD) website is a “one-stop” resource for members, educational institutions and potential employees, which will help build the talents needed to grow the industry and provide career opportunities for workers across the country. This site also provides exceptional online training resources to help potential, new and existing employees increase their knowledge of the industry and its technology in order to be more valuable assets and reach their individual potential. non-member price each $100.00 $250.00 shipping units x qty. There you can view current job openings at companies across the country, post your resumé, apply for jobs and gain access to additional industry-specific training and education opportunities. You can also use this website to find a component manufacturer near you who may be offering internships or part-time employment. 2014 APPL WFD Brochure STEPS.indd 1 Structural Building Components Association (SBCA) 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • 608-274-3329 fax [email protected] • sbcindustry.com 90 Build Your Dream Job The Structural Building Components Industry May Be Right for You WHAT ARE STRUCTURAL BUILDING COMPONENTS? Date: Time: wfd.sbcindustry.com Location: SBCA-WFD: An Introduction to the Structural Building Component Industry Find The Perfect Employee How to Effectively Promote the Structural Building Components Industry Discovering a Whole New Career SBCA – Structural Building Components Association 6300 Enterprise Lane | Madison, WI 53719 | 608-274-4849 | sbcindustry.com 2014 WFD Poster.indd 1 10/14/2014 10:04:43 AM Power Point Presentation & Support Materials Copyright © 2014 SBCA Workforce Development All rights reserved. 10/14/2014 11:56:38 AM Structural Building Components Association (SBCA) 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • 608-274-3329 fax [email protected] • sbcindustry.com 10/14/2014 9:10:33 AM 9/19/2014 11:59:48 AM quantity 1 member PRICE EACH non-member price each $35.00 N/A SBCA-WFD: An Introduction to the Structural Building Component Industry Power Point Presentation & Support Materials shipping units x qty. 90 Copyright © 2014 SBCA Workforce Development All rights reserved. WFDBROCHURE Your Path To a New Career YOUR PATH TO A GREAT NEW CAREER wfd.sbcindustry.com To find out more about careers in the structural building components industry, go to SBCA’s WorkForce Development website at wfd.sbcindustry.com. member PRICE EACH YOUR PATH TO A VIBRANT WORKFORCE Build Your Dream Job The Structural Building Components Industry May Be Right for You 2014 WFD CD Label.indd 1 10/14/2014 10:01:11 AM The WFD brochure “Your Path to a Great New Career” is one of three brochures in the WFD Binder providing an overview of the career paths in the structural building components industry. This can be used at career fairs and presentations in educational institutions introducing the industry to potential candidates for full-time and part-time employment. LOTS OF 25 1 member PRICE EACH non-member price each $16.00 NA shipping units x qty. 10 9/19/2014 11:59:48 AM Structural Building Components Association 2013 EDITION 2016 ORDER ONLINE AT sbcindustry.com/pubs 7 7 bcsied2-d Building Component Safety Information Book – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses The latest edition of BCSI (2013 edition updated March 2015) includes updated references to the 2014 edition of TPI 1, the 2015 International Building Code (IBC) and 2015 International Residential Code (IRC), and the most current editions of the OSHA Fall Protection standards. BCSI consists of ten chapters that contain the most current information regarding the handling, installing, restraining and bracing of metal plate connected wood trusses. I M P O R TA N T S A F E T Y I N F O R M AT I O N Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses & J O B S I T E P A C K A G E S NOTICE WARNING CAUTION DANGER JOINTLY PRODUCED BY Structural Building Components Association 2013 EDITION QUANTITY member PRICE EACH non-member PRICE EACH UNITS PER BOOK 1-9 10-39 40-239 240+ $13.00 12.50 12.00 11.50 $26.00 25.00 24.00 23.00 10 BCSI Canada is the truss industry's guide for jobsite safety and truss performance. This 8.5" x 11" edition (3-hole punched and spiral bound) includes information regarding the handling, installation, restraining and bracing of metal plate connected wood trusses. With revisions to BCSI from TPIC, BCSI Canada includes: Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses NOTICE WARNING • Canadian references CAUTION DANGER JOINTLY PRODUCED BY • Installation tolerances changed to align with local practices Structural Building Components Association 2014 EDITION 2014 BCSI Canada.indd 1 7/22/2014 8:04:54 AM BCSI-B1 SUMMARY SHEET - GUIDE FOR HANDLING, INSTALLING, RESTRAINING AND BRACING OF TRUSSES B1 Hoisting and Placement of Truss Bundles Recomendaciones Para Levantar Paquetes de Trusses Puede usar un solo lugar de levantar para paquetes de trusses de la cuerda superior hasta Handling — Manejo For trusses stored for more than one week, cover bundles to protect from the environment. • Design related tables consistent with Canadian design standard • Floor truss lateral bracing matches current Canadian practice QUANTITY member PRICE EACH non-member PRICE EACH SHIPPING UNITS X QTY. EACH $14.00 $24.00 100 b 1warnROLL2-P: 11"x17" on a 2" core roll. English/ Spanish. Do you print your plans on a plotter? If so, now you can print them on paper that has BCSI-B1 pre-printed on the reverse side! Roll size measures 24"x150'. Poster image measures 11"x17" and repeats twice every 25" for a total of 144 impressions per toll. Now you can have your plotter paper and warning posters combined! ging and hoisting equipment. dO nOt store unbraced bundles upright. nO almacene verticalmente los trusses sueltos. Construction Loading Carga De Construcción 6' (1.8 m) o.c. max. Soporte cerca al pico los trusses de 20 pies o menos. dO nOt exceed maximum stack heights. Refer to BCSI-B4*** for more information. Refer to BCSI-B2*** for more information. Vea el resumen BCSI-B2*** para más información. Locate ground braces for first truss directly in line with all rows of top chord temporary lateral restraint (see table in the next column). dO nOt store on uneven ground. Repita los arrisotres diagonales para cada grupo de 4 trusses. dO nOt stand on truss overhangs until Structural Sheathing has been applied to the truss and overhangs. Lateral Restraints - 2x4x12' or greater lapped over two trusses or CLR splice reinforcement. Bottom chords Coloque las cargas sobre tantos trusses como sea posible. Coloque las cargas sobre las paredes soportantes. Alterations — Alteraciones 2x_ CLR Refer to BCSI-B5.*** B1WARNROLL2-P member non-member PRICE each lot PRICE each lot Minimum 2' 2x_ Scab block centered over splice. Attach to CLR with minimum 8-16d (0.135x3.5") nails each side of splice or as specified by the Building Designer. Note: Some chord and web members not shown for clarity. Trusses that have been overloaded during construction or altered without the Truss Manufacturer’s prior approval may render the Truss Manufacturer’s limited warranty null and void. Trusses que se han sobrecargado durante la construcción o han sido alterados sin la autorización previa del Fabricante de Trusses, pueden hacer nulo y sin efecto la garantía limitada del Fabricante de Trusses. SECTION A-A Contact the Component Manufacturer for more information or consult a Registered design professional for assistance. To view a non-printing PDF of this document, visit sbcindustry.com/b1. *** Truss Member Note: Some chord and web members not shown for clarity. ≤ 45° typ. NOTE: The truss manufacturer and truss designer rely on the presumption that the contractor and crane operator (if applicable) are professionals with the capability to undertake the work they have agreed to do on any given project. If the contractor believes it needs assistance in some aspect of the construction project, it should seek assistance from a competent party. The methods and procedures outlined in this document are intended to ensure that the overall construction techniques employed will put the trusses into place SAFELY. These recommendations for handling, installing, restraining and bracing trusses are based upon the collective experience of leading personnel involved with truss design, manufacture and installation, but must, due to the nature of responsibilities involved, be presented only as a GUIDE for use by a qualified building designer or contractor. It is not intended that these recommendations be interpreted as superior to the building designer’s design specification for handling, installing, restraining and bracing trusses and it does not preclude the use of other equivalent methods for restraining/bracing and providing stability for the walls, columns, floors, roofs and all the interrelated structural building components as determined by the contractor. Thus, SBCA and TPI expressly disclaim any responsibility for damages arising from the use, application, or reliance on the recommendations and information contained herein. 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • sbcindustry.com 10' (3 m) - 15' (4.6 m) max. $153.00 148.00 139.00 B1WARN11x17 150727 7/28/2015 8:11:42 AM b1warn11x17-P: Flat 11”x17” in English/Spanish. Perfect for printing truss placement diagrams on the reverse side. b1warn11x17-P and CANADAb1flat-P member non-member shipping LOTS 0F 250 PRICE EACH LOT PRICE EACH LOT units x qty. 1-4 5-10 11-20 21-49 50+ b1warnfold-P: 11"x17" folded to 8.5"x11" in English/ Spanish. Perfect size for jobsite packages. Part of the pre-assembled English/ Spanish JOBSITE PACKAGE (JOBSITE-D). $80.00 75.00 71.00 68.00 65.00 $136.00 127.00 120.00 115.00 110.00 100 (English/ Spanish) 180 (English/ French) b1warnfold-P and CANADAb1fold-P lots of member non-member shipping 1,000 PRICE EACH LOT PRICE EACH LOT units x qty. 1 2 3-5 6-12 13+ $320.00 300.00 284.00 272.00 260.00 $544.00 508.00 480.00 460.00 440.00 300 (English/Spanish) 600 (English/French) ANADAB1Fold-P: C 11"x17" folded to 8.5"x11" in English/French. Perfect size for jobsite packages. Part of the pre-assembled English/French JOBSITE PACKAGE (CANADAJOBSITE-D). For use in Canada. b1warnC-P: The architectural C-size version of the B1 Summary Sheet. This 18"x24" document is shipped flat so truss placement diagrams can be printed on the reverse side. English/ Spanish. b1warnC-P lots of 250 1-3 4+ member non-member PRICE EACH LOT PRICE EACH LOT $140.00 125.00 $238.00 212.00 shipping units x qty. 180 bcsi-b2 Summary Sheet - Truss Installation & Temporary Restraint/Bracing B2 Truss Installation & Temporary Restraint/Bracing Instalación de Trusses & Restricción/Arriostre Temporal For Trusses Up to 2'-0" On-Center and 80'-0" in Length Para Trusses Hasta 2 Pies En Centro y Hasta 80 Pies De Longitud Warning Spans over 60' require more complex temporary installation restraint/bracing. Consult a registered design professional. ¡aDVErTEnCia! Los tramos más de 60 pies requieren restricción/arriostre de instalación temporal más complejo. Consulte a un profesional registrado de diseño. DangEr Disregarding handling, installing, restraining and bracing safety recommendations is the principal cause of truss erection/installation accidents. El no seguir las recomendaciones de manejo, instalación, restricción y arriostre es la causa principal de los accidentes durante la erección/instalación de trusses. Diagonal Lateral restraint is NOT bracing adequate without diagonal bracing. La Restricción Lateral NO es adecLateral restraint uada sin el Arriostre Diagonal. Always diagonally brace for safety! ¡Siempre arriostre diagonalmente para seguridad! Maximum Spacing For Top Chord Temporary Lateral Restraint (TCTLR) El Espaciamiento Máximo Para La Restricción Lateral Temporal De La Cuerda Superior (TCTLR) TCTLR shown in green max.* spans up 8' o.c. up to max.* 45' 6' o.c. up to max.* 60' 4' o.c. up to max.* 80' Top Chord Temporary Lateral Restraint The graphic at left shows the maximum on-center spacing (see * at left) of TCTLR based on truss span from the table in Step 2 on page 2. • Ground bracing not shown for clarity. • Apply diagonal bracing or structural sheathing immediately. For spans over 60' applying structural sheathing immediately is the preferred method. El dibujo a la izquierda muestra el espaciamiento máximo en el centro (vea * a la izquierda) del TCTLR basado en los tramos de trusses de la tabla en el Paso 2 en la página 2. • No se muestra el arriostre de tierra para claridad. • Aplique inmediatamente el Arriostre Diagonal o el Entablado Estructural (structural sheathing). Para tramos más de 60 pies el método preferido es entablarlos inmediatamente. Check These Items Before Starting Truss Erection/Installation and Correct as Needed Revise Estos Puntos Antes De Empezar La Erección/Instalación y Corríjalos Cuando Es Necesario Building dimensions match the construction documents. Las dimensiones del edificio concuerdan con los documentos de construcción. Bearing supports (e.g., walls, columns, headers, beams, etc.) are accurately and securely installed, plumb and properly braced. Los soportes que sostienen cargas (ej., paredes, columnas, vigas de cabezera, vigas, etcétera) son instalados seguramente y con precisión, y son nivelados y arriostrados apropiadamente. Hangers, tie-downs, restraint and bracing materials are on site and accessible. Los colgadores (hangers), soportes de anclaje (tie-downs) y materiales de restricción y arriostre están accesibles en la obra. Erection/installation crew is aware of installation plan and lateral restraint/diagonal bracing requirements. El personal de erección/instalación es consciente del plan de instalación y los requisitos de restricción/arriostre. 200 TRuSS plATE INSTITuTE 218 N. Lee St., Ste. 312 • Alexandria, VA 22314 703-683-1010 • tpinst.org 2015 B1 Summary Sheet.indd 1 Truss shipping units x qty. Truss bracing not shown for clarity. nO corte, altere o perfore ningún miembro estructural de un truss, a menos que esté específicamente permitido en el dibujo del diseño del truss. A diagonal braces every 10 truss spaces 20' (6.1 m) max. nO se pare en voladizos cerchas hasta Revestimiento estructural ha sido aplicado a la armadura y voladizos. 2 bundles 8" (203 mm) 3-4 tiles high dO nOt cut, alter, or drill any structural member of a truss unless specifically permitted by the truss design drawing. diagonal braces every 10 truss spaces 20' (6.1 m) max. 3) BOTTOM ChORd — CuERdA INfERIOR Brace first truss securely before erection of additional trusses. ≈90° dO nOt walk on unbraced trusses. nO camine en trusses sueltos. height 12" (305 mm) 16" (406 mm) Concrete Block Clay Tile Vea el resumen BCSI-B5.*** Bottom chords 10' (3 m) - 15' (4.6 m) max. Same spacing as bottom chord lateral restraint Maximum Stack height for Material on Trusses Material Gypsum Board Plywood or OSB Asphalt Shingles dO nOt overload small groups or single trusses. nO sobrecargue pequeños grupos o trusses individuales. Position loads over load bearing walls. CLR splice reinforcement Truss Member ≤ 45° typ. A ≤ 2’o.c., typ. Coloque los arriostres de tierra para el primer truss directamente en línea con cada una de las filas de restricción lateral temporal de la cuerda superior (vea la tabla en la próxima columna). nO almacene en tierra desigual. Refer to BCSI*** for more detailed information pertaining to handling and jobsite storage of trusses. Section A-A Place loads over as many trusses as possible. bracing Top Chord Temporary Lateral Restraint (TCTLR) 2x4 min. 12.5' (3.8 m) 14.6' (4.5 m) 16.7' (5.1 m) 18.8' (5.7 m) 20.8' (6.3 m) 22.9' (7.0 m) 25.0' (7.6 m) 29.2' (8.9 m) ≥33.3' (10.1 m) never stack materials near a peak, at mid-span, on cantilevers or overhangs. nUnca apile los materiales cerca de un pica, a centro de la luz, en cantilevers o aleros. LATERAL RESTRAINT & DIAGONAL BRACING ARE VERY IMPORTANT Web members 3/4" (19 mm) 7/8" (22 mm) 1" (25 mm) 1-1/8" (29 mm) 1-1/4" (32 mm) 1-3/8" (35 mm) 1-1/2" (38 mm) 1-3/4" (45 mm) 2" (51 mm) TCTLR ¡LA RESTRICCIÓN LATERAL Y EL ARRIOSTRE DIAGONAL SON MUY IMPORTANTES! Diagonal Trusses up to 30' (9.1 m) Trusses hasta 30 pies d (ft.) 1' (0.3 m) 2' (0.6 m) 3' (0.9 m) 4' (1.2 m) 5' (1.5 m) 6' (1.8 m) 7' (2.1 m) ≥8' (≥2.4 m) nO exceda las alturas máximas de montón. Vea el resumen BCSI-B4*** para más información. A 10” or > Truss attachment required at support(s) 2) WEB MEMBER plANE — plANO dE lOS MIEMBROS SECuNdARIOS (9.1 m) or less, support at quarter points. Soporte de los cuartos de tramo los trusses de 30 pies o menos. d/50 nO proceda con la construcción hasta que todas las restricciones laterales y los arriostres estén colocados en forma apropiada y segura. A ≤ 45° typ. Note: Ground bracing not shown for clarity. Trusses 30' Trusses up to 20' (6.1 m) Trusses hasta 20 pies Out-of-plane Max. Bow Truss length Out-of-plumb 1/4" (6 mm) 1/2" (13 mm) 3/4" (19 mm) 1" (25 mm) 1-1/4" (32 mm) 1-1/2" (38 mm) 1-3/4" (45 mm) 2" (51 mm) dO nOt proceed with construction until all lateral restraint and bracing is securely and properly in place. 4' (1.2 m) o.c. max. Refer to BCSI-B3*** for Gable End Frame restraint/bracing/ reinforcement information. Para información sobre restricción/ arriostre/refuerzo para Armazones Hastiales vea el resumen BCSI-B3*** Repeat diagonal braces for each set of 4 trusses. Temporary Restraint & Bracing Restricción y Arriostre Temporal Vea el folleto BCSI*** para información más detallada sobre el manejo y almacenado de los trusses en área de trabajo. ≤45° Typical $90.00 87.00 82.00 Tolerancias para Fuera-de-Plomada. DE LA GUÍA DE BUENA PRÁCTICA PARA EL MANEjO, INSTALACIÓN, RESTRICCIÓN Y ARRIOSTRE DE LOS TRUSSES ¡ADVERTENCIA! HOjA RESUMEN Vanos más de 60 pies pueden requerir arriostre permanente complejo. Por favor, siempre consulte a un Profesional Registrado de Diseño. 10' o.c. 1-2 3-9 10+ Tolerancias para Fuera-de-Plano. Tolerances for Out-of-Plumb. *Consult a Registered Design Professional for trusses longer than 60' (18.3 m). *Consulte a un Professional Registrado de Diseño para trusses más de 60 pies. TRuSSES up TO ANd OvER 60' (18.3 m) TRuSSES hASTA y SOBRE 60 pIES Installation of Single Trusses by Hand Recommendacciones de Levantamiento de Trusses Individuales Por La Mano Diagonal bracing shown in red (2 rolls) lot Installing — Instalación Tolerances for Out-of-Plane. (PCTs). See top of next column for temporary restraint and bracing of PCTs. Este método de restricción y arriostre es para todo trusses excepto trusses de cuerdas paralelas (PCTs) 3x2 y 4x2. Vea la parte superior de la columna para la restricción y arriostre temporal de PCTs. Vea el BCSI-B2*** para las opciones de TCTLR. Los trusses pueden ser descargados directamente en el suelo en aquel momento de entrega o almacenados temporalmente en contacto con el suelo después de entrega. Si los trusses estarán guardados para más de una semana, ponga bloqueando de altura suficiente detrás de la pila de los trusses a 8 hasta 10 pies en centro (o.c.). Para trusses guardados por más de una semana, cubra los paquetes para protegerlos del ambiente. to each truss with at least 2-10d (0.128x3"), 2-12d (0.128x3.25") or 2-16d (0.131x3.5") nails. Sostenga cada truss en posición con equipo de grúa hasta que la restricción lateral temporal de la cuerda superior esté instalado y el truss está asegurado en los soportes. (6.1 m) or less, support near peak. Trusses may be unloaded directly on the ground at the time of delivery or stored temporarily in contact with the ground after delivery. If trusses are to be stored for more than one week, place blocking of sufficient height beneath the stack of trusses at 8’ (2.4 m) to 10’ (3 m) on-center (o.c.). ≤ 2’o.c., typ. All lateral restraints lapped at least two trusses. La madera 2x4 clasificada por estrés es la madera mínima utilizada para restricción lateral y arriostramiento diagonal. Atarlas a cada braguero con al mínimo 2 clavos 10d (0.128x3”), 12d (0.128x3.25”) o 16d (0.131x3.5”). 1) TOp ChORd — CuERdA SupERIOR TrussSpan Span Top Chord Temporary lateral Restraint (TCTlR) Spacing Truss Top Chord Temporary lateral Restraint (TCTlR) Spacing longitud longitudde deTramo Tramo Espaciamiento Espaciamientodel delArriostre ArriostreTemporal Temporalde dela laCuerda CuerdaSuperior Superior Up to 30' 10' (3 m) o.c. max. (9.1 m) 30' (9.1 m) – 8' (2.4 m) o.c. max. 45' (13.7 m) TRuSSES up TO 60' (18.3 m) TRuSSES hASTA 60 pIES equipment until top chord temporary lateral restraint is installed and the truss is fastened to the bearing points. Trusses 20' ! Apply diagonal brace to vertical webs at end of cantilever and at bearing locations. This restraint and bracing method is for all trusses except 3x2 and 4x2 parallel chord trusses Hold each truss in position with the erection Use equipo apropiado para levantar e improvisar. g Minimum lumber used for lateral restraint and diagonal bracing is 2x4 stress-graded lumber. Attach 45' (13.7 m) – 60' (18.3 m) 60' (18.3 m) – 80' (24.4 m)* Repeat diagonal bracing every 15 truss spaces 30' (9.1 m) max. Diagonal bracing ≤ 45° typ. Vea el resumen BCSI-B7*** para más información. *Top chord temporary lateral restraint spacing shall be 10' (3 m) o.c. max. for 3x2 chords and 15' (4.6 m) o.c. for 4x2 chords. Restraint/Bracing for All Planes of Trusses Restricción/Arriostre Para Todos Planos de Trusses TRuSSES up TO 30' (9.1 m) TRuSSES hASTA 30 pIES Spreader bar for truss Use proper rig El contratista tiene la responsabilidad de recibir, descargar y almacenar adecuadamente los trusses en la obra. Descargue los trusses en la tierra liso para prevenir el daño. n ¡caUteLa! Utilice cuidado especial en días ventosos o cerca de cables eléctricos o de 10' (3 m) or 15' (4.6 m)* Refer to BCSI-B7*** for more information. See BCSI-B2*** for TCTLR options. Avoid lateral bending. Evite la flexión lateral. The contractor is responsible for properly receiving, unloading and storing the trusses at the jobsite. Unload trusses to smooth surface to prevent damage. i ¡advertencia! No sobrecargue la estructura apoyada con el paquete de trusses. Place truss bundles in stable position. Using a single pick-point at the peak can damage the truss. El uso de un solo lugar en el pico para levantar puede hacer daño al truss. caUtiOn Use special care in windy weather or near power lines and airports. Restraint & Bracing for 3x2 and 4x2 Parallel Chord Trusses Restricción y Arriostre Para Trusses de Cuerdas Paralelas 3x2 y 4x2 Refer to BCSI-B2*** for more information. Vea el resùmen BCSI-B2*** para más información. Mechanical Hoisting Recommendations for Single Trusses Recomendaciones Para Levantar Trusses Individuales ¡caUteLa! Utilice cautela al quitar las ataduras o los pedazos de metal de sujetar para evitar daño a los trusses y prevenir la herida personal. Lleve el equipo protectivo personal para ojos, pies, manos y cabeza cuando trabaja con trusses. r n trusses with short member temporary lateral restraint (see below). 4) Install top chord diagonal bracing (see below). 5) Install web member plane diagonal bracing to stabilize the first five trusses (see below). 6) Install bottom chord temporary lateral restraint and diagonal bracing (see below). 7) Repeat process with groups of four trusses until all trusses are set. 1) Instale los arriostres de tierra. 2) Instale el primero truss y ate seguramente al arriostre de tierra. 3) Instale los próximos 4 trusses con restricción lateral temporal de miembro corto (vea abajo). 4) Instale el arriostre diagonal de la cuerda superior (vea abajo). 5) Instale arriostre diagonal para los planos de los miembros secundarios para estabilice los primeros cinco trusses (vea abajo). 6) Instale la restricción lateral temporal y arriostre diagonal para la cuerda inferior (vea abajo). 7) Repita éste procedimiento en grupos de cuatro trusses hasta que todos los trusses estén instalados. Warning Do not over load supporting structure with truss bundle. 45’ y trusses de cuerdas paralelas de 30’ o Puse paquetes de trusses en una menos. posición estable. Use por lo menos dos puntos de levantar con grupos de trusses de cuerda superior inclinada hasta 60’ y trusses de cuerdas paralelas hasta 45’. Use por lo menos dos puntos de levantar con grupos de trusses de cuerda superior inclinada mas de 60’ y trusses de cuerdas paralelas mas de 45’. ¡advertencia! El resultado de un manejo, levantamiento, instalación, restricción y arrisotre incorrecto puede ser la caída de la estructura o aún peor, heridos o muertos. caUtiOn Exercise care when removing banding and handling trusses to avoid damaging trusses and prevent injury. Wear personal protective equipment for the eyes, feet, hands and head when working with trusses. a 1) Install ground bracing. 2) Set first truss and attach securely to ground bracing. 3) Set next 4 never use banding to lift a bundle. nUnca use las ataduras para levantar un paquete. top chord pitch trusses up to 45ꞌ (13.7 m) and parallel chord trusses up to 30ꞌ (9.1 m). Use at least two lift points for bundles of top chord pitch trusses up to 60' (18.3 m) and parallel chord trusses up to 45' (13.7 m). Use at least three lift points for bundles of top chord pitch trusses >60' (18.3m) and parallel chord trusses >45' (13.7 m). Warning The consequences of improper handling, erecting, installing, restraining and bracing can result in a collapse of the structure, or worse, serious personal injury or death. w Steps to Setting Trusses Las Medidas de la Instalación de los Trusses dOn’t overload the crane. nO sobrecargue la grúa. A single lift point may be used for bundles of The BCSI-B1 Summary Sheet is for builders and features proper techniques for unloading, storing, lifting, erecting, installing, restraining and bracing trusses. This document summarizes Section B1 of the BCSI Book and is available in several different formats and languages. B1 Spans over 60’ may require complex permanent bracing. Please always consult a Registered Design Professional. Notas Generales General Notes Trusses are not marked in any way to identify the Los trusses no están marcados de ningún modo que frequency or location of temporary lateral restraint identifique la frecuencia o localización de restricción and diagonal bracing. Follow the recommendations lateral y arriostre diagonal temporales. Use las for handling, installing and temporary restraining recomendaciones de manejo, instalación, restricción and bracing of trusses. Refer to BCSI – Guide to y arriostre temporal de los trusses. Vea el folleto BCSI Good Practice for Handling, Installing, Restraining – Guía de Buena Práctica para el Manejo, Instalación, & Bracing of Metal Plate Connected Wood Restricción y Arriostre de los Trusses de Madera Trusses*** for more detailed information. Conectados con Placas de Metal*** para información más detallada. Truss Design Drawings may specify locations of permanent lateral restraint or reinforcement for Los dibujos de diseño de los trusses pueden especificar individual truss members. Refer to the BCSI-B3*** las localizaciones de restricción lateral permanente o for more information. All other permanent bracing refuerzo en los miembros individuales del truss. Vea design is the responsibility of the building designer. la hoja resumen BCSI-B3*** para más información. El resto de los diseños de arriostres permanentes son la responsabilidad del diseñador del edificio. ANADAB1Flat-P: Flat C 11”x17” in English/French. For use in Canada. CANADAbcsi-d Canadian Building Component Safety Information Book I M P O R TA N T S A F E T Y I N F O R M AT I O N bcsi-b1 Summary Sheet - Guide for Handling, Installing, Restraining & Bracing of Trusses This document summarizes the information provided in Section B1 of the 2013 Edition of Building Component Safety Information BCSI – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. Copyright © 2004-2015 Structural Building Components Association and Truss Plate Institute. All rights reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. This document should appear in more than one color. Printed in the United States of America. B C S I Multi-ply trusses, including girders, are correctly fastened together prior to lifting into place. Los trusses de varias capas, incluyendo travesaños, son fijados juntos correctamente antes de levantarlos en lugar. Any truss damage is reported to truss manufacturer. Refer to BCSI-B5.*** Do not install damaged trusses unless instructed to do so by the building designer, truss designer or truss manufacturer. Algún daño a los trusses ha sido reportado al fabricante de trusses. Vea el resumen BCSI-B5.*** No instale trusses dañados a menos que se dijeren el diseñador del edificio, el diseñador del truss o el fabricante del truss. Trusses are the correct dimension. Los trusses son la dimensión correcta. Tops of bearing supports are flat, level and at the correct elevation. La parte superior de los soportes de cojinete son planas, niveladas y a la elevación correcta. Jobsite is clean and neat, and free of obstructions. La obra está limpia, ordenada y sin obstrucciones. Ground bracing procedure for first truss is based on site and building configuration. El procedimiento de Arriostre de Tierra para el primer truss es basado en el terreno y la configuración del edificio. Interior Exterior If ground level is too far from truss for exterior ground bracing, use interior ground bracing. Si el nivel del terreno es demasiado lejos para usar Arriostre de Tierra exterior, use Arriostre de Tierra interior. B2Temp 150723 BCSI-B2 SUMMARY SHEET 2015 B2 Summary Sheet.indd 1 The BCSI-B2 Summary Sheet summarizes Section B2 of the BCSI Book, providing options for safe temporary restraint/bracing installations and strongly emphasizing how all lateral restraint must be stabilized with diagonal bracing. It simplifies how to get the first five trusses erected, restrained and braced efficiently and safely. b2temp-d: English/Spanish version. Designed to be included with jobsite packages. Part of the pre-assembled English/Spanish JOBSITE PACKAGE (JOBSITE-D). 8/24/2015 1:36:58 PM CANADAb2-d: English/French version. Designed to be included with jobsite packages. Part of the pre-assembled English/French JOBSITE PACKAGE (CANADAJOBSITE-D). (8 pages) lots of 50 1-9 10-19 20-99 100+ 8 2016 member non-member PRICE EACH LOT PRICE EACH LOT $46.00 44.00 42.00 40.00 $78.00 75.00 71.50 68.00 shipping units x qty. 40 (English/Spanish) 80 (English/French) ORDER ONLINE AT sbcindustry.com/pubs BCSI-B3 Summary Sheet - Permanent Restraint/Bracing of Chords & Web Members “Sway” bracing is installed at the discretion of the building Install the diagonal bracing at an angle of less-than-or-equal-to 45° to the CLR and position so that it crosses the web in close proximity to the CLR. Attach the diagonal brace as close to the top and bottom chords as possible and to each web it crosses. Repeat every 20’ (6.1 m) or less. Instale el arriostre diagonal a un ángulo menos de o igual a 45° al CLR y colóquelo para que cruce la cuerda muy cerca del CLR. Sujete el arriostre diagonal tan próximo a las cuerdas superiores y inferiores como sea posible y a cada cuerda que lo cruza. Repita cada 20 pies (6.1 m) o menos. Permanent continuous lateral restraint ≤45˚ Diagonal* bracing DIAGONAL BRACING ≤45˚ Lateral restraint ≤45˚ Group of 2 Trusses Lateral restraint Use rows of continuous lateral restraint with diagonal Directly attached rigid ceiling WEBREINF 20060409 Web Member Plane Permanent Building Stability Bracing to Transfer Wind & Seismic Forces Arriostre de Estabilidad Permanente del Edificio del Plano de Miembros Secundarios para Desplazar Fuerzas de Viento y Fuerzas Sísmicas axial forces caused by the in-plane loads applied to the truss. Additional restraint and bracing within the web member plane may also be required to transfer lateral forces due to wind and/or seismic loads applied perpendicular to the plane of the trusses. This restraint and bracing is typically specified by the building designer. La restricción o refuerzo de miembros secundarios especificada en un TDD es requerido para resistir la deformación bajo fuerzas axiales causadas por cargas verticales aplicadas al truss. Restricción adicional y el aparato ortopédico dentro del plano miembro de banda también puede ser necesaria para transferir fuerzas laterales debidas al viento y / o cargas sísmicas aplicadas perpendicular al plano de las cerchas. Esta restricción y arriostre es típicamente provisto por el diseñador del edificio. Gable end frame ≤20' (6.1 m) Diagonal braces Lateral restraint & diagonal bracing can also be used with small groups of trusses (i.e., three or less). Attach the lateral restraint & diagonal brace to each web member they cross. Restricción lateral y arriostre diagonal también puede ser usado con grupos pequeños de trusses (ej. tres o menos). Sujete la restricción lateral y el arriostre diagonal a cada miembro secundario que los cruzan. Note: Top chord sheathing not shown for clarity. designer to help stabilize the truss system and minimize the lateral movement due to wind and seismic loads. Arriostre de “sway” está instalado por la discreción del diseñador del edificio para ayudar en estabilizar el sistema de trusses y para minimizar el movimiento lateral debido a cargas de viento y cargas sísmicas. Sway bracing installed continuously across the building also serves to distribute gravity loads between trusses of varying stiffness. Arriostre de “sway” que es instalada continuadamente al través del edificio también es usado para distribuir las cargas de gravedad entre trusses de rigidez variando. Permanent Restraint/Bracing for the Top Chord in a Piggyback Assembly Restricción/Arriostre Permanente para la Cuerda Superior en un Ensamblaje de Piggyback The web member restraint or reinforcement specified on a TDD is required to resist buckling due to sheathing Diagonal brace Diagonal “X” bracing in the top chord plane at intervals specified by the building designer bracing, gypsum board sheathing or some other ceiling material capable of functioning as a diaphragm. Use filas de restricción lateral continua con arriostre diagonal, entablado de yeso o cualquier otro material para techo que pueda funcionar como un diafragma. T, L o REFUERZO DE SCABS Provide restraint and bracing by: Repeat diagonal • using rows of minimum 4x2 stress-graded bracing (red) at 10' lumber CLR and diagonal bracing, or (3 m) intervals, or as • connecting the CLR into the roof diaphragm, specified. or • adding structural sheathing or bracing frames, or • some other equivalent means. Provee restricción y arriostre por: • usando filas de 4x2 CLR de madera graduada por esfuerzo y arriostre diagonal, o • conectando el CLR al diafragma del echo, o • añadiendo entablado estructural o arm zanes de arriostre, o ≤45˚ typ. • algunos otros métodos equivalentes. Horizontal L- reinforcement attached to the top chord of the supporting truss. Consulte el TDD para el espaciamiento máximo supuesto para sujetar la restricción lateral Cap (p. ej., vigas) a la cuerda superior del truss trusses soportante. CLR required only if bracing frame or structural sheathing is installed intermittently restraint and minimum connection requirements between the cap and the supporting truss or restraint. El TDD provee el grosor supuesto de la restricción y los requisitos de conexión mínimos entre la capa y el truss soportante o la restricción. Bracing frame or structural sheathing Supporting trusses If diagonal bracing is used to restrain the Bottom chord lateral restraint Gable end/wall permanent diagonal bracing. Locate in line with bottom chord permanent CLR or as specified by the building designer. CLR (green) at ≤ the spacing specified on the truss design drawing Refer to the TDD for the maximum assumed spacing between rows of lateral restraint (e.g. purlins) The TDD provides the assumed thickness of the Roof diaphragm blocking Note: Some chord and web members not shown for clarity. Structural Group of 3 Trusses grade for the sheathing, purlins and bracing are provided in the building code and/or by the building designer. El tamaño de cierre y requisitos de espaciamiento y grado para el entablado, vigas de soporte y arriostre son provistos en el código del edificio y/o por el diseñador del edificio. 2. Permanent Bracing for the Bottom Chord Plane Arriostre Permanente para el Plano de la Cuerda Inferior T, L OR SCAB REINFORCEMENT VEA DIBUJO DE DISEÑO DE TRUSS PARA INFORMACIÓN ESPECÍFICA REFUERZO DE MIEMBRO SECUNDARIO REQUERIDO Diagonal brace to roof diaphragm blocking *Min. 2x4 stress-graded lumber, typ. Purlins Fastener size and spacing requirements and WEB REINFORCEMENT REQUIRED SEE TRUSS DESIGN DRAWING FOR SPECIFIC INFORMATION that require lateral restraint or reinforcement. Algunos fabricantes de trusses marcan en el truss las ubicaciones de refuerzo o restricción lateral de miembros secundarios con etiquetas similares a las arriba. ≤45˚ on the assumed support for the top chord. El Dibujo del Diseño de Truss (TDD) provee información sobre el soporte supuesto para la cuerda superior. NOTE: WEB MEMBER REINFORCEMENT MAY ALSO BE POSSIBLE; SEE BCSI-B3 LATERAL RESTRAINT RESTRICCIÓN LATERAL PERMANENTE Y ARRIOSTRE DIAGONAL ES REQUERIDO Some truss manufacturers provide additional assistance by using tags to mark the web members Sujete cada fila de CLR en las ubicaciones mostrados en el TDD. ≤45˚ PERMANENT LATERAL RESTRAINT & DIAGONAL BRACING REQUIRED SEE TRUSS DESIGN DRAWING FOR LATERAL RESTRAINT; CONSULT BUILDING DESIGNER AND/OR BCSI-B3 FOR DIAGONAL BRACING VEA EL DIBUJO DE DISEÑO DE TRUSS PARA RESTRICCIÓN LATERAL; CONSULTE AL DISEÑADOR DE EDIFICIO Y/O BCSI-B3 PARA ARRIOSTRE DIAGONAL A. Continuous Lateral Restraint (CLR) & Diagonal Bracing Restricción Lateral Continua (CLR) y Arriostre Diagonal Continuous* lateral restraint The Truss Design Drawing (TDD) provides information Permanent Bracing for Special Conditions Arriostre Permanente Para Condiciones Especiales Sway Bracing—Arriostre de “Sway” www.tpinst.org One restraint required on each of these webs. Note: CLR can be installed on either side of Member. A. Continuous lateral restraint & diagonal bracing, or B. Individual member web reinforcement. Restrinja y arriostre con, A. Restricción lateral continua y arriostre diagonal, o B. Refuerzo de miembros secundarios individuales. Attach each row of CLR at the locations shown on the TDD. EXAMPLES OF DIAGONAL BRACING WITH CONTINUOUS LATERAL RESTRAINT structural purlins that are properly braced. Attach to each truss. Use contrachapado, panel de fibras orientado (OSB), o vigas de soporte de madera o metal que estén arriostrados apropiadamente. Sujete a cada truss. ¡caUteLa! El uso de un armazón hastial de la cuerda inferior con trusses contiguos cuales tienen cuerdas inferiores pendientes es prohibido por algunos códigos de edificios porque arriostre adecuado de esta condición es difícil y a veces imposible. Consideraciones especiales de diseño para el arriostre de la pared de extremo son requeridos por el diseñador del edificio si el perfil del armazón hastial no hace juego con los trusses contiguos. web reInforcemenT for sIngle Ply Trusses1 WTCA – Representing the Structural Building Components Industry & Truss Plate Institute Copyright © 1992-2006 All Rights Reserved Revisa el TDD para determinar cuales miembros secundarios (si algunos) requieren restricción para resistir el torcer. Use plywood, oriented strand board (OSB), or wood or metal caUtiOn! Using a flat bottom chord gable end frame with adjacent trusses that have sloped bottom chords is prohibited by some building codes as adequate bracing of this condition is difficult and sometimes impossible. Special end wall bracing design considerations are required by the building designer if the gable end frame profile does not match the adjacent trusses. La siguiente tabla puede ser usada a menos que información más específica está provista. Individual Web Member Permanent Restraint & Bracing Restricción y Arriostre Permanente de Miembros Secundarios Individuales Restrain and brace with, cauTIon Without permanent bracing the truss, or a portion of its members, will buckle (i.e., fail) at loads far less than design. ¡caUteLa! Sin el arriostre permanente, del truss, o un parte de los miembros, torcerán (ej. fallarán) de cargas muchas menos que las cargas que el truss es diseñado a llevar. Structural sheathing 1. Permanent Bracing for the Top Chord Plane on top chord Arriostre Permanente para el Plano de la Cuerda plane Superior Example of raked gable end wall (with scissors gable end frame) Truss Member, typ. The following table may be used unless more specific information is provided. Truss Member CLR(s), repeat at 10’ (3 m) intervals, or as specified in the construction documents. Si arriostre diagonal es usado para restringir el/los CLR(s), repita en intervalos de 10 pies o como especificado en los documentos de construcción. To view a non-printing PDF of this document, visit sbcindustry.com/b3. Para ver un PDF de este documento que no se puede imprimir, visita sbcindustry.com/b3. Some truss designers provide general design tables and details to assist the building designer in determining the bracing required to transfer lateral loads due to wind and/or seismic forces from the gable end frame into the roof and/or ceiling diaphragm. Algunos diseñadores de trusses proveen tablas y detalles de diseño generales para asistir el diseñador del edificio en determinar el arriostre requerido para pasar cargas laterales debidas a fuerzas de viento y/o fuerzas sísmicas del armazón hastial al diafragma del techo. 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • sbcindustry.com Cargas de construcción son las cargas que están impuestas a los edificios incompletos como resultado del proceso de construcción. Cargas de construcción típicas incluyen el peso de los trabajadores, el equipo y los materiales de construcción, etcétera. Por ejemplo, un paquete de entablado contrachapado o tabla de yeso apilados temporalmente sobre los trusses crean cargas de construcción. Construction loads are those loads imposed on the unfinished building as a result of the construction process. Typical construction loads include the weight of the workers, equipment, and building materials, to name a few. For example, a bundle of plywood sheathing or gypsum board stacked on trusses temporarily creates construction loads. restringido y arriostrado según las pautas en BCSI-B1*** y BCSI-B2 *** antes de colocar alguna carga de construcción en la estructura. Solamente coloquen cargas de construcción arriba de estructuras cuales son restringidos y arriostrados completamente. braced according to the guidelines in BCSI-B1*** and BCSI-B2*** before placing any construction loads on them. Construction loads shall only be placed on fully restrained and braced structures. ¡ADVERTENCIA! Apilando cantidades excesivas de cargas de construcción sobre trusses de piso u techo es una práctica peligrosa. Daño a la propiedad, herida personal y/o muerte son posibles si no sigue esta advertencia. WARNING Stacking excessive amounts of construction materials on floor or roof trusses is an unsafe practice. Property damage, personal injury and/or death are possible if this warning is not heeded. Los trusses que han sidos demasiado estresados debido a cargas de construcción excesivas usualmente demuestran una desviación excesiva, y por lo menos una parte de este desviación se quedarán aún después de que la carga se haya quitada. En casos más severos, miembros quebrados del truss y/o junturas falladas pueden resultar. Trusses that have been over-stressed due to excessive construction loading will usually show excessive sagging (deflection) and at least a portion of this deflection will remain even after the load has been removed. In more severe cases, broken truss members and/or failed truss joints may result. Construction Loading DO's and DON’Ts DON’T stack materials on unbraced trusses. Que HACER y NO HACER Con Las Cargas De Construccion DON’T overload the trusses. NO amontone materiales sobre trusses que no esten arriostrados. NO sobrecargue los trusses. DON’T exceed stack heights listed in the table. NO exceda la altura de montón indicada en la tabla que sigue. Height – Altura 12" – 12 pulgadas Plywood or OSB – Madera Contrachapada u OSB 16" – 16 pulgadas Asphalt Shingles – Teja de Asfalto 2 bundles – 2 paquetes Concrete Block – Bloque de Hormingón 8" – 8 pulgadas Clay Tile – Teja de Arcilla Truss PlaTe InsTITuTe 218 N. Lee St., Ste. 312 • Alexandria, VA 22314 703-683-1010 • tpinst.org B3WEB11x17 150723 b4constload-d: English/Spanish version. Designed to be included with jobsite packages. Part of the pre-assembled English/Spanish JOBSITE PACKAGE (JOBSITE-D). Properly restrain and brace trusses before stacking construction materials on them. Diagonal Bracing Lateral Restraint Maximum Stack Height for Material on Trusses1,2 Maximua Altura de Montón para Material encima de los Trusses Material – Material Gypsum Board – Tabla de Yeso Structural Sheathing 3-4 tiles – 3-4 azulejos 1 This table is based on trusses designed with a live load of 40 psf or greater. For other loading conditions, contact a Registered Design Professional. 2 Limit stacking periods to approximately one week, unless alternative information is provided by the Building Designer, Truss Designer or Truss Manufacturer. B4ConstLoad 150715 RESTRICCIóN/ARRIOSTRE PERMANENTE DE lAS CUERDAS Y lOS MIEMBROS SECUNDARIOS BCSI-B4 SUMMARY SHEET Tramos sobre 60 pies o más pueden requerir arriostre permanente complejo. Por favor, consulte siempre a un profesional registrado de diseño. 2015 B3 Summary Sheet.indd 1 þ Asegúrese que el montaje del truss está adecuadamente þ Make sure that the truss assembly is properly restrained and 7/30/2015 12:54:27 PM 2015 B4 Summary Sheet.indd 1 7/22/2015 11:07:43 AM b3flat-p: Flat 11”x17” in English/Spanish. Perfect for printing truss placement diagrams on the reverse side. CANADAB4-d: English/French version. Designed to be included with jobsite packages. Part of the pre-assembled English/French JOBSITE PACKAGE (CANADAJOBSITE-D). CANADAB3Flat-P: Flat 11”x17” in English/ French. Perfect for printing truss placement diagrams on the reverse side. (2 pages) lots of 50 b3flat-P and CANADAb3flat-P lots of 250 1-4 5-10 11-20 21-49 50+ member non-member PRICE EACH LOT PRICE EACH LOT $80.00 75.00 71.00 68.00 65.00 $136.00 127.00 120.00 115.00 110.00 1-9 10-19 20-99 100+ shipping units x qty. 100 (English/Spanish) 180 (English/French) B5 DON’T cut truss members. The modification shown in this photo needs to be repaired. NO corte los miembros de los trusses. La modificación mostrada en esta foto necesita una reparación. mente: 1. Arriostrar o soportar el truss temporalmente para prevenir más daño al truss y peligro potencial a los trabajadores. Damaged plate 1. Temporarily brace or support the truss to prevent further damage to the truss and potential dangerto workers. 2. Report damage, alterations or installation errors to the truss manufacturer immediately. Failure to report may void any warranties. 2. Reporte daño, alteraciones o errores de instalación al fabricante de los trusses inmediatamente. Falta de reportarlo puede poner en nulo la garantía. Removed plate 3. No intente a reparar el truss sin unas Instrucciones de Reparación del diseñador del edificio, diseñador del truss o el fabricante del truss. Drilled hole Examples of Damage or Alterations 4. Antes de empezar la reparación, poner el truss plano en un superficie sólido y llano. Si el truss ya está instalado, apuntalar el truss para aliviar alguna carga. 3. Do not attempt to repair the truss without a Repair Detail from the building designer, truss designer or truss manufacturer. 5. Reparar el truss por seguir exactamente la información provista en las Instrucciones de Reparación. Asegúrese que use los materiales correctos como es especificado. Busca el guía profesional si algo está vago. 4. Prior to beginning the repair, lay the truss flat on a solid, level surface. If the truss is already installed, shore up the truss to relieve any load. 6. Guarde las Instrucciones de Reparación en caso de que el inspector de edificios, diseñador del edificio o dueño las solicite. 7. Si la Instrucción de Reparación no es para la condición específica que está reparando, no usarla. Siempre siga las Instrucciones de Reparación, específicamente preparado para su situación exacta. 6. Keep the Repair Detail in case the building official, building designer or owner requests it. 7. If the Repair Detail is not for the specific field condition being repaired, do not use it. Always follow the Repair Detail prepared for your specific situation. b3fold-P and CANADAb3fold-P $544.00 508.00 480.00 460.00 440.00 Nailed or pressed plate Plywood or oriented strand board (OSB) gussets over damaged plates or joints. Metal nail-on plates. N/A Madera contrachapada u panel de fibras orientadas (OSB) escudese sobre chapas dañadas o junturas. (2 pages) lots of 50 Chapas de truss aplicadas por una prensa portátil. No intente a reparar el truss sin Instrucciones de Reparación del diseñador del edificio, diseñador del truss o fabricante de truss. Lumber scabs or repair frames over broken chords and/or webs. Truss plates applied by a portable press. B5Repair 150422 2015 B5 Summary Sheet.indd 1 member non-member PRICE EACH LOT PRICE EACH LOT 1-9 10-19 20-99 100+ 5/15/2015 9:50:31 AM 300 (English/Spanish) 600 (English/French) & J O B S I T E P A C K A G E S shipping units x qty. $14.00 13.50 13.00 12.00 $24.00 23.00 22.00 20.00 10 b7fold-p and CANADAb7fold b7flat-p and CANADAb7fLAT b7 summary Sheet - Temporary and Permanent Restraint/ Bracing for Parallel Chord Trusses B7 Truss Design Drawings may specify locations of permanent lateral restraint for individual truss members. Refer to the BCSi-B3*** for more information. All other permanent bracing design is the responsibility of the building designer. Las recomendaciones de restricción y arriostre provistas en este documento tratan los Trusses de Cuerdas Paralelas (PCT) fabricados con la caraancha de la madera orientada horizontalmente. Refiera al BCSi-B2*** para las recomendaciones de restricción y arriostre para PCT construido con la cara-ancha de la madera orientada verticalmente. Los Dibujos del Diseño de Truss pueden especificar las ubicaciones de restricción lateral permanente para miembros individuos del truss. Refiera al BCSi-B3*** para más información. Todo del otro diseño de arriostre permanente es la responsabilidad del diseñador del edificio. 1) Coloque el primer truss y sujetarlo seguramente a la estructura soportante. 2) Coloque los próximos cuatro trusses al extremo del espacio, clavando apropiadamente los trusses en todos lugares de cojinetes. Asegure los extremos de los trusses soportantes de la cuerda inferior con el arriostre diagonal, el bloqueando o la tabla de borde cuando cada truss está instalado (vea las figuras en la próxima columna). Using a single pick at the mid-span can damage the truss. El uso de un solo lugar en el medio-tramo o para levantar puede hacer daño al truss. 3) Arriostre este ensamblaje de cinco trusses por sujetar el entablado estructural a las cuerdas superiores o por añadir 2x4 restricción lateral y arriostre diagonal (vea las tablas y figures en la próxima columna). Toe-in Tagline Approx. ½ truss length TRUSSeS UP TO 30' (9.1 m) Tagline Toe-in Spreader bar ½ to ²/³ truss length TRUSSeS UP TO 60' (18.3 m) Hold each truss in position with the erection equipment until top chord temporary lateral restraint is installed and the truss is fastened to the bearing supports. Sostenga cada truss en posición con equipo de grúa hasta que la restricción lateral temporal de la cuerda superior esté instalado y el truss está sujetado a los soportes. ReCOMMeNDATiONS FOR LiFTiNG SiNGLe TRUSSeS BY HAND ReCOMMeNDACCiONeS PARA LevANTAR TRUSSeS iNDiviDUALeS POR LA MANO Chord Size CAUTiON Use special care in windy conditions or near power lines and airports. The contractor is responsible for properly receiving, storing and handling the trusses at the jobsite. ¡CAUTeLA! Utilice cuidado especial en días ventosos o cerca de cables eléctricos o de aeropuertos. CAUTiON Seek help if lifting by hand as trusses can be heavy and awkward. iNSTALLATiON AND TeMPORARY ReSTRAiNT & BRACiNG STANDARD eND BeARiNG DeTAiLS Make sure bottom chord bearing PCT are installed with the correct side up and in the correct orientation. Refer to the Truss Design Drawing. Use proper rigging and hoisting equipment. Use equipo apropiado para levantar e improvisar. COMMON iNSTALLATiON eRRORS This truss is installed “backwards” and “upside down.” 6 Intended bearing location This truss is installed correctly. “Ribbon notch” should be on top “Ribbon notch” should be on top here to instruct and warn the contractor to correctly install the PCT. Muchos fabricantes de trusses usan placas suplementarias, tal como las mostradas aquí, para instruir y advertir el contratista de como instalar el PCT correctamente. DO NOT walk on unbraced Trusses. NO camine en trusses sueltos. WARNiNG Lateral restraint and diagonal bracing of PCT are very important. 8' - 10' max. Use a minimum of 2x4 stress-graded lumber for lateral restraint and diagonal bracing and attach to each truss with a minimum of 2-10d (0.128x3”) nails, unless otherwise specified. HOiSTiNG ReCOMMeNDATiONS FOR TRUSS BUNDLeS ReCOMeNDACiONeS PARA LevANTAR PAQUeTeS De TRUSSeS Utilice el mínimo de 2x4 madera graduada por esfuerzo para la restricción lateral y arriostre diagonal y sujetar a cada truss con un mínimo de 2-10d (0.128x3”) clavos, a menos que es especificado de otro modo. STePS TO SeTTiNG TRUSSeS DON’T overload the crane or lift. NeveR use banding to lift a bundle. NO sobrecargue la grúa o ascensor. NUNCA use las ataduras para levantar un paquete. A single lift point may be used for securely banded bundles of trusses up to 30’ (13.7 m). Puede usar un solo lugar de levantar para paquetes firmamente atados juntos de trusses hasta 30 pies. Place truss bundles in a stable position. Banding, typ. Puse paquetes de trusses en una posición estable. WARNiNG Do not over load supporting structure with truss bundle. ¡ADveRTeNCiA! No sobrecargue la estructura soportante con el paquete de trusses. concerning strongbacking installed to control deflection and vibration. contractor in correctly installing strongbacking. 1) Set first truss and attach securely to supporting structure. 2) Set next four trusses at end of bay, properly nailing the trusses at all bearing locations. Secure the ends of bottom chord bearing trusses with diagonal bracing, blocking or rim board as each truss is installed (see figures, in column to the right). 3) Brace the five-truss-assembly by attaching structural sheathing to the top chords or by adding 2x4 lateral restraint and diagonal bracing (see table and figures, in column to the right). 4) Continue setting trusses, making sure to properly attach each truss at the bearing locations. 5) Restrain and brace the trusses as they are being installed by attaching structural sheathing, or rows of top chord lateral restraint, at the spacing provided in the table in the column to the right, and with diagonal bracing to the top chord (and end vertical web if bottom chord bearing truss) at intervals of no more than 30’ (9.1 m) along the run of trusses. see truss design drawing for specific information 2x6 strongback at 10' o.c. 2x6 espaLda fuerte en 10' o.c. CABALLETE DE "STRONGBACKiNG" RECOMENDADA Vea dibujo de diseño de truss para información específica CONSTRUCTiON LOADiNG DO NOT proceed with construction until all lateral restraint and diagonal bracing is securely and properly in place. ≤45°, typ. NO procede con la construcción hasta que toda la restricción lateral y arriostre diagonal es seguramente y apropiadamente en lugar. DO NOT exceed maximum stack heights in table at right. NO exceda las alturas máximas de montón en la tabla a la derecha. All Lateral Restraint lapped at least two Trusses. STRONGBACKiNG RECOMMENDED Muchos fabricantes de trusses incluyen una placa suplementaria para asistir más el contratista en la instalación correcta de strongbacking. Repeat Diagonal Bracing every 15 Truss spaces (30' max.) NeveR overload small groups or single trusses. End diagonal brace. See and figures below. Repeat every 15 truss spaces (30' max.) NUNCA sobrecargue grupos pequeños o trusses individuales. DO NOT lean stacks of materials against walls. End diagonal braces, with TCTLR or ribbon (band) board, blocking panels, or Rim board (see Figures below) are examples of framing components that provide stability to bottom chord bearing PCT during installation. Install one of these types of components at both ends of the truss system and repeat every fifteen truss spaces (30’ maximum) as shown above. Los diagonales extremos, con TCTLR o tabla de listón (banda), paneles de bloquear, o tabla de borde (vea figuras abajo) son ejemplos de componentes de arriostramiento que proveen estabilidad a los PCTs soportantes de la cuerda inferior durante la instalación. Instale uno de estos tipos de componentes en ambos extremos del sistema de truss y repite cada 15 espacios de truss (30’ máximo), como mostrado más arriba. NO permite que montones de materiales se apoyen en las paredes. DON’T drop loads of any material on trusses. Maximum Stack Height for Material on Trusses Material Height Gypsum Board 12" (305 mm) Plywood or OSB 16" (406 mm) Asphalt Shingles 2 bundles Concrete Block 8" (203 mm) Clay Tile 3-4 tiles high NO deje caer cargas de ningunos materiales en los trusses. Position load over as many trusses as possible with longest dimension of material perpendicular to Trusses. Coloque la carga sobre tantos trusses como sea posible con la dimensión más larga perpendicular a los trusses. Place material next to outside Load bearing wall or directly over interior bearing wall. TCTLR with Diagonal Brace Ribbon board with Diagonal Brace Blocking panel Coloque el material al lado de la pared soportante de cargas exterior o directamente sobre la pared soportante interior. Rim board Refer to BCSi-B4*** for more information about construction loading. PeRMANeNT ReSTRAiNT & BRACiNG Refiera al BCSi-B4*** para más información sobre cargas de construcción. Permanently restrain and brace the top chords of the PCT with properly sized and attached struc- ALTeRATiONS DO NOT cut, alter, or drill any structural member of a truss unless specifically permitted by the Truss Design Drawing. Restringe y arriostre permanentemente las cuerdas superiores del PCT con el entablado estructural sujetado del tamaño apropiado. NO corte, altere o perfore ningún miembro estructural de un truss a menos que esté específicamente permitido en el Dibujo del Diseño de Truss. Permanently restrain and brace the bottom chords of the PCT with directly applied gypsum board ceiling or with rows of lateral restraint installed at 10’ on-center along the truss span and diagonal bracing installed at no more than 20’ intervals along the run of trusses, unless otherwise specified. Trusses that have been overloaded during construction or altered without the Truss Manufacturer’s prior approval will render the Truss Manufacturer’s limited warranty null and void. Restringe y arriostre permanentemente las cuerdas inferiores del PCT con techo de panel de yeso aplicado directamente o con filas de restricción lateral instalado a 10’ en-centro al lado del tramo de truss y arriostre diagonal instalado en no más de intervalos de 20’ al lado de la línea de trusses, a menos que especificado de otro modo. Trusses que se han sido sobrecargados durante la construcción o han sido alterados sin la autorización previa del Fabricante de Truss, pueden hacer nulo y sin efecto la garantía limitada del Fabricante de Trusses. Install structural sheathing, ribbon board with structural sheathing, blocking panels, or rim board ¡ADveRTeNCiA! La restricción lateral y el arriostre diagonal de PCT son muy importantes. Keep trusses banded together until installation begins. Guarde los trusses atados juntos hasta que la instalación empiece. Refer to Chapter B7 of BCSi***, and finish flooring specifications for additional information 15’ on-center** Diagonal Bracing ≤45°, typ. Apply Diagonal Brace to vertical webs at end of cantilever and at interior and exterior bearing locations tural sheathing. Many truss manufacturers use supplemental tags such as the ones shown Sujete los extremos de cada fila de strongbacking a una pared u otra restricción de extremo segura. Mantenga la continuidad de cada fila de strongbacking tanto como sea posible. Si requiere que ser cortado, quitado o modificado, tiene que mantener la continuidad en las secciones contiguos del piso como fue determinado por el diseñador que especifiqué el strongbacking. Many truss manufacturers include a supplemental tag to further assist the 10’ on-center** 4x2 near each end. Trusses con tramos menos de o igual a 30’ deben ser levantados en lugar por levantando en o cerca de cada extremo. Asegure que los PCT para el soporte de la cuerda inferior son instalados con el lado correcto hacia arriba y en la orientación correcta. Refiera al Dibujo del Diseño de Truss. Trusses pueden ser descargados directamente en el piso en el tiempo de la entrega o almacenados temporalmente en contacto con el piso después de la entrega. Para trusses almacenados por más de una semana, ponga bloqueando de altura suficiente debajo de la pila de trusses a 8’ hasta 10’ en el centro (o.c.) y cubra los paquetes para prevenir el aumento de humedad pero permita ventilación. continuity of each row of strongbacking as much as possible. If required to be cut, removed, or modified, continuity with the adjoining floor sections must be maintained as determined by the designer specifying the strongbacking. Refiera al Capítulo B7 de BCSi***, y termina las especificaciones del piso para información adicional con respecto a strongbacking instalado para controlar el desvío y la vibración. TCTLR Spacing 3x2 10' or 15'** Trusses with spans less than or equal to 30' (9.1 m) should be raised into position by lifting at or Avoid lateral bending. Evite la flexión lateral. Trusses may be unloaded directly on the ground at the time of delivery or stored temporarily in contact with the ground after delivery. If trusses are to be stored for more than one week, place blocking of sufficient height beneath the stack of trusses at 8’ (2.4 m) to 10’ (3 m) on-center (o.c.) and cover bundles to prevent moisture gain but allow for ventilation. Attach the ends of each row of strongbacking to a wall or other secure end restraint. Maintain Maximum Spacing for Top Chord Temporary Lateral Restraint (TCTLR) ¡CAUTeLA! Pide ayuda si levantando a mano porque los trusses pueden ser pesados y difíciles. El contratista tiene la responsabilidad de recibir, descargar y almacenar adecuadamente los trusses en la obra. 5) Restringe y arriostre los trusses mientras ellos son instalados por sujetar el entablado estructural, o filas de restricción lateral de la cuerda superior al espaciamiento provisto en la tabla en la próxima columna con arriostre diagonal a la cuerda superior (y el miembro secundario vertical del extremo, si es un truss soportante de la cuerda inferior) en intervalos de no más de 30’ al lado de la línea de trusses. Los trusses de 20’ o menos pueden ser levantados en lugar por levantando en o cerca del pico. ¡CAUTeLA! Lleve equipo protectivo personal para los ojos, los pies, las manos y la cabeza cuando trabaje con trusses. Strongbacking aumenta el desempeño de los trusses por limitar el desvío diferencial entre trusses contiguos y reducir la vibración. Utilice las siguientes pautas para instalar strongbacking: - Use madera de 2x6 mínimo (nominal) orientada con la cara-ancha vertical. - Espacie las filas de strongbacking en no más de 10’ en centro. - Sujete el strongbacking a cada truss. Sujete a los miembros verticales o costras con un mínimo de tres (3) 10d (0.131x3.0”) clavos. 4) Continué la colocación de los trusses, y asegure de sujetar apropiadamente cada truss en las ubicaciones de cojinetes. 60° or less Trusses 20' (6.1 m) or less can be raised into position by lifting at or near the center. STORAGe & HANDLiNG N/A PASOS PARA iNSTALAR LOS TRUSSeS HOiSTiNG ReCOMMeNDATiONS FOR SiNGLe TRUSSeS ReCOMeNDACiONeS PARA LevANTAR TRUSSeS iNDiviDUALeS Refiera al BCSi – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses*** para información más detallada sobre el manejo, instalación, restricción y arriostre de todos tipos de trusses y todas configuraciones. CAUTiON Wear personal protective equipment for the eyes, feet, hands and head when working with trusses. shipping units x qty. This 11"x17" document provides a summary of temporary and permanent restraint/bracing guidelines included in Section B7 of the BCSI Book for 3'x2' and 4'x2' parallel chord trusses, as well as information on handling and installing these products. Also included is information concerning construction loads, what to do if trusses are damaged or modified, and the special condition of attaching a residential deck to the trusses. B7 BCSI-B7 SUMMARY SHEET – GUIDE FOR HANDLING, INSTALLING & BRACING OF 3x2 & 4x2 PARALLEL CHORD TRUSSES GeNeRAL NOTeS The restraint and bracing recommendations provided in this document address Parallel Chord Trusses (PCT) built with the wide-face of the lumber oriented horizontally. Refer to BCSi-B2*** for restraint and bracing recommendations for PCT built with the wide-face of the lumber oriented vertically. Refer to BCSi – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses*** for more detailed information on the handling, installing, restraining and bracing of all truss types and configurations. $ .22 per use miembros secundarios rotos. ¡ADveRTeNCiA! El resultado del manejo, levantamiento, instalación, restricción y arriostre incorrecto de PCT puede ser la caída de la estructura, o aún peor, heridos o muertos. 500 minimum Cada Instrucción de Reparación está generada en base de casopor-caso, porque trusses y el tipo de daño pueden varían mucho. Ejemplos de reparaciones comunes incluyen: Chapas de metal que se clavan. Costras de madera o armazón de reparación sobre cuerdas o Lumber scab Do not attempt to repair the truss without a Repair Detail from the building designer, truss designer or truss manufacturer. WARNiNG The consequences of improper handling, erecting, installing and bracing of PCT can result in a collapse of the structure, or worse, serious personal injury or death. non-member price each set 24 (English/Spanish) 60 (English/French) B C S I BCSI-B5 SUMMARY SHEET The Architectural CAD D-size version of the bilingual B3 Summary Sheet is designed for specifiers to use in the electronic plans and submittal process. Summarizing Section B3 of the BCSI Book, this 24"x36" document explains how some planes of a truss must be restrained/braced and provides installation guidelines. member price per lot Técnicas Comunes De Reparación Plywood or OSB gusset Each Repair Detail is generated on a case-by-case basis, since trusses and the type of damage vary considerably. Examples of common repairs include: B3CAD-E BCSI-B3 Summary Sheet CAD 24"x36" number of uses per year 8. Si no puede hacer la reparación designada, informe el diseñador del edificio, diseñador del truss o fabricante del truss. 8. If the designed repair cannot be accomplished, inform the building designer, truss designer or truss manufacturer. Common Repair Techniques shipping units x qty. ¡advertencia! Daño, modificaciones en la obra, o instalación incorrecta reducirán la fuerza del truss. Póngase en contacto con el diseñador del edificio, diseñador del truss o fabricante del truss para remediar algunos daños, modificaciones y/o problemas de instalación. Si un truss está dañado, cambiado o instalado incorrecta- Cracked web If a truss is damaged, altered or improperly installed: Trusses de madera conectados con chapas de metal son componentes estructurales prefabricados, montados con miembros de madera y chapas de metal para conexión y son diseñados para llevar cargas sobrepuestos. Siga Estos Pasos Para Corregir Daño, Modificaciones Y Errores Follow These Steps to Correct Damage, Modifications and Errors 5. Repair the truss by following the information provided on the Repair Detail exactly. Make sure to use the correct materials as specified. Seek professional guidance if anything is unclear. $320.00 300.00 284.00 272.00 260.00 $24.00 23.00 22.00 20.00 The BCSI-B5 Summary Sheet reviews how trusses are engineered components. This document provides guidance about how to report damage, modifications or installation errors to the Truss Manufacturer/Design Professional in order to get an approved Truss Repair Detail. It also reviews some common types of damage and modifications. This bilingual (English/Spanish) document summarizes Section B5 of the BCSI Book. Truss Damage, Jobsite Modifications and Installation Errors Daño a los Trusses, Modificaciones en la Obra y Errores de Instalación Metal plate connected wood trusses are prefabricated structural components, assembled with wood members and metal connector plates and designed to carry superimposed loads. Warning Damage, jobsite modifications or improper installation will reduce the strength of a truss. Seek professional assistance from the building designer, truss designer or truss manufacturer to remedy any damage, modifications and/or installation issues. CANADAB3Fold-P: 11"x17" folded to 8.5"x11" in English/French. Perfect size for jobsite packages. Part of the English/French JOBSITE PACKAGE (CANADAJOBSITE-D). 1 2 3-5 6-12 13+ $14.00 13.50 13.00 12.00 b5repair-d B5 Summary Sheet - Truss Damage, Jobsite Modifications and Installation Errors b3fold-p: 11"x17" folded to 8.5"x11" in English/ Spanish. Perfect size for jobsite packages. Part of the English/Spanish JOBSITE PACKAGE (JOBSITE-D). member non-member lots of 1,000 PRICE EACH LOT PRICE EACH LOT b4constload-d and CANADAb4-d member non-member shipping PRICE EACH LOT PRICE EACH LOT units x qty. sbr 20070109 Note: Some chord and web members not shown for clarity. Check the TDD to determine which web members (if any) require restraint to resist buckling. Bottom chord plane Trusses requieren arriostre permanente dentro de TODOS los siguientes planos: 1. Plano de la cuerda superior 2. Plano de la cuerda inferior 3. Plano del miembro secundario of the following planes: 1. Top chord plane 2. Bottom chord plane 3. Web member plane A Lateral Minimum 2' 2x_ Scab block centered restraint over CLR splice. 2x4x12' Attach to CLR with minimum 8-16d or greater (0.135x3.5") nails each lapped over side of splice or as specified by the two trusses or CLR splice Building Designer. reinforcement. SECTION A-A ≤20' (6.1 m) ≤10' (3 m) Web member permanent bracing collects and transfers buckling restraint forces and/or lateral loads from wind and seismic forces. The same bracing can often be used for both functions. Arriostre permanente de los miembros secundarios recogen y pasan fuerzas de restricción de torcer y/o cargas laterales de viento y fuerzas sísmicas. A menudo el mismo arriostre puede ser usado para ambos funciones. www.sbcindustry.com Top chord plane of proper bottom chord plane restraint & bracing unless special bracing is designed to support the end wall. El armazón hastial siempre debe encajar el perfil de los trusses contiguous para permitir la instalación de restricción y arriostre apropiada de la cuerda inferior a menos que arriostre especial es diseñado para soportar la pared de extremo. www.tpinst.org Trusses require permanent bracing within ALL Web member plane ~ a) prevents out-of-plane buckling of truss members, b) helps maintain proper truss spacing, and c) resists and transfers lateral loads from wind and seismic forces. El arriostre permanente es importante porque, a) impide el torcer fuera-de-plano de los miembros del truss, b) ayuda en mantener espaciamiento apropiado de los trusses, y c) resiste y pasa las cargas laterales de viento y fuerzas sísmicas aplicadas al sistema del truss. ≤10' (3 m) 3. Permanent Bracing for the Web Member Plane Arriostre Permanente papa El Plano del Miembro Secundario PLB 20100304 Permanent bracing is important because it, ≤10' (3 m) Lateral restraint and diagonal bracing used to brace the bottom chord plane. PLATE HERE 2 3 A ≤10' (3 m) Minimum Number of Nails per Connection 10d (0.128x3”) 12d (0.128x3.25”) 16d (0.131x3.5”) 10d (0.128x3”) 12d (0.128x3.25”) 16d (0.131x3.5”) www.tpinst.org Minimum Nail Size 2x6 stress-graded PLATE HERE Lumber Size 2x4 stress-graded Other attachment requirements may be specified by the building designer or truss designer. The grade/size and attachment for bracing materials such as wood structural panels, gypsum board sheathing, proprietary metal restraint/bracing products, and metal purlins and straps are provided by the building designer. Permanent Bracing for the Various Planes of a Truss Arriostre Permanente para Varios Planos de un Truss The gable end frame should always match the profile of the adjacent trusses to permit installation Bottom chord plane Structural Building Components Association & Truss Plate Institute Copyright © 1992-2010 All Rights Reserved MINIMUM ATTACHMENT REQUIREMENTS FOR LUMBER RESTRAINT/BRACING1,2 1 2 B. Individual Web Member Reinforcement Refuerzo de Miembros Secundarios Individuales T-, L-, Scab, I-, U-Reinforcement, proprietary metal reinforcement and stacked web products provide an alternative for resisting web buckling. T-, L-, costra, I-, U-Refuerzo, refuerzo de metal patentando y productos de miembros secundarios amontonados proveen una alternativa para resistir el torcer de los miembros secundarios. 2x_ CLR PLATE HERE CLR splice reinforcement Truss Member ≤45˚ typ. wtca – representing the structural building components industry & truss plate institute copyright © 1992-2007 all rights reserved by the building designer with a maximum of 10’ (3 m) on-center. Instale restricción lateral permanente de la cuerda inferior al espaciamiento indicado en el TDD y/o por el diseñador del edificio con un máximo de 10 pies en el centro. Diagonal bracing. Attach to each truss. Gable End Frames and Sloped Bottom Chords Armazones Hastiales Y Cuerdas Inferiores Pendientes ALWAYS DIAGONALLY BRACE THE CONTINUOUS LATERAL RESTRAINT! ¡SIEMPRE ARRIOSTRE LA RESTRICCIÓN LATERAL CONTINUA DIAGONALMENTE! El TDD provee información sobre el soporte supuesto para la cuerda inferior. Install bottom chord permanent lateral restraint at the spacing indicated on the TDD and/or www.sbcindustry.com The TDD provides information on the assumed support for the bottom chord. Bottom chords stress-graded lumber, proprietary metal products, and metal purlins and straps. Materiales comunes de arriostrar/restringir incluyen paneles estructurales de madera, entablado de yeso, madera graduada por esfuerza, productos de metal patentados, y vigas de soporte y tiras de metal. www.sbcindustry.com Warning Disregarding permanent restraint/bracing is a major cause of truss field performance problems and has been known to lead to roof or floor system collapse. ¡advertencia! Descuidar el arriostre/restricción permanente es una causa principal de problemas de rendimiento del truss en campo y había conocido a llevar al derrumbamiento del sistema del techo o piso. caUtiOn! Trusses with clear spans of 60 feet (18.3 m) or greater, may require complex permanent bracing. Please always consult a registered design professional. ¡caUteLa! Tramos sobre 60 pies o más pueden requerir arriostre permanente complejo. Por favor, consulte siempre a un profesional registrado de diseño. Restraint/Bracing Materials & Fastener Materiales y Cierres de Restricción/Arriostre Commonly used restraint/bracing materials include wood structural panels, gypsum board sheathing, The BCSI-B4 Summary Sheet covers how trusses must not support any loads from equipment or construction materials during construction until the truss assembly is properly restrained and braced. It lists safe stack heights for several materials and illustrates good and bad loading practices. This document summarizes Section B4 of the BCSI Book. Construction Loading Cargas de Construcción Refer also to BCSi-B5*** Truss Damage, Jobsite Modifications & Installation Errors. (see figures above) at the bearing locations of bottom chord bearing PCT as specified by the building designer to transfer lateral diaphragm forces to the shearwalls. Install solid blocking directly beneath load bearing columns to maintain load path through floor to support below. Attachment of residential decks to trusses requires the use of a standard detail provided by the truss manufacturer or by a registered design professional. An alternative is to use a free standing deck. Strongbacking enhances truss performance by limiting differential deflection between adjacent trusses and reducing vibration. Use the following guidelines when installing strongbacking: Use a minimum of 2x6 (nominal) lumber oriented with the wide-face vertical. Space rows of strongbacking at no more than 10’ on-center. Attach strongbacking to each truss. Attach to vertical webs or scabs with a minimum of three (3) 10d (0.131x3.0”) nails. La sujeción de terrazas residenciales a los trusses requiere el use de un detalle estándar provisto por el fabricante de truss o un profesional registrado de diseño. El uso de una terraza independiente es un alternativo. Solid blocking Instale el bloquendo sólido al truss directamente debajo las columnas soportantes arribas para mantener un sendero de carga por el piso para soportar abajo. STRONGBACKiNG También refiera al BCSi-B5*** Daño a los Trusses, Modificaciones en la Obra y Errores de Instalación. SPeCiAL CONDiTiONS Instale el entablado estructural, tabla de listón con entablado estructural, paneles de bloqueando, o tabla de borde (vea las figuras más arriba) en los lugares de cojinetes del truss soportante de la cuerda inferior como especificado por el diseñador del edificio para transferir las fuerzas laterales de diafragma a los paredes portantes. Refer to SBCA Research Report, SRR No. 1408-01, Attachemnt of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems for special blocking details and attachment requirements (sbcindustry.com). Refiera al SBCA Informe de Investigación – Attachment of Residential Deck Ledger to Metal Plate Connected Wood Floor Systems para detalles especiales de bloquear y requisitos de sujetar. (sbcindustry.com). DO NOT attach the deck ledger to 2x_ ribbon board unless a special detail has been provided by the truss designer or building designer. Copyright © 2015 Structural Building Components Association and Truss Plate Institute. All rights reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America. Truss Clear Spans of 60’ or greater may require complex permanent bracing. Please always consult a Registered Design Professional. B4 The BCSI-B3 Summary Sheet explains how some planes of a truss must be restrained/ braced and provides installation guidelines. This document summarizes Section B3 of the BCSI Book and is available in several different formats and languages. B3 BCSI-B3 SUMMARY SHEET - PERMANENT RESTRAINT/BRACING OF CHORDS & WEB MEMBERS This document summarizes the information provided in Section B3 of the 2013 Edition of Building Component Safety Information BCSI – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. Copyright 2004-2015 Structural Building Components Association and Truss Plate Institute. All rights reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. This document should appear in more than one color. Printed in the United States of America. B3 BCSI-B4 Summary Sheet - Construction Loading NO sujete la saliente de la terraza a borde de listón de 2x a menos que un detalle especial ha sido provisto por el diseñador del truss o el diseñador del edificio. *** Contact the Component Manufacturer for more information or consult a Registered Design Professional for assistance. B7PCT150422 HOJA RESUMEN DE LA GUÍA DE BUENA PRÁCTICA PARA EL MANEJO, INSTALACIÓN Y ARRIOSTRE DE LOS TRUSSES DE CUERDAS PARALELAS DE 3X2 Y 4X2 2015 B7 Summary Sheet.indd 1 4/23/2015 12:54:18 PM b7fold-P and CANADAB7FOLD b7flat-P and CANADAB7FLAT lots of 250 1-4 5-10 11-20 21-49 50+ 2016 member non-member PRICE EA. LOT PRICE Ea. LOT $80.00 75.00 71.00 68.00 65.00 $136.00 127.00 120.00 115.00 110.00 shipping units x qty. lots of 1,000 100 (English/Spanish) 180 (English/French) 1 2 3-5 6-12 13+ member non-member PRICE EA. LOT PRICE EA. LOT $320.00 300.00 284.00 272.00 260.00 $544.00 508.00 480.00 460.00 440.00 shipping units x qty. 300 (English/Spanish) 600 (English/French) ORDER ONLINE AT sbcindustry.com/pubs 9 b8toenail-d B8 Summary Sheet - Using Toe-Nailed Connections To Attach Trusses at Bearing Locations B8 Toe-nailed connections are often used to attach trusses to their supports. As with any connection, toe-nailing must be capable of resisting and transferring the applicable loads. Conexiones clavados-oblicuamente son usadas a menudo para sujetar los trusses a los soportes. Tan como con alguna conexión, el clavando-oblicuamente necesita tener la capaz de resistir y transferir las cargas aplicables. FACTORS AFFECTING THE STRENGTH OF A TOE-NAILED CONNECTION LOS FACTORES QUE AFECTAN LA FUERZA DE UNA CONEXIÓN CLAVADO-OBLICUAMENTE 2. Grade and Species of Wood: 1. Proper Installation: Start the nails at a distance of approximately one-third their length from the bottom edge of the truss chord (see Figure A), and drive at an angle of approximately 30° from the face of the chord. A & zas de retiro o fuerzas laterales es más para grados y especies de madera más densos. The greater the penetration into the wood member, the greater the withdrawal and lateral resistance provided by the nail. Longitud de Penetración: Cuanto más grande la penetración en el miembro de madera, el más grande está el retiro y resistencia lateral provisto por el clavo. Figure A Limit the total number of toe-nails to three (including both sides, see Figure B) for full bearing on a 2x4 (i.e., 3-1/2”) top plate and five (including both sides, see Figure C) for full bearing on a 2x6 (i.e., 5-1/2”) top plate. 4. Type of Nail: Section A-A Truss Wall Top Plate Truss Wall Top Plate 3 Nails total 5-½" Box Length – Longitud Deformed shank (i.e., ring- or screw-shank) typically provide greater withdrawal resistance than smooth shank nails. Eltipodellargodeclavotambiéninfluiránlacapacidadderetención. Clavos con largos desformados (ej., largos de anillos o tornillos) típicamente provean más resistencia de retiro que clavos de largos lisos. UPLIFT & LATERAL RESISTANCE CAPACITY OF TOE-NAILED CONNECTIONS USED WITH BOTTOM BEARING APPLICATIONS LA CAPACIDAD DE RESISTENCIA LATERAL Y LEVANTAMIENTO DE CONEXIONES CLAVADOS-OBLICUADAMENTE USADOS CON APLICACIONES SOPORTANTES INFERIORES The dimensions included here are a guide. Use care to avoid splitting of truss lumber. Las dimensiones incluidas aquí son una guía estimada. Tenga cuidado para evitar desintegración de la madera del truss. Diameter – Diámetro Sinker Common Thetypeofnailshankalsowillinfluencenailholdingcapacity. Figure C When using toe-nails to attach the top or bottom chord of a jack truss to the side of a Girder Truss or wood beam, limit the total number of nails to three for 2x4 chords and four for 2x6. Cuando usa clavos-oblicuos para sujetar la cuerda superior o la cuerda inferior de un truss de gato al lado de un Truss de Trevsaño o una viga de madera, limite el número total de clavos a tres para cuerdas de 2x4 y cuatro para cuerdas de 2x6. The larger the diameter of the nail shank the greater the resistance to withdrawal and lateral loads. For this reason, common wire nails provide greater resistance than the same size (i.e., penny-weight) of box or sinker nails. Tipo de Clavo: Cuanto más grande el diámetro del largo de clavo, la más resistencia al retiro y cargas laterales. Para esta razón, clavos alambres comunes proveen más resistencia que los clavos cuadrados o sinker del mismo tamaño (ej., peso-de-penny). 5 Nails total 3-½" Figure B Nailing through metal connector plates is allowed provided the nailing does not damage the metal plate. (See Figure D). Clavando a través de chapas de conexión de metal es permitido si el clavando no hace daño a la chapa de metal. (Vea la Figura D). Wind loads acting on a truss, as well as certain multi-span truss applications supporting gravity loads, can produce uplift reactions at truss bearing locations. The magnitudes of these uplift reactions are typically provided on the Truss Design Drawing (TDD). Cargas de viento que afecta un truss, así como ciertas aplicaciones de trusses de varios-vanos que soportan cargas de gravedad, pueden producir reacciones de levantamiento en las ubicaciones de soportes de truss. Las magnitudes de estas reacciones de levantamiento son típicamente provistas en el Dibujo del Diseño de Truss (TDD). Figure D (4 pages) lots of 50 B8ToeNail 120104 RESUMEN BCSI-B8 BCSI-B8 SUMMARY SHEET 2012 B8 FINAL.indd 1 1/19/2012 1:46:43 PM member non-member PRICE EACH LOT PRICE EACH LOT 1-9 10-19 20-99 100+ $25.00 24.00 23.00 22.00 $42.50 41.00 39.00 37.50 shipping units x qty. An informational sheet (in English/Spanish) for framers that was created to help component manufacturers effectively communicate the JOBSITE PACKAGE's value. It encourages framers to review the package's contents and follow its recommendations. LOTS OF 50 1 WARNING: The handling, storing, installing, restraining and diagonal bracing of structural building components requires specialized training, clearly implemented procedures, and careful planning and communication among the contractor, crane operator and installation crew. Handling and installing components without appropriate training, planning and communication greatly increases the probability of an accident resulting in property damage, serious personal injury and/or death. Prior to component installation, the documents should be examined and disseminated to all appropriate personnel, in addition to proper training and a clear understanding of the installation plan, any applicable fall protection requirements, and the intended restraint and bracing requirements. Trusses with clear spans of 60 feet or greater in length are very dangerous to install and may require complex temporary and permanent bracing. Please consult a Registered Design Professional. Examine the building, the building’s structural framing system, bearing locations and related installation conditions. Begin component installation only after any unsatisfactory conditions have been corrected. Do not cut, modify or repair components. Report any damage before installation. The enclosed documents are offered as minimum guidelines only. Nothing contained in this jobsite package should be construed in any manner as expanding the scope of responsibility of, or imposing any additional liabilities on, the component manufacturer. B9 Girders are trusses specially designed to carry extra loads from framing and equipment. Girder Trusses may consist of a single ply or as many as six plies. The Truss Designer will specify the number of members in a multi-ply girder. Each girder is made up of similar trusses built and fastened together to act as one unit to support the load. Travesaños son trusses que son específicamente diseñados para llevar cargas adicionales de armazón y equipo. Trusses de Travesaños pueden consistir en una sola capa o tanto como seis capas. El Diseñador del Truss especificará el número de miembros en un travesaño de varias-capas. Cada travesaño es hecho de trusses similares construidos y sujetados juntos para funcionar como uno para soportar la carga. Requisitos De Conexión De Capa-a-Capa Ply-To-Ply Connection Requirements ¡AdvErtEnciA! Travesaños de varias-capas no pueden funcionan según el diseño a menos que todas capas son sujetadas juntas apropiadamente. WArning Multi-ply girders cannot perform according to design unless all plies are properly fastened together. check the Truss Design Always Drawing (TDD) for the girder ply-to- The sample TDD in the figure below highlights the nailing schedule for this example three-ply girder. El TDD de muestra en la figura abajo destaca el horario de clavar para este ejemplo de un travesaño de tres-capas. ply connection requirements. They are listed in the fastener schedule and will specify the type, size and spacing of fasteners to be used. NOTE – Cluster nailing may be required at concentrated loads. 8 SAMPLE Good Installation Practices Buenas Prácticas De Instalación 2006 IRC/TPI 1-07 If at all possible, fasten multi-ply girder trusses together prior to erection/installation. Siempre revisa el Dibujo del Diseño de Truss (TDD) para los requisitos de la conexión de travesaño capa-a-capa. Están enumerados en el horario de cierres y especificará el tipo, tamaño y espaciamiento de los cierres que usará. NOTA – Clavando en grupos puede ser requerido en cargas concentradas. Si es posible, sujete los trusses de travesaños de varias capas juntos antes de erección/instalación. RESTRAINT & BRACING CLR 1) Refer to BCSI-B1, BCSI-B2, and BCSI-B3 for handling, installing, restraining and bracing guidlines. 2) All Plates are 20 Ga. unless noted 3) Designed to ANSI/TPI 1 - 2007 WArning All of the plies in a Truss Girder must be fastened together completely in accordance with the requirements specified in the TDD before attaching any supported members or other loads to the girder. ¡AdvErtEnciA! Todas las capas en un Travesaño de Truss tienen que ser completamente sujetadas juntas de acuerdo con los requisitos especificados en el TDD antes de sujetar algunos miembros soportados u otras cargas al travesaño. Spreader bar/stiffback sure that the Girder Truss is laterally Make restrained and braced to ensure lateral stability (2 pages) lots of 50 Asegúrese que el Truss de Travesaño es restringido lateralmente y arriostrado para asegurar la estabilidad lateral y prevenir desviación o rotación imprevisto. and prevent unexpected deflection or rotation. Fastener Guidelines GuÍa De Cierres bolts, screws or other approved fasteners Nails, are typically used for attaching the individual Clavos, pernos, tornillos u otros cierres aprobados son típicamente usados para sujetar las capas individuales de un travesaño de varias-capas juntas depende en la cantidad de la carga y el número de capas. Use el tipo y tamaño correcto de cierre(s) especificado en el TDD. Ubicar y espaciar los cierres de acuerdo con los requisitos especificados en el TDD. plies of a multi-ply girder together depending on the amount of load and number of plies. Use the correct type and size of fastener(s) specified on the TDD. and space fasteners in accordance with the requirements Locate specified on the TDD. Some Truss Manufacturers mark Girder Trusses with supplemental tags, calling further attention to the number of plies and fastening schedule on the TDD. An example of one such truss tag is shown here. THIS IS A MULTI-PLY TRUSS (NOT SINGLE PLY) Fasten trusses together according to truss design drawing, prior to erecting whenever possible. Inspect all connections. Abroche trusses juntos de acuerdo con el dibujo de diseño de truss, antes de erectar cuando sea posible. Inspecte todas las conecciones. (NO DE UNA CAPA) ESTE TRUSS ES DE VARIAS CAPAS 1-9 10-19 20-99 100+ Algunos Fabricantes de Trusses marcan los Trusses de Travesaños con etiquetas suplementarias, llamando más atención al número de capas y el horario de cierre en el TDD. Un ejemplo de una etiqueta de truss es mostrado aquí. MPT 20040801 B4ConstLoad 151202 BCSI-B9 SUMMARY SHEET 2015 B9 Summary Sheet.indd 1 member non-member PRICE EACH LOT PRICE EACH LOT 12/4/2015 2:30:46 PM $14.00 13.50 13.00 12.00 $24.00 23.00 22.00 20.00 shipping units x qty. 10 ¡ADVERTENCIA!: El manejo, almacenamiento, instalación, restricción y arriostre diagonal de componentes estructurales de construcción requieren entrenamiento especializada, procedimientos claramente implementados y planificaron y comunicación clara entre el contratista, operador de grúa, y los obreros de instalación. El manejar e instalar los componentes sin entrenamiento suficiente, planificación y comunicación adecuadas aumenta la probabilidad de un accidente que resulta en dareo a propiedad, herida seria o muerte. Antes de la instalación de componentes, los documentos adjuntos deben ser examinados y difundidos a todo el personal apropiado, además del entrenamiento pertinente y un claro entendimiento del plan de instalación, de todo requisito aplicable de la protección contra la caída y de los requisitos previstos de arriostre y restricción. La instalación de trusses con tramos despejados y más de 60 pies de largo es muy peligrosa y puede requiere el arriostre temporal y permanente complejo. Por favor, consulte a un Profesional de Diseño Registrado. Examine la estructura, el sistema armazón estructural de edificio, ubicaciones de soporte e las condiciones de instalación correspondientes y comenzar con la instalación de los componentes sólo después de haber corregido toda condición insatisfactoria. No corte, modifique ni repare los componentes y informe cualquier daño descubierto antes de proceder a la instalación. LOTS OF 50 Los documentos adjuntos se ofrecen solamente como directrices mínimas. Nada de lo incluido en este paquete debe interpretarse de manera que exceda el alcance de la responsabilidad del fabricante de componentes, ni en forma tal que imponga responsabilidades adicionales sobre éste. $7.50 $18.75 shipping units x qty. 10 1 member PRICE EACH non-member price each $13.00 $32.50 shipping units x qty. 10 To view a non-printing PDF of this document, visit www.sbcindustry.com/jobsitecs. for Design responsibilities see reverse 2013 JOBSITE cover sheet CS5.indd 1 3/18/2013 1:12:34 PM CANADAJOBSITECS-D Jobsite Cover Sheet – English/French JOBSITE PACKAGE IMPORTANT DOCUMENTS ENCLOSED – PLEASE REVIEW PAQUET DE CHANTIER LES DOCUMENTS IMPORTANTS CI-INCLUS – VEUILLEZ ÉTUDIER WARNING: The handling, storing, installing, restraining and diagonal bracing of structural building components requires specialized training, clearly implemented procedures, and careful planning and communication among the contractor, crane operator and installation crew. Handling and installing components without appropriate training, planning and communication greatly increases the probability of an accident resulting in property damage, serious personal injury and/or death. b10postframe-d B10 Summary Sheet - Post Frame Truss Installation, Restraint & Bracing non-member price each The English/Spanish jobsite package cover sheet includes warnings about the handling, storing, installing, restraining and diagonal bracing of structural building components. Portions of the ANSI/TPI 1-2007 design responsibilities are on the back. JOBSITE PACKAGE IMPORTANT DOCUMENTS ENCLOSED PLEASE REVIEW The BCSI-B9 Summary Sheet explains how multiple-ply girder trusses consist of two or more individual trusses that must be attached together to act as a single member. This bilingual (English/ Spanish) document discusses various attachment methods and types of fasteners. It summarizes Section B9 of the BCSI Book. Multi-Ply Girders Travesaños Varias-Capas member PRICE EACH SPANISHJOBSITECS-D Jobsite Cover Sheet – English/Spanish 24 b9girder-d B9 Summary Sheet - Multiple-Ply Girders PLATE HERE P A C K A G E S Grado y Especie de Madera: La resistencia del clavo a fuer- 3. Length of Penetration: 1/3 Nail Length Limite el número total de clavos-oblicuos a tres (incluyendo ambos lados, vea la Figura B) para soporte total en una 2x4 (ej., 3-1/12 pulgadas) chapa de arriba y cinco (incluyendo ambos lados, vea la Figura C) para soporte total en un 2x6 (ej., 5-1/2 pulgadas) chapa de arriba. J O B S I T E Nail resistance to withdrawal and lateral forces is greater for denser grades and species of lumber. A 30° Instalación Apropiada: Empiece con los clavos a una distancia aproximadamente un-tercio de su largo del borde inferior de la cuerda del truss y clavarlos (vea la Figura A), a un ángulo de 30 grados de la cara dela cuerda. INFOFRAMER-D information for Framers Flyer – English/Spanish The BCSI-B8 Summary Sheet discusses how toenailed connections are often used to attach metal plate connected wood trusses to bearing walls, beams and girder trusses to resist uplift and lateral forces. Uplift and lateral resistance capacities for toe-nailed connections are provided, as well as general connection options for when toe-nailing is not enough. This bilingual (English/Spanish) document summarizes Section B8 of the BCSI Book. Using Toe-Nailed Connections to Attach Trusses at Bearing Locations El Uso de Conexiones Clavados-Oblicuamente para Sujetar los Trusses en Ubicaciones de Soporte Wood Truss Council of America & Truss Plate Institute Copyright © 1992-2004 All Rights Reserved B C S I The English/French jobsite package cover sheet includes warnings about the handling, storing, installing, restraining and diagonal bracing of structural building components. Prior to component installation, the documents should be examined and disseminated to all appropriate personnel, in addition to proper training and a clear understanding of the installation plan, any applicable fall protection requirements, and the intended restraint and bracing requirements. Trusses with clear spans 60 feet or greater are very dangerous to install and may require complex temporary and permanent bracing. Please consult a Registered Design Professional. Examine the building, the building’s framing structural system, bearing locations and related installation conditions. Begin component installation only after any unsatisfactory conditions have been corrected. Do not cut, modify or repair components. Report any damage before installation. The enclosed documents are offered as minimum guidelines only. Nothing contained in this jobsite package should be construed in any manner as expanding the scope of responsibility of, or imposing any additional liabilities on, the component manufacturer. AVERTISSEMENT: La manipulation, l’entreposage, l’installation, la contrainte et le contreventement diagonal des composants structuraux nécessitent de la formation spécialisée, des procédures clairement réalisées, et de l’élaboration et de la communication prudente entre l’entrepreneur, le grutier et l’équipe d’installation. La manipulation et l’installation des composants sans la formation, l’élaboration et la communication convenables augmentent considérablement la probabilité d’un accident qui résultera des dégâts matériels, des blessures personnelles graves et/ou de la mort. Avant l’installation des composants, les documents devraient être examinés et disséminés au tout personnel pertinent, en plus de la formation convenable et une compréhension claire du plan de l’installation, toutes les exigences applicables de la protection contre les chutes, et les exigences prévues de la contrainte et du contreventement. Les Fermes avec les portées plus longues que 60” (18 288mm) sont très dangereuses à installer et peuvent exiger du contreventement temporaire complexe et du contreventement permanent complexe. Veuillez consulter un Concepteur Professional Enregistré. Inspectez le bâtiment, son système structural de charpente, les appuis et des conditions d’installation relatives. Commencez l’installation des composants seulement après toutes les conditions peu satisfaisantes ont été corrigées. Ne pas couper, ne pas modifier et ne pas réparer aucun composant. Rapportez tous les dégâts avant l’installation. LOTS OF 50 1 member PRICE EACH non-member price each $13.00 $32.50 shipping units x qty. 20 Les documents ci-inclus sont offerts seulement comme des directives minimums. Rien n’incluait dans ce paquet de chantier devraient être interprété en aucune manière comme agrandir la portée de la responsabilité du fabricant des fermes, ou lui imposer des responsabilités additionnelles. B10 The BCSI-B10 Summary Sheet provides guidelines for the proper handling, installing, restraining and bracing of flat bottom chord MPCW trusses spaced > 2' to 12' on-center in engineered post frame building system applications. This bilingual (English/Spanish) 12-page document summarizes Section B10 of the BCSI Book. Post Frame Truss Installation, Restraint & Bracing Instalación, Restricción y Arriostre de Armazón de Poste COMMENTARY AND RECOMMENDATIONS For trusses spaced greater than 2’-0” on-center and up to 81’-0” in length COMENTARIO Y RECOMMENDACIONES Para los trusses espaciados más de 2 pies en el centro y hasta 81 pies de largo See BCSI-B1 for additional information on truss unloading, jobsite handling, jobsite storage, hoisting and lifting. Heed all warnings and caution notes. Vea BCSI-B1*** para más información sobre como descargar, manejar en la obra, almacenar en la obra, y levantar los trusses. Presta atención a todas las advertencias. *** Warning Trusses with clear spans 60 feet or greater are extremely dangerous to install and require more detailed safety and handling measures than shorter span trusses. Hire a registered design professional to provide a restraint/ bracing plan and to supervise the erection process. ¡advertencia! Trusses de 60 pies o más de largo son muy peligrosos para instalar y requieren las prácticas de seguridad y tratamiento más detalladas que los trusses más cortos de largo. Contrata un profesional registrado de diseño para proveer un plan de restricción/arriostre y para supervisar el proceso de construcción. TRUSS STORAGE – ALMACENAJE DE TRUSSES do not unload trusses on rough terrain or uneven surfaces that could cause damage to the truss. no descargar trusses en terreno escabroso o superficies irregulares que pueden causar daño al truss. Walking on trusses that are lying flat is extremely dangerous and is strictly prohibited. Caminar arriba de trusses que están acostados planos es extremamente peligroso y es estrictamente prohibido. þ 8'-10' 8'-10' be stored horizontally for more than one week, place blocking of sufficient height beneath the stack of trusses on 8' to 10' intervals (or as required) to minimize lateral bending and to lessen moisture gain from the ground. Los trusses pueden ser descargados directamente en el terreno al tiempo de la entrega o almacenados temporalmente en contacto con el terreno después de la entrega. Si los trusses tienen que ser almacenados horizontalmente por más de una semana, ponga bloqueo de la altura suficiente debajo el montón de trusses en intervalos de 8 hasta 10 pies (o como sea requerido) para minimizar el doblado lateral y reducir la cantidad de agua que absorben el terreno. þ Trusses may be unloaded directly on the ground at the time of delivery or stored temporarily in contact with the ground after delivery. If trusses are to Trusses que están almacenados por más de una semana serán protegidos del ambiente en una manera que provee la ventilación adecuada de los trusses. Si unas lonas o otras cubiertas protectivas están utilizadas, los extremos tienen que quedar abiertos para la ventilación. Las cubiertas apretadas no son recomendadas, porque atrapan la humedad. caUtion Exercise care when removing banding and handling trusses to avoid damaging trusses and prevent injury. Wear personal protective equipment for the eyes, feet, hands and head when working with trusses. caUteLa Utilice cuidado al quitar las tiras y al manejar los trusses para evitar daño al trusses y prevenir heridas. Lleve el equipo personal protectivo para los ojos, pies, manos y la cabeza cuando está trabajando con trusses. (12 pages) lots of 50 do not store bundles upright (vertical) unless properly braced to prevent toppling. no guardar los paquetes derechos (verticales) a menos que estén arriostrados apropiadamente para prevenir que se caigan. Trusses stored for more than one week shall be protected from the environment in a manner that provides adequate ventilation of the trusses. If tarpaulins or other protective covers are used, the ends must be left open for ventilation. Tight fitting covers are not recommended, since they trap moisture. 1-9 10-19 20-99 100+ B10PostFrame 150515 BCSI-B10 SUMMARY SHEET 2015 B10 Summary Sheet FINAL.indd 1 memberPRICE non-member EACH LOT PRICE EACH LOT 5/22/2015 11:43:05 AM $66.00 63.00 60.00 57.00 $112.00 107.00 102.00 97.00 shipping units x qty. Structural Building Components Association 608/274-4849 • www.sbcindustry.com Copyright © 2010 FRJobsiteCS 100812 To view a non-printing PDF of this document, visit www.sbcindustry.com/frjobsitecs. Pour regarder un PDF non-imprimable de ce document, visitez www.sbcindustry.com/frjobsitecs. WallPanelJobsiteCS-D Wall Panel Jobsite Cover Sheets JOBSITE PACKAGE IMPORTANT DOCUMENTS ENCLOSED PLEASE REVIEW WARNING: This cover sheet provides warnings specifically about handling, installing, storing and bracing wall panels. Text is in English and Spanish. The handling, storing, installing and temporary bracing of wall panels requires specialized training, clearly implemented procedures, and careful planning and communication among the contractor and installation crew. Handling and installing wall panels without appropriate training, planning and communication greatly increases the probability of an accident resulting in property damage, serious personal injury and/or death. 55 Prior to wall panel installation, the documents should be examined and disseminated to all appropriate personnel, in addition to proper training and a clear understanding of the installation plan, any applicable fall protection requirements, and the intended temporary bracing requirements. Examine the building’s foundation and related installation conditions. Begin wall panel installation only after any unsatisfactory conditions have been corrected. Do not cut, drill, notch or otherwise alter the wall panels beyond the limitations specified in the building code. Report any damage before installation. The enclosed documents are offered as minimum guidelines only. Nothing contained in this jobsite package should be construed in any manner as expanding the scope of responsibility of, or imposing any additional liabilities on, the wall panel manufacturer. ¡ADVERTENCIA!: El manejo, almacenamiento, instalación y arriostre temporal de paneles de pared requieren entrenamiento especializada, procedimientos claramente implementados y la planificación y comunicación clara entre el contratista y los obreros de instalación. El manejar e instalar los paneles de pared sin entrenamiento suficiente, planificación y comunicación adecuadas aumenta mucho la probabilidad de un accidente que resulta en daño a propiedad, herida seria o muerte. Antes de la instalación de los paneles de pared, los documentos adjuntos deben ser examinados y difundidos a todo el personal apropiado, además del entrenamiento pertinente y un claro entendimiento del plan de instalación, de todo requisito aplicable de la protección contra la caída y de los requisitos previstos de arriostre temporal. Examine el cimiento de la estructura y las condiciones de instalación correspondientes. Comenzar con la instalación de los paneles de pared sólo después de haber corregido toda condición insatisfactoria. No corte, perfore, haga muesca ni altere de otro modo los paneles de pared fuera de las limitaciones especificadas en el código de edificio. Informe cualquier daño descubierto antes de proceder a la instalación. b11fall-d CANADAB11-D b11 summary Sheet - Fall Protection & Trusses Los documentos adjuntos se ofrecen solamente como directrices mínimas. Nada de lo incluido en este paquete debe interpretarse de manera que exceda el alcance de la responsabilidad del fabricante de paneles de pared, ni en forma tal que imponga responsabilidades adicionales sobre éste. LOTS OF 50 1 member PRICE EACH non-member price each $13.00 $32.50 shipping units x qty. 20 To view a non-printing PDF of this document, visit www.sbcindustry.com/wallpaneljobsitecs. B11C Fall Protection & Trusses Prévention des chutes et fermes Before you start, contact the Federal, Provincial or Territorial OSH regulatory bodies for information on fall protection and erection/installation of trusses in residential construction. Avant de commencer, communiquez avec les organismes de réglementation fédéraux, provinciaux ou locaux de santé et sécurité au travail pour obtenir des renseignements sur la prévention des chutes et l’érection/l’installation de fermes dans une construction résidentielle. Truss Systems Système de Fermes DANGER Il est dangereux d’utiliser toute partie d’un système de fermes de toit ou de plancher insuffisamment renforcée ou gainée comme point d’ancrage pour tout type de système de prévention des chutes et augmentera le risque de blessures graves ou de mort. DANGER Any part of an inadequately braced or sheathed roof or floor truss system used as an anchorage point for any type of personal fall arrest system is dangerous and will increase the risk of serious injury or death. B11 Fall Protection & Trusses Protección de Caída y Trusses WARNING Roof and floor trussAVERTISSEMENT Les fermes de es that are not properly braced toit et de plancher qui ne sont pas corper BCSI or sheathed are not able rectement renforcées conformément to resist lateral impact loads asau BCSI or gainées ne pourront pas sociated with falls. A falling worker résister aux charges à impact latéral attached to an inadequately associées aux chutes. La chute are d’uncontained in OSHA’s Fall Protecbraced set of trusses could cause Regulations on fall protection and erection/installation of trusses in residential construction travailleur relié à un ensemble de fer- states in part: “Each employee all the previously set trusses tion to Standard, 29 CFR 1926 Subpart M(the Standard). Section 1926.501(b)(13) of the Standard mesabove qui nelower sont levels pas correctement ren- by guardrail systems, scafcollapse in a domino effect. engaged in residential construction activities 6 feet or more shall be protected forcées pourrait causer l’effondrement folding, a safety net system or a personal fall arrest system.” de toutes les fermes précédemment mises en place dans Las regulaciones sobre protecciónune contra caídas levantamiento/instalación de entramados en construcción residencial réaction enychaîne. vienen contenidos en la Regulación de Protección contra Caídas de OSHA, 29 CFR 1926 Subparte M (el Estándar). La sección 1926.501(b)(13) de la regulación establece en parte: “Cada empleado que participe en actividades de construcción residencial a 6 pies o más por encima de niveles inferiores deberán estar protegidos por sistemas de rampas de protección, andamiaje, un sistema de red de seguridad o un sistema de protección personal para detención de caídas.” SBCA has created an alternate fall protection plan template, complete with links throughout the document to the applicable steps to follow in its online step-by-step approach to erecting an initial truss system under OSHA’s fall protection requirements. Visit sbcindustry.com/fp Refer to BCSI-B1C*, BCSI-B2C* and BCSI-B7C* for recommendations on proper bracing of trusses. Sistemas de Entramama Truss Systems The BCSI-B11 Summary Sheet provides guidance to framing crews on how to assess fall hazards while installing trusses on residential construction jobsites. It stresses that trusses are not designed to serve as fall protection anchorage, and highlights additional fall protection requirements under OSHA’s new standards. This bilingual (English/Spanish) document summarizes Section B11 of the BCSI Book. DANGER Any part of an inad¡PELIGRO! Cualquier pieza de un BCSI-B7C* equately braced or sheathed Reportez-vous à BCSI-B1C*, BCSI-B2C* etsistema de entramado de techo o el piso roof or floor truss system used pour obtenir des recommandations sur le renforcement apuntalado o forrado de forma inadecuaapproprié des fermes. as an anchorage point for any da que se utilice como punto de anclaje type of personal fall arrest para cualquier tipo de sistema de protecrenforcées. system is dangerous and will DANGER Ne marchez pas sur des fermes nonción personal para detención de caídas increase the risk of serious es peligroso y aumentará el riesgo de DANGER Ne vous tenez pas sur des surplombs de ferme injury or death. lesiones personales de gravedad o la avant que le revêtement structurel ne soit appliqué sur la muerte. DANGER Do not walk on unbraced trusses. WARNING Roof and floor ferme et les surplombs. ¡ADVERTENCIA! Los entramados de trusses that are not properly techo y piso que no están correctamente DANGER Do not stand on Truss overhangs braced per BCSIuntil or sheathed apuntalados según BCSI o forrados no Structural Sheathing has been applied to the Trusslateral are not able to resist pueden resistir cargas de impacto lateral and overhangs. impact loads associated with asociadas con caídas. Un trabajador que falls. A falling worker attached sufra una caída y que esté acoplado a to an inadequately braced set un conjunto de entramados que no estén of trusses could cause all the apuntalados adecuadamente podría proB11CFall 151106 previously set trusses to colvocar que los entramados fijados previalapse in a domino effect. mente se colapsen con un efecto dominó. BCSI-B11C SUMMARY SHEET • Feuille Sommaire BCSi-B11C Refer to BCSI-B1* and BCSIB2 for recommendations on proper bracing of trusses. 2015 B11C Summary Sheet.indd 1 12/18/2015 12:05:17 PM Refer to BCSI-B1* for recommendations on proper hoisting of trusses. DANGER Do not walk on unbraced trusses. DANGER Do not stand on Truss overhangs until Structural Sheathing has been applied to the Truss and overhangs. Consulte BCSI-B1* sobre recomendaciones para levantar correcto de los entramados. ¡PELIGRO! No camine sobre entramados no apuntalados. ¡PELIGRO! No se pare en el braguero voladizos hasta revestimiento estructural se ha aplicado a la armadura y voladizos. B11Fall 150722 10 BCSI-B11 SUMMARY SHEET 2015 B11 Summary Sheet.indd 1 2016 (4 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $25.00 24.00 23.00 22.00 $42.50 41.00 39.00 37.50 shipping units x qty. 24 (English/ Spanish) 60 (French) WallPanelJobsiteCS-D 110520 JOBSITEBAGS Jobsite Bags Create your own jobsite information packages with these 10x14 inch zippered plastic bags. These roomy, well constructed bags will help keep jobsite documents clean and dry. They are the same bags used with the preassembled JOBSITE PACKAGE Jobsite-D that contains a selection of the BCSI summary sheets. LOTS OF 100 1 member PRICE EACH non-member price each $30.00 $60.00 shipping units x qty. 50 7/24/2015 9:03:11 AM ORDER ONLINE AT sbcindustry.com/pubs JOBSITE-D Jobsite Package in English/Spanish B C S I The JOBSITE PACKAGE is a critical tool in helping component manufacturers to effectively fulfill their duty to educate and warn customers with important installation and safety information. The package comes in an economical, pre-assembled zippered plastic bag quantity member non-member shipping (10"x14") and consists of information minimum 50 PRICE EACH PRICE EACH units x qty. for framers, a cover sheet, 50-99 $5.00 $8.50 TTBHIBCHECK, B1-B4 and B11 – 100-499 4.80 8.15 Fall Protection & Trusses. 500-999 4.50 7.65 3.5 & 7.23 6.97 B3 C TrussDesignDrawingsmayspecifylocationsof permanentlateralrestraintorreinforcementfor individualtrussmembers.RefertotheBCSIB3SummarySheet***formoreinformation. Allotherpermanentbracingdesignisthe responsibilityoftheBuildingDesigner. Lesfermesnesontpasmarquéesenaucunefaçon pour identifier la fréquence ou la location de la contraintelatéraletemporaireetlecontreventement diagonal.Suivezlesrecommandationspour lamanipulation,l’installationetlacontrainte temporaireetlecontreventementdesfermes. Référez-vousàlabrochureBCSI***pourplus d’informationsdétaillées. Truss Clear Spans of 60’ or greater may require complex permanent bracing. Please always consult a Registered Design Professional. Les Dessins d’Atelier des Fermes peuvent spécifier leslocationsdelacontraintepermanentelatérale oulerenforcementpourdesmembruresdes fermesindividuelles.Référez-vousauBCSI-B3*** pourplusd’informations.Toutautredessindu contreventementpermanentestlaresponsabilitédu ConcepteurduBâtiment. B2 WARNING!Theconsequencesofimproperhandling,erect ing,installing,restrainingandbracingcanresultinacollapse ofthestructure,orworse,seriouspersonalinjuryordeath. CAUTION! Bandingandtrussplateshavesharpedges.Wear gloveswhenhandlingandsafetyglasseswhencuttingbanding. ATTENTION! Lesfeuillardsmétalliquesetlesconnecteursdemétalontdesbordstranchants.Portezlesgantslorsdelamanipulationetleslunettesdesécuritéencoupantles feuillardsmétalliques. CAUTION! Avoidlateralbending. ATTENTION! Evitezlecourbement latéral. Toe-in Cable de direction Tagline Cable de sécurité stress-graded lumber, proprietary metal products, andde metal Latérale Temporaire la purlins and straps. Membrure Supérieure Les matériaux de retenue et de contreventement communs incluent les panneaux structuraux de bois, le revêtement de panneaux de gypse, le bois(CLTMS) classé par résistance mécanique, les produits métalliques Upto30' 10'o.c.max. exclusifs, les(Jusqu'à9144mm) pannes et les feuillards métalliques. (3048mmc/cmax.) 30'to45' 8'o.c.max. (9144mmà13716mm) (2438mmc/cmax.) MINIMUM ATTACHMENT REQUIREMENTS FOR LUMBER RESTRAINT/BRACING1,2 LES EXIGENCES MINIMUMS DES ATTACHMENTS POUR LA CONTRAINTE/LE 45'to60' 6'o.c.max. 1,2 CONTREVENTEMENT DU BOIS (13716mmà18288mm) (1829mmc/cmax.) TRUSSES UP TO 60' LES FERMES JUSQU’À 18 288MM Tagline Cable de sécurité Ground bracing not shown for clarity. Pour simplifier, le contreventement de sol n’est pas montré. 60'to80'* 4'o.c.max. Lumber Size Minimum Nail Size (1219mmc/cmax.) Minimum Number of (18288mmà24384mm) Taille de Bois Taille Minimum de Clou Nails per Connection 1 Other attachment requirements may be specified by *Consult a Professional Engineer for trusses longer than 60'. Nombre Minimum de Truss Designer or Building Designer. *Consultez un Concepteur Professionnel Enregistré pourparlesConnexion fermes qui sont2the plus Clous The grade/size and attachment for bracing materials longues que 60' (18 288mm). 60º or less 60º ou moins Toe-in Cable de direction Spreader bar ½ to 2/3 truss length La barre d’écartement est de ½ à 2/3 de la longueur de la ferme Aprrox. ½ truss length Environ ½ de la longueur de la ferme TRUSSES UP TO 30' LES FERMES JUSQU’À 9 144MM Attach 10’ o.c. max. Spreader bar or stiffback Attachez 3 048mm Barre d’écartement ou WARnIng! Spans over 60' require more complex temporary installation restraint/bracing. centre en centre max. CAUTION!Usespecialcareinwindy raidisseur Locate above mid-height Consult a registered design professional. weatherornearpowerlinesandairports. Localisez au-dessus de la mi-hauteur ATTENTION! Soyezprudentaugrandvent 2x4 stress-graded SeeBCSI-B2***for 3" common spiral (0.122"x3") 38mm x 89mmTCTLRoptions. classé clous vrillés ordinaires 3" par la résistance (3mm x 76mm) Référez-vousauBCSI-B2*** mécanique pourdesoptionsdeCLTMS. 3" common wire (0.144"x3") clous ronds ordinaire 3” (3.7mm x 76mm) RefertoBCSI-B3 2x6 stress-graded SummarySheet***forGableEnd 0.131" x3" pneumatic 38mm xFramerestraint/bracing/ 140mm classé clous pneumatique 0.131"x3” par reinforcementinformation. la résistance (3.3mm x 76mm) mécanique such as wood structural panels, gypsum board sheathing, proprietary metal restraint/bracing products, and metal purlins and straps are provided by the Building Designer. 2 Spreader bar 2/3 to ¾ truss length Tagline La barre d’écartement DAngER! Disregarding handling, installing, restraining and bracing safety est de 2/3 à Cable de ¾ de la longueur de la ferme recommendations is the major cause of truss erection/installation accidents. sécurité TRUSSES UP TO AND OVER 60' DAngER! Le manque des recommandations de sécurité pour manipuler, retenir et LES FERMES JUSQU’À ET installer, PLUS QUE 18 288MM contreventer est la cause majeure des accidents de l’érection et de l’installation des fermes. Pourdesrenseignementsàproposde (19mm) (3 810mm) P/50Building Designer P (mm) Le Contreventement Diagonal “X” au Plan de Membrure Supérieure aux 7/8"du Bâtiment. 14.6' 1/4" intervalles spécifiés 1' par le Concepteur (22mm) (4 450mm) (6mm) (305mm) 1" 16.7' 1/2" Chord2'Plane 2. Permanent Bracing for the Bottom (25mm) (5 090mm) (13mm)Le Plan (610mm) Contreventement Permanent Pour De Membrure Inférieure 18.8' 1-1/8" 3/4" 3' (29mm) (5 730mm) (19mm) (914mm) Use rows of continuous lateral restraint with diagonal 1-1/4" 20.8' 4' bracing, gypsum board sheathing or some other1"ceiling (32mm) (6 340mm) (25mm) (1 219mm) material capable of functioning as a diaphragm. Tolerancesfor 1-3/8" 22.9' 1-1/4 5' Utilisez Outof-Plumb. des rangées de retenues latérales continues (35mm) (6 980mm) (32mm) avec (1 524mm) un contreventement diagonal, un revêtement 1-1/2" de panneaux 6' 1-1/2" 25.0' LesTolérances de gypse ou un autre matériau en mesure de(38mm) fonctionner(1 829mm) (38mm) (7 620mm) comme pourHors diaphragme. 29.2' 1-3/4" 1-3/4" 7' d’Aplomb. (45mm) (8 900mm) (45mm) (2 134mm) The TDD provides information on the assumed 2" support for ≥8' 2" ≥33.3' (51mm) (≥10 150mm) the bottom chord. (51mm) (≥2 438mm) Directly attached rigid ceiling Le DCF fournit des renseignements sur le support prévu Le plafond rigide a attaché directement pour la membrure inférieure. DO NOTproceedwithconstructionuntilalllateral by the building designer with a maximum of 10’ (3 m) on-center. La Hauteur Maximum des Piles Installezrestraintandbracingissecurelyandproperlyin la retenue latérale permanente de la membrure inférieurede à l’espacement Matériaux sur lesindiqué Fermes place. sur le DCF et (ou) par le concepteur du bâtiment avec un maximum de 3 m (10 pi) entraxes. Material Height NEprocédezpasaveclaconstructionjusqu’à Le Matériel La Hauteur CLR splice reinforcement cequetouteslescontrainteslatéralesettoutle Gypsum Board Diagonal bracing. Attach to each truss. Renforcement de l’épissure12" CLC contreventementsontsolidementenplace. Le Panneau de Gypse (305mm) Bottom chords tion. Répétez les contrevents Membrures Inférieures N’excédezpasleshauteursmaximumsdespiles. diagonaux pour chaque ≤45˚ typ. Pourplusd’informations,référez-vousauBCSIensemble de 4 fermes. B4.*** ≤10' (3 m) ≤10' (3 m) of proper bottom chord plane restraint & bracing unless special bracing is designed to support the end wall. La ferme du pignon devrait toujours correspondre au profil des fermes adjacentes pour permettre l’installation de la retenue et du contreventement appropriés du plan de membrure inférieure, à moins qu’un contreventement spécial soit conçu pour supporter le mur d’extrémité. Diagonal Brace Contreventement Diagonal Diagonal Braces Contreventements Diagonals ≤45˚ ≤45˚ Group of 2 Trusses Groupe de 2 Fermes Lateral Restraint Contrainte Latérale Structural Sheathing Revêtement Intermédiaire Structural Lateral Restraint Contrainte Latérale groups of trusses (i.e., three or less). Attach the lateral restraint and diagonal brace to each web member they cross. Les retenues latérales et le contreventement diagonal peuvent également être utilisés avec de petits groupes de fermes (p. ex., trois ou moins). Fixez la retenue latérale et le contreventement diagonal à chaque membrure d’âme qu’ils traversent. ALWAYS DIAGONALLY BRACE THE CONTINUOUS LATERAL RESTRAINT! CONTREVENTEZ TOUJOURS EN Trusses DIAGONAL LA RETENUE LATÉRALE CONTINUE! Checklist for Handling and Installing Truss Member B. Individual Web Member Reinforcement CLR Liste de Vérification pour la2x_ Manipulation etdesl’Installation des Fermes Renforcement membrures d’âme individuelles Plywood or OSB Le Contreplaqué ou OSB Asphalt Shingles Les Bardeaux d’Asphalte Concrete Block Les Blocs de Béton Clay Tile Les Tuiles d’ArgileA JOBS TE PACKAGE 2) WEB MEMBER PLANE — LE PLAN D’UNE MEMBRURE D’ÂME a) prevents out-of-plane buckling ofLATÉRALE truss LA CONTRAINTE & LE CONTREVENTEMENT DIAGONAL SONT TRÈS Plan de members, IMPORTANTS Diagonal Bracing Membrure b) helps maintain proper truss spacing, and Web Member Plane Supérieure Web Members Contreventement Diagonal c) resists and transfersMembrures lateral loads from Plan de d’Âmes Membrure wind and seismic forces. Le contreventement permanent est important d’Âme Diagonal La contrainte latérale NE suffit sans contreventement diagonal. LApaS CONTRAINTE & LE CONTREVENTEMENT TEMPORAIRES The gable end frame should always match the profile of the adjacent trusses to permit installation ≤20' ≤6.1m Note: Some chord and web members not shown for clarity. Notez: Pour simplifier, des membrures et des membrures d’âme ne sont pas montrées. Lateral restraint & diagonal bracing can also be used with small CONSTRUCTION LOADING — LES CHARGEMENTS DE CONSTRUCTION Install bottom chord permanent lateral restraint at the spacing indicated on the tDD and/or Maximum Stack Height for Material on Trusses Contreventement Permanent Pour Les Divers Plans D’une Ferme Permanent bracing is important because&it: LATERAL RESTRAINT DIAGONAL BRACING ARE VERY IMPORTANT Top Chord Plane Iftrussesaretobestoredhorizontally, Lateral restraint is NOTTEMPORARY adequate without diagonal bracing. RESTRAINT & BRACING place blocking of sufficient height beneath Group of 3 Trusses Groupe de 3 Fermes Des autres exigences d’attachement peuvent être spécifiées par le Dessinateur de Ferme ou le Concepteur du Bâtiment. La taille et l’attachement pour des matériaux de contreventement comme les panneaux structuraux Contreventement Diagonal. de bois, le revêtement de panneaux de gypse, les Attach to each produits métalliques exclusifs pour la contrainte ou le DOtruss. NOTexceedmaximumstackheights.Referto Repeat diagonal contreventement, et des pannes et des feuillards sont braces BCSI-B4SummarySheet***formoreinformafor each set of 4 trusses. fournis par le concepteur du bâtiment. 1 2 3 AVERTISSEMEnT! Les portées plus de 60’ (18 288mm) exigent l’installation temporaire de la contrainte/ lacontrainte/lecontreventementetle renforcementdesFermesdePignondu Consultez un concepteur professionnel enregistré. Permanent Bracing for the Various Planes of a Truss Bout,référez-vousauBCSI-B3.*** ouprèsdeslignesdetransmissionetdes le contreventement très complexes. aéroports. Spreader bar for truss Barre d’équilibrage pour les fermes Restraint/Bracing MaterialsTop&Chord Fasteners Temporary Matériaux Et Attaches De Retenue Et De Contreventement Lateral Restraint (TCTLR) Spacing Truss Span CommonlyLaused restraint/bracing materials include wood structural panels, gypsum board sheathing, L’Espacement de la Contrainte Portée de la Ferme Vouspouvezendommagerlafermesivousutilisezlefaîte commepointd’attachependantl’érection. HOISTING RECOMMENDATIONS FOR SINGLE TRUSSES LES RECOMMENDATIONS D’ÉRECTION POUR LES FERMES INDIVIDUELLES Spreader bar Barre d’écartement AVERTISSEMENT! Lesconséquencesdelamanipulation, l’érection,l’installation,lacontrainteetlecontreventement incorrectspeuventaboutiràl’effondrementdelastructure, oupire,desblessurespersonnellessérieusesoulamort. Thecontractoris responsibleforproperly receiving,unloadingandstoringthe trussesatthejobsite. L’entrepreneurestresponsablederecevoir, déchargeretentreposercorrectementles fermesauchantier. Usingasinglepick-pointatthepeakcandamage thetruss. 1) TOP CHORD — LA MEMBRURE SUPÉRIEURE Truss Installation & Temporary Restraint/Bracing L’Installation des Fermes & La Contrainte/Le Contreventement Temporaires HANDLING — LA MANIPULATION Holdeachtrussinpositionwiththeerectionequipmentuntiltopchordtemporarylateralrestraint isinstalledandthetrussisfastenedtothebearingpoints. Supportezchaquefermeenplaceavecl’équipementd’érectionjusqu’àl’installationdelacontraintelatéraletemporairedesmembruressupérieuresetquelafermeestattachéeauxpoints d’appui. Gable End Frames and Sloped Bottom Chords Ferme Du Pignon Et Membrures Inférieures En Pente Purlins Examples of Diagonal Bracing with Continuous Restraint Warning Disregarding permanent restraint/bracing is a major cause of truss field performance Fastener size and spacing requirements and Pannes Des Exemples Du Contreventement Diagonal Avec La problems and has been known to lead to roof or floor system collapse. grade for the sheathing, purlins and bracing Permanent Continuous Contrainte Latárale Continue Lateral Restraint are provided in the building code and/or by the aVErTiSSEMEnT! Le fait de négliger la retenue et le contreventement permanents est une Contrainte Latérale Continuous Lateral building designer. cause majeure des problèmes visant la performance des fermes sur le chantier et cela est reconnu Continue Permanente Restraint pour avoir entraîné l’effondrement des systèmes de toit et de plancher. Contrainte Latérale Le code du bâtiment et (ou) le concepteur du RESTRAINT/BRACING FOR ALL PLANES OF TRUSSES Continue INSTALLING — L’INSTALLATION fournissent les exigences relatives CaUTiOn! Trusses with of 60 feet (18.3 m) orPOUR greater,TOUS may require complexDES permaLA CONTRAINTE ETclear LE spans CONTREVENTEMENT LES PLANS FERMES bâtiment Out of Plane—Hors Axe ≈45˚ à la taille des attaches, à l’espacement et au nent bracing. Please always consult a registered design professional. TolerancesforOut-of-Plane. Max. Bow Truss Length classement du revêtement, des pannes et du Out of Plumb Thisrestraint&bracingmethodisforalltrussesexcept3x2and4x2parallelchordtrusses. ≈45˚ MiSE En garDE! Les fermes ayant des portées libres de 18,3 m (60 pi) et plus peuvent exiger un Diagonal Bracing LesTolérancespourHorsAxe. L’arc max. La Longueur de la Ferme Hors d’Aplomb contreventement. Contreventement Cetteméthodedecontrainte&decontreventementestpourtouteslesfermessaufcesfermesen contreventement permanent complexe. Veuillez toujours consulter un concepteur professionnel agréé. 3/4"Plane at intervals specified 12.5'by the Diagonal D/50Diagonal “X”Dbracing (ft.) in the Top Chord membruresparallèles3x2et4x2(64mmx38mmet89mmx38mm). HOISTING OF SINGLE TRUSSES — L’ÉRECTION DES FERMES INDIVIDUELLES ≤10' (3 m) ≤20' (6.1 m) ≤10' 16" (406mm) 2 bundles 2 paquets 8" (203mm) 3-4 tiles high 3 à 4Atuiles d’épaisseur Lateral restraint 2x4x12' Minimum 2' 2x_ Scab block centered over CLR splice. Attach to CLR with minimum 8-3 ½" common spiral (0.152"x3.5") nails each side of splice or as specified by the Building Designer. reinforcement. avec au moins huit 8- clous vrillés (3 m) or greater lapped over DO NOToverloadsmallgroupsorsingletrusses. Minimum de deux éclisses de 61 cm two trusses or CLR splice centrées sur l’épissure. Fixez au CLC NEsurchargezpaslespetitsgroupesoulesfermesindividuelles. ~ This French/English JOBSITE PACKAGE allows component manufacturers to provide important installation and safety information with every jobsite delivery. This pre-assembled package includes key SBCA/TPI products in a zippered plastic bag (10"x14"). Each package includes a cover sheet, CANADATTBHIB Checklist for Handling & Installing quantity member non-member shipping Trusses and Canadian B1-B4, and minimum 50 PRICE EACH PRICE EACH units x qty. B11, all of which have French and 50-99 $5.00 $8.50 English text. The French/English 100-499 4.80 8.15 JOBSITE PACKAGE is an extremely 500-999 4.50 7.65 6 useful tool in helping component 1000-1999 4.25 7.23 manufacturers effectively fulfill their 2000+ 4.10 6.97 duty to educate and warn. BCSI-B3C SUMMARY SHEET - PERMANENT RESTRAINT/BRACING OF CHORDS & WEB MEMBERS LES NOTES GÉNÉRALES GENERAL NOTES Trussesarenotmarkedinanywaytoidentify thefrequencyorlocationoftemporarylateral restraintanddiagonalbracing.Followthe recommendationsforhandling,installingand temporaryrestrainingandbracingoftrusses. RefertotheBCSIbooklet***formoredetailed information. Lateral restraint and diagonal bracing used T-, L-, Scab, I-, U-Reinforcement and proprietary metal reinforcement provide an alternative for resisting web buckling. Le renforcement en T, en L, en lambourde doublée, en I, en U, le renforcement par produits métalliques exclusifs sont des solutions de rechange pour la résistance au flambement. T-Reinforcement Renforcement T PAQUET DE CHANT ER * Example of raked gable end wall (with scissors Gable End Frame) Un exemple du mur de pignon du bout avec un porte-àfaux (avec une Ferme de Pignon du Bout ciseau) CaUTiOn! Using a flat bottom chord gable end frame with adjacent trusses that have sloped bottom chords is prohibited by some building codes as adequate bracing of this condition is difficult and sometimes impossible. Special end wall bracing design considerations are required by the building designer if the gable end frame profile does not match the adjacent trusses. MiSE En garDE! Il est interdit par certains codes du bâtiment d’utiliser une ferme de pignon à membrure inférieure plate avec des fermes adjacentes qui ont des membrures inférieures en pente, car un contreventement adéquat dans cette condition est difficile, voire parfois impossible. Des considérations spéciales de conception du contreventement des murs d’extrémité sont exigées par le concepteur du bâtiment si le profil de la ferme de pignon ne correspond pas aux fermes adjacentes. Permanent Bracing for Special Conditions Contreventement Permanent Pour Des Conditions Spéciales Sway Bracing—Entretoise De Contreventement Sway bracing is installed at the discretion of the building designer to help stabilize the truss system and minimize the lateral movement due to wind and seismic loads. L’ entretoise de contreventement est installé à la discrétion du concepteur du bâtiment pour aider à stabiliser le système de fermes et à minimiser le mouvement latéral causé par les charges du vent et les charges sismiques. Sway bracing installed continuously across the building also serves to distribute gravity loads between trusses of varying stiffness. L’entretoise de contreventement installée de façon continue le long d’un bâtiment sert également à distribuer les charges de gravité entre les fermes de rigidité variable. L-Reinforcement Scab Reinforcement Metal Product Produit Métallique thestackoftrussesat8’to10’oncenter. parce qu’il: ordinaires 3.5” (3.9mm x 89mm) de Renforcement L Renforcement Plan NEVERstackmaterialsnearapeakoratmid-span. Lateral restraint La contrainte latérale 38mm a) prévient le flambement hors plan des chaque côté de l’épissure ou comme bracing to brace the bottom chord plane. Truss Member, typ. Fortrussesstoredformorethanone always diagonally brace for safety! RefertoBCSI-B2Summary il est précisé par le concepteur du x 89mm x 3 658mm ou plus membrures de fermes; Contrainte latérale N’EMPILEz jamaislesmatériauxprèsdufaîteouàlami-portée. Top Chord Temporary Lateral Contreventement Membrure de Ferme, typique La contrainte latérale et le contreventement week,coverbundlestopreventmoisture b) aide à maintenir l’espacement approprié Restraint (TCTLR) chevauchent deux fermes or bâtiment. pour la sécurité, toujours contreventezSheet***formoreinformation. en diagonale! diagonal sont utilisés pour contreventer le plan SECTION A-Anot shown for clarity. Truss bracing diagonal gainbutallowforventilation. des fermes; La Contrainte Latérale Temporaire de CLR splice reinforcement. laceloadsoverasmanytrussesaspossible. Pour simplifier, le contreventement de de membrure Pinférieure. c) résiste aux charges latérales des forces Référez-vousauBCSI-B2***pour la Membrure Supérieure (CLTMS) Web Member Plane Permanent Building Stability Bracing to Transfer RefertoBCSIBooklet***formore Partagezleschargementssurautantdefermesquecesoitpossible. la ferme n’est pas montré. du vent et des forces sismiques et les Useproperriggingandhoistingequipment. plusd’informations. Wind & Seismic Forces 2x4 min. detailedinformationpertainingtohandling Note: Some chord and web members not shown for clarity. transfère. Truss Bottom Chords x 89mm min.) Contreventement Permanent Pour Assurer La Stabilité Du Bâtiment Des Plans Des Utilisezlebonéquipementpourl’érectiondes MAxIMUM SPACIng FOR TOP CHORD TEMPORARY LATERAL RESTRAInT(38mm (TCTLR) andjobsitestorageoftrusses. Pour simplifier, des membrures et des membrures d’âmes ne sont pas montrées. Positionloadsoverloadbearingwalls. Member Membrures Inférieures Bottom Chord Plane Membrures D’Âme Pour Transférer Les Forces Du Vent Et Les Forces Sismiques Locate ground braces for first truss fermes. Trusses require permanent bracing within Plan de Membrure Inférieure Placezleschargementsau-dessusdesmursporteurs. Sidesfermesdoiventêtreentreposé directlyinlinewithallrowsoftop L’ESPACEMEnT MAxIMUM DE LA COnTRAInTE LATÉRALE TEMPORAIRE DE LA MEMBRUREALL SUPÉRIEURE (CLTMS) Diagonal Braces every 10 truss spaces (20' max.) of the following planes: horizontalement,mettezdublocage chordtemporarylateralrestraint(see The web member restraint or reinforcement specified on a TDD is required to resist buckling due to 3. Permanent Bracing for the Web Member Plane Des Contreventements Diagonaux chaque 10 fermes Top chord plane ALTERATIONS — LES MODIFICATIONS d’épaisseur suffisante sous la pile de The graphic at left shows the1.maximum on-center spacing (see at tableinthenextcolumn). DO NOT axial forces caused by the in-plane loads applied to the truss. Additional restraint and bracing within espacées 6 096mm max. Contreventement Permanent Pour Le Plan De Membrure D’Âme 2. Bottom chord plane fermesà8’à10’(2438mmà3048mm) storeon the web member plane may also be required to transfer lateral forces due to wind and/or seismic ≈90° RefertoBCSI-B5SummarySheet.*** left) of TCTLR based on truss3.span from the table in Step 2 on page 2. Localisezlescontreventsdusol Web member permanent bracing collects and transfers buckling restraint forces and/or lateral loads Web member 10'-15' max. Sameplane spacing as bottom chord Lateral Restraint centreencentre. Some chord and web members not shown for clarity. uneven loads applied perpendicular the plane of the trusses. This restraint and bracing is typically speciÉtudiez tous lestorenseignements fournissaient dans le PAQUET DE Pourplusd’informations,référez-vousauBCSIpourlapremièrefermeenligne 3 048mm à 4 572mm max. Le même espacement que la forces. The same bracing can often be used for both functions. Pour simplifier, quelques membrures et membrures d’âmes ne from wind and seismic • Ground bracing not shownLes for clarity. ground. fermes exigent un contreventement permanentdans TOUS les plans suivants: fied by the building designer. Pourlesfermesentreposéesplusqu’une B5.*** directementavectouteslesrangées Contrainte Latérale de la membrure inférieure. Review all de thela information provided intransfère the JOBSITE sont pas montrées. CHANTIER pour assurer la conformité aux recommandations de Le contreventement permanent membrure d’âme récupère et les forces PACKAGE de retenue 1. Le plan de la membrure supérieure semaine,couvrezlespaquetspour La contrainte ou le renforcement des membrures d’âme précisé au DAF est requis pour résister au delacontraintelatéraletemporairedesmembruressupérieures(regardezlatableàlacolonne • apply diagonal bracing or structural sheathing immediately. For spans N’ENTREPOSEz de flambement etto (ou) les charges latérales deswith forces du vent etrecommendations. des forces sismiques. LeProperty même ensure compliance industry DO NOTcut,alter,ordrillanystructuralmember l’industrie. dégâts leschargements blessuresverticaux. personnelles sérieuses 2. Le de la membrure empêcherl’augmentationd’humiditétout 3) plan BOTTOM CHORD —inférieure suivante). flambement sous desLes forces axiales matériels, causées par les Une contrainte ou un passurun of a trusspeut unless specifically permitted by the contreventement souvent être serious utilisé pourbodily les deux fonctions. over 60' applying structural3. sheathing Le plan de la immediately membrure d’âmeis the preferred enbienventilerlespaquets. damage, injury and/or death are possible et/ou la mort peuvent arriver en manipulant en installant les fermes LA MEMBRURE INFÉRIEURE renforcement supplémentaire peut être requis dans le plan de la ou membrure d’âme pour transférer solinégal. TrussDesignDrawing. Brace first truss method. securely les forces latérales causées par le vent ou les charges sismiques exercées when handling Restraint and installing trusses without following the Référez-vousàlabrochureBCSI***pour before erection sans suivre les recommandations présentaient dansperpendiculairement le PAQUET DEau Lateral Restraints 2x4x12' Individual Web Member Permanent & Bracing CAUtION Without-permanent bracing the truss, or a portion of its members, will buckle Some (i.e., chord fail) and web Àmoinsd’aviscontraireindiquesurleDessind’Atelierde plan des fermes. Cette contrainte et ce renforcement sont typiquement précisés par le concepteur of additional trusses. desinformationsplusdétailléesrelatives DO NOTstoreunbracedbundlesupright. or greater lapped overdesign. two trusses. La représentation graphique àatgauche l’espacement centre en recommendations presented in the JOBSITE Retenue EtFerme,necoupezpas,n’altérezpasetnepercezpasde Contreventement Permanents Des Membrures D’Âme PACKAGE. IndividuellesThis is loads far montre less than members not shown CHANTIER. Ceci est vrai particulièrement en travaillant avec les du bâtiment. Contraintes Latérales - 2x4x12' àlamanipulationetl’entreposageau N’ENTREPOSEzpasverticalementles for clarity. Diagonal Brace to roof Diaphragm blocking DO NOTwalkonunbraced membrurestructuraled’uneferme. centre maximum (regardez à gauche) de CLTMS basée sur les permanent, la ferme, ou une partie de sesPour Contreventez la première * MiSE En xgarDE un contreventement memparticularly true when working with trusses 60’ and greater in length. (38mm 89mm x 3 Sans 658mm) fermes qui font 60'Contreventement (18 288mm) ou plus. chantierdesfermes. simplifier, trusses. paquetsnon-contreventés. Diagonal au blocage du Diaphragme de toit Check the TDD to determine which web members (if any) solidement avant ou plus chevauchent 2 fermes. One restraint required on flambera indiquées portées des ferme fermes de la tablebrures, d’Étape 2 à (c’est-à-dire la page 2.fera défaut) à des charges grandement inférieures à cellesquelques membrures l’érection des fermes each of these webs. Note: require restraintTrussesthathavebeenoverloadedduringconstructo resist buckling. NE marchezpassurdes dans la conception. HOISTING RECOMMENDATIONS FOR TRUSS BUNDLES Gable End et membrures CLR can be installed on when tionoralteredwithouttheTrussManufacturer’spriorapprovalmayrendertheTruss chords additionnelles. Property damage, serious bodily injury and/or death are possible Les dégâts matériels, les blessures personnelles sérieuses et/ou la mort fermesquinesontpas • Pour simplifier, le contreventementBottom de sol n’est pas montré. Frame d’âmes ne sont pas Vérifiez le DCF pour déterminer quelles membrures d’âme LES RECOMMANDATIONS DE LEVAGE POUR LES PAQUETS DE FERMES either side of Member. Membrures Manufacturer’slimitedwarrantynullandvoid. de manipulées, installées, retenues équilibrées. montrées. trusses areuneimproperly handled, and/or peuvent arriver quand des fermesFerme sont (si applicable) nécessitent retenue pour résister au installed, restrained inférieures Une contrainte est braced. DON’Toverloadthecrane. • appliquez immédiatement le contreventement diagonal le Chord Plane Lesfermesquiontétésurchargéespendantlaconstructionouquiontétéaltéréessans Roof 1. Permanent Bracing for theouTop Pignon du nécessitée sur chaque flambement.Installation of trusses can be dangerous, particularly long span trusses. et/ou contreventées incorrectement. être NEsurchargezpaslacrue. Diaphragm l’approbationprécédenteduManufacturierdeFermepeuventrendrelagarantielimitéeduManuBout L’installation des fermes peut Contreventement de ces âmes. Note: CLR revêtement intermédiaire structurale. pour les Permanent portées plus Pour de 60’Le Plan De Membrure Supérieure Blocking Restrain facturierdeFermenuletnonavenu. andUse bracethe with:following checklist when handling and erecting can be installed on either trusses. dangereuse, en particulier pour les fermes de longue portée. Utilisez la NEVERusebandingalonetoliftabundle. side of Member. Blocage du (18 288mm), la méthode préférée est d’installer immédiatement du STEPS TO SETTING TRUSSES A. continuous lateral restraint & diagonal bracing, or Horizontal LStructural Sheathing on Top Chord Plane Use plywood, oriented strand board (OSB), or Donotliftagroupofindividuallybandedbundles. Diaphragme liste de vérification suivante Reinforcement pendant la manipulation et l’érection des B. *** individualr member web reinforcement. Revêtement Intermédiaire le Plan de Diagonal Braces Structural every 10sur truss spaces revêtement intermédiaire structural. the trusses atfor the time of delivery and after installation wood or metal structural purlins that are properly LES ÉTAPES À SUIVRE POUR PLACER LES FERMES N’UTILISEzjamaislesfeuillardsmétalliquestousseulspourleverun Contact the Inspect Component Manufacturer more information or consult a Registered de Toit Membrure Supérieure Renforcement L (20' max.) fermes. Retenue et contreventement à l’aide: Note: Top Chord braced. Attach to each truss. paquet.Nelevezpasungroupedepaquetsattachésindividuellement. Design Professional for assistance. for: Horizontal Des Contreventements Diagonaux chaque 10 1)Installgroundbracing. sheathing not shown A. d’une retenue latérale continue et d’un contreventement Utilisez du10'-15' contreplaqué, des panneaux OSB ou fermes espacées 6 096mm max. *** max. Inspecter les fermes au moment de la livraison et après l’installation Asingleliftpointmaybeusedforbundleswithtrussesupto45’.Twoliftpointsmaybeusedfor Set first truss andERECTIOn/InSTALLATIOn attach securely to ground bracing. Contactez le(1) Fabricant de Fermes pour d’informations ou consultez un Concepteur for clarity. r diagonal; ou CHECk THESE ITEMS BEFORE 2)STARTIng AnD CORRECT AS nEEDED Conformance with theplus truss design drawings des pannes structurales de bois (3 048mm à 4 572mm max.)ou de métal corNotez: Pour simplifier, le revêtement intermédiaire de bundleswithtrussesupto60’.Useatleast3liftpointsforbundleswithtrussesgreaterthan60’. 3)Setnext4trusseswithshortmembertemporarylateralrestraint(seeadjacent). B. d’un renforcement Enregistré des membrures individuelles. Professionnel pourd’âme de l’assistance. pour: rectement contreventés. Fixez à chaque ferme. Bottom Chord Lateral Restraint Membrure Supérieure n’est pas montré. VÉRIFIEZ CES CHOSES AVAnT DE4)Installtopchorddiagonalbracing(seeadjacent). COMMEnCER L’ÉRECTIOn/L’InSTALLATIOn ET FAÎTES DES CORRECTIOnS COMME nÉCESSAIRE (2)Dislodged/missing connector plates Unseulpointd’attachepeutêtreutilisépourlespaquetsavecdesfermesjusqu’à45’(13716mm). Contrainte Latérale de la RESTRAINT & BRACING FOR 3x2 AND 4x2 PARALLEL CHORD TRUSSES Toviewanon-printingPDFofthisdocument,visitwww.sbcindustry.com/frb1. Deuxpointsd’attachespeuventêtreutilisépourlespaquetsavecdesfermesjusqu’à60’(18288mm). 5) Install web member plane diagonal bracing to stabilize the first five trusses (see adjacent). (3)Cracked, dislodged broken members (1)La conformation avec les dessins d’atelier des fermes A. Continuous Lateral Restraint (CLR) &orDiagonal Bracing Membrure Inférieure TheLA Truss Design Drawing provides inforCONTRAINTE & LE(TDD) CONTREVENTEMENT POUR LES FERMES À MEMBRURES Utilisezaumoinsde3pointsd’attachespourlespaquetsavecdesfermespluslonguesque60’(18288mm). PourregarderunPDFnon-imprimabledecedocument,visitezwww.sbcindustry.com/frb1. Building dimensions match the construction documents. Trusses are the correct dimension. Retenue Latérale Continue (RLC) Et that Contreventement Diagonal 6)Installbottomchordtemporarylateralrestraintanddiagonalbracing(seeadjacent). PARALLÈLES 3x2 (64MM 38MM) 4x2 (89MM x 38MM). (4)Any other damage may impair the structural (2)Des feuillards métalliques déplacés manquants mation on the assumed supportxfor the topET chord. Gable end/wall permanentou Diagonal Bracing. Locate in line with Bottom WARNING!Donotoverloadsupportingstructurewithtrussbundle. 7)Repeatprocessongroupsoffourtrussesuntilalltrussesareset. Les dimensions du bâtiment égalent celles dans les documents de construction. Repeat Diagonal Bracing Les fermes sont lesLe dimensions correctes. Chord permanent CLR or as specified by the Building Designer. NOTE:Themethods,proceduresandrecommendationssetforthhereindocumentareintendedtoensurethattrussesandcomponentsare Diagonal Bracing dessin de conception de ferme (DCF) of shown the trusses (3)Des membrures fêlées, déplacées ou manquantes Attach each row of CLR atintegrity the locations on the TDD. 10' or 15'* fournit every 15 truss spaces (30') AVERTISSEMENT!Nesurchargezpaslastructuresupportanteavecunpaquetdefermes. handled,erectedandbracedSAFELY.Theserecommendationsarebaseduponthecollectiveexperienceofpersonnelinvolvedwithtrussand Le Contreventement Diagonal permanent du pignon du bout/mur. Contreventement Diagonal 1)Installezlecontreventementdesol. (3at 048mm des renseignements sur leand support prévu pour la Tops of bearing supports are flat, level the ou correct component and installation, and are as a GUIDE for use by qualified Building Designers and Contractors. Répétez le Contreventement Referto Bearing supports (e.g., walls, columns, headers, beams, etc.) are accurately Placez en ligne avec diminuer la CLC permanente de la Membrure Inférieure ou Fixez la RLCdesign, aux manufacture emplacements indiqués surpresented le DCF.onlyDesigner’s (4) Tous autres dégâts qui peuvent l’intégrité structurale These recommendations are neither intended to supersede the Building design specifications nor repairs do they preclude the needed. use of other 4 572mm*) 2)Placezlapremièrefermeetattachez-lasolidementaucontreventementdesol. Notify your component manufacturer if truss are Placebundlesinstableposition. Diagonal par groupe de 15 BCSI-B7Summary membrure supérieure. comme est spécifié par le Concepteur du Bâtiment. elevation. equivalentmethods.WTCAandTPIexpresslydisclaimanyresponsibilityfordamagesarisingfromtheuse,application,orrelianceonthe and securely in des fermes fermes espacées 9 144mm Mettezlespaquetsenpositionsolide. Sheet***formoreinfor3)Placezlesquatrefermessuivantesaveclacontraintelatéraletemporairedelamembrure recommendationsandinformationcontainedherein. damage to the45° trusses is discovered Install the diagonalAfter bracinginstallation, at an angle of if less-than-or-equal-to to the CLR and position sothat that could Some truss designers provide general design tables and details to assist the building designer in Les d’appui sont plats et courte(regardezadjacent). sommets des supportsmation. NOTEZ:Lesméthodesetlesprocéduresquisontdétailléesci-inclusdanscedocumentsontcenséesd’assurerquetouteslesfermesetles it crosses the web weaken in close proximity the CLR. Attachbrace the diagonal brace as the closetrusses to the top to andprevent determiningAvertir INSTALLATION OF SINGLE TRUSSES BY HAND them,totemporarily or support votre fabricant delateral fermes sidue des des forces fermes the bracing required to transfer loads to réparations wind and/or seismic fromsont the composantesstructuralessontmanipulées,érigéesetcontreventéesSANSDANGER.Cesrecommandationssontbaséessurl’expérience à l’élévation correcte. 4)Installezlecontreventementdiagonaldelamembruresupérieure(regardezadjacent). bottom chords as possible and to each web it crosses. Repeat every 20’ (6.1 m) or less. Pourplusd’informations, collectivedupersonnelquiparticipeaudessindesfermesetdescomposantes,àlafabricationetàl’installation.Cependant,ces L’INSTALLATION DES FERMES INDIVIDUELLES À LA MAIN into the roof Si, and/or ceiling diaphragm. des dégâts qui peuvent affaiblir les further and make suredesthe areaduremains clear plumbing, gable end frame nécessaires. après l’installation, 5)Installezlecontreventementdiagonalduplandelamembrurediagonalepourstabiliserles recommandations sont présentéesdamage seulement comme un GUIDE pour l’usage Concepteurs Bâtiment qualifiés ou desof Entrepreneurs référez-vousauBCSIInstallez le contreventement diagonal à un angle de 45º ou moins par rapport à la RLC et le Jobsite is clean and neat, and free of obstructions. concepteurs de fermes fournissent des tableaux de conception généraux dessupportez détails qualifiés. L’intention n’est pas que ces recommandations remplacent les spécifications de dessin du Concepteur du Bâtiment, ni qu’elles premièrescinqfermes(regardezadjacent). B7.*** electrical, runs, untillethe field repairs have been Certains fermes sont trouvés, les contreventez temporairement ouetles positionner de sorte qu’il traversemechanical l’âme à proximité de laetc., RLC. Fixez contreventement diagonal n’empêchentl’usaged’autresméthodeséquivalentes.WTCAetTPInientexpressémentn’importequelleresponsabilitépourlesdégâtsqui Trusses30'orless, pour assister le concepteur du bâtiment à déterminer le contreventement requis pour transférer les Le chantier est propre, organisé et sans obstructions. 6)Installezlacontraintelatéraletemporairedelamembrureinférieureetlecontreventement Trusses20'or résultentdel’usage,del’application,oudeladépendancesurlesrecommandationsetlesinformationssiinclus. aussi près que possible des membrures supérieures et inférieures et de chaque âme qu’il croise. supportatquarter properly completed. pour causées éviter des dégâts le champ reste Apply Diagonal Brace to vertical webs at end of charges latérales par les forces à dunouveau vent et (ou)et lespour forcesassurer sismiquesque provenant de la ferme diagonal(regardezadjacent). less,supportat Répétez à tous les 6 m (20 pi) ou moins. cantilever and at bearing locations. points. . du pignon jusqu’au diaphragmede de la toit plomberie, et (ou) de plafond sans obstacles électrique ou mécanique, etc., jusqu’à 7)Répétezlaprocédureengroupesdequatrefermesjusqu’àcequetouteslesfermessont peak. Ground bracing procedure for first truss is based onauxsite All Lateral Restraints Appliquez un Contreventement Diagonal DO NOT cut, drill, relocate, add or remove any truss member or Lesfermesde30’ installées. membrures verticales à l’extrémité du porte-àce que les réparations au chantier aient achevé correctement. Lesfermesde20’ lapped at least two trusses. and building configuration. metal connector plate until you have received instructions from your (9144mm)oumoins, faux et aux appuis. TRUSS PLATE INSTITUTE (6096mm)ou supportezauxquarts La procédure du contreventement de sol pour la premièreToutes les Contraintes Latérales chevauchent au moins 2 fermes. Trusses up to 30' Trusses up to 20' 6300EnterpriseLane•Madison,WI53719 218NorthLeeStreet,Suite312•Alexandria,VA22314 truss manufacturer. NE PAS couper, percer, déplacer, ajouter ou enlever aucune *Top chord Temporary Lateral Restraint spacing shall be 10' o.c. max. for 3x2 chords and 15' o.c. for 4x2 chords. moins,supportezRefertoBCSI-B2SummarySheet***formoreinformation. Les fermes jusqu’à Les fermes jusqu’à delalongueur. 608/274-4849•www.sbcindustry.com 703/683-1010•www.tpinst.org ferme est basée sur les configurations du bâtiment et dudes membrures supérieures doit être 10' (3 048mm) c/c max. *L’espacement de la Contrainte Latérale Temporaire lesparlefaîte. membrure de ferme ou aucun feuillard métallique jusqu’à vous aurez 9 144mm 6 096mm Pourplusd’informations,référez-vousauBCSI-B2.*** r Protect trusses from weather, corrosion, lateral bending, damage pour les membrures 3x2 (64mm x 38mm) et 15' (4 572mm) c/c pour les membrures 4x2 (89mm x 38mm). Interior FRB1WARN11x17 080728 chantier. Bottom Chord Plane Plan de membrure inférieure Permanent Restraint/Bracing for the Top Chord in a Piggyback Assembly Retenue Et Contreventement Permanents Pour La Membrure Supérieure Dans Un Assemblage De Fermes Chapeaux Repeat diagonal bracing (red) at 10’ intervals, or as specified. Répétez le contreventement diagonal Provide restraint and bracing by: • using rows of minimum 4x2 stress-graded (rouge) aux intervalles de 10 pi (3 m), lumber CLR and diagonal bracing, or ou comme spécifié. • connecting the CLR into the roof diaphragm,or • adding structural sheathing or bracing frames, or • some other equivalent means. Installez la retenue et le contreventement en : • utilisant des rangées de RLC et un contreventement diagonal de bois classé par résistance mécanique d’au moins 4x2; ou • fixant la RLC au diaphragme du toit; ou • ajoutant un revêtement structural ou des ≤45˚ typ. fermes de contreventement; ou • utilisant un autre moyen équivalent. CLR (green) at ≤ the spacing specified on the truss design drawing CLC (vert) espacée comme spécifié dans le dessin d’atelier de ferme Refer to the TDD for the maximum assumed spacing between rows of lateral restraint (e.g. purlins) attached to the top chord of the supporting truss. Reportez-vous au DAF pour connaître l’espacement maximal supposé entre les rangées de contrainte latérale (par ex., les pannes) fixées à la membrure supérieure de la ferme de support. Cap Trusses Fermes Chapeaux The TDD provides the assumed thickness of the restraint and minimum connection requirements between the cap and the supporting truss or restraint. Le DCF fournit l’épaisseur prévue de la retenue et les exigences minimales de raccordement entre la ferme chapeau et la ferme portante ou la retenue. If diagonal bracing is used to restrain the CLR(s), repeat at 10’ (3 m) intervals, or as specified in the construction documents. Si un contreventement diagonal est utilisé pour retenir la (les) RLC, répétez à des intervalles de 3 m (10 pi) ou comme le précisent les documents de construction. CLR required only if Bracing Frame or Structural Sheathing is installed intermittently Des CLC sont requis justement si le Cadre de Contreventement ou le Revêtement Intermédiaire Structural est installé par intervalles Bracing Frame or Structural Sheathing Le Cadre de Contreventement ou le Revêtement Intermédiaire Structural Supporting Trusses Fermes Soutenues To view a non-printing PDF of this document, visit sbcindustry.com/b3c. Pour consulter un format PDF nonimprimable de ce document, visitez sbcindustry.com/b3c. Structural Building Components Association 6300 Enterprise Lane • Madison, WI 53719 608-274-4849 • sbcindustry.com truss Plate Institute of Canada c/o MiTek Canada 100 Industrial Rd • Bradford, ON L3Z 3G7 905-952-2900 • tpic.ca truss Plate Institute 218 N. Lee St., Ste. 312 Alexandria, VA 22314 703-683-1010 • tpinst.org Ce document résume les renseignements fournis dans l’article B3C de l’édition2014 de Building Component Safety Information BCSI CANADA – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. Droit d’auteur © 2014 Structural Building Components Association, Truss Plate Institute et Truss Plate Institute of Canada. Tous droits réservés.Ce guide et toute partie de ce dernier ne peuvent pas être reproduits sous aucune forme sans la permission écrite des éditeurs. Imprimé aux États-Unis d’Amérique. CANADAJobsite-D Jobsite Package in English/French This document summarizes the information provided in Section B3C of the 2014 Edition of Building Component Safety Information BCSI CANADA - Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. Copyright © 2014 Structural Building Components Association, Truss Plate Institute and Truss Plate Institute of Canada. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America. 4.25 4.10 ThisdocumentsummarizestheinformationprovidedinSectionB1ofthe2006EditionofBuildingComponentSafetyInformationBCSI—GuidetoGoodPracticeforHandling,Installing,Restraining&BracingofMetalPlateConnectedWoodTrusses.Copyright©2004-2007WTCA—Representingthe StructuralBuildingComponentsIndustryandTrussPlateInstitute.AllRightsReserved.Thisguideoranypartthereofmaynotbereproducedinanyformwithoutthewrittenpermissionofthepublishers.PrintedintheUnitedStatesofAmerica. Cedocumentrésumelesinformationsafournidansl’articleB1del’Édition2006deBuildingComponentSafetyInformationBCSI—GuidetoGoodPracticeforHandling,Installing,Restraining&BracingofMetalPlateConnectedWoodTrusses.Copyright©2004-2007WTCA—RepresentingtheStructural BuildingComponentsIndustryetTrussPlateInstitute.TouslesDroitsRéservés.Ceguideoun’importequellepartiedeluinepourraitpasêtrereproduitenn’importequelleformesanspermissionécritedeséditeurs.ImpriméauxEtats-Unisd’Amérique. 1000-1999 2000+ B3CPERM151111 RETENUE ET CONTREVENTEMENT PERMANENTS DES MEMBRURES ET DES MEMBRURES D’ÂME Les portées de 18,3 m (60 pi) et plus peuvent exiger un contreventement permanent complexe. Veuillez toujours consulter un ingénieur professionnel. AVERTISSEMENT! L’intérieur and deterioration when stored at the jobsite. When trusses are stored at the site, use blocking, stringers, pallets, platforms or other means of support to keep the trusses off of the ground or in a braced upright un Concepteur Professionnel Enregistré. position to avoid damage. If ground level is too far GUIDE POUR LA MANIPULATION, L’INSTALLATION, LA CONTRAINTE ET LE CONTREVENTEMENT DES FERMES from truss for exterior Les portées plus longues que 60’ (18 288mm) peuvent exiger un contreventementground permanent bracing, use complexe. Veuillez toujours consulter interior ground bracing. Si le niveau du sol est trop loin de la ferme pour utiliser le contreventement de sol extérieur, utilisez le contreventement de sol intérieur. Exterior L’extérieur FRB2Temp 080722 BCSI-B2 SUMMARY SHEET r Carefully review the truss design drawings, the truss placement diagram (if/when provided by contract) and all JOBSITE PACKAGE documents prior to handling and installing trusses. r Examine the building, the building’s structural framing system, bearing locations and related installation conditions. Begin installing trusses only after any unsatisfactory conditions have been corrected. reçu des instructions de votre fabricant de fermes. r Protéger les fermes du temps, de la corrosion, du courbement latéral, des dégâts et de la détérioration pendant l’entreposage au chantier. Quand les fermes sont entreposées au chantier,il faut utiliser du blocage, des blocs de bois, des palettes, des plates-formes ou quelque autre moyen de support pour tenir les fermes du sol ou en position verticale et contreventée pour éviter les dégâts. r Étudier avec soin les dessins d’atelier des fermes, le diagramme de placements des fermes (si ou quand il est fourni par le contrat) et tous les documents du PAQUET DE CHANTIER avant de manipuler et d’installer les fermes. r Inspecter le bâtiment, son système de charpente structurale, Copyright © 2008 WTCA – Representing the Structural Building Components Industry All Rights Reserved. FRTTBHIBCHECK-080716 BCSI-B2 J O B S I T E P A C K A G E S floortrussJOBSITE-D Floor Truss Jobsite Package The Floor Truss Jobsite Package lets component manufacturers provide their customers with important installation and safety information with every jobsite delivery. This economical, pre-assembled package consists of three key SBCA products in a zippered plastic bag quantity member non-member shipping (10"x14"). Each package contains minimum 50 PRICE EACH PRICE EACH units x qty. a cover sheet, TTBHIBCHECK, B7 50-99 $2.60 $4.40 on handling, installing and bracing 100-499 2.50 4.25 3x2 and 4x2 parallel chord trusses 500-999 2.40 4.10 3 (11"x17" size), and B11 – Fall 1000-1999 2.30 3.90 Proctection & Trusses. 2000+ 2.20 3.75 Longspanjobsite-d Long Span Jobsite Package The Long Span JOBSITE PACKAGE is a critical tool in helping component manufacturers to effectively fulfill their duty to educate and warn customers who will be installing long span trusses (which are 60' or more in length). Installing such trusses can be dangerous, and those involved need to be aware of the extra care required. quantity member non-member shipping In addition to the contents of minimum 25 PRICE EACH PRICE EACH units x qty. the JOBSITE PACKAGE, the 25-99 $6.30 $10.70 Long Span JOBSITE PACKAGE 100-499 6.00 10.20 also includes TTB Long Span 500-999 5.70 9.75 6 Truss Installation and B10. All 1000-1999 5.45 9.27 documents include English and 2000+ 5.30 9.00 Spanish text. WallPanelJobsite-D Wall Panel Jobsite Package The Wall Panel JOBSITE PACKAGE allows component manufacturers to provide their customers with important installation and safety information with every jobsite delivery. This economical, pre-assembled package consists of a cover sheet, CTB – Wall Panel and quantity member non-member shipping Hoisting Strap Inspection and Use minimum 50 PRICE EACH PRICE EACH units x qty. Requirements, TTB – Building with 50-99 $3.50 $5.95 Wall Panels, Guide for Handling, 100-499 3.40 5.78 Installing & Temporary Bracing of 500-999 3.25 5.53 3 Wall Panels (11"x17" size), and B11 1000-1999 3.10 5.27 – Fall Protection & Trusses. 2000+ 3.00 5.10 2016 ORDER ONLINE AT sbcindustry.com/pubs 11 T T B CTBWALLSTRAP-D TTBdrawing-d Wall Panel and Hoisting Strap Inspection and Use Requirements How to Read a Truss Design Drawing This document provides important inspection and hoisting guidelines for lifting with these straps and is intended as a supplement to the information found in the SBCA document WallPanel11x17-P, Guide for Handling, Installing & Temporary Bracing of Wall Panels. IN BUILDING IMPORTANT SAFETY INFORMATION Wall Panel and Hoisting Strap Inspection and Use Requirements Warning! Failure to follow these hoisting strap inspection and use guidelines while handling and hoisting wall panels at a jobsite could greatly increase the probability of property damage, personal injury and/or death. ¡AdvertenciA! El incumplimiento de seguir estas pautas del uso y de la inspección de correas de levantamiento durante el manejo y levantamiento de paneles de pared en la obra puede aumentar mucho la probabilidad de daño a la propiedad, herida personal y/o la muerte. T R U S S T E C H N O L O G Y SieMPre inSPecciOne LAS cOrreAS de LevAntAMientO Y LOS PAneLeS de PAred AnteS deL USO Strongback (lifting beam) ≤60˚ Inspeccione las correas de levantamiento y OR nO utilice las correas si descubre alguna de las siguientes cosas: – Hilos rotos o desgastados en las pautas de puntada. – El daño visible o fallo del accesorio de las correas de levantamiento al panel de pared. – Cualquier otro daño que causa que duda la fuerza de las correas de levantamiento. AlWAYS INSPEcT HOISTINg STRAPS ANd WAll PANElS bEFORE USE Inspect the hoisting straps and dO NOT use straps if any of the following are discovered: – Broken or worn threads in the stitch patterns. – Visible damage or failure of the attachment of the hoisting straps to the wall panel. – Any other damage that causes doubt as to the strength of the hoisting straps. Inspect the wall panels at the time of delivery and after installation for: – Conformance with the Wall Panel Drawings and Placement Diagram. – Broken, dislodged or damaged members, such as studs, plates, sheathing, etc. Inspeccione los paneles de pared en aquel momento de entrega y después de la instalación para: – La conformación con los Dibujos y el Diagrama de Instalación de los paneles de pared. (2 pages) lots of 50 – Miembros rotos, sacados o dañados, tales como montantes, chapas, recubrimiento intermedio, etc. – Cualquier otro daño que afecte la integridad estructural de los paneles de pared. Notifique a su fabricante de paneles de pared inmediatamente si modificaciones son requeridas. member non-member PRICE EACH LOT PRICE EACH LOT shipping units x qty. Revise con cuidado los Dibujos y el Diagrama de Instalación de los Paneles de Pared y todos los PAQUETES DE OBRA antes de almacenar, manejar y instalar los paneles de pared. 1-9 10-19 20-99 100+ – Any other damage that impairs the structural integrity of the wall panels Notify your wall panel manufacturer immediately if modifications are required. Carefully review the Wall Panel Drawings and Placement Diagram and all JOBSITE PACKAGE™ documents prior to storing, handling and installing wall panels. $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 10 (4 pages) lots of 50 1-9 10-19 20-99 100+ CTBDRYWALL-D Drywall Cracking & Crowning (DCC) Issues Drywall cracking and crowning (i.e., ridging) occurs mainly in dry regions of the country that occasionally experience periods of high humidity. This document explains the mechanism by which DCC occurs, how seasonal lumber movement is not the culprit, and how correct gypsum board installation practices prevent the problem. IN BUILDING Drywall Cracking and Crowning (DCC) Problems in Arid Environments Cracks in drywall can occur for a variety of reasons including ground settlement, building movement, outof-level bearing conditions, deflection of supporting members and partition separation (refer to the TTB Partition Separation for more information on this). One particular type of drywall cracking and crowning (DCC) occurs when gypsum board is forced together and pulled apart during alternating periods of humid and dry conditions.1 Seasonal extremes in humidity occur primarily in the arid states of Arizona, Nevada, Colorado, Texas and California. These areas have reported higher incidences of DCC in finished structures. Similar cases of DCC have also been reported in the arid regions of Australia and New Zealand. Based on research SBCA has performed, we have observed: Lumber and drywall expand and contract with changes in humidity. However, calculations show lumber shrinkage/expansion caused by seasonal changes in humidity is tiny and insufficient to cause DCC in standard construction. For example, in Las Vegas the equilibrium moisture content (EMC) of wood varies from 8.5% in January to 4.0% in June.2 Under these conditions, the amount of shrinkage between two wood fasteners spaced 12 inches apart would be 0.00325 inches, the thickness of a piece of paper.3 Drywall crowning at the ceiling Drywall cracking at the ceiling (2 pages) lots of 50 Lumber moisture content in finished structures is roughly 8% in arid parts of the country compared to 12% in the rest of the country. A good construction practice is to allow framing to reach an EMC of 19% or less before finishing the interior. Use a moisture meter to measure EMC if necessary. The occurrence of DCC is unpredictable in nature, but the following recommendations will help avoid it. TTBDrywall 120104 2012 CTB Drywall.indd 1 member non-member PRICE EACH LOT PRICE EACH LOT 1-9 10-19 20-99 100+ DCC rarely exists in commercial projects that have a design professional involved, regardless of the structural framing – wood, steel or concrete. Copyright © 2012 SBCA – Structural Building Components Association. All rights Reserved. 1/24/2012 10:04:53 AM $14.00 13.50 13.00 12.00 shipping units x qty. $35.00 33.75 32.50 30.00 Approved February 2008 ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction is the industry’s consensus standard and is referenced by the IBC and IRC. The following text is a compilation of the requirements provided in ANSI/TPI 1-2007, Chapter 2, with permission from the publisher, the Truss Plate Institute (TPI), www.tpinst.org. The requirements are specifically categorized into two distinct areas – when the legal requirements mandate a Registered Design Professional (RDP) is used and when they do not. Terms that are capitalized are in ANSI/TPI 1 and in BCSI, Guide to Good Practice for Handling, Installing, Restraining & Bracing of Metal Plate Connected Wood Trusses. 10 This document is a valuable marketing tool that shows customers the variety of possible truss configurations and educates them on correct terminology. It points out important truss elements, explains different types of trusses and provides graphics and names of 23 widely used truss profiles. 1-9 10-19 20-99 100+ This 19"x25.5" poster shows 23 widely-used truss configurations along with key truss elements and terminology. A must-have for your sales department. lots of 10 GENERAL PURPOSES 2.0 2.1 REQUIREMENTS OF THE OWNER $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 member price each non-member price each $16.00 14.50 13.00 $40.00 36.25 32.50 24 Building Permit. Where required by Legal Requirements, including the Building Code, the Owner shall obtain a Building Permit. If special inspections or structural observations related to Trusses are required as part of the Construction Documents and/or permitting process, these requirements shall be communicated in writing to the Contractor or Truss Manufacturer as appropriate. Engagement with the RDP/Building Designer. The Owner shall engage a RDP/Building Designer to prepare the Construction Documents. In the absence of a mandate to use an independent RDP/Building Designer, the Owner shall assume the role of Building Designer. Engagement with the Contractor. The Owner shall engage a Contractor to store, handle and install the Trusses for the Building, in compliance with any and all Legal Requirements. Review and Coordinate Submittal Packages. The Owner or Owner’s representative shall be responsible for ensuring that the requirements of Section 5.2 are accomplished. 2.5.2 2.6 Long Span Truss Requirements. Restraint/Bracing Design. In all cases where a Truss clear span is 60 ft. (18 m) or greater, the Owner shall contract with any RDP for the design of the Temporary Installation Restraint/Bracing and the Permanent Individual Truss Member Restraint and Diagonal Bracing. Special Inspection. In all cases where a Truss clear span is 60 ft. (18 m) or greater, the Owner shall contract with any RDP to provide special inspections to assure that the Temporary Installation Restraint/ Bracing and the Permanent Individual Truss Member Restraint and Diagonal Bracing are installed properly. Responsibility Exemptions. The Owner is responsible for items listed in Section 2.0, and is not responsible for the requirements of other parties specified outside of Section 2.0. 3.0 REQUIREMENTS OF THE RDP/ BUILDING DESIGNER 3.1 Construction Documents. The Construction Documents shall be prepared by a RDP/Building Designer and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in detail that such documents conform to the Legal Requirements, including the Building Code. Deferred Submittals. The RDP/Building Designer shall list the Deferred Submittals on the Construction Documents. The RDP/Building Designer shall review Deferred Submittals in accordance with Section 3.3. Review Submittal Packages. The RDP/Building Designer shall review the Truss Submittal Package for compatibility with the Building design. All such submittals shall include a notation indicating that they have been reviewed and whether or not they have been found to be in general conformance with the design of the Building for final approval prior to truss fabrication. Required Information in the Construction Documents. The RDP/Building Designer, through the Construction Documents, shall provide information sufficiently accurate and reliable to be used for facilitating the supply of the Structural Elements and other information for developing the design of the Trusses for the Building, and shall provide the following: (a) All Truss and Structural Element orientations and locations. (b) Information to fully determine all Truss profiles. (c) All Structural Element and Truss support 3.2 3.3 3.4 Copyright © 2002-2011 TTBDRESP-D 110412 (4 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 shipping units x qty. 24 TTBFloor-D Floor Truss Fact Sheet Truss Technology panel length rise butt cut peak 12 continuous lateral restraint web heel bearing heel height overall height wedge panel splice point bottom chord cantilever span (out-to-out of bearings) overhang Spread the news about the advantages of floor trusses! This document features several color photos and includes some common installation details and a time/material comparison between floor truss and stick frame construction. top chord truss plate truSS configurationS The only limitation is your imagination! $42.50 40.00 37.50 35.00 10 IN BUILDING The following examples represent only a small sampling of the many truss configurations being designed and built today. 2.4 The purpose of ANSI/TPI 1, Chapter 2, is to define and draw attention to the responsibilities of the Owner, Registered Design Professional for the Building or Building Designer, Contractor, Truss Design Engineer or Truss Designer, and Truss Manufacturer, with respect to the application of Trusses in the construction of a Building. 2.5 2.5.1 shipping units x qty. conf-p Truss Configurations Poster bottom chord length Standard roof truSS configurationS SciSSorS PolyneSian vaulted Parallel chord shipping units x qty. clereStory cantilevered ManSard w/ ParaPetS (4 pages) lots of 50 Mono half SciSSorS member non-member PRICE EACH LOT PRICE EACH LOT shipping units x qty. gaMBrel vault 1-9 10-19 20-99 100+ half hiP hiP rooM-in-attic 1-10 11-25 26+ 1.0 2.3 member non-member PRICE EACH LOT PRICE EACH LOT $17.00 16.00 15.00 14.00 shipping units x qty. The 2008 version contains the latest language from Chapter 2 of ANSI/TPI 1-2007, the National Design Standard for Metal Plate Connected Wood Truss Construction. ANSI/TPI 1 is the industry’s consensus standard and is referenced by the IBC and IRC. It is intended as a comprehensive and thorough approach to the clarification of design responsibilities when metal plate connected wood trusses are incorporated into a building or structure. The requirements are specifically categorized into two distinct areas – when the legal requirements mandate a Registered Design Professional is used and when they do not. This document is part of the Truss Technology in Building series. Standard Responsibilities in the Design and Application of Metal Plate Connected Wood Trusses PREAMBLE 2.2 (2 pages) lots of 50 member non-member PRICE EACH LOT PRICE EACH LOT TTBDRESP-D Standard Responsibilities in the Design and Application of Metal Plate Connected Wood Trusses TTBconf-D Truss Configurations I N B U I L D I N G This bilingual (English/Spanish) document depicts a generic truss design drawing with color-coded explanations for different information sections. Truss design drawings have long been a source of confusion for contractors, design professionals and building inspectors alike. Use this valuable tool to educate your market and increase understanding of truss design drawings. The last page lists tips to avoid installation errors for crews. Parallel chord chase flat vault 4x2 floor truSS with chaSe 130 dual Pitch SloPing flat BowString Studio vault 2x4 floor or roof truSS (can Be deSigned with a chaSe aS well) tray or coffer douBle cantilever Barrel vault tri-Bearing $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 24 truss technology in Building douBle inverted An informational series designed to address the issues and questions faced by professionals in the building construction process. 6300 Enterprise Lane • Madison, WI 53719 608/274-4849 • 608/274-3329 fax www.sbcindustry.com • [email protected] Multi-Piece / PiggyBack Copyright © 2002-2009 Structural Building Components Association. All Rights Reserved. Reproduction of this document, in any form, is prohibited without written permission from SBCA. This document should appear in more than one color. CONF-P-20090422 TTBcrane-d Crane Use & Proper Truss Handling TTBGABLE-d Gable End Frame Permanent Bracing (4 pages) lots of 50 member non-member PRICE EACH LOT PRICE EACH LOT shipping units x qty. Most manufactured gable end frames contain only flat vertical “studs”(as opposed to the typical Gable End Frame triangulated web members) and are designed to transfer only vertical roof loads (i.e., gravity and/or uplift) Armazón hastial directly into a continuous structural bearing below. Web member reinforcement, as shown on the Truss Design Drawing (TDD) for the gable end frame, is required to prevent column buckling of the web members due to the vertical loads applied to them. Continuous structural bearing - Pared continua de cojinete La mayoría de armazones hastiales fabricados contienen solamente “montantes” planos y verticales (a diferencia de los miembros secundarios triangulados típicos) y son diseñados para transferir solamente cargas de techo verticales (ej: gravedad y/o levantamiento) directamente a un soporte continuo debajo. Refuerzo de miembros secundarios, como mostrado en el Dibujo del Diseño del Truss (TDD) para el armazone hastiale, es requerido para prevenir que las columnas de los miembros secundarios fallen debido a las cargas verticales aplicadas a los trusses. In service, gable end frames often experience lateral loads applied parallel and perpendicular to their planes IN D from wind and/or seismic events. Gable end frames rely on properly designed and installed structural sheathing, bracing, and connections to the bearing wall, roof and ceiling diaphragms to adequately transfer these lateral loads. En servicio, armazones hastiales a menudo llevan cargas laterales aplicadas paraleles y perpendiculares a sus planos en casos sísmicos y/o de viento. Los armazones hastiales dependen en el entablado estructural, arriostre y conexiones diseñados e instalados apropiadamente a la pared soportante, y diafragmas de techo para transferir las cargas laterales adecuadamente. Design Considerations – Consideraciones de Diseno The goal is to transfer the lateral loads applied to the gable end frame safely into the wall and/or roof and ceiling diaphragm(s). La meta es de transferir seguramente las cargas laterales aplicadas al armazón hastial a la pared y/o diafragmas de techo. Lateral Force Transfer to Roof and Ceiling Diaphragms Gable End Frame Armazón Hastial Roof Diaphragm Diafragma de Techo 12 2016 $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 24 Inadequate design and/or construction can lead to several modes of failure. Sistemas diseñados inadecuados pueden fracasar en varias formas. Examples of Gable End Frame Permanent Bracing to resist Lateral Loads. Ejemplos de Arriostre Permanente de Diagonal bracing and blocking by Building Designer Armazón Hastial para resistir cargas Arriostre diagonal y bloqueando por laterales. el Diseñador del Edificio Gable End Frame by Truss Designer Armazón hastial por el Diseñador del Truss Ceiling Diaphragm Diafragma de Techo Structural Sheathing Entablado Estructural End wall – Pared de Extremo Ceiling diaphragm Diafragma de techo Blocking by Building Designer Bloqueando por el Diseñador del Edificio Excessive bow in Gable End Frame Doblado Excesivo en el Armazón Hastial Ceiling and finish cracking and related serviceability issues (i.e., construction defects) Agrietando de Techo y Acabado y Problemas Relacionados de Servicio (ejemplo: Defectos de Construcción) Gable End Frame by Truss Designer Armazón hastial por el Diseñador del Truss Gable End Frame-to-wall connection by Building Designer Conexión de Armazón a paredpor el Diseñador del Edificio Connection failure between top of end wall and bottom of Gable End Frame Fallo de conexión entre la pared y el armazón hastial. Copyright © 2012 SBCA – Structural Building Components Association. All Rights Reserved. 120104 Gable End Bracing.indd 1 Roof diaphragm Diafragma de Techo Horizontal L-reinforcement if required by Building Designer. Design attachment to resist both compression and tension forces. L-Refuerzo horizontal si requerido por el Diseñador del Edificio. Diseñe el conexión a resistir ambas fuerzas de compresión y tensión. Gable End Frame-to-wall connection by Building Designer Armazón hastial a pared por el diseñador del edificio Potential Modes of Failure Tipos de Fallo Potenciales 1-9 10-19 20-99 100+ This 2-page bilingual (English/Spanish) document discusses the importance of permanent bracing and/or reinforcement for the Gable End Frame and reviews some basic design considerations for this bracing. Gable End Frame Permanent Bracing Arriostre Permanente de Armazones Hastiales W Keep customers informed about responsibilities and key considerations for safe and efficient truss installations using mobile crane equipment. This bilingual (English/Spanish), 4-page TTB addresses crane size, hoisting trusses, rigging equipment and crane set up and inspection. Gable end wall Permanent Diagonal Bracing by Building Designer Arriostre Diagonal Permanente de Armazón Hastial por el Diseñador del Edificio. Blocking by Building Designer Bloqueando por el Diseñador del Edificio Bottom Chord Continuous Lateral Restraint and Diagonal Braces. See BCSI-B3 or as specified by the Building Designer Restricción Lateral Continua de la Cuerda Inferior y arriostres diagonales. Vea BCSI-B3 o como especifique por el Diseñador del Edificio TTBGABLE-120104 (2 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 shipping units x qty. 10 1/3/2012 10:05:41 AM ORDER ONLINE AT sbcindustry.com/pubs TTBHIBCHECK-D CANADATTBHIBCHECK-D Checklist for Handling & Installing Trusses TTBPlace-D How to Read a Truss Placement Diagram This bilingual (English/Spanish) document discusses the information provided in Truss Placement Diagrams. It answers many questions, such as what Placement Diagrams are, whether or not they're engineering documents, whether or not they should be sealed with an engineer's seal and why the truss industry supplies Placement Diagrams. This is a great educational tool that textually and visually addresses this important topic. This document provides customers with a simple checklist to use when handling and installing trusses, and summarizes important considerations for each phase of the project. It is also part of the JOBSITE PACKAGE. (2 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 shipping units x qty. 10 (English/Spanish) 40 (English/French) (2 pages) lots of 50 1-9 10-19 20-99 100+ TTBLONG-d Long Span Truss Installation This bilingual (English/Spanish) document outlines the precautions necessary for installing trusses 60' or greater in length. Part of the Long Span JOBSITE PACKAGE, it provides tips for the safe and efficient handling and installing of long span trusses. (2 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 shipping units x qty. 10 TtBmold-D Facts Regarding Mold on Wood Structural Building Components Concern about mold contamination has gained extensive media coverage, and awareness has mounted among builders, homeowners and insurance companies. This document lists facts, recommended reading and references. (4 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 shipping units x qty. 24 TtBmoldbA-D Builder Advisory on Mold As a builder, what can you do to minimize mold on wood structural building components? This document answers that question with a specific checklist for each stage of construction. Includes a reference list of additional information. (4 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 shipping units x qty. 1-9 10-19 20-99 100+ 2016 $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 $35.00 33.75 32.50 30.00 10 TTBtake5-D Take Five Take Five encourages contractors to “take five” minutes to think through issues that will assist truss manufacturers in helping projects to go smoothly and to avoid delays. Topics include checking over plans, production schedules, sealed truss designs and truss delivery. (2 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $14.00 13.50 13.00 12.00 $35.00 33.75 32.50 30.00 shipping units x qty. 10 TTBwall-D Considerations for Contractors Building with Wall Panels This document contains essential information for wall panel customers. There is a comparison of time and material savings provided by wall panels over stick framing from the Framing the American Dream® project. Included is a checklist that reviews important information typically required to ensure that wall panels are manufactured to the correct specifications. There is also a recommended procedure for wall panel installation with step-bystep instructions and graphics to help customers with the installation process. (This document is part of the Wall Panel JOBSITE PACKAGE.) (4 pages) lots of 50 1-9 10-19 20-99 100+ member non-member PRICE EACH LOT PRICE EACH LOT $17.00 16.00 15.00 14.00 $42.50 40.00 37.50 35.00 shipping units x qty. 24 T E C H N O L O G Y I N B U I L D I N G TTBBinder-D Truss Technology in Building Binder This document addresses the truths of partition separation and how it may be mistaken for what is sometimes called truss arching or truss uplift. The descriptions of partition separation, possible causes of the problem and diagrams showing helpful drywall techniques. member non-member PRICE EACH LOT PRICE EACH LOT $14.00 13.50 13.00 12.00 shipping units x qty. T R U S S 24 TTBPartsep-D Partition Separation Prevention and Solutions (2 pages) lots of 50 member non-member PRICE EACH LOT PRICE EACH LOT T T B shipping units x qty. 10 The TTB Binder includes three copies of each TTB/CTB documents currently available, along with samples of Framing the American Dream® and Future of Framing brochures. Offering a library on popular topics ranging from mold to partition separation to design responsibilities, this binder is ideal for component manufacturers and construction industry professionals. QUANTITY member PRICE EACH non-member PRICE EACH shipping units x qty. Each $36.00 $90.00 40 ORDER ONLINE AT sbcindustry.com/pubs 13 T R A I N I N G safeprog Operation Safety Program & S A F E T Y P R O G R A M S Operation Safety Manual, multi-media CD & DVD, eight safety posters, 20 employee handbooks (English) and one year of access to SBCA’s Operation Safety online program and resources. The Operation Safety Program includes the SBCA Forklift Certification Program, with a certification binder, multimedia CD & DVD, five forklift posters, five certificates and five authorized driver cards. In addition, the program includes the new SBCA Housekeeping Program for Combustible Dust, with a multimedia training DVD, a template housekeeping plan and a housekeeping checklist. For program renewal, please see product SafePlant-Year. Visit wtcatko.com for more information. QUANTITY DVD Version 1.0 Released March 2006 Copyright © 2008 WTCA ll Rights Reserved. 6300 Enterprise Lane • Madison, WI 53719 608/274-4849 • www.sbcindustry.com Copyright © 2014 Structural Building Components Association. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America. Fee for one individual Safety Coordinator proctored exam. 1 DVD Version 1.0 1 1 PROGRAM member price each $920.00 non-member price each $2,300.00 shipping units x qty. 360 $725.00 N/A For companies that have already purchased the Operation Safety Program and require access for subsequent years/additional plants. QUANTITY member price each non-member price each SUBSEQUENT YEARS/ ADDITIONAL PLANTS $510.00 $1,275.00 Copyright © 2008 WTCA ll Rights Reserved. This 5½"x 8½" Book offers simplified component manufacturing safety information. Topics include: ergonomics, lockout/tagout, powered industrial trucks (forklifts), hand tools, manufacturing equipment and more. Each book includes an Employee Safety Handbook Agreement Sheet. QUANTITY 1-9 10-49 50-99 100+ member price each $4.90 4.40 3.90 3.40 non-member price each $12.25 11.00 9.75 8.50 Copyright © 2008 WTCA ll Rights Reserved. 1 QUANTITY 1 Employee Training Modules ENGLISH DVD member non-member price each set price each set $116.00 $290.00 shipping units x qty. 3 ESmodSAFE Operation Safety Training Modules – English and Spanish Copyright © 2008 WTCA ll Rights Reserved. DVD Version 1.0 Released March 2006 Employee Training Modules ENGLISH DVD member non-member price each set price each set $200.00 Employee Training Module CD and DVD. Available in English or Spanish. DVD Version 1.0 Collection includes 10 Safety Handbooks, eight Safety Posters, one Employee Training CD and one Employee Training DVD. English or Spanish. 1 SmodSAFE Operation Safety Training Modules – Spanish Released March 2006 SADDSAFE Operation Safety Collection – Spanish QUANTITY EmodSAFE Operation Safety Training Modules – English shipping units x qty. EADDSAFE Operation Safety Collection – English $500.00 shipping units x qty. English CD & DVD and Spanish CD & DVD of Employee Training Modules. Copyright © 2008 WTCA - Representing the Structural Building Components Industry All Rights Reserved. Version 1.0 Released May 2008 QUANTITY 1 Los Módulos de la Instrucción del Empleado en el Español DVD member non-member price each set price each set $170.00 $425.00 shipping units x qty. 8 Copyright © 2008 WTCA ll Rights Reserved. DVD Version 1.0 Released March 2006 Employee Training Modules ENGLISH DVD 240 Copyright © 2008 WOOD TRUSS COUNCIL OF AMERICA All Rights Reserved. Version 1.0 Released May 2008 14 $290.00 shipping units x qty. SAFEplant-year Operation Safety Program – Additional Access ssafehand Operation Safety Employee Handbook – Spanish Copyright © 2014 Structural Building Components Association. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publishers. Printed in the United States of America. N/A member non-member price each set price each set QUANTITY Employee Training Modules ENGLISH DVD 6300 Enterprise Lane • Madison, WI 53719 608/274-4849 • www.sbcindustry.com $290.00 Annual program certification fee. esafehand Operation Safety Employee Handbook – English EMPLOYEE SAFETY HANDBOOK $116.00 shipping units x qty. SafeCertcorp Annual Location Certification Fee Employee Training Modules ENGLISH DVD Released March 2006 member non-member price each set price each set QUANTITY Operation safety Program G U I D E L I N E S S A F E T Y EMPLOYEE SAFETY HANDBOOK SafeCertInd Safety Coordinator Certification Exam Los Módulos de la Instrucción del Empleado en el Español DVD 2016 DVD Version 1.0 Released March 2006 Copyright © 2008 WTCA ll Rights Reserved. Employee Training Modules ORDER ONLINE AT sbcindustry.com/pubs EPOSTERSAFE Operation Safety Program – Poster Set (8) in English T R A I N I N G SPOSTERSAFE Operation Safety Program – Poster Set (8) in Spanish These 18"x24" durable color posters offer simple safety tips. They include: forklift safety, hand tool safety, lockout/tagout, proper lifting, roller presses, vertical presses and finishing rollers safety, saw safety, working in hot conditions and workplace violence. Each poster can be customized with your company's logo. available in 8-poster sets or individually. english or spanish! eforksafe-P (eNGLISH) sforksafe-p (SPANISH) ehotsafe-P (eNGLISH) shotsafe-P (SPANISH) eliftsafe-P (eNGLISH) sliftsafe-P (SPANISH) elotosafe-P (eNGLISH) slotosafe-P (SPANISH) & S A F E T Y member non-member shipping price each price each units x qty. $18.00 8 posters 1 SET $45.00 member non-member price each set price each set $128.00 epresssafe-P (eNGLISH) spresssafe-P (SPANISH) 5 $320.00 esawsafe-P (eNGLISH) ssawsafe-P (SPANISH) etoolsafe-P (eNGLISH) stoolsafe-P (SPANISH) eforkslow-P sforkslow-P eforklimit-P sforklimit-P eviolsafe-P (eNGLISH) sviolsafe-P (SPANISH) shipping units x qty. 40 EFORKPOSTERS Forklift Certification Program Posters – English SFORKPOSTERS Forklift Certification Program Poster – Spanish P R O G R A M S Available for purchase as a poster set of five or individually, these 18"x24" durable color posters offer simple safety tips for your forklift drivers and plant employees. They include: loaded/empty truck, slow down, pedestrian right-of-way, know your limitations, and must be 18. Each poster can be customized with your company’s logo. member non-member shipping price each price each units x qty. $18.00 5 posters 1 SET $45.00 eforkload-P Sforkload-P 5 available in 5-poster sets or individually. english or spanish! member non-member shipping price each set price each set units x qty. $80.00 $200.00 25 efork18-P sfork18-P 2016 eforkpedestrian-P Sforkpedestrian-P ORDER ONLINE AT sbcindustry.com/pubs 15 T R A I N I N G forkPROG SBCA Forklift Certification Program – English Operation Safety Forklift Certification Program Version 1.0 • October 2006 & S A F E T Y P R O G R A M S SBCA’s Forklift Certification Program (English) integrates training with hands-on exercises to provide a diversified course for your forklift operators. For new or experienced forklift operators, this program will help you train, evaluate and monitor your forklift operations. The Forklift Certification program includes a certification binder, multimedia CD & DVD, 5 safety posters, 5 certificates and 5 authorized driver cards. Quantity member price each non-member price each shipping units x qty. 1-4 PROGRAMS 5-19 PROGRAMS 20+ PROGRAMS $290.00 240.00 220.00 $725.00 600.00 550.00 290 The SBCA Housekeeping Program for Combustible Dust contains all you need to assess your company’s risk for combustible dust citations during an OSHA inspection and implement an effective industry-specific housekeeping program for your production facility. The training is broken out into three modules: the first helps you understand the risk of combustible dust; the second guides you through an assessment of your risk and the creation of a formal housekeeping plan; and, the third provides production employee training for effectively implementing your new housekeeping plan. Purchase the Housekeeping Program for Combustible Dust and you will receive: a multimedia training DVD, Spanish training modulue 3, an electronic template housekeeping plan and a housekeeping checklist. HOUSEKEEPING PROGRAM FOR COMBUSTIBLE DUST-english w/spanish SforkPROG SBCA Forklift Certification Program – Spanish Quantity member price each non-member price each shipping units x qty. 1-4 PROGRAMS 5-19 PROGRAMS 20+ PROGRAMS $175.00 165.00 155.00 $437.50 412.50 387.50 240 Purchase these authorized forklift driver cards when it's time to train or retrain your drivers for certification. quantity member PRICE EACH LOT non-member PRICE EACH LOT SHIPPING UNITS x QTY 1 Lot = 10 Cards $24.00 $60.00 5 Purchase these certificates of achievement for authorized forklift drivers when it's time to train or retrain your drivers for certification. quantity member PRICE each lot non-member PRICE each lot SHIPPING UNITS x QTY. 1 Lot (10 Certificates) $12.50 $31.25 5 EFORKCERTIFICATESets 10 Forklift Certificates and 10 Forklift Driver Cards – English Purchase these sets of extra certificates and authorized driver cards when it’s time to train more drivers for certification. Each set includes 10 authorized forklift driver cards and 10 certificates of achievement, which state that trainees have completed the Forklift Certification program. 1 Set (10 Certificates and 10 Cards) 2016 $29.00 $72.50 shipping units x qty. 10 $300.00 shipping units x qty. 5 member price each 1 PROGRAM non-member price each $84.00 shipping units x qty. 10 $210.00 iN-pLANT bASIC tRAINING Get help training and acclimating new employees with SBCA In-Plant Basic Training! It's an easy-tounderstand program created for new production employees or anyone needing a review of the basics. Ten modules cover an introduction to the industry, safety, key terms, tools, quality control, lumber, metal connector plates, truss design drawings, assembly and handling. In English and Spanish! ESBASICPROG -English/Spanish EBASICPROG -English Only SBASICPROG -Spanish Only non-member PRICE EACH $120.00 QUANTITY EFORKDRIVERCARDS 10 Forklift Driver Cards – English member PRICE EACH non-member price each HOUSEKEEPING PROGRAM FOR COMBUSTIBLE DUST The Spanish version of the Forklift Certification program includes the multimedia CD & DVD, 5 safety posters, 5 certificates and 5 authorized driver cards. quantity member price each QUANTITY 1 PROGRAM EFORKCERTIFICATES 10 Forklift Certificates – English 16 HOUSEKEEPPROG eHOUSEKEEPPROG Housekeeping Program for Combustible Dust ESBASICLOc -English/Spanish Includes a program DVD, a CD of customizable PowerPoints®, one year of online access to the program (unlimited seats), quizzes, five employee binders and one trainer binder. FULL SUBSCRIPTION FOR 1 LOCATION MEMBER NON-MEMBER ENGLISH AND SPANISH $890.00 $2,225.00 ENGLISH OR SPANISH 580.00 1,450.00 Unlimited access to educational modules for every person at one location for one year. A program DVD and CD of PowerPoints® included. EBASICLOc -English Only SBASICLOc -Spanish Only FULL SUBSCRIPTION FOR 1 LOCATION MEMBER NON-MEMBER ENGLISH AND SPANISH $500.00 $1,250.00 ENGLISH OR SPANISH 400.00 1,000.00 EBASICIND -English Access to online educational modules and additional online resources for one person for one month. SBASICIND -Spanish INDIVIDUAL ACCESS # OF SEATS ENGLISH OR SPANISH (MEMBER) ENGLISH OR SPANISH (NON-MEMBER) 1-4 $30.00 each $75.00 each 5-19 26.00 each 65.00 each 20+ 22.00 each 55.00 each ORDER ONLINE AT sbcindustry.com/pubs ESRENEWBASICPROG Includes continued access to online modules, quizzes, additional resources & updated DVD and -English/Spanish CD. ERENEWBASICPROG -English SRENEWBASICPROG -Spanish EBASICBINDER -English SBASICBINDER -Spanish EBASIC trainerbinder -English Only SZprogram Safety Zone Program SZsignpackage Safety Zone SIGN Package This package includes 10 vinyl Safety Zone signs and one diagram for how to build sign frames. (Two vinyl signs are needed for each frame.) ANNUAL RENEWAL FEE MEMBER NON-MEMBER ENGLISH AND SPANISH $175.00 $437.50 ENGLISH OR SPANISH $118.00 $295.00 ADDITIONAL TRAINER BINDERS (ENGLISH ONLY) MEMBER NON-MEMBER $62.00 $155.00 NON-MEMBER $28.00 $70.00 non-member PRICE EACH shipping units x qty. Each $260.00 $650.00 20 This inspection report is meant to be used as a checklist at each jobsite delivery. It protects your driver as it allows them to document and keep a record of each delivery. Each pad has 50 report forms. lots of 5 pads Safety Zone is a program that helps designate a safety zone for off-loading trusses at a jobsite. Safety Zone materials were designed to provide an industry-wide improved approach to designating such a safety zone. The Safety Zone program package includes everything you need to create a safe zone when delivering components to a jobsite. It includes one Guide to Creating a Work Safety Zone brochure, one lot of Safety Zone Delivery Inspection/Off-load Inspection Reports, 10 vinyl signs, and one diagram for building sign frames. (Two vinyl signs are needed for each frame.) quantity member PRICE EACH non-member PRICE EACH shipping units x qty. 1 2-5 6+ $290.00 270.00 245.00 $725.00 675.00 612.50 40 This 11"x17" laminated and folded guide gives drivers guidelines to distribute upon delivery at a jobsite. It covers roll off delivery, boom/crane delivery and forklift delivery. The guide encourages safe practices at the jobsite and demonstrates your commitment to safety. quantity member PRICE EACH non-member PRICE EACH shipping units x qty. 1-5 6-10 11+ $5.50 5.00 4.50 $13.75 12.50 11.25 10 1 2-5 6+ member non-member shipping PRICE EACH lot PRICE EACH lot units x qty. $21.00 18.00 16.00 $52.50 45.00 40.00 10 TruckProg truck Program Product transport is one of the greatest sources of risk and liability a component manufacturer faces. It also presents a significant injury risk, from loading and unloading of product, to travel on public roads. TRUCK is a comprehensive, industry-specific program that addresses the safety, risk and compliance aspects of material handling, product transport and safe operation of equipment. Includes Safety Zone package, CD of modules and one Truck Driver Handbook. TRUCK Program SZGuide Safety Zone Guide to Creating a Work Safety Zone TruckADDON Truck Add-On MEMBER NON-MEMBER shipping units x qty. $510.00 $1,275.00 240 & S A F E T Y P R O G R A M S Includes Safety Zone Guide, reports and one Truck Driver Handbook. TRUCK Add-on MEMBER NON-MEMBER shipping units x qty. $26.00 $65.00 10 Truckhandbook Truck Driver Handbook TRUCK Driver Handbooks summarize the most important information from the TRUCK training modules, and serve as a handy guide to keep in your CMVs. SZSign Safety Zone Sign These portable, durable signs are used to identify the delivery zone at the jobsite and promote safe handling and off-loading. Two vinyl signs are included for creating a two-sided sign. A diagram is also included for building the sign frame. Copyright © 2008 Structural Building Components Association. All Rights Reserved. 2016 member PRICE EACH SZInspectionReport Safety Zone Delivery Inspection Report/Off-load Inspection Report ADDITIONAL EMPLOYEE BINDERS (ENGLISH OR SPANISH) MEMBER quantity T R A I N I N G quantity member PRICE EACH non-member PRICE EACH shipping units x qty. Each $64.00 $160.00 10 Truck Driver Handbooks (2 pages) QTY. 1-9 10-49 50-99 100+ member non-member shipping PRICE EACH lot PRICE EACH lot units x qty. $4.90 4.40 3.90 3.40 $12.25 11.00 9.75 8.50 3 ORDER ONLINE AT sbcindustry.com/pubs 17 E D U C A T I O N A L C D S & P R O G R A M S FIREPRES-EV Wood Truss Construction and Fire Performance on CD Four Steps to Safe Truss Installations Wood Trusses and the IRC Four Steps to Safe Truss Installations Copyright © 2010 Structural Building Components Association All rights reserved. Copyright © 2010 Structural Building Components Association All rights reserved. Copyright © 2010 Structural Building Components Association All rights reserved. Take SBCA’s Component Technology Workshops (CTWs) with you on the go with CTW CDs! Perfect to hand out to customers or use as a “refresher” course, CTW CDs cover a wide range of topics and many CTWs qualify for continuing education credit (CEUs/PDHs). Four Steps to Safe Truss Installations Wood Trusses and the IRC Four Steps to Safe Truss Installations Copyright © 2010 Structural Building Components Association All rights reserved. Copyright © 2010 Structural Building Components Association All rights reserved. Copyright © 2010 Structural Building Components Association All rights reserved. Courses available on CD include: WS_BCSI-CD Overview of Building Component Safety Information FLOOR-EV Building with Floor Trusses on CD WS_4STEPS-CD Four Steps to Safe Truss Installations Building with Floor Trusses shows how to efficiently construct buildings using floor trusses. (11 min.) WS_FAD-CD Framing the American Dream WS_MOLDBA-CD Minimizing Mold on Structural Building Components WS_MOLD-CD Mold and Structural Wood Components WS_FBPE-CD Florida Board of Professional Engineers Rule 61G15-31.003 KEYS-EV Keys to Quality Wood Truss Production on CD Keys to Quality Wood Truss Production reviews strategies used by manufacturers to produce a quality wood truss. (20 min.) WS_IBC2006-CD Wood Trusses and the IBC (multiple versions available) WS_IRC2006-CD Wood Trusses and the IRC (multiple versions available) In addition to a narrated auto-run presentation on CD, SBCA component manufacturer members can also receive additional resources such as PowerPoint® versions of a given presentation (where applicable), and chapters receive special reduced pricing. quantity 1-19 20+ member PRICE EACH $42.00 34.00 non-member PRICE EACH $105.00 85.00 Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. 7 :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. 2016 Framing the American Dream® DVD shows what we learned about craftsmanship, ease of use and savings in component- vs. stickframing techniques. Side-by-side time-lapse footage highlights the advantages of framing with components in floor, wall and roof systems. (34 min.) Also available: FADSHORT-EV, FAD-D & FADRF-D. Four Steps to Safe Truss Installations Copyright © 2010 Structural Building Components Association All rights reserved. Four Steps to Safe Truss Installations Copyright © 2010 Structural Building Components Association All rights reserved. Quantity discounts apply only to multiples of the same product code. CD video is in .mpg file format. Minimum software requirements is Windows Media Player® v.6, Realplayer® or comparable software. Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association CTWSHIRB-EV Storage, Handling, Installation, Restraining and Bracing on CD shipping units x qty. FAD-EV Framing the American Dream® on DVD 18 Wood Truss Construction and Fire Performance, a CD from Carbeck Structural Components Institute (CSCI), focuses on educating firefighters with the goal of improving fire safety when it comes to structural building components. It also addresses the facts surrounding the performance of wood truss construction when subject to fire conditions. Condensed from the original version into a more concise, easy-to-deliver format, it offers 18 modules. Each module is about five to ten minutes long. Users can customize their training by viewing specific modules or the entire CD. Preview at carbeck.org. (Approx. 3 hrs.) BCSI – Storage, Handling, Installation, Restraining & Bracing is one of the Component Technology Workshop online courses that is available as a stand-alone CD. This CTW discusses how to unload, store, lift, erect, restrain, and brace metal plate connected wood trusses. It includes specific information for protecting trusses from weather and damage at the jobsite, how to lift individual trusses by crane, temporary restraining and bracing guidelines to prevent trusses from toppling during erection, installation tolerances to keep the trusses in-plane and plumb, and permanent bracing applications. Temporary and permanent bracing is an important yet overlooked element of safe truss installation and acceptable long-term structural performance. This CTW is based on the Building Components Safety Information (BCSI) Book. (44 min.) quantity member PRICE EACH non-member PRICE EACH 1 2-9 10-19 20-49 50-99 100+ $26.00 18.00 14.00 12.00 10.00 9.00 $65.00 45.00 35.00 30.00 25.00 22.50 shipping units x qty. 7 ORDER ONLINE AT sbcindustry.com/pubs DESIGNTOOLS-CD Design Tools CD The Design Tools CD provides architects, engineers, inspectors and builders with technical information in an interactive format. It includes: a virtual truss plant tour, truss configurations, Framing the American Dream® video, span tables, structural details for CAD, links to online resources and more. Perfect to hand out at tradeshows and seminars. fadshort-EV Framing the American Dream® Short Segment on CD Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association The Framing the American Dream® Short Segment is a condensed version of FAD-EV. Great for presentations, sales meetings and to distribute to potential customers. (10 min.) Also available: FAD-EV, FAD-D & FADRF-D. FPS-D SBCA 2015 Financial Performance Survey of Fiscal Year 2014 This document contains financial and operating information presented in balance sheet and income statement format. Data for the biennial survey is provided to SBCA by component manufacturer members and free to participants. Past years are available, email SBCA Staff for more information. The Financial Performance Survey alternates yearly with the Wage and Benefit Survey. See the SBCA Annual Survey web page for more information on participating in the surveys. MEMBER 2015 Financial Performance Survey for Fiscal Year 2014 quantity member PRICE EACH non-member PRICE EACH shipping units x qty. Each $1,600.00 N/A 20 WAGE-d SBCA 2014 Wage & Benefit Survey of Calendar Year 2013 :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. fadwall-ev Framing the American Dream® Wall Panel Demonstration CD Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association This document is a survey of wage and benefit information obtained biennially from SBCA component manufacturers. Free to participants. Past years are available, email SBCA Staff for more information. The Wage and Benefit survey alternates yearly with the Financial Performance Survey. See the SBCA Annual Survey web page for more information on participating in the surveys. For Calendar Year 2013 Framing the American Dream® – Wall Panel Demonstration is a condensed presentation that focuses strictly on the wall panel segment of the FAD video. (6 min.) quantity member PRICE EACH non-member PRICE EACH shipping units x qty. Each $1,600.00 N/A 20 Structural Building Components Association quantity member PRICE EACH non-member PRICE EACH shipping units x qty. :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. 1-19 20-99 100+ $13.00 11.00 10.00 $32.50 27.50 25.00 7 CALCUSLOPEf CalcuSlope Scale Requires Windows Media Player, formatted with auto open, press start. Structural Building Components Association This sturdy plastic scale with the "view-thru" window is the perfect tool for rapid roof slope verification, roof area calculations, rafter length tables, conversion tables, trigonometry formulas, scales and spacing guides for 1/4" and 1/8" plans, and more. Keep the estimating and design calculations for the truss and engineered wood products industry at your fingertips. QCPROGram SBCA QC In-Plant Wood Truss Program :10 minutes condensed version Copyright © 2002 SBCA All rights reserved. This new web version of the program helps manufacturers monitor the quality of the trusses they manufacture. This in-plant program consists of two main parts: 1) inspection procedures and 2) software for storing the results to see trends over time. This updated program now allows manufacturers to use any laptop or tablet with an internet connection to enter data from the completed inspections onto a secured website. Visit www.sbcindustry.com/wtcaqc.php to learn more about implementing the SBCA In-Plant Wood Truss QC Program at your plant and becoming "Certified." Contact staff to purchase. QCwallPROGram SBCA QC Wall Panel Program This program helps manufacturers monitor the quality of wall panels they manufacture and provides the plant with a data management system. The program consists of inspecting wall panels and entering data into the software program, allowing you to store data and create reports to evaluate the quality of the manufacturing process. This program also offers SBCA QC Wall Panel voluntary certification. quantity 1 Each Add’l 2016 member PRICE EACH $330.00 170.00 non-member PRICE EACH N/A quantity member PRICE EACH non-member PRICE EACH shipping units x qty. Each $15.00 $37.50 1 E D U C A T I O N A L C D S & P R O G R A M S depth Depth/Angle Gauge This item manufactured by General Tools Mfg. Co., Inc., (part# 444) is the ideal tool for measuring plate-lumber gaps and checking plate placement angles for the SBCA In-Plant Wood Truss QC Program. quantity member PRICE EACH non-member PRICE EACH shipping units x qty. Each $25.00 $62.50 1 shipping units x qty. 40 ORDER ONLINE AT sbcindustry.com/pubs 19 C O L D MEMBER PRICING APPLIES TO cfsc MEMBERS ONLY CFSBCSI-D CFSB3FLAT-P Cold-Formed Steel Building Component Safety InformaCFSB3FOLD-P tion Book – Guide to Good Practice for Handling, Installing, Permanent Restraint/Bracing of Chords & Web Members Restraining & Bracing of Metal Plate Connected Wood Trusses F O R M E D S T E E L The CFSBCSI-B3 Summary Sheet reviews the various planes of a truss that typically must be restrained and braced, and provides installation guidelines and permanent restraint/bracing for special conditions for trusses spaced up to 4' on-center. It summarizes Section B3 of the CFSBCSI Book, and has English and Spanish text. This size is perfect for printing structural framing plans on the reverse side. The CFSBCSI Book is a Guide to Good Practice for Handling, Installing, Restraining & Bracing of Cold-Formed Steel Trusses. Developed by SBCA’s Cold-Formed Steel Council (CFSC), this 8.5"x11" guide (3-hole punched and spiral bound) covers key concepts including setting trusses, permanent bracing and jobsite modifications. CFSBCSI also includes a 4-page insert with modifications to chapters CFSB1, CFSB2 and CFSB3, for use with trusses spaced at 4' on-center and up to 80' in length. QUANTITY member PRICE EACH non-member PRICE EACH 1-9 10-39 40-239 240+ $11.00 10.50 10.00 9.50 $27.50 26.25 25.00 23.75 UNITS PER BOOK 10 CFSB1FLAT-P CFSB1FOLD-P CFSBCSI-B1 Summary Sheet – Guide for Handling, Installing, Restraining & Bracing of Trusses P R O D U C T S The CFSBCSI-B1 Summary Sheet is for builders and provides industry guidelines for unloading, storing, lifting, erecting, installing, restraining and bracing trusses spaced up to 4' on-center. This document summarizes Section B1 of the CFSBCSI Book and has English and Spanish text. The full-color 11"x17" size is perfect for printing truss placement diagrams on the reverse side. member non-member shipping lots of 100 PRICE EACH LOT PRICE EACH LOT units x qty. 1-4 5-10 11-20 21+ $60.00 56.00 54.00 52.00 $150.00 140.00 135.00 130.00 45 CFSB2-D CFSBCSI-B2 Summary Sheet – Truss Installation & Temporary Restraint/Bracing The CFSBCSI-B2 Summary Sheet provides options for safe temporary restraint/bracing for trusses spaced up to 4' on-center. It simplifies how to get the first five trusses erected, restrained and braced efficiently and safely for the benefit of the crew and the project. This document summarizes Section B2 of the CFSBCSI Book and has English and Spanish text. 20 2016 member non-member lots of 100 PRICE EACH LOT PRICE EACH LOT (8 pages) lots of 25 member PRICE EACH LOT non-member PRICE EACH LOT shipping units x qty. 1-9 10-19 20-99 100+ $46.00 44.00 42.00 40.00 $115.00 110.00 105.00 100.00 40 CFSB4-D Construction Loading 1-4 5-10 11-20 21+ $60.00 56.00 54.00 52.00 $150.00 140.00 135.00 130.00 shipping units x qty. 45 The CFSBCSI-B4 Summary Sheet covers how trusses must not support any loads from equipment or construction materials during construction–until the truss assembly is properly restrained and braced. It also lists safe stack heights for several building materials and illustrates good and bad loading practices. It summarizes Section B4 of the CFSBCSI Book and has English and Spanish text. (2 pages) lots of 25 member PRICE EACH LOT non-member PRICE EACH LOT shipping units x qty. 1-9 10-19 20-99 100+ $13.00 12.50 12.00 11.500 $32.50 31.25 30.00 28.75 10 CFSB5-D Truss Damage, Jobsite Modications & Installation Errors The CFSBCSI-B5 Summary Sheet provides guidance for reporting damage, modifications or installation errors to the truss manufacturer/building designer in order to get an approved truss repair. It reviews common types of damage and modifications involving trusses. It summarizes Section B5 of the CFSBCSI Book and has English and Spanish text. (2 pages) lots of 25 member PRICE EACH LOT non-member PRICE EACH LOT shipping units x qty. 1-9 10-19 20-99 100+ $13.00 12.50 12.00 11.500 $32.50 31.25 30.00 28.75 10 CFSB11-D Fall Protection & Trusses The CFSBCSI-B11 Summary Sheet explains that trusses are NOT designed as fall protection anchors, and provides general guidelines to assist framing crews in safely and efficiently installing trusses while meeting OSHA's fall protection requirements. It summarizes Section B11 of the CFSBCSI Book and has English and Spanish text. (2 pages) lots of 25 member PRICE EACH LOT non-member PRICE EACH LOT shipping units x qty. 1-9 10-19 20-99 100+ $13.00 12.50 12.00 11.500 $32.50 31.25 30.00 28.75 10 ORDER ONLINE AT sbcindustry.com/pubs MEMBER PRICING APPLIES TO cfsc MEMBERS ONLY CFShibcheck-d Checklist for Handling & Installing Trusses This document provides customers with a simple checklist to use when handling and installing trusses, and summaries important considerations for each phase of the project. It has English and Spanish text and is part of the CFS JOBSITE PACKAGE. 7.2 7.3 7.4 7.5 7.6 Communication to Truss Designer. The Truss Manufacturer shall communicate the Truss design criteria and b3.2 requirements to the Truss Designer. I1.3.2 Alternate Truss Designs. If an alternative or partial set of Truss design(s) is proposed by the Truss Manufacturer, Truss Design Engineer or Truss Designer, such alternative set of design(s) shall be sent to and reviewed by the RDP/Building Designer prior to manufacturing. These alternative set of design(s) do not require the seal of the Truss Design Engineer until accepted by the RDP for the Building. Truss Placement Diagram. Where required by the Construction Documents or Contract, the Truss Manufacturer shall prepare the Truss Placement Diagram that identifies the assumed location for each individually designated Truss and references the corresponding Truss Design Drawing. The Truss Placement Diagram shall be permitted to include identifying marks for other products including Structural Elements, so that they may be more easily identified by the Contractor during field erection. When the Truss Placement Diagram serves only as a guide for Truss installation and requires no engineering input, it does not require the seal of a Truss I1.3.3 b3.3 Design Engineer or RDP. Required Documents. The Truss Manufacturer shall supply to the Contractor the Truss Submittal Package, including the Truss Design Drawings, a Truss Placement Diagram, if required by the Construction Documents or Contract, and the required Permanent Individual Truss Member Restraint and the method to I1.6 be used per Section I1.6. Special Application Conditions. The Truss Manufacturer shall be allowed to provide detail drawings to the Contractor to document special application conditions. Truss Submittal Packages. Where required by the Construction Documents or Contract, Legal Requirements or the Building Official, the Truss Manufacturer shall provide the appropriate Truss Submittal Package to one or more of the following: Building Official; RDP/ Building Designer and/or Contractor for review and/or b3.4 approval per Section D3. I1.3.4 Reliance on Construction Documents. The Truss Manufacturer shall be permitted to rely on the accuracy and completeness of information furnished in the Construction Documents or otherwise furnished in writing by the RDP/ b3.5 Building Designer and/or Contractor. I1.3.5 (2 pages) lots of 25 member PRICE EACH LOT non-member PRICE EACH LOT 1-9 10-19 20-99 100+ $12.50 12.00 11.50 11.00 $31.25 30.00 28.75 27.50 7.7 7.8 7.9 7.10 7.11 7.12 8.0 8.1 8.2 Fabrication Tolerance. The Truss Manufacturer shall determine the value for the Fabrication Tolerance to be used in the design of the Trusses. manufacturer Quality Criteria. The Truss Manufacturer shall manufacture the Trusses in accordance with the final Truss Design Drawings, using the quality criteria required by AISI S202-11 unless more stringent quality criteria is provided by the Owner in writing or E1 through the Construction Documents. g1.1 In-Plant Truss Inspections. Truss inspections, as required by the Jurisdiction, shall be performed at the manufacturer's facility using the manufacturer's In-Plant Quality Assurance Program monitored by an inspection agency approved by the Jurisdiction, and shall satisfy any quality control/quality assurance requirements for the Trusses, and shall satisfy any designated in-plant special inspection requirements for the Trusses. Responsibility Exemptions. The Truss Manufacturer is responsible for items listed in Section 7.0 of this document, and is not responsible for the requirements of other parties specified outside of Section 7.0. COnTRACTS 6300 Enterprise Lane • Madison, WI 53719 608/274-4849 • 608/274-3329 fax www.sbcindustry.com • [email protected] IN BUILDING SbCA's Cold-Formed Steel Council (CFSC) An informational series designed to address the issues and questions faced by professionals in the building construction process. 6300 Enterprise Lane • Madison, WI 53719 608/274-4849 • 608/274-3329 fax cfsc.sbcindustry.com • [email protected] 10 Colocación de Trusses y Restricción/Arriostre de Instalación Para trusses hasta 4 pies en-centro y hasta 80 pies de longitud w WARNINg! Spans over 60' (18.3 m) require more complex temporary installation restraint/bracing. Consult a registered design professional. ¡AdvERTENCIA! Los tramos más de 60 pies requieren restricción/arriostre temporal de instalación más complejo. Consulte a un profesional registrado de diseño. dANgER! Disregarding handling, installing, restraining and bracing safety recommendations is the major cause of truss erection/installation accidents. ¡PELIgRO! El indiferencia de las recomendaciones de seguridad del manejo, instalación, restricción y arriostre es la causa principal de los accidentes de erección/instalación de trusses. Lateral restraint is NOT adequate without diagonal bracing. La restricción lateral NO es adecuada sin el arriostre diagonal. Always diagonally brace for safety! ¡Siempre arriostre diagonalmente para seguridad! a r TCILR shown in green. *Note: Maximum spacing for TCILR. Digaonal bracing shown in red. n 10' o.c. (3 m) max.* Truss (9.1 Spans up to m) 30' 8' o.c. (2.4 max.* m) ≈45° Typical up to 45' (13.7 m) 6' o.c. (1.8 max.* m) up to (18.3 60' m) 4' o.c. (1.2 max.* m) up to (24.4 80'** m) **Note:Spansover60'(18.3m)requiremorecomplexinstallation restraint/bracing.Consultaregistereddesignprofessional. i unloading and storing n g ! con el suelo después de entrega. Si los trusses estarán guardados horizontalmente para más de una semana, ponga bloqueando de altura suficiente debajo de la pila de los trusses a 8 Building dimensions match the construction documents. Lasdimensionesdeledificioconcuerdanconlosdocumentosdeconstrucción. Topsofbearingsupportsareflat,levelandatthecorrect Bearing supports (e.g., walls, columns, headers, beams, etc.) are accurately and securely installed, plumb and properly braced. Los soportes de cojinete que sostienen cargas (ej., paredes, columnas, vigas de cabezera, vigas, etcétera) son instalados seguramente y con precisión, y son nivelados y arriostrados apropiadamente. Hangers, angle clips, tie-downs and restraint/bracing materials are on site and accessible. Los colgadores (hangers), soportes de anclaje (tie-downs) y materiales de restricción/arriostre están en la obra y accesibles. Erection/installation crew is aware of installation plan and lateral restraint/diagonal bracing requirements. El personal de erección/instalación es consciente del plan de instalación y los requisitos de restricción/lateral arriostre diagonal. Multi-ply trusses, including girders, are correctly fastened together prior to lifting into place. Los trusses de varias capas, incluyendo travesaños, son sujetados juntos correctamente antes de levantarlos en lugar. Any truss damage is reported to the truss manufacturer. Refer to CFSBCSIB5 – TrussDamage,JobsiteModificationsandInstallationErrors.*** Do not install damaged trusses unless instructed to do so by the building designer, truss designer or truss manufacturer. Algúndañoalostrussesesreportadoalfabricantedetrusses.Refieraal CFSBCSI-B5 – Daño a los Trusses, Modifaciones en la Obra y Errores de Instalación.*** No instale trusses dañados a menos que se dijeren el diseñador deledificio,eldiseñadordeltrussoelfabricantedeltruss. CFSBCSI-B2 SUMMARY SHEET Soporte del pico los trusses de 20’ o menos. MECHaniCaL HOiSTing rECOMMEnDaTiOnS FOr SingLE TrUSSES rECOMEnDaCiOnES Para EL LEVanTaMiEnTO MECániCO DE TrUSSES inDiViDUaLES Hold each truss in position with the erection equipment until top Spreader bar for truss ging and hoisting equipment. El uso de un solo lugar en el pico de levantar puede hacer daño al truss. Tagline Locate above mid-height nO almacenar verticalmente los trusses no arriostrados. Tagline Attach to truss at 10' (3 mm) o.c. max. Spreader bar or stiffback Toe-in Spreader bar 1/2 to 2/3 truss length For trusses up to 60' (18.3 m) Tagline ente. Groundbracingprocedureforfirsttrussisbasedonsite Refer to CFSBCSi*** for more detailed information pertaining to handling and jobsite andbuildingconfiguration. storage of trusses. El procedimiento de arriostre de tierra para el primer Refiera a CFSBCSi*** para información más detrussesbasadoenlaconfiguracióndeledificioydeltertallada sobre el manejo y almacenaje de trusses reno. en la obra. If ground level is too far from truss for exterior ground bracing, use interior ground bracing. Refiera a CFSBCSi-B2*** para más información. ground. Almacénelos en terreno liso. Max. Spacing 20’ (6.1 m) 150F125-33 or 250S162-33 150F125-33 or 250S162-33 150F125-33 or 250S162-33 150F125-33 or 250S162-33 250S162-33 or Double1150F125-33 150F125-33 150F125-33 or 250S162-33 250S162-33 or Double1150F125-33 150F125-33 Top Chord Installation Lateral Restraint (TCILR) and diagonal bracing is 33 mil 1-½” (38 mm) furring (hat) channel (150F125-33) or 33 mil 2-½” (64 mm) stud section (250S162-33) unless specified by the building designer. Attach to each truss with min. 2-#10 self-drilling tapping screws (SDS). 8’ (2.4 m) o.c. max. 2’ (0.6 m) 6’ (1.8 m) o.c. max. 4’ (1.2 m) 6’ (1.8 m) o.c. max. 2’ (0.6 m) 4’ (1.2 m) o.c. max. 4’ (1.2 m) 4’ (1.2 m) o.c. max. (see table in the next column). ground bracing connections should be min. 3-#10 SDS. 20’ (6.1 m) nO caminar en trusses sin arriostre. D (ft.) 1' (0.3 m) 2' (0.6 m) 3' (0.9 m) 4' (1.2 m) 5' (1.5 m) 6' (1.8 m) 7' (2.1 m) ≥8' (≥2.4 m) DO nOT proceed with construction until all lateral restraint and bracing is securely and properly in place. nO proceder con la construcción hasta que todas las restricciones laterales y los arriostres están colocados en forma apropiada y segura. 20’ (6.1 m) 20’ (6.1 m) 12’ (3.7 m) 20’ (6.1 m) 20’ (6.1 m) DO nOT exceed maximum stack heights. nO excedir las alturas máximas de montón. 12’ (3.7 m) nEVEr stack materials near a peak or at midspan. nUnCa amontonar los materiales cerca de un pico o en medio-plano. Refer to CFSBCSiB3*** for gable end frame restraint/bracing/reinforcement information. Truss Length* Longitud del Truss 3/4" (19 mm) 7/8" (22 mm) 1" (25 mm) 1-1/8" (29 mm) 1-1/4" (32 mm) 1-3/8" (35 mm) 1-1/2" (38 mm) 1-3/4" (44 mm) 2" (51 mm) 12-6-0 (3.8 m) 14-7-3 (4.4 m) 16-8-6 (5.1 m) 18-9-10 (5.7 m) 20-9-10 (6.3 m) 22-10-13 (7 m) 25-0-0 (7.6 m) 29-2-6 (8.9 m) ≥33-3-10 (≥10.2 m) Maximum Stack Height for Material on Trusses1, 2 Maximua altura de Montón para Material encima de los Trusses Material – Material Height – Altura Gypsum Board – Tabla de Yesa 12" (305 mm) 22 ga. Type “B” 1 1/2" (38mm) metal deck – 21 sheets 20 ga. Type “B” 1 1/2" (38mm) metal deck – 17 sheets 18 ga. Type “B” 1 1/2" (38mm) metal deck – 13 sheets tipo “B” 1 ½” cubierta de metal de indicio 22 tipo “B” 1 ½” cubierta de metal de indicio 20 Plywood or OSB – contrachapado o OSB 16" (406 mm) 2 bundles paquetes Concrete block – Bloque de Hormingón 8" (203 mm) Clay Tile – Teja de Arcilla 3-4 tiles high Coloque las cargas sobre tantos trusses como sea posible. azulejos 1. This table is based on trusses designed with a live load of 40 psf (1915 Pa) or greater. For other loading conditions, contact a registered design professional. 2. Install stacks of materials as quickly as possible. Position loads over load bearing walls. 4’ o.c. max. Diagonal bracing Coloque las cargas sobre las paredes soportantes. aLTEraTiOnS — aLTEraCiOnES Web members Truss bracing not shown for clarity. Refer to CFSBCSi-B5*** for more information on truss damage, jobsite modifications and installation errors. Refiera a CFSBCSi-B5*** para más información sobre daño a trusses, modificaciones en la obra y errores de instalación. La rESTriCCión LaTEraL Y EL arriOSTrE DiagOnaL SOn MUY iMPOrTanTES DO nOT cut, bend, drill, remove or otherwise alter any member of a truss unless specifically permitted by the truss design drawing. nO cortar, doblar, perforar, remover o cambiar de otro modo a ningún miembro de un truss a menos que específicamente permitido por el dibujo del diseño de truss. Bottom chords Same spacing as bottom chord lateral restraint láminas láminas Asphalt shingles – Teja de Asfalto 4’ o.c. max. láminas tipo “B” 1 ½” cubierta de metal de indicio 18 Place loads over as many trusses as possible. 2) wEB MEMBEr PLanE — PLanO DE LOS MiEMBrOS SECUnDariOS 15' max. (4.6 m) for bottom chord installation lateral restraint, or per truss design drawing for bottom chord permanent lateral restraint. Max. Bow Doblación Máximo DO nOT overload small groups or single trusses. nO sobrecargar pequeños grupos o trusses individuales. See Table above “Nested” or “Stacked” short member lateral restraint (hat channel only) overlap each piece a minimum 6” (152 mm) and attach to truss with min. 2-#10 SDS. Diagonal braces every 20' (6.1 m) max. Trusses that have been overloaded during construction or altered without the Truss Manufacturer’s prior approval may render the Truss Manufacturer’s limited warranty null and void. note: Some chord and web members not shown for clarity. Trusses que se han sobrecargados durante la construcción o han sido alterados sin la autorización previa del Fabricante de Trusses, pueden hacer nulo y sin efecto la garantía limitada del Fabricante de Trusses. Contact the component manufacturer for more information or consult a registered design professional for assistance. To view a non-printing PDF of this document, visit www.cfsc.sbcindustry.com/cfsb1. *** nOTE: The methods and procedures outlined in this document are intended to ensure that the overall construction techniques employed will put the trusses into place SAFELY. These recommendations for handling, installing, restraining and bracing trusses are based upon the collective experience of leading personnel involved with truss design, manufacture and installation, but must, due to the nature of responsibilities involved, be presented only as a GUIDE for use by a qualified building designer or contractor. It is not intended that these recommendations be interpreted as superior to the building designer’s design specification for handling, installing, restraining and bracing trusses, and it does not preclude the use of other equivalent methods for restraining/bracing and providing stability for the walls, columns, floors, roofs and all the interrelated structural building components as determined by the contractor. Thus, SBCA, CFSC and those who participated in the development of this guide expressly disclaim any responsibility for damages arising from the use, application, or reliance on the recommendations and information contained herein. Bottom chords DO nOT walk on unbraced trusses. D/50 *U.S. customary units are in feet-inches-sixteenths “Overlapped” lateral restraint option (one truss space) ≈90° El tamaño mínima de la sección del acero utilizado como restricción lateral y arriostre diagonal es 33 mil 1-1/2” furring (hat) channel (150F125-33) o 33mil 2-1/2” sección de tachuela (250S162-33) a menos que especificado por el diseñador del edificio. Sujete a cada truss con un mínimo de 2-#10 tornillos autoperforantes (SDS). Coloque los arriostres de tierra para el primer truss directamente en línea con todas las filas de TCILR (vea la tabla en la próxima columna). Conexiones de arriostre de tierra deben ser un mínimo de 3-#10 SDS. D/50 max *** for TCILR options. Vea el CFSBCSi-B2*** para las opciones de TCILR. 3) BOTTOM CHOrD — CUErDa inFEriOr Locate ground braces for first truss directly in line with all rows of TCILR Plumb line Out of Plumb Fuera-de-Plomada 1/4" (6 mm) 1/2" (13 mm) 3/4" (19 mm) 1" (25 mm) 1-1/4" (32 mm) 1-1/2" (38 mm) 1-3/4" (44 mm) 2" (51 mm) COnSTrUCTiOn LOaDing Carga DE COnSTrUCCión Double assumes nested 2-piece 150F125-33 attached together with #10 SDS at 12" (300 mm) o.c. Consult a registered design professional for trusses longer than 60' (18.3 m). LaTEraL rESTrainT & DiagOnaL BraCing arE VErY iMPOrTanT Spreader Bar 2/3 to 3/4 truss length For trusses up to and over 60' (18.3 m) inSTaLLaTiOn rESTrainT & BraCing rESTriCCión Y arriOSTrE DE inSTaLaCión The minimum size steel section used as lateral restraint Store on even Min. Size/grade note: Ground bracing not shown for clarity. Spreader bar Toe-in DO nOT store unbraced bundles upright. Diagonal Bracing Min. Size/grade See CFSBCSi-B2 “Overlapped” short member lateral restraint. Extend end of each piece a minimum of 1 ½” (38 mm) past truss chord and attach to truss with min. 2-#10 SDS each piece. Up to 1/2 Truss length For trusses up to 30' (9.1 m) Refer to CFSBCSi-B2*** for more information. elevation. La parte superior de los soportes de cojinete son planas, niveladas y a la elevación correcta. For trusses stored for more than one week, cover bundles to protect from the environment. Jobsite is clean and neat, and free of obstructions. trusses guardados por más de una semana, La obra está limpia, ordenada y sin obstrucciones.Para cubra los paquetes para protegerlos del ambi- Lateral restraint TCiLr Spacing 10’ (3 m) o.c. max. 60° or less Using a single pick-point at the peak can damage the truss. Use equipo apropiado para levantar e improvisar. Truss Spacing 2’ (0.6 m) 4’ (1.2 m) 2’ (0.6 m) 4’ (1.2 m) Para información sobre restricción/arriostre/refuerzo para armazones hastiales refiera a CFSBCSi-B3*** chord installation lateral restraint is installed and the truss is fastened to the bearing points. Sostenga cada truss en posición con equipo de grúa hasta que la restricción lateral temporal de la cuerda superior es instalado y el truss es sujetado a los soportes. Use proper rig- Truss Span Up to 30’ (9.1 m) 30’ (9.1 m) 45’ (13.7 m) 45’ (13.7 m) 60’ (18.3 m) 1 Trusses up to 30' (9.1 m) Trusses hasta 30’ Max. Bow Length 1) TOP CHOrD inSTaLLaTiOn LaTEraL rESTrainT (TCiLr) & DiagOnaL BraCing 2 Soporte de los cuartos de tramo los trusses de 30’ o menos. Trusses up to 20' (6.1 m) Trusses hasta 20’ Max. Bow Length Length Tolerancias para Fuera-de-Plomada. Estas pautas de arriostre y restricción la instalación son para todos pérfiles de truss. 60’ (18.3 m) 80’ (24.4 m)2 (9.1 m) or less, support at quarter points. (6.1 m) or less, support at peak. Trusses are the correct dimension. Los trusses son la dimensión correcta. Interior tion. Coloque paquetes de trusses en una posición estable. Tolerancias para Fuera-de-Plano. Max. Bow Tolerances for Out-of-Plumb. These installation restraint and bracing guidelines are for all truss profiles. Trusses 30' Trusses 20' ¡CaUTELa! Utilice cuidado especial en días ventosos o cerca de cables eléctricos o de aeropuertos. the stack of trusses at 8’ (2.4 m) to 10’ • El arriostre de tierra no está mostrado para claridad. (3 m) on-center (o.c.). Store on slight slope to allow for draining. • Aplique el arriostre diagonal o el entablado estructural (structural Losmétodo trusses pueden ser descargados directasheathing) inmediatamente. Para tramos más de 60 pies el mente en el suelo en aquel momento de entrega preferido es aplicar el entablado estructural inmediatamente. o almacenados temporalmente en contacto hasta 10’ en-centro (o.c.). Almacénelos en una CHECk THESE ITEMS BEFORE STARTINg ERECTION/INSTALLATION ANd CORRECT AS NEEdEd cuesta ligera para permitir la desaguar. REvISE ESTOS PUNTOS ANTES dE EMPEZAR LA ERECCIÓN/INSTALACIÓN Y CORRÍJALOS CUANdO ES NECESARIO Place truss bundles in a stable configura- Out of Plane — Fuera-de-Plano Tolerances for Out-of-Plane. trusses with TCILR (see below). 4) Install top chord diagonal bracing (see below). 5) Install web member plane diagonal bracing (see below). 6) Install bottom chord installation lateral restraint (BCILR), (see below). 7) Install bottom chord diagonal bracing (see below). 8) Continue installing trusses repeating steps 4, 5, 6 and 7. rESTrainT/BraCing FOr aLL PLanES OF TrUSSES rESTriCCión/arriOSTrE Para TODOS PLanOS DE TrUSSES inSTaLaCión DE TrUSSES inDiViDUaLES POr La ManO HanDLing — ManEjO en-centro Trusses may be unloaded directly on the ground El dibujo a la izquierda muestra el espaciamiento máximo at the time of delivery or stored temporarily in (vea * a la izquierda) del TCILR basado en los tramos de trusses contact de withla the ground after delivery. If trusses are to be stored horizontally for more than one tabla en el Paso 2 en la página 2. week, place blocking of sufficient height beneath 1) Install ground bracing. 2) Set first truss and attach securely to ground bracing. 3) Set next 4 1) Instale arriostre de tierra. 2) Coloque el primer truss y átelo seguramente al arriostre de tierra. 3) Coloque los cuatro siguientes trusses con TCILR (vea abajo). 4) Instale el arriostre diagonal a la cuerda inferior (vea abajo). 5) Instale el arriostre diagonal al plano de miembro secundario. 6) Instale restricción lateral a la cuerda inferior (BCILR), (vea abajo). 7) Instale arriostre diagonal a la cuerda inferior (vea abajo). 8) Continua a instalar los trusses por repitiendo los pasos 4, 5, 6 y 7. warning! Do not over load supporting structure with truss bundle. ¡aDVErTEnCia! No sobrecargue la estructura apoyada con el paquete de trusses. inSTaLLaTiOn OF SingLE TrUSSES BY HanD CaUTiOn! Exercise care when removing banding or metal attachment pieces to avoid damaging trusses and prevent personal injury. Gloves and safety glasses should be worn. ¡CaUTELa! Utilice cautela al quitar las ataduras o los pedazos de metal de sujetar para evitar daño a los trusses y prevenir la herida personal. Guantes y gafas de seguridad deben ser llevadas. CaUTiOn! Use special care in windy weather or near power lines and airports. Avoid lateral bending. Evite la flexión lateral. The graphic at left shows the maximum on-center spacing (see * at at the the trusses jobsite. Unload left) of TCILR based on truss span from the table in Step 2 on page 2. trusses to smooth surface to • Ground bracing not shown for clarity. prevent damage. El contratista tiene la responsabilidad de • Apply diagonal bracing or structural sheathing immediately. For spans recibir, descargar y almacenar adecuadamente over 60' (18.3 m) applying structural sheathing immediately is theen la obra. Descargue los trusses los trusses en una superficie lisa para prevenir el daño. preferred method. DO nOT rely on banding or metal pieces used to attach trusses in a bundle to hoist and move bundles on the jobsite. nO dependa de las ataduras ni los pedazos de metal usados para conectar los trusses en un paquete para levantar y mover los paquetes en la obra. ted anywhere along the chords. Puntos de levantamiento para levantar un paquete de trusses son permitidos dondequiera por el vano de las cuerdas. trusses up to 45’ (13.7 m). Use at least 3 lift points for bundles with trusses greater than 45’ (13.7 m). Puede usar dos puntos de levantar para paquetes más de 45’. Use por lo menos tres puntos de levantar para paquetes más de 45’. ¡aDVErTEnCia! El resultado del manejo, levantamiento, instalación, restricción y arrisotre incorrecto puede ser la caída de la estructura o, aún peor, herida seria o muerto. inSTaLLing — inSTaLaCión STEPS TO SETTing TrUSSES LOS PaSOS DE La inSTaLaCión DE LOS TrUSSES DO nOT overload the crane. nO sobrecargue la grúa. Lift points for hoisting truss bundles are permit Two lift points may be used for bundles with warning! The consequences of improper handling, erecting, installing, restraining and bracing can result in a collapse of the structure, or worse, serious personal injury or death. MAxIMUM SPACINg FOR TOP CHORd INSTALLATION LATERAL RESTRAINT (TCILR) The contractor is responsible for EL ESPACIAMIENTO MÁxIMO PARA LA RESTRICCIÓN LATERAL dE INSTALACIÓN dE LA CUERdA SUPERIOR (TCILR) properly receiving, HOiSTing anD PLaCEMEnT OF TrUSS BUnDLES LEVanTaMiEnTO Y COLOCaCión DE PaQUETES DE TrUSSES Diagonal braces every 20' (6.1 m) max. “Nested” lateral restraint option 6300 Enterprise Lane • Madison, WI 53719 • 608/274-4849 • www.sbcindustry.com • www.cfsc.sbcindustry.com CFSB1warn11x17 081022 HOja DE rESUMEn – gUía DE BUEna PráCTiCa Para EL ManEjO, inSTaLaCión, rESTriCCión Y arriOSTrE DE TrUSSES espaciados hasta 4’ en-centro Si el nivel del terreno es demasiado lejos del truss para usar arriostre de tierra exterior, use arriostre de tierra interior. Exterior Tramos más de 60’ pueden requerir arriostre permanente complejo. Por favor, siempre consulte a un profesional registrado de diseño. CFSB2Temp 081022 RESUMEN CFSBCSI-B2 The CFS JOBSITE PACKAGE is a critical tool in helping component manufacturers fulfill their duty to educate and warn customers with important installation and safety information. The package comes pre-assembled in a zippered plastic bag (10" x 14") and includes a cover sheet, CFSB1 through CFSB4 and SCC Checklist for Handling and Installing Trusses. All documents include English and Spanish text. (Min. order 25) member quantity PRICE EACH LOT 25-99 $6.15 100-499 5.90 500-999 5.65 1000-1999 5.35 2000+ 5.15 non-member shipping PRICE EACH LOT units x qty. $15.38 14.75 14.13 3 13.38 12.88 CFSJOBSITECS-D Steel Jobsite Cover Sheet JOBSITE PACKAGE IMPORTANT DOCUMENTS ENCLOSED PLEASE REVIEW WARNING: The handling, storing, installing, restraining and diagonal bracing of structural building components requires specialized training, clearly implemented procedures, and careful planning and communication among the contractor, crane operator and installation crew. Handling and installing components without appropriate training, planning and communication greatly increases the probability of an accident resulting in property damage, serious personal injury and/or death. Prior to truss installation, the documents should be examined and disseminated to all appropriate personnel, in addition to proper training and a clear understanding of the installation plan, any applicable fall protection requirements, and the intended restraint and bracing requirements. Trusses with clear spans of 60 feet (18.3 m) and greater are very dangerous to install and may require complex installation and permanent bracing. Consult a Registered Design Professional. Examine the building, the building’s structural framing system, bearing locations and related installation conditions. Begin component installation only after any unsatisfactory conditions have been corrected. Do not cut, modify or repair components. Report any damage before installation. The enclosed documents are offered as minimum guidelines only. Nothing contained in this JOBSITE PACKAGE should be construed in any manner as expanding the scope of responsibility of, or imposing any additional liabilities on, the truss manufacturer. ¡ADVERTENCIA!: El manejo, almacenamiento, instalación, restricción y arriostre diagonal de componentes estructurales de construcción requieren entrenamiento especializado, procedimientos claramente implementados, y planificación y comunicación clara entre el contratista, operador de grúa, y los obreros de instalación. El manejo e instalación de componentes sin el entrenamiento suficiente, planificación ni comunicación adecuada aumenta la probabilidad de un accidente que pueda resultar en daño a propiedad, la herida seria o la muerte. Antes de la instalación de trusses, los documentos adjuntos deben ser examinados y difundidos a todo el personal apropiado, además del entrenamiento pertinente y un entendimiento claro del plan de instalación, cualquier requisito aplicable de la protección contra la caída y los requisitos de arriostre y restricción previstos. La instalación de trusses más de 60 pies de largo es muy peligrosa. Siempre consulte a un Profesional de Diseño Registrado. The cold-formed steel JOBSITE PACKAGE cover sheet has English/Spanish warnings on the front and paraphrased portions from AISI S214-07/ S2-08, Supplement 2 to The North American Standard for Cold-Formed Steel Framing – Truss Design on the back. It includes construction-related items and truss manufacturer responsibilities. Examine la estructura, el sistema de armazón estructural del edificio, ubicaciones de soporte y las condiciones de instalación correspondientes. Solamente comience con la instalación de componentes después de que todas condiciones insatisfactorias han sido corregidas. No corte, modifique, ni repare los componentes. Informe cualquier daño antes de la instalación. Los documentos adjuntos se ofrecen solamente como pautas mínimas. Nada de lo incluido en este PAQUETE DE OBRA debe ser interpretado de manera que exceda el alcance de la responsabilidad del fabricante de trusses, ni en forma de tal que imponga responsabilidades adicionales sobre éste. LOTS OF 25 To view a non-printing PDF of this document, visit www.cfsc.sbcindustry.com/cfsjobsitecs. FOR DESIGN RESPONSIBILITIES SEE REVERSE 2016 1 member non-member price each set price each set $7.50 $18.75 gEnERAl PURPOSES 2.0 2.1 REQUIREmEnTS OF THE OWnER 2.4 2.6 AISI S214-07/ S2-08 1.0 2.3 2.5.2 The purpose of AISI S202-11 is to define and draw attention to the responsibilities of the Owner, Registered Design Professional (RDP) for the Building or Building Designer, Contractor, Truss Design Engineer or Truss Designer, and Truss Manufacturer, with respect to the application of Trusses in the construction of a Building. building Permit. Where required by Legal Requirements, including the Building Code, the Owner shall obtain a Building Permit. If special inspections or structural observations related to Trusses are required as part of the Construction Documents and/or permitting process, these requirements shall be communicated in writing to the Contractor or Truss Manufacturer as appropriate. Engagement with the RDP/building Designer. The Owner shall engage a RDP/Building Designer to prepare the Construction Documents. In the absence of a mandate to use an independent RDP/Building Designer, the Owner shall assume the role of Building Designer. Engagement with the Contractor. The Owner shall engage a Contractor to store, handle and install the Trusses for the Building, in compliance with any and all Legal Requirements. Review and Coordination Submittal Packages. The Owner or Owner’s representative shall be responsible for ensuring that the requirements of Section 5.2 of D3 b3.4.1 this document are accomplished. long Span Truss Requirements. Restraint/bracing Design. (2012 IbC 2211.3.3) In all cases where a Truss clear span is 60 ft. (18 m) or greater, the Owner shall contract with a RDP for the design of the Temporary Installation Restraint/ Bracing and the Permanent Individual Truss Member Restraint and Diagonal Bracing. Special Inspection. (2012 IbC 1705.2.2.2) In all cases where a Truss clear span is 60 ft. (18 m) or greater, the Owner shall contract with a RDP to provide special inspections to assure that the Temporary Installation Restraint/Bracing and the Permanent Individual Truss Member Restraint and Diagonal Bracing are installed properly. Responsibility Exemptions. The Owner is responsible for items listed in Section 2.0 of this document, and is not responsible for the requirements of other parties specified outside of Section 2.0. 3.0 REQUIREmEnTS OF THE RDP/ bUIlDIng DESIgnER I1.4 3.1 Construction Documents. The Construction Documents shall be prepared by a RDP/Building Designer and shall be of sufficient clarity to indicate the location, nature and extent of the work proposed, and show in detail that such documents conform to the Legal Requireb4.1 ments, including the Building Code. I1.4.1 Deferred Submittals. The RDP/Building Designer shall list the Deferred Submittals on the Construction Documents. The RDP/Building Designer shall review Deferred b4.2 Submittals. I1.4.2 Review of Submittal Packages. The RDP/Building Designer shall review the Truss Submittal Package for compatibility with the Building design. All such submittals shall include a notation indicating that they have been reviewed and whether or not they have been found to be in general conformance with the design of the Building for b4.3 final approval prior to truss fabrication. I1.4.3 Required Information in the Construction Documents. The RDP/Building Designer, through the Construction Documents, shall provide information sufficiently accurate and reliable to be used for facilitating the supply of the Structural Elements and other information for developing the design of the Trusses for the Building, b4.4 and shall provide the following: I1.4.4 (a) All Truss and Structural Element orientations and locations; (b) Information to fully determine all Truss profiles; 3.2 3.3 3.4 b4 This four-page publication offers a comprehensive approach to design responsibilities for cold-formed steel projects. Referencing language from AISI S202-11 and AISI S214-07/S2-08 Supplement 2, it lists responsibilities when legal requirements mandate a Registered Design Professional and when they do not. (4 pages) member non-member shipping lots of 25 PRICE EACH LOT PRICE EACH LOT units x qty. 1-9 10-19 20-99 100+ $22.50 21.50 20.50 19.50 $56.25 53.75 51.25 48.75 24 CFSWALL11X17-P Guide for Handling & Installing Cold-Formed Steel Wall Panels CFSB1 Spans over 60’ (18.3 m) may require complex permanent bracing. Please always consult a registered design professional. nOTaS gEnEraLES AISI S202-11 2.5 2.5.1 Copyright © 2012 STTTBDRESP-D 120221 4 This document summarizes the information provided in Section CFSB1 of the 2008 Edition of Cold-Formed Steel Building Component Safety Information CFSBCSI – Guide to Good Practice for Handling, Installing, Restraining & Bracing of Cold-Formed Steel Trusses. Copyright © 2008 Structural Building Components Association. All Rights Reserved. This guide or any part thereof may not be reproduced in any form without the written permission of the publisher. This document should appear in more than one color. Printed in the United States of America. Setting Trusses & Installation Restraint/Bracing For trusses up to 4'-0" (1.2 m) on-center and 80'-0" (24.4 m) in length The design responsibilities section of AISI S202-11 Code of Standard Practice for Cold-Formed Steel Structural Framing is included verbatim in AISI S21407 – North American Standard for Cold-Formed Steel Framing – Truss Design, which is referenced in the IBC and IRC. The following is a compilation of the requirements provided in AISI S202-11, with permission from the American Iron and Steel Institute, www.steel.org. The requirements are categorized into two distinct areas – when the legal requirements mandate a Registered Design Professional (RDP) is used and when they do not. Capitalized terms are in AISI S202-11 and CFSBCSI, Structural Building Component Information: Guide to Good Practice for Handling, Installing, Restraining & Bracing of Cold-Formed Steel Trusses. Corresponding sections from AISI S202-11 and AISI S214-07/ S2-08 are referenced in the following manner: DEFInITIOnS OF TERmS ARE AVAIlAblE In AISI S202-11 AnD CFSbCSI. Copyright © 2012 Structural Building Components Association, Madison, Wisconsin U.S.A. All rights reserved under International and Pan-American copyright conventions. Reproduction of this document, in any form, is prohibited without written permission from SBCA. This document should appear in more than one color. Depth, D CFSB2 2012 Edition PREAmblE 2.2 Structural building Components Association (SbCA) SUMMarY SHEET - gUiDE FOr HanDLing, inSTaLLing, rESTraining & BraCing OF TrUSSES – Spaced up to 4’-0” (1.2 m) on-center gEnEraL nOTES Trusses are not marked in any way to identify the Los trusses no están marcados de ningún modo que frequency or location of installation lateral restraint identifique la frecuencia o localización de restricción and diagonal bracing. Follow the recommendations lateral y arriostre diagonal temporales. Use las for handling, erecting and installation restraining recomendaciones de manejo, instalación, restricción y arriostre temporal de los trusses. Refiera a CFSBCSi and bracing of trusses. Refer to CFSBCSi – – Guía de Buena Práctica para el Manejo, Instalación, Guide to Good Practice for Handling, Installing, Restricción y Arriostre de los Trusses de Madera Restraining & Bracing of Cold-Formed Steel Conectados con Placas de Metal*** para información Trusses*** for more detailed information. más detallada. Truss Design Drawings may specify locations of permanent lateral restraint or reinforcement for Los Dibujos del Diseño de Truss pueden especificar individual truss members. Refer to the CFSBCSi- las ubicaciones de restricción lateral permanente B3*** for more information. All other permanent o refuerzo en los miembros individuales del truss. bracing design is the responsibility of the building Refiera a CFSBCSi-B3*** para más información. Todo el otro diseño del arriostre permanente es la designer. responsabilidad del diseñador del edificio. Standard Responsibilities in the Design and Application of Cold-Formed Steel Trusses These recommendations should not be interpreted as superior to the project Architect's or Engineer's design specification for handling, installing, restraining and bracing metal cold-formed steel trusses for a particular roof or floor. CFSJOBSITE-D Cold-Formed Steel Jobsite Package CFSB1 IN BUILDING HI Deferral to Construction Documents. AISI S202-11 is not intended to take precedence over the Construction Documents, where a Contract between parties incorporates by reference the Construction Documents, and therefore the Construction Documents shall apply as between the parties to the Contract. Deferral to Contract. AISI S202-11 is not intended to take precedence over a Contract as a Contract shall be permitted to contain provisions that take precedence over AISI S202-11 and/or the Construction Documents. A party shall not exclude in a Contract a responsibility established by AISI S202-11 or the Construction Documents unless that responsibility is assigned to a qualified party and that party agrees to HI that assignment. Any changes made to the Construction Documents by contract shall be submitted, reviewed and approved by the Building Official. Incorporation into Contract. A Contract shall be permitted to incorporate AISI S202-11 to establish the responsibilities of the parties to such Contract. shipping units x qty. 8.3 CFSDRESP-D Standard Responsibilities in the Design and Application of CFS Trusses shipping units x qty. 10 This 11"x17" guide for builders features proper techniques for unloading, storing, lifting, erecting and installing cold-formed steel (CFS) wall panels. It includes specific information for protecting wall panels from weather and damage at the jobsite, tips for lifting wall panels by hand or with a crane or forklift, installation bracing guidelines to prevent wall panels from toppling during erection, installation tolerances to keep the wall panels in plane and plumb, and basic construction loading and materials placement recommendations. Numerous graphics and ANSI standardized safety alert symbols accompanied by written instructions provide an easy-to-follow reference. lots of 100 1-4 5-10 11-20 21+ member non-member PRICE EACH LOT PRICE EACH LOT $60.00 56.00 54.00 52.00 $150.00 140.00 135.00 130.00 shipping units x qty. C O L D F O R M E D S T E E L P R O D U C T S 45 CFSQCWALLPROGRAM CFSC QC Wall Panel – Version 1.0 This program helps manufacturers monitor the quality of their wall panels and provides the plant with a data management system. It consists of inspecting wall panels and entering data into the software program, allowing you to store data and create reports to assess plant quality. Visit cfsc. sbcindustry.com/qcwall.php to learn more about implementing the program and becoming CFSC QC Wall Panel Certified. If your company has more than one plant, you may purchase additional copies of the most recent software program and manual for $170. Contact staff to receive this discount. quantity member PRICE EACH non-member PRICE EACH shipping units x qty. 1 Each Add’l $330.00 170.00 N/A 40 ORDER ONLINE AT sbcindustry.com/pubs 21 DRILL 20060409 www.tpinst.org plate Here WTCA – Representing the Structural Building Components Industry & Truss Plate Institute Copyright © 1992-2006 All Rights Reserved www.sbcindustry.com no altere madera de truss u lamInas sbr 20070109 www.tpinst.org PLATE HErE wtca – representing the structural building components industry & truss plate institute copyright © 1992-2007 all rights reserved www.tpinst.org PLate Here tOp CuMBRe Vea Dibujo De DiSeño De TruSS para información eSpecífica este LAdO pARA ARRiBA This tag emphasizes that trusses should not be cut or modified in any way. WTCA – Representing the Structural Building Components Industry & Truss Plate Institute TEMPBRACE 20070515 Copyright © 1992-2007 All Rights Reserved www.sbcindustry.com www.tpinst.org this side up See TruSS DeSign Drawing for Specific informaTion This tag complements the BCSI-B1 and BCSI-B2 Summary Sheets and indicates the need for temporary bracing. It assists in providing safety information to customers and also draws attention to the Summary Sheets, which give detailed information on how to install temporary bracing. Also available as a Cold-Formed Steel tag. TOP-T This Side Up (Purple) pLAte heRe Place this tag at the spot where a truss is to support a concentrated or point load. drill-T Do Not Cut, Drill or Alter (Blue) do not alter truss lumber or plates LOS trUSSeS SOn ineStaBLeS HaSta QUe Sean reStringidO Y arriOStradOS aPrOPiadaMente www.sbcindustry.com carGa concentrada aQUI cL 20060409 www.tpinst.org Plate here www.sbcindustry.com Vea Dibujo De DiSeño De TruSS para información eSpecífica ¡advertencia! Vea BCSI-B1 o BCSI-B2 para Información Sobre la Restricción y el Arriostre Temporal. Consulte el Diseñador de Edificio y BCSI-B3 para Información Sobre la Restricción y el Arriostre Permanente. Para Trusses Más de 60 Pies de Largo, Consulte a un Ingeniero Profesional. wTca – representing the Structural building components industry & Truss plate institute copyright © 1992-2006 all rights reserved See TruSS DeSign Drawing for Specific informaTion trUSSeS are UnStaBLe UntiL PrOPerLY reStrained & Braced See BCSI-B1 or BCSI-B2 for Temporary Restraint & Bracing Information. Consult Building Designer and BCSI-B3 for Permanent Restraint & Bracing Information. For Trusses 60' or Greater in Length, Consult a Professional Engineer. Top 20060409 Also available as a Cold-Formed Steel tag. warning! wTca – representing the Structural building components industry & Truss plate institute copyright © 1992-2006 all rights reserved Place this tag at points where additional or interior bearing supports should be located under the truss. CL-T Concentrated Load (Orange) concentrated load here This tag recommends the use of 2'x6' strongbacks at 10' o.c. It tells the installer to check the truss design drawing for more specific information. TEMPBRACE-T Temporary Bracing (Red & White) This tag reduces the chance that parallel chord trusses will be inadvertently installed upside down. WEBREINF-T Web Reinforcement (Aqua) WEB REINFORCEMENT REqUIRED See TruSS DeSign Drawing for Specific informaTion T, L or Scab reinforcemenT T, L o refuerZo De ScabS Vea Dibujo De DiSeño De TruSS para información eSpecífica REFUERZO DE MIEMBRO SECUNDARIO REqUERIDO webreinf 20060409 lUgar De coJinete Vea dibujo de diseño de truss para información específica www.tpinst.org VeA DIBujo De DISeño De TRuSS PARA InfoRmACIón eSPeCífICA CABALLETE dE "sTrongBACking" rECoMEndAdA PLATE HERE Plate Here See TRuSS DeSIgn DRAWIng foR SPeCIfIC InfoRmATIon see truss design drawing for specific information 2x6 strongback at 10' o.c. 2x6 espaLda fuerte en 10' o.c. wTca – representing the Structural building components industry & Truss plate institute copyright © 1992-2006 all rights reserved www.tpinst.org bearing location BL 20060409 BL-T Bearing Location (Red) sTrongBACking rECoMMEndEd www.sbcindustry.com This tag states that the truss has been designed to support heavier loads in this particular area (e.g., attic frame floor loads, rooftop mechanical units, storage loads, etc.). srb-T Strongback Bridging (Pink) www.sbcindustry.com Vea Dibujo De DiSeño De TruSS para información eSpecífica DISEÑADO PARA CARGA ADICIONAL aL 20060409 www.tpinst.org www.sbcindustry.com PLAtE HERE See TruSS DeSign Drawing for Specific informaTion wTca – representing the Structural building components industry & Truss plate institute copyright © 1992-2006 all rights reserved DESIGNED fOR ADDItIONAL LOADING WTCA – Representing the Structural Building Components Industry & Truss Plate Institute Copyright © 1992-2006 All Rights Reserved T A G S AL-T Additional Loading (Yellow) www.sbcindustry.com T R U S S This tag identifies particular webs that require web reinforcement, such as T-Bracing. FAll-T Fall Protection (White & Black) This tag warns that trusses by themselves are NOT to be used as fall protection anchors and refers the installer to BCSI-B11 for more information on fall protection issues. cfsBL-T Bearing Location JOBSITE 20060409 www.tpinst.org PLate Here WTCA – Representing the Structural Building Components Industry & Truss Plate Institute Copyright © 1992-2006 All Rights Reserved ¡advertencia! Antes de mover, guardar o instalar los componentes vea la Hoja Sumaria del BCSI y los materiales incluidos en el PAQUETE DE OBRA del fabricante de componentes. www.sbcindustry.com WarninG! Before handling, storing or installing components refer to BCSI Summary Sheet(s) and materials provided in the component manufacturer’s JOBSITE PACKAGE. Also available as a Cold-Formed Steel tag. Abroche trusses juntos de acuerdo con el dibujo de diseño de truss, antes de erectar cuando sea posible. Inspecte todas las conecciones. (no De una Capa) este truss es De Varias Capas www.sbcindustry.com plate here Fasten trusses together according to Truss Design Drawing, prior to erecting whenever possible. Inspect all connections. MPT 20070109 (not single ply) WTCA – Representing the Structural Building Components Industry & Truss Plate Institute Copyright © 1992-2007 All Rights Reserved this is a multi-ply truss www.tpinst.org MPT-T Multi-Ply Truss (Gold) DIAGONAL BRACING VEA EL DIBUJO DE DISEÑO DE TRUSS PARA RESTRICCIÓN LATERAL; CONSULTE AL DISEÑADOR DE EDIFICIO Y/O BCSI-B3 PARA ARRIOSTRE DIAGONAL 22 RESTRICCIÓN LATERAL PERMANENTE Y ARRIOSTRE DIAGONAL ES REQUERIDO 2016 PLB 20100304 www.tpinst.org PLATE HERE LATERAL RESTRAINT Structural Building Components Association & Truss Plate Institute Copyright © 1992-2010 All Rights Reserved NOTE: WEB MEMBER REINFORCEMENT MAY ALSO BE POSSIBLE; SEE BCSI-B3 SEE TRUSS DESIGN DRAWING FOR LATERAL RESTRAINT; CONSULT BUILDING DESIGNER AND/OR BCSI-B3 FOR DIAGONAL BRACING www.sbcindustry.com PERMANENT LATERAL RESTRAINT & DIAGONAL BRACING REQUIRED This tag indicates that one or two lateral braces may be required on the tagged member and instructs the installer to look for more information on the truss design drawing and BCSI-B3. 25 SEE TRUSS DESIGN DRAWING FOR LATERAL RESTRAINT; CONSULT BUILDING DESIGNER AND/OR CFSBCSI-B3 FOR DIAGONAL BRACING LATERAL RESTRAINT DIAGONAL BRACING Vea DiBujo De DiSeño De TruSS para información eSpecífica lUgar De coJinete www.sbcindustry.com VEA EL DIBUJO DE DISEÑO DE TRUSS PARA RESTRICCIÓN LATERAL; CONSULTE AL DISEÑADOR DE EDIFICIO Y/O CFSBCSI-B3 PARA ARRIOSTRE DIAGONAL # wTca – representing the Structural Building components industry copyright © 2007 all rights reserved www.cfsc.sbcindustry.com RESTRICCIÓN LATERAL PERMANENTE Y ARRIOSTRE DIAGONAL ES REQUERIDO www.sbcindustry.com cfsjobsite-t Jobsite Warning Before handling, storing or installing components refer to CFSBCSI Summary Sheet(s) and materials provided in the component manufacturer’s JOBSITE PACKAGE. www.sbcindustry.com ¡ADVERTENCIA! Antes de mover, guardar o instalar los componentes, vea la(s) Hoja(s) Sumaria(s) del CFSBCSI y los materiales incluidos en el PAQUETE DE OBRA del fabricante de componentes. # WTCA – Representing the Structural Building Components Industry Copyright © 2007 All Rights Reserved # WTCA – Representing the Structural Building Components Industry Copyright © 2007 All Rights Reserved www.cfsc.sbcindustry.com cfsINSTBRACE-t Installation Restraint & Bracing www.cfsc.sbcindustry.com warning! TRUSSES ARE UNSTABLE UNTIL PROPERLY RESTRAINED & DIAGONALLY BRACED See CFSBCSI-B1 or CFSBCSI-B2 for Installation Restraint & Diagonal Bracing Information. Consult Building Designer and/or CFSBCSI-B3 for Permanent Restraint & Diagonal Bracing Information. For Trusses 60' or Greater in Length, Consult a Professional Engineer. ¡advertencia! LOS TRUSSES SON INESTABLES HASTA QUE SEAN RETRINGIDOS Y ARRIOSTRADOS DIAGONALMENTE APROPIADAMENTE Vea CFSBCSI-B1 o CFSBCSI-B2 para Información Sobre la Restricción de Instalación y Arriostre Diagonal. Consulte al Diseñador del Edificio y/o CFSBCSI-B3 para Información Sobre la Restricción Permanente y el Arriostre Diagonal. Para Trusses de Más de 60 Pies de Largo, Consulte a un Ingeniero Profesional. www.sbcindustry.com PLB-T Permanent Lateral Bracing (Green) $68.00 64.50 61.00 PERMANENT LATERAL RESTRAINT AND DIAGONAL BRACING REQUIRED WARNING! This tag emphasizes that the truss is not to be used independently and refers the installer to the truss design drawing for multi-ply laminating instructions. $40.00 38.00 36.00 CFSPLRB-T Permanent Lateral Restraint & Diagonal Bracing bearing location This tag warns to refer to instruction material for proper handling, storing and bracing information. 1-6 7-49 50+ STEEL TRUSS TAGS See TruSS DeSign Drawing for Specific informaTion JOBSITE-T Jobsite Warning (Red & White) member non-member shipping PRICE EACH lot PRICE EACH lot units x qty. lots of 1000 # WTCA – Representing the Structural Building Components Industry Copyright © 2007 All Rights Reserved www.cfsc.sbcindustry.com cfsDC-t Do Not Use Damaged Components This tag warns against using components that are damaged or altered. DO NOT USE DAMAGED COMPONENTS DO NOT USE CUT, BENT OR OTHERWISE DAMAGED COMPONENTS lots of 500 NO USE LOS COMPONENTES CORTADOS, DOBLADOS O DE OTRA MANERA DAÑADOS NO USE LOS COMPONENTES DAÑADOS www.sbcindustry.com # WTCA – Representing the Structural Building Components Industry Copyright © 2007 All Rights Reserved www.cfsc.sbcindustry.com 1-5 6-10 11+ member non-member shipping PRICE EACH lot PRICE EACH lot units x qty. $48.00 43.00 38.00 $120.00 107.50 95.00 20 Also available as a Cold-Formed Steel tag. ORDER ONLINE AT sbcindustry.com/pubs 2016 Instructions: (Photocopy this page to use with future orders) For each product you want to order: SHIPPING & HANDLING (SHIPPING UNITS) CONTINENTAL U.S. ORDERS ONLY 1.Enter the Product Code (A), Quantity (B), Price Per Item (C) and Shipping Units (D). 2.For all products, multiply Quantity (B) by Price Per Item (C) to get the Extended Price (E). 3. Multiply the Quantity (B) by Shipping Units Per Item (D) to get Extended Shipping Units (F). SHIPPING UNITS To calculate totals: 4.Subtotal the Extended Prices (E) and the Extended Shipping Units (F) columns. 5. ONLY FOR ORDERS DELIVERED TO WISCONSIN: Calculate WI Sales Tax by multiplying your Subtotal by the appropriate tax amount–5.5%, 5.6%, etc. 6.To calculate Shipping & Handling, find your Total Extended Shipping Units in the first column of the Shipping & Handling chart. Total Shipping & Handling will be the amount shown in the middle or right column, if you are a member or non-member, respectively. Place this amount in Shipping & Handling. Please note: all shipping charges are subject to adjustment. *If you are located outside the CONTINENTAL U.S., your shipping charge will increase. please contact SBCA Staff for shipping and handling. 7.Calculate the Order Total by adding the Subtotal, WI Sales Tax (if applicable), and Shipping & Handling. 8.Add $3.00 for Residential Deliveries. 9. Make checks payable to: SBca They’re your golden defense. 1-39 40-79 80-129 130-179 180-239 240-289 290-349 350-409 410-469 470-529 530-599 600-659 660+ MEMBER NONMEMBER 18.00 21.00 22.00 26.00 24.00 30.00 26.00 36.00 29.00 40.00 33.00 45.00 39.00 52.00 44.00 60.00 51.00 70.00 57.00 79.00 64.00 90.00 69.00 102.00 CONTACT SBCA FOR DELIVERY TIME OF LESS THAN TWO WEEKS, PLEASE CALL SBCA. ADDITIONAL HANDLING FEES MAY APPLY. PRICES SUBJECT TO CHANGE WITHOUT NOTICE. (A) Product Code (B) Quantity or Lots (C) Price (D) Shipping Units (B) x (C) = (E) Extended Price (B) x (D) = (F) Extended Shipping Units Follow the industry’s best practices. Subtotal: “Being able to doccument that a JOBSITE PACKAGE was duly received by your customer and the truss erector is a risk management tool that can provide significant protection to component manufacturers.” Kent Pagel SBCA Legal Counsel WI Sales Tax: NOTE: BUILDING OFFICIALS, FIRE OFFICIALS, ARCHITECTS & ENGINEERS USE LOWEST PRICING Shipping & Handling (Continental U.S. Only*): Residential Delivery Add $3.00: Shipping Address (No P.O. Boxes) City, State, Zip Is this a residential delivery? Yes No Your Name JOBSITE PACKAGES are available for wood, cold-formed steel, long span trusses, floor trusses and wall panels. To learn more or order, visit sbcindustry.com/jobsite. 6300 Enterprise Lane Madison, WI 53719 608-274-4849 phone 608-274-3329 fax sbcindustry.com Telephone (Area Code) Name that appears on credit card (please print) VISA/MC/AmEx Number Credit Card Billing Address Send me information about new publications & specials. Email Address (for automated shipping notification) F O R M F O R & TOTAL: Company Place your order online at sbcindustry.com/pubs IT'S FAST AND SIMPLE! (or fax to 608-274-3329) O R D E R P R O D U C T S Educate your customers. Protect your company. Boost your commitment to safety. S B C A Purchase Order Number (if required) Signature Verification Code Exp. Date S E R V I C E S Protect Your Company Build a Strong Team STRUCTURAL BUILDING COMPONENTS ASSOCIATION Measure Progress Educate Your Staff Two SCORE Designations Are Available to Participants: SCORE Member The plant is a member in good standing with a year to work toward SCORE certification and has purchased the following either individually or as a package: ■ Access to TTT for all truss designers. ■ Access to SBCA’s online QC program. ■ Jobsite Packages, which are sent with every truss delivery. Simplified Certifications ■ Centered on programs that matter most to CMs’ customers. SCORE Certified The plant is a member in good standing and is compliant with all items below: ■ Streamlined certification requirements and quality focused. ■ ■ ■Simplified designations available: SCORE Certified or a SCORE Member working toward certification. ■ ■ ■ Members who are working toward SCORE certification start reaping the benefit of their efforts immediately. ■ ■ New Simplified Requirements ■ Continuing Education: Plant fulfills ongoing TTT requirements. J obsite Packages: Plant purchases and sends with every truss delivery. Plant Tour: Plant hosts one plant tour or similar event per year. C Certification: Plant is SBCA QC certified and continues to Q submit quarterly data files for SBCA review. afety Certification: Plant meets safety program requirements, S either with SBCA Operation Safety or a program reviewed and approved by SBCA staff. TT Certification: Average TTT level for CM designers at a location T must be 1.5 or higher. Quality-Focused ■ Customer-Centered ■ Best Practices 2016 PRODUCTS&PROGRAMS Order online at sbcindustry.com/pubs
Documentos relacionados
BCSI – Guide to Good Practice for Handling - Support Home
BCSI possible: Scott Arquilla; Rich Avery; Bruce Bain; Paul Bartholomew; Dave Brakeman, P.E., S.E.; Junaidie Budiman, P.E.; Mike Bugbee; Steve Cabler, P.E.; Mike Cassidy, R.A.; Steve Cramer, P.E.; ...
Más detalles