cooling units condizionatori kühlgeräte climatiseurs climatizadores
Transcripción
cooling units condizionatori kühlgeräte climatiseurs climatizadores
COOLING UNITS CONDIZIONATORI KÜHLGERÄTE CLIMATISEURS CLIMATIZADORES Partnership and know-how: the key to an exceptional result I.CO.S Srl was established in 2009 as a design and R&D centre in cooling applications for industrial power and control cabinets. I.CO.S is a collaboration between a variety of companies with more than 20 years experience in the design, fabrication and marketing of industrial refrigeration products. The company’s management, composed of persons with enormous experience of industrial refrigeration, has instituted collaborations with large international companies. The result of our synergy with Far Eastern companies is the development of a new, fully featured range of power cabinet cooling units, designed in Europe but assembled in our Chinese partner’s plant, thus combining the knowhow gained in twenty years experience of the European market with the renowned low production costs of the Far East. This ambitious project has been a complete success. Our rigorous product testing to EN814 (DIN3168) and certification to applicable EN standards (CE, EMC, PED) - all done in Europe - are a guarantee of conformity in every detail. Our attention to this essential aspect enable us to offer products which meet the market’s needs with the highest quality available. Our high tech partner has been operating since the early Nineties as a manufacturer of electrical cabinet conditioning and industrial refrigeration solutions and, with an output of tens of thousands of units a year, is one of the largest Chinese industrial groups - the ideal partner for assuring the production levels and product quality required for the European market. Their large assembly lines are equipped with high level quality controls to satisfy the requirements of the European marketplace. I.CO.S also has staff on site to supervise production, packaging and shipping, along with product testing, to ensure the best quality for our customers. Our ICS and ICR series are optimised and industrialised for intensive production with an eye to the requirements of the major European machine tool and automation manufacturers. I.CO.S products are the ideal solution to the challenges of an ever more competitive market, and offer unbeatable value for money. 3 Partnership e know-how: il segreto di un risultato sorprendente Partnerschaft und Know-how: Das Geheimnis eines überraschenden Erfolgs I.CO.S Srl è stata fondata nell’anno 2009 quale polo di progettazione, ricerca e sviluppo per il settore del raffreddamento dei quadri elettrici industriali di comando e controllo. Sono confluite in I.CO.S un pool di aziende specializzate da oltre 20 anni, nella lavorazione meccanica, progettazione e vendita di prodotti dedicati al settore della refrigerazione industriale. La direzione aziendale, composta di persone dotate di grande esperienza nel settore della refrigerazione industriale, ha portato alla nascita di collaborazioni con grandi realtà del panorama internazionale. Il risultato della sinergia con aziende del far-east è stata la nascita di un nuovo e completo range di Condizionatori per Quadri Elettrici, progettati interamente in Europa ma assemblati negli stabilimenti di un partner cinese, coniugando il know-how e l’esperienza accumulati in 20 anni di presenza sul mercato europeo, con la nota produttività a costi contenuti propria dell’area del far-east. La finalità di questo importante progetto è stata soddisfatta dal risultato conseguito. Dalla rigidità dei test effettuati sul prodotto, che ne attestano le prestazioni secondo la norma EN814 (DIN3168), alla certificazione alle normative EN applicabili (CE, EMC, PED), interamente effettuata in Europa, ne garantiscono una conformità nei minimi dettagli. L’attenzione posta a questi delicati aspetti ha permesso di conseguire un importante risultato, la capacità di soddisfare le esigenze del mercato offrendo il massimo livello di qualità. Il partner high-tech, scelto da I.CO.S, è presente sul mercato dai primi anni ‘90, come produttore di apparecchiature per il condizionamento degli armadi elettrici e la refrigerazione industriale che, con una produzione annua di decine di migliaia di unità, si attesta tra i maggiori gruppi industriali cinesi; partner ideale per assicurare la capacità produttiva e la qualità dei prodotti necessarie per servire l’intero mercato europeo. L’affidabilità dei prodotti usciti dalle imponenti linee produttive, è assicurata da un controllo qualità di alto livello adeguati agli standard europei. I.CO.S inoltre è presente in loco, con propri funzionari che supervisionano le linee produttive, gli imballaggi e le spedizioni, i test effettuati su i prodotti per garantire al cliente europeo l’ottima qualità del prodotto offerto. I prodotti della serie ICS ed ICR sono ottimizzati ed industrializzati per una produzione intensiva atta a soddisfare le necessità dei maggiori produttori di macchine utensili ed automatiche europei. Die Firma I.CO.S Srl wurde 2009 als Konstruktions-, Forschungs- und Entwicklungspool für den Bereich der Kühlung von industriellen Schalt- und Steuerschränken gegründet. Der Firma I.CO.S hat sich eine Gruppe von Unternehmen angeschlossen, die sich seit mehr als 20 Jahren auf die mechanische Bearbeitung, die Konstruktion und den Verkauf von Produkten für die industrielle Kühlung spezialisiert haben. Die Unternehmensleitung, die sich aus Fachleuten zusammensetzt, die über eine große Erfahrung im Bereich der industriellen Kältetechnik verfügen, hat die Zusammenarbeit mit wichtigen internationalen Unternehmen vorangetrieben. Das Resultat der Synergie mit Unternehmen des Fernen Ostens ist eine neue und umfassende Baureihe von Kühlgeräten für Schaltschränke, die vollständig in Europa geplant, aber in den Werken eines chinesischen Partners montiert werden, so dass das in 20 Jahren auf dem europäischen Markt erworbene Know-how mit der bekannten kostengünstigen Produktivität des Fernen Ostens verbunden werden. Dieses bedeutende Projekt hat seine Zielsetzungen voll und ganz erfüllt. Die strengen Prüfungen der Produkte, die ihre Leistungen gemäß der Norm EN 814 (DIN3168) bescheinigen, und die gänzlich in Europa vorgenommene Zertifizierung nach den einschlägigen europäischen Bestimmungen (CE, EMC, PED) garantieren ihre Konformität bis ins kleinste Detail. Das große Gewicht, das auf diese heiklen Aspekte gelegt wurde, gestattete es, ein wichtiges Ziel zu erreichen, nämlich die Nachfrage auf höchstem qualitativen Niveau zu bedienen. Der von I.CO.S gewählte High-Tech-Partner ist seit den frühen neunziger Jahren als Hersteller von Geräten für die Kühlung von Schaltschränken und für die industrielle Kühlung auf dem Markt tätig. Mit seiner Jahresproduktion von zehntausenden Einheiten gehört er zu den wichtigsten chinesischen Industriegruppen; ein idealer Partner, um die Produktionskapazität und die Produktqualität zu gewährleisten, die erforderlich sind, um den ganzen europäischen Markt zu bedienen. Die Zuverlässigkeit der Produkte, welche die beeindruckenden Produktionsanlagen verlassen, wird durch die hochwertige Qualitätskontrolle nach den europäischen Standards garantiert. I.CO.S ist außerdem mit eigenem Personal vor Ort vertreten, das die Produktionsanlagen, die Verpackung, den Versand und die Prüfungen der Produkte überwacht, um dem europäischen Kunden die optimale Qualität des angebotenen Produkts zu garantieren. Die Produkte der Serien ICS und ICR sind für eine intensive Produktion optimiert und industrialisiert, um den Erfordernissen der wichtigsten europäischen Hersteller von Werkzeugmaschinen und automatischen Maschinen gerecht zu werden. Scegliere i prodotti I.CO.S per affrontare le sfide di un mercato sempre più competitivo è la risposta corretta in termini di rapporto qualità/prezzo. Die Wahl der Produkte von I.CO.S ist allein schon in Hinblick auf das Preis-Leistungs-Verhältnis die richtige Entscheidung, um sich den Herausforderungen eines immer kompetitiveren Markts zu stellen. 4 Partnership e know-how : le secret d’un résultat original Colaboración y know-how: el secreto de un resultado sorprendente I.CO.S Srl, fondée en 2009, est un pôle de conception de projet, de recherche et développement dans le secteur du refroidissement des tableaux électriques de commande et de contrôle industriels. I.CO.S est la convergence d’un ensemble d’entreprises spécialisées depuis plus de 20 ans dans la réalisation mécanique, la conception de projet et la vente de produits consacrés au secteur de la réfrigération industrielle. La direction de l’entreprise est composée de personnes ayant une grande expérience dans ce secteur et qui ont donné naissance à des collaborations très concrètes sur le plan international. Le résultat de la synergie avec des entreprises d’ExtrêmeOrient a donné jour à une toute nouvelle gamme complète de Climatiseurs de Tableaux Electriques, conçus entièrement en Europe mais assemblés dans les usines d’un partenaire chinois, conjuguant ainsi le savoir-faire acquis par 20 ans de présence sur le marché européen, avec la productivité à coûts réduits qui fait la renommée de la région asiatique. La finalité de ce projet important a été satisfaite par le résultat obtenu. La rigueur des tests effectués, qui en atteste les performances conformément à la norme EN814 (DIN3168), ainsi que la certification aux normes EN applicables (CE, EMC, PED), intégralement effectuée en Europe, garantissent la conformité du produit dans les moindres détails. L’attention portée à ces aspects délicats a permis d’obtenir un résultat important, la capacité de satisfaire les exigences du marché tout en offrant un niveau de qualité optimal. Le partenaire high-tech, choisi par I.CO.S, est présent sur le marché depuis le début des années 1990, en tant que producteur d’appareils pour la climatisation des armoires électriques et la réfrigération industrielle qui, avec une production annuelle de dizaines de milliers d’unités, s’impose dans les principaux groupes industriels chinois. Partenaire idéal pour garantir la capacité productive et la qualité des produits nécessaires pour desservir tout le marché européen. La fiabilité des produits sortis des imposantes chaînes de production, est assurée par un contrôle qualité de haut niveau adapté aux normes européennes. En outre, I.CO.S est présente localement, avec ses propres cadres pour superviser les chaînes de production, les emballages et l’expédition, ainsi que les tests effectués sur les produits, pour garantir au client européen une qualité optimale. Les produits des séries ICS et ICR sont optimisés et industrialisés pour une production intensive apte à satisfaire les besoins des principaux fabricants européens de machines-outils et automatiques. I.CO.S Srl fue fundada en el año 2009 como polo de diseño, investigación y desarrollo para el sector de la refrigeración de los cuadros eléctricos de mando y control. En I.CO.S confluyó un pool de empresas especializadas desde hace más de veinte años en la mecanización, diseño y venta de productos dedicados al sector de la refrigeración industrial. La dirección de la empresa, compuesta por personas dotadas de gran experiencia en el sector de la refrigeración industrial, ha llevado a la gestación de colaboraciones con grandes realidades del panorama internacional. El resultado de la sinergia con empresas del Far-East ha sido la creación de un nuevo y completo rango de climatizadores para cuadros eléctricos, diseñados enteramente en Europa pero ensamblados en los establecimientos de un partner chino, conjugando la experiencia y el know-how acumulados en veinte años de presencia en el mercado europeo con la ya conocida productividad a costes limitados, propia del área del Far-East. La finalidad de este importante proyecto ha sido alcanzada gracias al resultado obtenido. De la rigurosidad de los tests efectuados sobre el producto, que acreditan sus prestaciones según la norma EN814 (DIN3168), a la certificación conformemente con lo establecido por las normativas EN aplicables (CE, EMC, PED), enteramente efectuada en Europa, garantizan una conformidad hasta en los más mínimos detalles. La atención prestada a estos delicados aspectos ha permitido obtener un importante resultado, esto es, la capacidad de satisfacer los requerimientos del mercado ofreciendo el nivel máximo de calidad. El partner de alta tecnología elegido por I.CO.S está presente en el mercado desde principios de los años 90 como productor de aparatos para la climatización de los armarios eléctricos y la refrigeración industrial que - con una producción anual de decenas de miles de unidades - se sitúa entre los mayores grupos industriales chinos, partner ideal para garantizar la capacidad productiva y la calidad de los productos, necesarias para servir al mercado europeo en su conjunto. La fiabilidad de los productos que salen de las imponentes líneas productivas queda garantizada por un control de calidad de alto nivel, según los estándares europeos. Además, I.CO.S está presente en el lugar con sus propios funcionarios que supervisan las líneas productivas, los embalajes y los envíos, así como los tests efectuados sobre los productos, a fin de garantizar al cliente europeo calidad optimizada del producto ofrecido. Los productos de las series ICS e ICR son optimizados e industrializados para una producción intensiva, adecuada para satisfacer los requerimientos de los mayores productores europeos de máquinas herramientas y máquinas automáticas. Choisir les produits I.CO.S pour faire face aux défis d’un marché chaque jour plus concurrentiel est la réponse adaptée en termes de rapport qualité/prix. Elegir los productos I.CO.S para enfrentar los desafíos de un mercado cada vez más competitivo es la respuesta adecuada en términos de relación calidad/precio. 5 EN IT D FR ES pag 9 COOLING UNITS pag 25 CONDIZIONATORI pag 41 KÜHLGERÄTE pag 57 CLIMATISEURS pag 73 CLIMATIZADORES 7 ICS series cooling units ICS series cooling units are ready-to-use units for installation to the cabinet door or wall. The front grille can house an optional removable and washable air filter, while the 1:1 drilling template, bolts and rubber hose with integral fitting and clamp are included in the package. Hookup is done with a supplied rapid connector (requires cabling). The cooling unit is equipped with an electronic controller, complete with condensation tank and emergency drain (connects with a rubber hose during installation). ICR series cooling units ICR series cooling units are ready-to-use cabinet-top units. The front grille can house an optional removable and washable air filter, while the 1:1 drilling template, bolts and rubber hose with integral fitting and clamp are included in the package. Hookup is done with a supplied rapid connector (requires cabling). The cooling unit is equipped with an electronic controller, complete with condensation tank and emergency drain (connects with a rubber hose during installation). Electronic controller functions The electronic thermostat with which ICS and ICR models are equipped has the following standard characteristics: • Cabinet temperature display • Cabinet temperature setpoint adjustment • Password protected configuration settings • Compressor activation delay • Maximum temperature alarm • Antifreeze alarm • Condenser dirty alarm • Water tank level alarm for ICR cabinet-top models • Alarm buzzer (with OFF button) • Evaporator side fan self-test • Door switch to stop cooling unit (programmable: can be disabled if not required) • Alarm diagnostics with led error message display 8 EN COOLING UNITS pag 10 COOLING UNITS pag 22 USING I.CO.S COOLING UNITS 9 EN Wall-mounted cooling units ICS 035-380 W ICS 035 50 / 60 Hz Cooling power (L35; L35) W 380 / 420 Cooling power (L35; L50) W 189 / 226 Nominal power absorption (L35; L50) W 350 / 391 Nominal maximum current A 1,5 / 1,7 Ambient temperature °C 20 - 55 Evaporator fan Type Axial Number of poles p 2 Speed rpm 2600 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 16 Dimensions mm 170 x 286 x 525 H Internal/external protection rating IP 54/34 Noise level dB(A) 61 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 440 400 380 143 55 ø154 210 50 270 35 170 30 16 80 35 25 120 20 25 30 35 40 45 50 20 ∅ Ambient temperature °C 77 10 38 50 40 525 420 45 220 13 277 470 13 97 520 286 260 50 570 Cabinet temperature °C Cooling power W Output diagram EN Wall-mounted cooling units ICS 050-500 W ICS 050 50 / 60 Hz Cooling power (L35; L35) W 500 / 575 Cooling power (L35; L50) W 272 / 312 Nominal power absorption (L35; L50) W 350 / 391 Nominal maximum current A 1,6 / 1,7 Ambient temperature °C 20 - 55 Evaporator fan Type Axial Number of poles p 2 Speed rpm 2600 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 17 Dimensions mm 170 x 286 x 525 H Internal/external protection rating IP 54/34 Noise level dB(A) 61 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 660 580 500 143 55 ø154 210 50 420 35 260 30 16 80 35 25 180 20 25 30 35 40 45 50 38 50 350 525 420 45 40 13 97 730 13 277 820 286 260 50 900 Cabinet temperature °C Cooling power W Output diagram 20 ∅ Ambient temperature °C 77 11 EN Wall-mounted cooling units ICS 080-800 W ICS 080 50 / 60 Hz Cooling power (L35; L35) W 800 / 920 Cooling power (L35; L50) W 560 / 645 Nominal power absorption (L35; L50) W 546 / 621 Nominal maximum current A 2,5 / 2,7 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 27 Dimensions mm 210 x 350 x 630 H Internal/external protection rating IP 54/34 Noise level dB(A) 60 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 350 1050 1000 920 865 52.5 245 52.5 175 115 1120 65 1190 800 365 1250 Cabinet temperature °C Cooling power W Output diagram Ø160 735 55 670 68 40 503 45 540 630 50 600 35 480 35 25 20 25 30 35 40 45 40 270 30 410 ∅ 50 20 Ambient temperature °C 67 12 80 50 EN Wall-mounted cooling units ICS 100-1100 W ICS 100 50 / 60 Hz Cooling power (L35; L35) W 1100 / 1210 Cooling power (L35; L50) W 1000 / 1100 Nominal power absorption (L35; L50) W 568 / 644 Nominal maximum current A 2,6 / 2,8 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 30 Dimensions mm 210 x 350 x 630 H Internal/external protection rating IP 54/34 Noise level dB(A) 60 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 350 1200 1150 245 Ø160 1100 55 1090 52.5 175 115 1300 52.5 65 1500 365 1700 Cabinet temperature °C 40 68 45 1050 503 50 630 Cooling power W Output diagram 35 900 30 500 35 20 20 25 30 35 40 45 40 270 25 ∅ 50 Ambient temperature °C 67 80 50 13 EN Wall-mounted cooling units ICS 130-1250 W ICS 130 50 / 60 Hz Cooling power (L35; L35) W 1250 / 1430 Cooling power (L35; L50) W 1070 / 1230 Nominal power absorption (L35; L50) W 699 / 828 Nominal maximum current A 3,2 / 3,6 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 40 Dimensions mm 235 x 370 x 855 H Internal/external protection rating IP 54/34 Noise level dB(A) 68 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 370 1700 1570 1470 15 185 340 1360 Ø160 1250 1140 15 136.5 1790 86.5 1900 550 Cabinet temperature °C Cooling power W Output diagram 45 920 689 50 855 55 1100 55 260 40 85 35 820 30 25 30 35 40 Ambient temperature °C 45 50 20 35 25 20 16 80 155 700 ∅ 14 EN Wall-mounted cooling units ICS 150-1580 W ICS 150 50 / 60 Hz Cooling power (L35; L35) W 1580 / 1740 Cooling power (L35; L50) W 1150 / 1265 Nominal power absorption (L35; L50) W 765 / 920 Nominal maximum current A 3,5 / 4,0 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2400 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 43 Dimensions mm 235 x 370 x 855 H Internal/external protection rating IP 54/34 Noise level dB(A) 73 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 370 1950 1800 1650 15 185 340 15 136.5 2100 86.5 2250 Ø160 1500 550 Cabinet temperature °C 1200 55 50 1050 45 689 1350 855 55 260 85 40 900 35 25 20 25 30 35 40 Ambient temperature °C 45 50 20 35 30 750 16 80 155 Cooling power W Output diagram ∅ 15 EN Wall-mounted cooling units ICS 200-2000 W ICS 200 50 / 60 Hz Cooling power (L35; L35) W 2000 / 2300 Cooling power (L35; L50) W 1380 / 1590 Nominal power absorption (L35; L50) W 1035 / 1219 Nominal maximum current A 4,5 / 5,3 Ambient temperature °C 20 - 50 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2450 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2500 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 62 Dimensions mm 280 x 435 x 1160 H Internal/external protection rating IP 54/34 Noise level dB(A) 63 Power supply V Ph Hz 220-240V/1/50-60 Hz Output diagram Mounting template Cabinet temperature °C 2900 2600 395 20 217.5 Ø180 780 2300 25 145 3200 370 Cooling power W 435 20 2000 ∅ 1700 45 1100 35 1160 50 1400 400 55 80 40 300 125 30 25 20 25 30 35 40 45 50 20 350 800 35 90 Ambient temperature °C 16 80 30 EN Wall-mounted cooling units ICS 250-2600 W ICS 250 50 / 60 Hz Cooling power (L35; L35) W 2600 / 2860 Cooling power (L35; L50) W 1730 / 1900 Nominal power absorption (L35; L50) W 1478 / 1932 Nominal maximum current A 6,7 / 8,4 Ambient temperature °C 20 - 50 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2600 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2500 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 63 Dimensions mm 280 x 435 x 1160 H Internal/external protection rating IP 54/34 Noise level dB(A) 63 Power supply V Ph Hz 220-240V/1/50-60 Hz Output diagram Mounting template Cabinet temperature °C 20 Ø180 780 3000 395 217.5 145 3500 25 370 4000 2500 ∅ 50 2000 45 400 55 1160 40 80 35 1500 300 125 30 25 20 1000 25 30 35 40 45 50 35 80 30 Ambient temperature °C 90 20 350 Cooling power W 435 20 17 EN Wall-mounted cooling units ICS 350-3500 W ICS 350 50 / 60 Hz Cooling power (L35; L35) W 3500 / 3850 Cooling power (L35; L50) W 2230 / 2470 Nominal power absorption (L35; L50) W 1613 / 2093 Nominal maximum current A 7,3 / 9,1 Ambient temperature °C 20 - 50 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2500 Isolation class B Condenser fan Type Centrifugal Number of poles p 2 Speed rpm 2500 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 62 Dimensions mm 280 x 435 x 1230 H Internal/external protection rating IP 54/34 Noise level dB(A) 73 Power supply V Ph Hz 220-240V/1/50-60 Hz Output diagram Mounting template Cabinet temperature °C 4050 198 4600 20 217.5 65 5150 395 20 400 Cooling power W 435 5700 Ø210 876 3500 55 2950 ∅ 40 400 45 2400 1230 50 35 318 120 25 25 30 35 40 Ambient temperature °C 45 50 80 90 35 20 350 20 1300 18 75 30 1860 30 EN Top-mounted cooling units ICR 150-1450 W ICR 150 50 / 60 Hz Cooling power (L35; L35) W 1450 / 1670 Cooling power (L35; L50) W 740 / 850 Nominal power absorption (L35; L50) W 808 / 989 Nominal maximum current A 3,7 / 4,3 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2500 Isolation class B Condenser fan Type Axial Number of poles p 4 Speed rpm 1420 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 62 Dimensions mm 480 x 595 x 400 H Internal/external protection rating IP 54/34 Noise level dB(A) 63 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 595 Cabinet temperature °C 1800 1650 1500 195 225 100 40 20 175 1950 35 43 2100 370 2250 480 Cooling power W Output diagram 1350 1200 55 50 1050 45 ∅ 40 900 35 30 750 20 25 30 35 40 45 22.5 550 25 50 20 Ambient temperature °C 19 EN Top-mounted cooling units ICR 170-1700 W ICR 170 50 / 60 Hz Cooling power (L35; L35) W 1700 / 1870 Cooling power (L35; L50) W 1080 / 1190 Nominal power absorption (L35; L50) W 816 / 1012 Nominal maximum current A 3,7 / 4,4 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2600 Isolation class B Condenser fan Type Axial Number of poles p 4 Speed rpm 1420 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 64 Dimensions mm 480 x 595 x 400 H Internal/external protection rating IP 54/34 Noise level dB(A) 63 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 595 480 1980 1700 1450 195 225 100 40 20 175 2300 35 43 2590 370 2870 Cabinet temperature °C Cooling power W Output diagram 55 50 45 1150 35 30 870 20 25 30 35 40 Ambient temperature °C 20 ∅ 40 45 25 50 20 22.5 550 EN Top-mounted cooling units ICR 230-2300 W ICR 230 50 / 60 Hz Cooling power (L35; L35) W 2300 / 2530 Cooling power (L35; L50) W 1330 / 1460 Nominal power absorption (L35; L50) W 1026 / 1265 Nominal maximum current A 4,7 / 5,5 Ambient temperature °C 20 - 55 Evaporator fan Type Centrifugal Number of poles p 2 Speed rpm 2600 Isolation class B Condenser fan Type Axial Number of poles p 4 Speed rpm 1380 Isolation class B Refrigerant gas Refrigerant gas type R-134a(CH2FCF3) Net weight kg 65 Dimensions mm 480 x 595 x 400 H Internal/external protection rating IP 54/34 Noise level dB(A) 63 Power supply V Ph Hz 220-240V/1/50-60 Hz Mounting template 595 3160 2870 480 2590 2300 2000 55 1750 45 195 225 100 40 20 175 3450 35 43 3738 370 4025 Cabinet temperature °C Cooling power W Output diagram 50 40 1440 ∅ 35 1150 30 870 20 25 20 25 30 35 40 45 22.5 550 50 Ambient temperature °C 21 EN Using I.CO.S cooling units The cooling power demanded from a cooling unit is intended to compensate for the following sources of heat: 1. Heat generated by the electrical and electronic components housed in the cabinet. 2. Heat transmitted into the cabinet’s interior through its walls. Heat generated by internal components The cabinet’s internal components (transformers, contactors, inverters, drives, PLC, lamps, video displays) dissipate heat. The total nominal thermal power dissipated inside the cabinet is the sum - corrected by a simultaneity coefficient - of the heat dissipated by each component. To simplify the calculation we can use average values, independent of the component manufacturer, some of which are given in Table A. For example, it is accepted practice to assume that a transformer dissipates a thermal power of 5% of its power delivery, so that the transformer has an efficiency of 95%. The component’s heat dissipation is the opposite of its efficiency. It is always advisable, in any case, to refer to the manufacturer’s literature, especially for high power components. The simultaneity coefficient accounts for the simultaneity of operation of the equipment. This coefficient is estimated by the assembler, with the aid of a technician familiar with the application in question. Heat entering through the walls The walls of the cabinet, since they are not insulated, can transmit heat between its exterior and interior. If the interior of the cabinet is hotter than the exterior, the heat is outgoing, otherwise it is incoming. On average, we can estimate a flow of 5W per m2 of surface area and per degree of temperature difference. If the cabinet is installed outdoors, sunlight must also be accounted for, as well as the heat exchange generated by convection due to the wind. If we consider a cabinet installed indoors, away from direct sources of heat, of dimensions 2000 x 600 x 5000mm, its total surface area is 28.4m2. If the cabinet is kept at 35°C and the external ambient temperature is 45°C (typical summertime conditions ) the thermal power delivered into the interior of the cabinet will be: 28.5x5x10=1.42kW. Total thermal load The cabinet’s total thermal load, which is equivalent to the cooling unit cooling power rating, is simply the sum of the internally generated load and the load incoming (or outgoing load, in which case it is subtracted) via its walls. 22 Selecting the cooling unit There are various technologies for cooling an electrical cabinet, and hence a wide range of solutions: • air condenser air cooling units • water condenser air cooling units • air-air heat exchangers • gas pipe heat exchangers (heat-pipe units) • fans with intake filters • air-water heat exchangers • Peltier cell chillers Each of these systems is capable of “generating cold” - or rather, of transferring heat from one source to another in a variety of manners, with different operational parameters, unit footprints and costs, and hence with numerous practical benefits and disadvantages. For units in common use, we can say that: The air condenser cooling unit cannot be used at temperatures above 55°C. It is also not suited to very dusty installations. Air-air heat exchangers can be used only if it is admissible that the cabinet’s internal temperature be greater than the ambient temperature, usually by at least 10°K, and power exchange is limited. They have the benefits of low power consumption, reduced weight, simplicity and a total seal between the interior and exterior of the cabinet. The fan/filter solution can only be used if it is admissible that the cabinet’s interior temperature be greater than the ambient temperature. This type of solution is limited by IP protection rating and EMC shielding considerations. The water-air-heat exchanger is a good alternative to the classical cooling unit, but only if chilled water is already available. The solution’s costs are thus not immediately evident, and it assumes factors which may also affect its reliability. I.CO.S air-cooled cooling units I.CO.S cooling units use a gas compression cycle. The refrigerant gas is selected to offer the best COP, i.e., the best ratio between consumption and cooling power output. In designing its cooling units, I.CO.S has aimed to: Maximise output for a given consumption. Close collaboration with the compressor manufacturer has enabled us to optimise them for the operating conditions of cabinet cooling units. Reduce unit footprint. Using compact heat exchangers with detailed optimisation of internal air/fluid exchanger air flows in the latest generation heat exchangers and compact compressors has resulted in compact, reliable units. Reliability. Close collaboration with the compressor manufacturer has enabled us to optimise them for the operating conditions of cabinet cooling units, resulting in a highly reliable product. Cost effectiveness. Everything you need is standard supply. This means low running costs, transparent pricing and speedy, reliable deliveries. The cooling power of a gas compression cycle cooling unit depends, in essence, on the cabinet temperature and the ambient temperature – the temperature of the air used to cool the condenser. The humidity of the air inside the cabinet decreases EN Cabinet temperature °C Power output W over time if the cabinet is sealed (cabinet protection rating: IP 54). A cooling unit working in very humid conditions has reduced capacity to cool electrical components, so that the cabinet’s seal is an essential factor. The powers of the cooling units are, as required by established regulations, specified at 35°C / 35°C and 35°C / 50°C. The powers of the cooling units in different conditions can be derived from the diagrams given in this catalogue, of which we include an example. Ambient temperature °C The horizontal axis gives the ambient temperature (external to the cabinet). As the temperature increases, the cooling power drops off due to the increased pressure/temperature at the compressor’s delivery. The vertical axis gives the cabinet temperature, where the effect is opposite. Increased temperature leads to increased cooling power, and vice-versa. This can be seen from the fact that the compressor works at constant volume displacement, and the cooling power depends on the displaced mass. As the cabinet temperature drops, the vapour taken up by the compressor has lower density and thus lower mass per unit volume. The graph shown above enables us to easily check the operating limits of the unit, and thus avoid over-rating it. Overrating is damaging to the cooling unit because, since the cooling power cannot be modulated, the cooling unit experiences more start cycles, which can eventually lead it to fail. This is due to how the compressor is lubricated. It lubricates with oil carried into the circuit by the refrigerant itself. At every start, the oil takes a while to enter into circulation as a suspension; it follows that excessive starts can compromise the compressor’s operation. • Provide for/simulate incorrect use of the cabinet by the final user - for instance, by simulating the formation of condensation inside the cabinet. Air flows outside the cabinet The exterior of the cabinet must be free of obstacles to the flow of air, otherwise a poor flow of air or recirculation of hot air may lead to the cutouts tripping and stopping the compressor. Even only partial recirculation is damaging, since it results in lower efficiency and high absorption. The external fan is always stopped when the compressor stops to prevent soiling the condenser array and consuming energy to no effect. Condensation I.CO.S cabinet cooling units are equipped with a thermostat factory-set to 35°C. In comparison to environments inhabited by human beings, this may seem high, but it is set to this value to prevent water vapour migrating into the cabinet interior (increased relative humidity in certain areas, buildup of condensation). For the same reason, we recommend switching off the cooling unit when the cabinet door is opened. I.CO.S cooling units are equipped to receive a signal which switches them off automatically when the cabinet door is opened. Use Ambient air temperature. I.CO.S cooling units are designed not to have minimum operating temperatures. The constant operation ambient temperature is 50°C. Cabinet air temperature. The cooling units have no lower limits to the cabinet temperature, except for those mentioned previously. Electrical hookup. IMPORTANT: before hooking up the cooling unit, check that the mains frequency and voltage match those given on unit’s nameplate. Installation and dimensions Make sure that the cabinet can support the weight of the cooling unit, and that it leaves sufficient clearance around the cabinet for routine maintenance. Do not forget to lead away the condensation produced by the cooling unit, which drains from the provided discharge port. The cabinet must be drilled for cooling unit installation with the provided template. I.CO.S cooling units are easy to install since they are provided as standard with a complete electrical connector on their inner side. Air flows inside the cabinet The cabinet designer must ensure that: • There is no stratification of hot air. • The cooling unit is optimal in terms of the position of its intake and delivery ports. The correct choice may well be a top-mounted unit. • There are no obstacles to the flow of cool air into the cabinet. This may result in short-circuiting the delivery and intake flows. 23 Condizionatori serie ICS I condizionatori della serie ICS sono realizzati per essere installati sulla porta o sulla parete del quadro elettrico, sono pronti all’uso. La griglia frontale è predisposta per ospitare il filtro aria (opzionale) rimuovibile e lavabile, la dima di foratura 1:1, le viti di fissaggio ed il tubo di gomma con porta-gomma raccordo e fascetta sono comprese nella confezione del prodotto. La connessione elettrica avviene per mezzo di una spina rapida che è fornita in dotazione (da cablare). Il condizionatore è fornito con centralina elettronica di comando e controllo, completo di vaschetta di dissipazione condensa e scarico di emergenza con tubo di gomma da raccordare in fase di montaggio. Condizionatori serie ICR I condizionatori della serie ICR sono realizzati per essere installati sul tetto del quadro elettrico, sono pronti all’uso. La griglia frontale è predisposta per ospitare filtro aria (opzionale) rimuovibile e lavabile, la dima di foratura 1:1, le viti di fissaggio ed il tubo di gomma con porta-gomma raccordo e fascetta sono comprese nella confezione del prodotto. La connessione elettrica avviene per mezzo di una spina rapida che è fornita in dotazione (da cablare). Il condizionatore è fornito con centralina elettronica di comando e controllo, completo di vaschetta di dissipazione condensa e scarico di emergenza con tubo di gomma da raccordare in fase di montaggio. Funzioni del controllo elettronico Il termostato elettronico installato sui modelli ICS ed ICR possiede le seguenti caratteristiche standard: • Visualizzatore della temperatura interno quadro • Variazione del set di temperatura desiderata interno quadro • Parametri profondi protetti da password • Ritardo accensione compressore • Allarme massima temperatura • Allarme antigelo • Allarme condensatore sporco • Allarme livello vaschetta acqua per i modelli ICR da tetto • Allarme sonoro disinseribile con un tasto • Verifica funzionamento del ventilatore lato evaporatore • Contatto porta che ferma il condizionatore (programmabile: se non necessario si può escludere) • Diagnostica allarmi con visualizzatore a led e messaggi d’errore 24 IT CONDIZIONATORI pag 26 CONDIZIONATORI pag 38 INFORMAZIONI UTILI PER L’UTILIZZO DEI CONDIZIONATORI I.CO.S 25 IT Condizionatore per montaggio a parete ICS 035-380 W ICS 035 50 / 60 Hz Capacità Frigorifera (L35; L35) W 380 / 420 Capacità Frigorifera (L35; L50) W 189 / 226 Potenza assorbita nominale (L35; L50) W 350 / 391 Corrente nominale massima A 1,5 / 1,7 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Assiale Numbero Poli p 2 Rotazioni per minuto rpm 2600 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 16 Dimensioni mm 170 x 286 x 525 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 61 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz 55 440 277 380 470 97 400 520 Dima di foratura 286 260 13 13 143 50 570 Temp. interno quadro °C Potenza frigo W Diagramma di resa ø154 210 50 270 35 170 30 16 80 35 25 120 20 25 30 35 40 45 50 20 ∅ Temperatura ambiente °C 77 26 38 50 40 220 525 420 45 IT Condizionatore per montaggio a parete ICS 050-500 W ICS 050 50 / 60 Hz Capacità Frigorifera (L35; L35) W 500 / 575 Capacità Frigorifera (L35; L50) W 272 / 312 Potenza assorbita nominale (L35; L50) W 350 / 391 Corrente nominale massima A 1,6 / 1,7 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Assiale Numbero Poli p 2 Rotazioni per minuto rpm 2600 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 17 Dimensioni mm 170 x 286 x 525 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 61 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz 55 660 97 500 730 277 580 820 Dima di foratura 286 260 13 13 143 50 900 Temp. interno quadro °C ø154 210 50 420 40 350 35 260 30 16 80 35 25 180 20 25 30 35 40 45 50 38 50 45 525 420 Potenza frigo W Diagramma di resa 20 ∅ Temperatura ambiente °C 77 27 IT Condizionatore per montaggio a parete ICS 080-800 W ICS 080 50 / 60 Hz Capacità Frigorifera (L35; L35) W 800 / 920 Capacità Frigorifera (L35; L50) W 560 / 645 Potenza assorbita nominale (L35; L50) W 546 / 621 Corrente nominale massima A 2,5 / 2,7 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 27 Dimensioni mm 210 x 350 x 630 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 60 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 350 1050 1000 920 865 52.5 245 52.5 175 115 1120 65 1190 800 365 1250 Temp. interno quadro °C Potenza frigo W Diagramma di resa Ø160 735 55 670 68 40 503 45 540 630 50 600 35 480 35 25 20 25 30 35 40 45 40 270 30 410 ∅ 50 20 Temperatura ambiente °C 67 28 80 50 IT Condizionatore per montaggio a parete ICS 100-1100 W ICS 100 50 / 60 Hz Capacità Frigorifera (L35; L35) W 1100 / 1210 Capacità Frigorifera (L35; L50) W 1000 / 1100 Potenza assorbita nominale (L35; L50) W 568 / 644 Corrente nominale massima A 2,6 / 2,8 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 30 Dimensioni mm 210 x 350 x 630 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 60 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 350 1200 1150 245 1100 Ø160 55 1090 52.5 175 115 1300 52.5 65 1500 365 1700 Temp. interno quadro °C 40 68 45 1050 503 50 630 Potenza frigo W Diagramma di resa 35 900 30 35 20 20 25 30 35 40 45 40 270 25 500 ∅ 50 Temperatura ambiente °C 67 80 50 29 IT Condizionatore per montaggio a parete ICS 130-1250 W ICS 130 50 / 60 Hz Capacità Frigorifera (L35; L35) W 1250 / 1430 Capacità Frigorifera (L35; L50) W 1070 / 1230 Potenza assorbita nominale (L35; L50) W 699 / 828 Corrente nominale massima A 3,2 / 3,6 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 40 Dimensioni mm 235 x 370 x 855 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 68 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 370 1700 1570 1470 1360 15 185 340 Ø160 1250 1140 15 136.5 1790 86.5 1900 550 Temp. interno quadro °C Potenza frigo W Diagramma di resa 45 920 689 50 855 55 1100 55 260 40 85 35 820 30 25 30 35 40 Temperatura ambiente °C 45 50 20 35 25 20 16 80 155 700 ∅ 30 IT Condizionatore per montaggio a parete ICS 150-1580 W ICS 150 50 / 60 Hz Capacità Frigorifera (L35; L35) W 1580 / 1740 Capacità Frigorifera (L35; L50) W 1150 / 1265 Potenza assorbita nominale (L35; L50) W 765 / 920 Corrente nominale massima A 3,5 / 4,0 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2400 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 43 Dimensioni mm 235 x 370 x 855 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 73 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 370 1950 1800 1650 15 185 340 15 136.5 2100 86.5 2250 Ø160 1500 550 Temp. interno quadro °C 1200 55 50 1050 45 689 1350 855 55 260 85 40 900 35 25 20 25 30 35 40 Temperatura ambiente °C 45 50 20 35 30 750 16 80 155 Potenza frigo W Diagramma di resa ∅ 31 IT Condizionatore per montaggio a parete ICS 200-2000 W ICS 200 50 / 60 Hz Capacità Frigorifera (L35; L35) W 2000 / 2300 Capacità Frigorifera (L35; L50) W 1380 / 1590 Potenza assorbita nominale (L35; L50) W 1035 / 1219 Corrente nominale massima A 4,5 / 5,3 Temperatura d’impiego °C 20 - 50 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2450 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2500 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 62 Dimensioni mm 280 x 435 x 1160 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 63 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Diagramma di resa Dima di foratura Temp. interno quadro °C 2900 2600 395 20 217.5 Ø180 780 2300 25 145 3200 370 Potenza frigo W 435 20 2000 ∅ 1700 45 1100 35 1160 50 1400 400 55 80 40 300 125 30 25 20 25 30 35 40 45 50 20 350 800 35 90 Temperatura ambiente °C 32 80 30 IT Condizionatore per montaggio a parete ICS 250-2600 W ICS 250 50 / 60 Hz Capacità Frigorifera (L35; L35) W 2600 / 2860 Capacità Frigorifera (L35; L50) W 1730 / 1900 Potenza assorbita nominale (L35; L50) W 1478 / 1932 Corrente nominale massima A 6,7 / 8,4 Temperatura d’impiego °C 20 - 50 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2600 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2500 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 63 Dimensioni mm 280 x 435 x 1160 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 63 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Diagramma di resa Dima di foratura Temp. interno quadro °C 20 Ø180 780 3000 395 217.5 145 3500 25 370 4000 2500 ∅ 50 2000 45 400 55 1160 40 80 35 1500 300 125 30 25 20 1000 25 30 35 40 45 50 35 80 30 Temperatura ambiente °C 90 20 350 Potenza frigo W 435 20 33 IT Condizionatore per montaggio a parete ICS 350-3500 W ICS 350 50 / 60 Hz Capacità Frigorifera (L35; L35) W 3500 / 3850 Capacità Frigorifera (L35; L50) W 2230 / 2470 Potenza assorbita nominale (L35; L50) W 1613 / 2093 Corrente nominale massima A 7,3 / 9,1 Temperatura d’impiego °C 20 - 50 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2500 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2500 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 62 Dimensioni mm 280 x 435 x 1230 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 73 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Diagramma di resa Dima di foratura Temp. interno quadro °C 4050 198 4600 20 217.5 65 5150 395 20 400 Potenza frigo W 435 5700 Ø210 876 3500 55 ∅ 45 2400 40 1230 50 400 2950 35 318 120 25 25 30 35 40 Temperatura ambiente °C 45 50 80 90 35 20 350 20 1300 34 75 30 1860 30 IT Condizionatore per montaggio sul tetto ICR 150-1450 W ICR 150 50 / 60 Hz Capacità Frigorifera (L35; L35) W 1450 / 1670 Capacità Frigorifera (L35; L50) W 740 / 850 Potenza assorbita nominale (L35; L50) W 808 / 989 Corrente nominale massima A 3,7 / 4,3 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2500 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Assiale Numbero Poli p 4 Rotazioni per minuto rpm 1420 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 62 Dimensioni mm 480 x 595 x 400 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 63 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 595 Temp. interno quadro °C 1800 1650 1500 195 225 100 40 20 175 1950 35 43 2100 370 2250 480 Potenza frigo W Diagramma di resa 1350 1200 55 50 1050 45 ∅ 40 900 35 30 750 20 25 30 35 40 45 22.5 550 25 50 20 Temperatura ambiente °C 35 IT Condizionatore per montaggio sul tetto ICR 170-1700 W ICR 170 50 / 60 Hz Capacità Frigorifera (L35; L35) W 1700 / 1870 Capacità Frigorifera (L35; L50) W 1080 / 1190 Potenza assorbita nominale (L35; L50) W 816 / 1012 Corrente nominale massima A 3,7 / 4,4 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2600 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Assiale Numbero Poli p 4 Rotazioni per minuto rpm 1420 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 64 Dimensioni mm 480 x 595 x 400 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 63 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 595 480 1980 1700 1450 195 225 100 40 20 175 2300 35 43 2590 370 2870 Temp. interno quadro °C Potenza frigo W Diagramma di resa 55 50 45 1150 35 30 870 20 25 30 35 40 Temperatura ambiente °C 36 ∅ 40 45 25 50 20 22.5 550 IT Condizionatore per montaggio sul tetto ICR 230-2300 W ICR 230 50 / 60 Hz Capacità Frigorifera (L35; L35) W 2300 / 2530 Capacità Frigorifera (L35; L50) W 1330 / 1460 Potenza assorbita nominale (L35; L50) W 1026 / 1265 Corrente nominale massima A 4,7 / 5,5 Temperatura d’impiego °C 20 - 55 Ventilatore (lato evaporante) Tipo Centrifugo Numbero Poli p 2 Rotazioni per minuto rpm 2600 Classe d’Isolamento B Ventilatore (lato condensante) Tipo Assiale Numbero Poli p 4 Rotazioni per minuto rpm 1380 Classe d’Isolamento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Netto kg 65 Dimensioni mm 480 x 595 x 400 H Grado di protezione Interno/esterno IP 54/34 Rumorosità dB(A) 63 Alimentazione elettrica V p HZ 220-240V/1/50-60 Hz Dima di foratura 595 3160 2870 480 2590 2300 2000 55 1750 45 195 225 100 40 20 175 3450 35 43 3738 370 4025 Temp. interno quadro °C Potenza frigo W Diagramma di resa 50 40 1440 ∅ 35 1150 30 870 20 25 20 25 30 35 40 45 22.5 550 50 Temperatura ambiente °C 37 IT Informazioni utili per l’utilizzo dei condizionatori I.CO.S La potenza frigorifera richiesta ad un condizionatore serve a compensare i seguenti apporti termici: 1. Calore generato da componenti elettrici ed elettronici presenti all’interno del quadro elettrico. 2. Calore che viene trasmesso all’interno del quadro elettrico dalle pareti dello stesso. Calore prodotto dai componenti interni I componenti interni al quadro (trasformatori, teleruttori, inverter, azionamenti, PLC, lampade, video) dissipano del calore. La potenza termica nominale, totale dissipata all’interno del quadro è la somma, corretta con il coefficiente di contemporaneità, del calore dissipato da ciascun componente. Per semplificare il calcolo è possibile usare dei valori medi, indipendentemente dal produttore, alcuni dei quali sono riportati in tabella “A”. E’ prassi ritenere, per esempio, che un trasformatore dissipi mediamente una potenza termica pari al 5% della potenza erogata, quindi attribuire al trasformatore in oggetto un rendimento del 95%. Il calore dissipato è come noto, il reciproco del rendimento. E’ sempre comunque consigliabile, specialmente per componenti di elevata potenza, consultare il costruttore del componente. Il coefficiente di contemporaneità tiene conto della simultaneità del funzionamento delle apparecchiature. La stima di questo coefficiente deve essere fatta dall’assemblatore ma non senza il supporto di un tecnico che conosca l’applicazione. Calore entrante attraverso le pareti Le pareti del quadro elettrico, non essendo isolate, possono essere un importante veicolo per la trasmissione del calore tra l’interno e l’esterno. Se la temperatura interna dell’armadio elettrico è superiore a quella esterna il calore sarà uscente, in caso contrario sarà entrante. Mediamente si possono calcolare 5W per ogni m2 di superficie e per ogni grado di differenza. Se il quadro elettrico è installato all’esterno devono essere assolutamente presi in considerazione anche l’irraggiamento solare e l’influenza che può avere il vento sul coefficiente di scambio termico per convezione. Se consideriamo un quadro installato internamente, lontano da fonti di calore che possano irraggiare direttamente sul quadro, con dimensioni di 2000 x 600 x 5000mm, la superficie totale del quadro sarà 28,4m2. Se il quadro viene mantenuto a 35°C e la temperatura esterna ambiente è 45°C “caso estivo” verrà trasferita all’interno una potenza termica di: 28.5x5x10=1.42kW. Carico termico totale Il carico termico totale da smaltire, pari alla potenza frigorifera del condizionatore è semplicemente la somma del carico interno e del carico entrante (o uscente ed in questo caso va sottratto) attraverso le pareti. 38 Scelta del dispositivo di raffreddamento Esistono parecchi metodi e quindi un’ampia scelta tra le apparecchiature che si possono usare per raffreddare un quadro elettrico: • condizionatori d’aria condensati ad aria • condizionatori d’aria condensati ad acqua • scambiatori di calore aria-aria • scambiatori a tubi di gas (Heat-pipe) • ventilatori con filtro di ingresso • scambiatori aria-acqua • unità di raffreddamento a celle di Peltier Ognuno di questi sistemi è in grado di “produrre freddo” - o meglio di trasferire il calore da una fonte ad un’altra - sfruttando principi diversi, con limiti d’ impiego, ingombri e costi differenti e quindi con diversi vantaggi e svantaggi in termini pratici. Per i dispositivi di uso comune possiamo dire che: Il condizionatore condensato ad aria può essere utilizzato con temperature ambiente non superiori a 55°C. Limiti all’impiego possono essere degli ambienti particolarmente polverosi. Lo scambiatore aria-aria può essere utilizzato solo se è accettabile che la temperatura interna superi quella esterna, indicativamente di almeno 10K, fermo restando che le potenze scambiabili sono comunque limitate. I vantaggi possono essere visti nel basso consumo elettrico, peso ridotto, semplicità e completa tenuta tra esterno ed interno. Il ventilatore con filtro può essere utilizzato sole se è ammissibile che la temperatura interna superi quella esterna. I limiti di questo dispositivo sono legati al grado di protezione IP e alla schermatura EMC. Lo scambiatore acqua-aria offre una buona alternativa al condizionatore classico solo nel caso si abbia acqua refrigerata a disposizione. La valutazione economica è quindi non immediata e presuppone anche scelte che possono influenzare la affidabilità del sistema. I condizionatori raffreddati ad aria I.CO.S Il condizionatore I.CO.S è un condizionatore a ciclo di compressione di gas. Il gas frigorifero scelto è quello che offre il migliore COP, cioè il migliore rapporto tra energia frigorifera resa ed energia assorbita. Durante la progettazione dei condizionatori I.CO.S ha tenuto conto di: Massimizzare la resa a parità di consumi. La stretta cooperazione con il costruttore dei compressori ha permesso di ottimizzare gli stessi per le condizioni di lavoro dei condizionatori da quadro. Riduzioni degli ingombri. L’uso di scambiatori di calore con geometrie compatte, l’attenzione ai flussi interni a l’ottimizzazione dello scambio aria-fluido, tramite scambiatori di calore con tecnologia all’avanguardia, i compressori compatti, hanno permesso la realizzazione di macchine compatte ed affidabili. Affidabilità. Il lavoro comune con il costruttore dei compressori, ottimizzando i compressori per le condizioni di lavoro dei condizionatori da quadro elettrico, permette di dare un prodotto altamente affidabile. Economicità. Tutto quello che serve viene fornito di serie. Questo permette risparmi nella gestione, trasparenza dei prez- IT Temperatura interna al q.e. °C Potenza resa W zi, velocità e affidabilità delle consegna. La potenza frigorifera di un condizionatore a ciclo di compressione di gas dipende, semplificando, dalla temperatura all’interno del quadro elettrico e da quella esterna al quadro, aria che viene usata per raffreddare il condensatore dello stesso. L’ umidità dell’aria all’interno del quadro diminuisce nel tempo se il quadro elettrico è chiuso e sigillato (grado di protezione del quadro elettrico: IP 54). Un condizionatore che lavora in presenza di forte umidità riduce la capacità di raffreddare componenti elettrici, per questo motivo particolare attenzione deve essere posta nella sigillatura del quadro. Le potenze dei condizionatori sono, come richiesto dalle normative, specificate a 35°C / 35°C e 35°C / 50°C. Per conoscere le potenze in condizioni diverse è possibile impiegare i diagrammi presenti nel presente catalogo, di cui riportiamo un esempio. Temperatura ambiente °C L’asse orizzontale riporta la temperatura ambiente, quella esterna al quadro. All’aumentare della temperatura la potenza frigorifera cala, per effetto dell’aumento della pressione ovvero temperatura sulla mandata del compressore. L’asse verticale riporta invece la temperatura interna al quadro, dove l’effetto è opposto. Un aumento della temperatura porta ad un aumento della resa frigorifera, mentre una diminuzione l’effetto opposto. Questo è spiegabile con il fatto che il compressore lavora a volume spostato costante e la potenza frigorifera dipende dalla massa spostata. Abbassando la temperatura all’interno del quadro il vapore aspirato dal compressore ha una densità minore e quindi a parità di volume un minor peso. Il grafico sopra riportato permette, con estrema semplicità, di verificare le condizioni limite di funzionamento e permette inoltre di evitare il sovradimensionamento del condizionatore. Un sovradimensionamento è dannoso per il condizionatore in quanto, essendo la potenza frigorifera non modulabile, si ha un aumento del numero di accensioni del condizionatore, cosa che può portare ad un guasto dell’apparato. Il motivo di ciò è legato a come il compressore del condizionatore viene lubrificato. Questo avviene tramite l’olio trascinato con il fluido frigorifero dentro il circuito. Ad ogni accensione l’olio ha un ritardo nell’entrare in circolo in sospensione e questo, in seguito a molte accensioni, può compromettere la lubrificazione del compressore. La circolazione dell’aria all’interno del quadro Il progettista del quadro elettrico deve fare in modo che: • Non ci siano fenomeni di stratificazione di aria calda. • Il condizionatore scelto, per quanto riguarda la posizione delle bocche di aspirazione e di mandata, sia quello ottimale. La scelta può ricadere anche su condizionatori da tetto. • Non ci siano impedimenti all’immissione dell’aria fredda nel quadro elettrico. Questo può comportare un cortocircuito fra il flusso d’aria in ingresso ed in uscita dal quadro. • Prevedere e/o simulare un uso improprio del quadro da parte degli utilizzatori finali, simulando per esempio, la formazione di condensa all’interno del quadro. La circolazione dell’aria all’esterno del quadro Sul lato esterno non devono esistere ostacoli alla circolazione dell’aria, altrimenti la scarsa portata d’aria o il ricircolo dell’aria calda provoca l’intervento delle protezioni e il conseguente arresto del compressore stesso. Anche solo un parziale ricircolo è dannoso, in quanto si ha comunque una resa minore ed un assorbimento maggiore. Il ventilatore esterno viene sempre fermato assieme al compressore per diminuire lo sporcamento della batteria condensante ed evitare inutili consumi di energia. Formazione di condensa I condizionatori da quadro I.CO.S hanno un termostato regolato in fabbrica a 35°C. In comparazione con ambienti abitati dall’uomo potrebbe sembrare alta, ma viene mantenuta a questo valore per evitare che ci possano essere delle migrazioni di vapore d’acqua (aumento della umidità relativa in alcune zone con formazione di condensa) dall’esterno all’interno del quadro. Per lo stesso motivo è consigliabile spegnere il condizionatore quando viene aperta la porta del quadro elettrico. I condizionatori I.CO.S sono predisposti per ricevere un segnale che li fermi in caso di porte aperte. Impiego Temperatura dell’aria esterna. I condizionatori I.CO.S sono predisposti per non avere temperature minime di impiego. La temperatura ambiente esterna di lavoro costante è 50°C. Temperatura dell’aria interna. In condizionatori interni non hanno limiti inferiori alla temperatura interna, se non quanto già detto in precedenza. Connessione elettrica. E’ estremamente importante che prima di collegare il condizionatore si verifichi che la tensione e frequenza di rete siano quelle riportate sulla targa dei dati tecnici. Installazione e dimensioni E’ importante verificare che il quadro elettrico sia in grado di sostenere il peso del condizionatore e che una volta installato ci sia sufficiente spazio intorno al condizionatore per la minima manutenzione necessaria. Non bisogna dimenticare dove portare la condensa prodotta dal condizionatore e che fuoriesce dallo scarico apposito. Il quadro elettrico deve essere forato secondo la dima di foratura prevista. Il montaggio dei condizionatori da quadro I.CO.S è facilitato grazie alla fornitura di serie di un completo connettore elettrico presente sul lato interno. 39 Kühlgeräte der Serie ICS Die Kühlgeräte der Serie ICS sind für den Anbau an die Tür oder die Wand des Schaltschranks konzipiert und sofort betriebsbereit. Das vordere Gitter ist zum Aufnehmen eines herausnehmbaren und waschbaren Luftfilters (optional) eingerichtet. Die Lochschablone im Maßstab 1:1, die Befestigungsschrauben und der Gummischlauch mit Schlauchnippel und Schelle befinden sich in der Verpackung des Produkts. Für den elektrischen Anschluss wird eine Steckvorrichtung mitgeliefert (noch zu verdrahten). Das Kühlgerät verfügt über eine elektronische Steuer- und Kontrolleinheit, eine Schale zum Verdampfen des Kondenswassers und einen Gummischlauch für den Notablass, der bei der Montage anzuschließen ist. Kühlgeräte der Serie ICR Die Kühlgeräte der Serie ICR sind für die Installation auf das Schaltschrankdach konzipiert und sofort betriebsbereit. Das vordere Gitter ist zum Aufnehmen eines herausnehmbaren und waschbaren Luftfilters (optional) eingerichtet. Die Lochschablone im Maßstab 1:1, die Befestigungsschrauben und der Gummischlauch mit Schlauchnippel und Schelle befinden sich in der Verpackung des Produkts. Für den elektrischen Anschluss wird eine Steckvorrichtung mitgeliefert (noch zu verdrahten). Das Kühlgerät verfügt über eine elektronische Steuer- und Kontrolleinheit, eine Schale zum Verdampfen des Kondenswassers und einen Gummischlauch für den Notablass, der bei der Montage anzuschließen ist. Funktionen der elektronischen Steuerung Der elektronische Thermostat der Modelle ICS und ICR hat serienmäßig die folgenden Eigenschaften: • Anzeige der Innentemperatur des Schaltschranks • Innentemperatur des Schaltschranks einstellbar • Passwortschutz der wichtigen Parameter • Einschaltverzögerung des Kompressors • Übertemperaturalarm • Frostschutzalarm • Alarm bei Verschmutzung des Verflüssigers • Füllstandüberwachung des Wasserbehälters bei den Modellen ICR für den Dachaufbau • Alarmsignal mit Taste stummschaltbar • Funktionsprüfung des Ventilators auf der Verdampferseite • Türkontakt zum Abschalten des Kühlgeräts (programmierbar: er kann deaktiviert werden, falls nicht erforderlich) • Alarmdiagnose mit LED-Anzeige und Fehlermeldungen 40 D KÜHLGERÄTE pag 42 KÜHLGERÄTE pag 54 NÜTZLICHE INFORMATIONEN ZUM BETRIEB DER KÜHLGERÄTE I.CO.S 41 D Kühlgerät für den Wandanbau ICS 035-380 W ICS 035 50 / 60 Hz Kälteleistung (L35; L35) W 380 / 420 Kälteleistung (L35; L50) W 189 / 226 Nennleistungsaufnahme (L35; L50) W 350 / 391 Max. Nennstrom A 1,5 / 1,7 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Axialventilator Polzahl p 2 Drehzahl U/min 2600 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 16 Abmessungen mm 170 x 286 x 525 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 61 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz 55 440 277 380 470 97 400 520 Lochschablone 286 260 13 13 143 50 570 T innen Schaltschrank °C Kälteleistung W Leistungsdiagramm ø154 210 50 270 35 170 30 16 80 35 25 120 20 25 30 35 40 45 50 20 ∅ T Umgebung °C 77 42 38 50 40 220 525 420 45 D Kühlgerät für den Wandanbau ICS 050-500 W ICS 050 50 / 60 Hz Kälteleistung (L35; L35) W 500 / 575 Kälteleistung (L35; L50) W 272 / 312 Nennleistungsaufnahme (L35; L50) W 350 / 391 Max. Nennstrom A 1,6 / 1,7 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Axialventilator Polzahl p 2 Drehzahl U/min 2600 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 17 Abmessungen mm 170 x 286 x 525 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 61 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz 55 660 97 500 730 277 580 820 Lochschablone 286 260 13 13 143 50 900 T innen Schaltschrank °C ø154 210 50 420 40 350 35 260 30 16 80 35 25 180 20 25 30 35 40 45 50 38 50 45 525 420 Kälteleistung W Leistungsdiagramm 20 ∅ T Umgebung °C 77 43 D Kühlgerät für den Wandanbau ICS 080-800 W ICS 080 50 / 60 Hz Kälteleistung (L35; L35) W 800 / 920 Kälteleistung (L35; L50) W 560 / 645 Nennleistungsaufnahme (L35; L50) W 546 / 621 Max. Nennstrom A 2,5 / 2,7 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 27 Abmessungen mm 210 x 350 x 630 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 60 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Lochschablone 350 1050 1000 920 865 52.5 245 52.5 175 115 1120 65 1190 800 365 1250 T innen Schaltschrank °C Kälteleistung W Leistungsdiagramm Ø160 735 55 670 68 40 503 45 540 630 50 600 35 480 35 25 20 25 30 35 40 45 40 270 30 410 ∅ 50 20 T Umgebung °C 67 44 80 50 D Kühlgerät für den Wandanbau ICS 100-1100 W ICS 100 50 / 60 Hz Kälteleistung (L35; L35) W 1100 / 1210 Kälteleistung (L35; L50) W 1000 / 1100 Nennleistungsaufnahme (L35; L50) W 568 / 644 Max. Nennstrom A 2,6 / 2,8 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 30 Abmessungen mm 210 x 350 x 630 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 60 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Lochschablone 350 1200 1150 245 Ø160 1100 55 1090 52.5 175 115 1300 52.5 65 1500 365 1700 T innen Schaltschrank °C 40 68 45 1050 503 50 630 Kälteleistung W Leistungsdiagramm 35 900 30 500 35 20 20 25 30 35 40 45 40 270 25 ∅ 50 T Umgebung °C 67 80 50 45 D Kühlgerät für den Wandanbau ICS 130-1250 W ICS 130 50 / 60 Hz Kälteleistung (L35; L35) W 1250 / 1430 Kälteleistung (L35; L50) W 1070 / 1230 Nennleistungsaufnahme (L35; L50) W 699 / 828 Max. Nennstrom A 3,2 / 3,6 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 40 Abmessungen mm 235 x 370 x 855 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 68 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Leistungsdiagramm Lochschablone 1570 1470 1360 185 340 Ø160 1250 1140 15 136.5 1700 15 86.5 1790 550 T innen Schaltschrank °C Kälteleistung W 370 1900 45 920 689 50 855 55 1100 55 260 40 85 35 820 30 25 30 35 T Umgebung °C 40 45 50 20 35 25 20 16 80 155 700 ∅ 46 D Kühlgerät für den Wandanbau ICS 150-1580 W ICS 150 50 / 60 Hz Kälteleistung (L35; L35) W 1580 / 1740 Kälteleistung (L35; L50) W 1150 / 1265 Nennleistungsaufnahme (L35; L50) W 765 / 920 Max. Nennstrom A 3,5 / 4,0 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2400 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 43 Abmessungen mm 235 x 370 x 855 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 73 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Leistungsdiagramm Lochschablone 1800 1650 185 340 15 136.5 1950 15 86.5 2100 Ø160 1500 550 T innen Schaltschrank °C 1200 55 50 1050 45 689 1350 855 55 260 85 40 900 35 25 20 25 30 35 T Umgebung °C 40 45 50 20 35 30 750 16 80 155 Kälteleistung W 370 2250 ∅ 47 D Kühlgerät für den Wandanbau ICS 200-2000 W ICS 200 50 / 60 Hz Kälteleistung (L35; L35) W 2000 / 2300 Kälteleistung (L35; L50) W 1380 / 1590 Nennleistungsaufnahme (L35; L50) W 1035 / 1219 Max. Nennstrom A 4,5 / 5,3 Betriebstemperatur °C 20 - 50 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2450 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2500 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 62 Abmessungen mm 280 x 435 x 1160 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 63 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Leistungsdiagramm Lochschablone T innen Schaltschrank °C 2900 2600 395 20 217.5 Ø180 780 2300 25 145 3200 370 Kälteleistung W 435 20 2000 ∅ 1700 45 1100 35 1160 50 1400 400 55 80 40 300 125 30 25 20 25 30 35 40 45 50 20 350 800 35 90 T Umgebung °C 48 80 30 D Kühlgerät für den Wandanbau ICS 250-2600 W ICS 250 50 / 60 Hz Kälteleistung (L35; L35) W 2600 / 2860 Kälteleistung (L35; L50) W 1730 / 1900 Nennleistungsaufnahme (L35; L50) W 1478 / 1932 Max. Nennstrom A 6,7 / 8,4 Betriebstemperatur °C 20 - 50 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2600 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2500 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 63 Abmessungen mm 280 x 435 x 1160 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 63 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Leistungsdiagramm Lochschablone T innen Schaltschrank °C 20 Ø180 780 3000 395 217.5 145 3500 25 370 4000 2500 ∅ 400 55 50 2000 45 1160 40 80 35 1500 300 125 30 25 20 1000 25 30 35 40 45 50 35 80 30 T Umgebung °C 90 20 350 Kälteleistung W 435 20 49 D Kühlgerät für den Wandanbau ICS 350-3500 W ICS 350 50 / 60 Hz Kälteleistung (L35; L35) W 3500 / 3850 Kälteleistung (L35; L50) W 2230 / 2470 Nennleistungsaufnahme (L35; L50) W 1613 / 2093 Max. Nennstrom A 7,3 / 9,1 Betriebstemperatur °C 20 - 50 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2500 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2500 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 62 Abmessungen mm 280 x 435 x 1230 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 73 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Leistungsdiagramm Lochschablone T innen Schaltschrank °C 4050 198 4600 20 217.5 65 5150 395 20 400 Kälteleistung W 435 5700 Ø210 876 3500 55 2950 ∅ 40 400 45 2400 1230 50 35 318 120 25 25 30 35 T Umgebung °C 40 45 50 80 90 35 20 350 20 1300 50 75 30 1860 30 D Kühlgerät für den Dachaufbau ICR 150-1450 W ICR 150 50 / 60 Hz Kälteleistung (L35; L35) W 1450 / 1670 Kälteleistung (L35; L50) W 740 / 850 Nennleistungsaufnahme (L35; L50) W 808 / 989 Max. Nennstrom A 3,7 / 4,3 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2500 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Axialventilator Polzahl p 4 Drehzahl U/min 1420 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 62 Abmessungen mm 480 x 595 x 400 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 63 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Lochschablone 595 T innen Schaltschrank °C 1800 1650 1500 195 225 100 40 20 175 1950 35 43 2100 370 2250 480 Kälteleistung W Leistungsdiagramm 1350 1200 55 50 1050 45 ∅ 40 900 35 30 750 20 25 30 35 40 45 22.5 550 25 50 20 T Umgebung °C 51 D Kühlgerät für den Dachaufbau ICR 170-1700 W ICR 170 50 / 60 Hz Kälteleistung (L35; L35) W 1700 / 1870 Kälteleistung (L35; L50) W 1080 / 1190 Nennleistungsaufnahme (L35; L50) W 816 / 1012 Max. Nennstrom A 3,7 / 4,4 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2600 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Axialventilator Polzahl p 4 Drehzahl U/min 1420 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 64 Abmessungen mm 480 x 595 x 400 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 63 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Lochschablone 595 480 1980 1700 1450 195 225 100 40 20 175 2300 35 43 2590 370 2870 T innen Schaltschrank °C Kälteleistung W Leistungsdiagramm 55 50 45 1150 35 30 870 20 25 30 35 T Umgebung °C 52 ∅ 40 40 45 25 50 20 22.5 550 D Kühlgerät für den Dachaufbau ICR 230-2300 W ICR 230 50 / 60 Hz Kälteleistung (L35; L35) W 2300 / 2530 Kälteleistung (L35; L50) W 1330 / 1460 Nennleistungsaufnahme (L35; L50) W 1026 / 1265 Max. Nennstrom A 4,7 / 5,5 Betriebstemperatur °C 20 - 55 Ventilator (Verdampferseite) Typ Radialventilator Polzahl p 2 Drehzahl U/min 2600 Isolierstoffklasse B Ventilator (Verflüssigerseite) Typ Axialventilator Polzahl p 4 Drehzahl U/min 1380 Isolierstoffklasse B Kältemittel Kältemitteltyp R-134a(CH2FCF3) Nettogewicht kg 65 Abmessungen mm 480 x 595 x 400 H Schutzart innen/außen IP 54/34 Geräuschpegel dB(A) 63 Stromversorgung V Ph Hz 220-240V/1/50-60 Hz Lochschablone 595 3160 2870 480 2590 2300 2000 55 1750 45 195 225 100 40 20 175 3450 35 43 3738 370 4025 T innen Schaltschrank °C Kälteleistung W Leistungsdiagramm 50 40 1440 ∅ 35 1150 30 870 20 25 20 25 30 35 40 45 22.5 550 50 T Umgebung °C 53 D Nützliche Informationen zum Betrieb der Kühlgeräte I.CO.S Die von einem Kühlgerät verlangte Kälteleistung dient zur Kompensation der folgenden Wärmelasten: 1. Von den elektrischen und elektronischen Komponenten im Schaltschrank erzeugte Wärme. 2. In den Schaltschrank über dessen Wände übertragene Wärme. Von den inneren Komponenten erzeugte Wärme Die Komponenten im Schaltschrank (Transformatoren, Fernschalter, Frequenzumrichter, Antriebe, SPS, Lampen, Videogeräte usw.) geben Wärme ab. Die im Schaltschrank abgegebene Gesamtwärmeleistung ist die mit dem Gleichzeitigkeitsfaktor korrigierte Summe der von jeder Komponente abgegebenen Wärme. Um die Berechnung zu vereinfachen, kann man von der Marke unabhängige Mittelwerte verwenden, von denen einige in der Tabelle „A“ angegeben sind. In der Regel geht man beispielsweise davon aus, dass ein Transformator im Durchschnitt eine Wärmeleistung von 5% der abgegebenen Leistung abgibt, dass er also einen Wirkungsgrad von 95% hat. Die Verlustwärme ist bekanntlich invers zum Wirkungsgrad. Es empfiehlt sich jedoch in jedem Fall und insbesondere bei Komponenten hoher Leistung den Hersteller der Komponente zu konsultieren. Der Gleichzeitigkeitsfaktor berücksichtigt die Gleichzeitigkeit des Betriebs der Geräte. Dieser Faktor muss vom Monteur festgelegt werden, allerdings mit der Unterstützung eines Technikers, der die Anwendung kennt. Über die Wände zugeführte Wärme Wenn die Wände des Schaltschranks nicht isoliert sind, können sie ein wichtiges Medium für den Wärmeaustausch zwischen innen und außen sein. Wenn die Innentemperatur des Schaltschranks höher ist als die Außentemperatur, tritt Wärme aus; andernfalls tritt Wärme ein. Im Durchschnitt kann man 5W pro m2 Oberfläche und pro Grad Temperaturdifferenz veranschlagen. Befindet sich der Schaltschrank im Freien, sind unbedingt auch die Sonneneinstrahlung und der Einfluss des Winds auf den konvektiven Wärmeübergangskoeffizienten zu berücksichtigen. Betrachtet man einen Schaltschrank, der im Innenbereich und entfernt von Wärmequellen, die ihn direkt bestrahlen könnten, aufgestellt ist und die Abmessungen 2000 x 600 x 5000mm hat, beträgt die Gesamtoberfläche des Schaltschranks 28,4m2. Wird der Schaltschrank auf einer Temperatur von 35°C gehalten und beträgt die Außentemperatur 45°C (im Sommer) wird eine Wärmeleistung von 28,5x5x10 = 1,42 kW nach innen übertragen. Gesamtwärmelast Die abzuführende Gesamtwärmelast, die der Kälteleistung des Kühlgeräts entspricht, ist einfach die Summe der inneren Last und der über die Wände eintretenden Last (bzw. austretenden Last, die dann abgezogen werden muss). Wahl des Kühlgeräts Es gibt zahlreiche Methoden zum Kühlen eines Schaltschranks und folglich eine große Auswahl an Geräten: 54 • Kühlgeräte mit luftgekühltem Verflüssiger • Kühlgeräte mit wassergekühltem Verflüssiger • Luft/Luft-Wärmetauscher • Wärmerohre (Heatpipes) • Ventilatoren mit Eingangsfilter • Luft/Wasser-Wärmetauscher • Peltier-Elemente Jedes dieser Systeme ist in der Lage, „Kälte zu erzeugen“ - oder besser Wärme von einem Ort an einen anderen zu übertragen, wobei sie sich in Hinblick auf die genutzten Prinzipien, die Einsatzbeschränkungen, den Platzbedarf und die Kosten unterscheiden und folglich in praktischer Hinsicht unterschiedliche Vor-und Nachteile haben. Zu den allgemein gebräuchlichen Geräten lässt sich Folgendes sagen: Das Kühlgerät mit luftgekühltem Verflüssiger kann bei Umgebungstemperaturen von höchstens 55°C eingesetzt werden. Eine Einsatzbeschränkung kann eine besonders staubige Umgebung sein. Ein Luft/Luft-Wärmetauscher kann nur verwendet werden, wenn es zulässig ist, dass die Innentemperatur die Außentemperatur um ca. 10°K überschreitet, unbeschadet der Tatsache, dass die austauschbaren Leistungen in jedem Fall begrenzt sind. Vorteile können der geringe Stromverbrauch, das geringe Gewicht, die Einfachheit und die vollständige Abschottung zwischen innen und außen sein. Ein Ventilator mit Filter kann nur eingesetzt werden, wenn es zulässig ist, dass die Innentemperatur die Außentemperatur überschreitet. Die Einsatzbeschränkungen dieses Geräts stehen in Verbindung mit der Schutzart und der EMV-Abschirmung. Der Wasser/Luft-Wärmetauscher ist nur dann eine gute Alternative zum klassischen Kühlgerät, wenn gekühltes Wasser verfügbar ist. Die wirtschaftliche Bewertung ist daher nicht unmittelbar möglich und muss auch Entscheidungen berücksichtigen, die sich auf die Zuverlässigkeit des Systems auswirken können. Die luftgekühlten Kühlgeräte I.CO.S Das Kühlgerät I.CO.S ist eine Kompressionskältemaschine. Es wurde das Kältemittel gewählt, das den besten COP bietet, d.h. das beste Verhältnis zwischen der abgegebenen Kühlenergie und der Energieaufnahme. Bei der Planung der Kühlgeräte hat I.CO.S Folgendes berücksichtigt: Maximierung der Leistung bei gleichem Verbrauch. Die enge Zusammenarbeit mit dem Hersteller der Kompressoren gestattete deren Optimierung für die Betriebsbedingungen im Schaltschrank. Verringerter Platzbedarf. Durch die Verwendung von modernsten Wärmetauschern mit kompakter Geometrie und die Optimierung der internen Ströme und damit des Wärmetauschs zwischen Luft und Fluid konnten kompakte und zuverlässige Maschinen realisiert werden. Zuverlässigkeit. Durch die Optimierung der Kompressoren für die Arbeitsbedingungen der Kühlgeräte im Schaltschrank in Zusammenarbeit mit dem Hersteller der Kompressoren erweist sich das Produkt als hochgradig zuverlässig. Wirtschaftlichkeit. Alles was benötigt wird, ist im Lieferumfang eingeschlossen. Dies gestattet Einsparungen bei der Verwaltung, Preistransparenz sowie schnelle und zuverlässige Lieferung. Die Kälteleistung einer Kompressionskältemaschine hängt, einfach D Innentemperatur des Schaltschranks °C Leistung W gesagt, von der Temperatur der Luft innerhalb und außerhalb des Schaltschranks ab, wobei die Luft auch zum Kühlen des Verflüssigers des Kühlgeräts verwendet wird. Die Luftfeuchtigkeit im Schaltschrank nimmt mit der Zeit ab, wenn der Schaltschrank dicht verschlossen ist (Schutzart des Schaltschranks: IP 54). Wenn das Kühlgerät bei einer hohen Luftfeuchtigkeit arbeitet, verringert sich sein Vermögen, die elektrischen Komponenten zu kühlen. Daher ist der Abdichtung des Schaltschranks besondere Aufmerksamkeit zu schenken. Die Leistungen der Kühlgeräte werden vorschriftsmäßig für 35°C / 35°C und 35°C / 50°C angegeben. Die Leistungen bei anderen Bedingungen kann man den Diagrammen in diesem Katalog entnehmen, von denen wir hier ein Beispiel abbilden. Umgebungstemperatur °C Auf der horizontalen Achse ist die Umgebungstemperatur, d.h. die Temperatur außerhalb des Schaltschranks, angegeben. Mit steigender Temperatur nimmt die Kälteleistung wegen des Anstiegs des Drucks bzw. der Temperatur auf der Druckseite des Kompressors ab. Auf der vertikalen Achse ist hingegen die Innentemperatur des Schaltschranks angegeben, wobei sich dieser Effekt umkehrt. Ein Temperaturanstieg führt zu einer Erhöhung der Kälteleistung und eine Abnahme hat die entgegengesetzte Wirkung. Dies erklärt sich durch die Tatsache, dass der Kompressor ein konstantes Volumen fördert und die Kälteleistung von der geförderten Masse abhängt. Senkt sich die Temperatur im Schaltschrank, hat der vom Kompressor angesaugte Dampf eine geringere Dichte und folglich bei gleichem Volumen ein geringeres Gewicht. Mit Hilfe der obigen Grafik kann man sehr einfach die Grenzbetriebsbedingungen prüfen und überdies eine Überdimensionierung des Kühlgeräts vermeiden. Eine Überdimensionierung ist schädlich für das Kühlgerät. Da nämlich die Kälteleistung nicht modulierbar ist, erhöht sich die Zahl der Einschaltungen des Kühlgeräts, was zu einem Defekt des Geräts führen kann. Dies hängt damit zusammen, wie der Kompressor des Kühlgeräts geschmiert wird. Dies geschieht mit Öl, das vom Kältemittel im Kreislauf mitgenommen wird. Bei der Einschaltung gelangt das Öl nur mit einer Verzögerung suspendiert in Umlauf und dies kann nach vielen Einschaltungen die Schmierung des Kompressors beeinträchtigen. Die Luftzirkulation innerhalb des Schaltschranks Der Planer des Schaltschranks muss Folgendes gewährleisten: • Es dürfen sich keine Schichten warmer Luft bilden. • Das gewählte Kühlgerät muss in Hinblick auf die Position der Saug- und Druckstutzen optimal sein. Man kann sich auch für Kühlgeräte für den Dachaufbau entscheiden. • Die Zufuhr der Kaltluft in den Schaltschrank darf nicht behindert sein. Andernfalls kann es zu einem Kurzschluss zwischen dem Zuluft- und dem Abluftstrom des Schaltschranks kommen. • Man muss den unsachgemäßen Gebrauch des Schaltschranks durch die Endbenutzer vorhersehen und/oder simulieren, indem man zum Beispiel die Bildung von Kondenswasser im Schaltschrank simuliert. Die Luftzirkulation außerhalb des Schaltschranks Die Luftzirkulation außerhalb des Schaltschranks darf nicht behindert werden, da andernfalls der geringe Luftvolumenstrom oder der Umlauf der Warmluft die Auslösung der Schutzeinrichtungen und folglich die Abschaltung des Kompressors verursacht. Auch nur eine teilweise Behinderung der Zirkulation ist nachteilig, da sie zu einer geringeren Leistung und einer höheren Stromaufnahme führt. Der externe Ventilator wird stets zusammen mit dem Kompressor ausgeschaltet, um die Verunreinigung der Verflüssigerbatterie zu verringern und einen unnötigen Energieverbrauch zu vermeiden. Kondenswasserbildung Der Thermostat der Schaltschrank-Kühlgeräte I.CO.S ist werkseitig auf 35°C eingestellt. Für Wohnräume ist das gewiss zu hoch. Doch wird dieser Wert aufrechterhalten, um die Migration von Wasserdampf (Zunahme der relativen Feuchte in einigen Zonen mit anschließender Kondenswasserbildung) von außen in das Schaltschrankinnere zu verhindern. Aus dem selben Grund empfiehlt es sich, das Kühlgerät auszuschalten, wenn der Schaltschrank geöffnet wird. Die Kühlgeräte I.CO.S empfangen ein Signal, das sie abschaltet, wenn die Türen geöffnet werden. Betrieb Temperatur der Außenluft. Für die Kühlgeräte I.CO.S sind keine Mindestbetriebstemperaturen vorgesehen. Die konstante externe Temperatur der Arbeitsumgebung beträgt 50°C. Temperatur der Innenluft. Bei den internen Kühlgeräten gibt es neben den schon oben gemachten Angaben keine unteren Begrenzungen der Innentemperatur. Elektrischer Anschluss. Vor dem Anschließen des Kühlgeräts ist unbedingt sicherzustellen, dass die Netzspannung und die Netzfrequenz den Angaben auf dem Schild der technischen Daten entsprechen. Installation und Abmessungen Es ist sicherzustellen, dass der Schaltschrank das Gewicht des Kühlgeräts tragen kann und dass nach der Installation ein ausreichender Freiraum für die mindest erforderliche Wartung um das Kühlgerät vorhanden ist. Außerdem ist für den Abfluss des aus dem hierfür vorgesehenen Auslass austretenden Kondenswassers zu sorgen, welches das Kühlgerät erzeugt. Die Löcher im Schaltschrank müssen mit Hilfe der hierfür vorgesehenen Lochschablone ausgeführt werden. Die Montage der Schaltschrank-Kühlgeräte I.CO.S wird durch die serienmäßig gelieferte elektrischen Steckvorrichtung auf der Innenseite vereinfacht. 55 Climatiseurs de la série ICS Les climatiseurs de la série ICS sont conçus pour une installation sur la porte ou une paroi du tableau électrique, et prêts à l’usage. La grille frontale est équipée de filtres à air amovibles et lavables (en option), le gabarit de perçage 1:1, les vis de fixation et le tuyau en caoutchouc avec about porte-caoutchouc et gaine sont compris dans la conception du produit. Le raccordement électrique est effectué au moyen d’une prise rapide fournie (à câbler). Le climatiseur est fourni avec une centrale électronique de commande et de contrôle, complété par un réservoir de dissipation condensée et de charge d’urgence avec un tuyau en caoutchouc à raccorder pendant la phase de montage. Climatiseurs de la série ICR Les climatiseurs de la série ICR sont conçus pour une installation sur le toit du tableau électrique et sont prêts à l’usage. La grille frontale est pourvue de filtres à air amovibles et lavables (en option), le gabarit de perçage 1:1, les vis de fixation et le tuyau en caoutchouc avec about porte-caoutchouc et gaine sont compris dans la conception du produit. Le raccordement électrique est effectué au moyen d’une prise rapide fournie (à câbler). Le climatiseur est fourni avec une centrale électronique de commande et de contrôle, complété par un réservoir de dissipation condensée et de charge d’urgence avec un tuyau en caoutchouc à raccorder pendant la phase de montage. Fonctions du contrôle électronique Le thermostat électronique installé sur les modèles ICS et ICR possède les caractéristiques standard suivantes : • Afficheur de la température interne du tableau • Variation de la température souhaitée à l’intérieur du tableau • Paramètres avancés protégés par mot de passe • Allumage retardé du compresseur • Alarme de température maximale • Alarme antigel • Alarme condensateur sale • Alarme de niveau du réservoir d’eau pour les modèles ICR de toiture • Alarme sonore amovible avec un bouton • Vérification du fonctionnement du ventilateur côté évaporateur • Contact de la porte qui ferme le climatiseur (programmable : exclus le cas échéant) • Diagnostic des alarmes avec affichage à LED et messages d’erreur 56 FR CLIMATISEURS pag 58 CLIMATISEURS pag 70 RENSEIGNEMENTS UTILES POUR L’UTILISATION DES CLIMATISEURS I.CO.S 57 FR Climatiseur pour montage sur paroi ICS 035-380 W ICS 035 50 / 60 Hz Capacité frigorifique (L35; L35) W 380 / 420 Capacité frigorifique (L35; L50) W 189 / 226 Puissance absorbée nominale (L35; L50) W 350 / 391 Courant nominal max. A 1,5 / 1,7 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Axial Nombre de pôles p 2 Tours par minute tr/min 2600 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 16 Dimensions mm 170 x 286 x 525 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 61 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 470 440 13 143 277 400 380 55 ø154 210 50 270 35 170 30 16 80 35 25 120 20 25 30 35 40 45 50 38 50 40 525 420 45 220 20 ∅ T Amb. °C 77 58 13 97 520 286 260 50 570 T interne Tableau °C Puissance frigorifique W Diagramme de rendement FR Climatiseur pour montage sur paroi ICS 050-500 W ICS 050 50 / 60 Hz Capacité frigorifique (L35; L35) W 500 / 575 Capacité frigorifique (L35; L50) W 272 / 312 Puissance absorbée nominale (L35; L50) W 350 / 391 Courant nominal max. A 1,6 / 1,7 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Axial Nombre de pôles p 2 Tours par minute tr/min 2600 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 17 Dimensions mm 170 x 286 x 525 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 61 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 730 660 13 13 143 97 820 286 260 50 900 T interne Tableau °C 500 277 580 55 ø154 210 50 420 40 350 35 260 30 16 80 35 25 180 20 25 30 35 40 45 50 38 50 45 525 420 Puissance frigorifique W Diagramme de rendement 20 ∅ T Amb. °C 77 59 FR Climatiseur pour montage sur paroi ICS 080-800 W ICS 080 50 / 60 Hz Capacité frigorifique (L35; L35) W 800 / 920 Capacité frigorifique (L35; L50) W 560 / 645 Puissance absorbée nominale (L35; L50) W 546 / 621 Courant nominal max. A 2,5 / 2,7 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 27 Dimensions mm 210 x 350 x 630 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 60 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz 350 1120 1050 1000 920 52.5 245 52.5 175 65 1190 115 1250 Gabarit de perçage T interne Tableau °C 865 800 365 Puissance frigorifique W Diagramme de rendement Ø160 735 55 670 68 40 503 45 540 630 50 600 35 480 35 25 20 25 30 35 40 45 40 270 30 410 ∅ 50 20 T Amb. °C 67 60 80 50 FR Climatiseur pour montage sur paroi ICS 100-1100 W ICS 100 50 / 60 Hz Capacité frigorifique (L35; L35) W 1100 / 1210 Capacité frigorifique (L35; L50) W 1000 / 1100 Puissance absorbée nominale (L35; L50) W 568 / 644 Courant nominal max. A 2,6 / 2,8 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 30 Dimensions mm 210 x 350 x 630 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 60 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 350 1300 1200 52.5 245 52.5 175 65 1500 115 1700 T interne Tableau °C Ø160 1100 55 1090 365 1150 40 68 45 1050 503 50 630 Puissance frigorifique W Diagramme de rendement 35 900 30 500 35 20 20 25 30 35 40 45 40 270 25 ∅ 50 T Amb. °C 67 80 50 61 FR Climatiseur pour montage sur paroi ICS 130-1250 W ICS 130 50 / 60 Hz Capacité frigorifique (L35; L35) W 1250 / 1430 Capacité frigorifique (L35; L50) W 1070 / 1230 Puissance absorbée nominale (L35; L50) W 699 / 828 Courant nominal max. A 3,2 / 3,6 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 40 Dimensions mm 235 x 370 x 855 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 68 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 370 1700 1570 1470 15 185 340 1360 Ø160 1250 1140 15 136.5 1790 86.5 1900 550 T interne Tableau °C Puissance frigorifique W Diagramme de rendement 45 920 689 50 855 55 1100 55 260 40 85 35 820 30 25 30 35 T Amb. °C 40 45 50 20 35 25 20 16 80 155 700 ∅ 62 FR Climatiseur pour montage sur paroi ICS 150-1580 W ICS 150 50 / 60 Hz Capacité frigorifique (L35; L35) W 1580 / 1740 Capacité frigorifique (L35; L50) W 1150 / 1265 Puissance absorbée nominale (L35; L50) W 765 / 920 Courant nominal max. A 3,5 / 4,0 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2400 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 43 Dimensions mm 235 x 370 x 855 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 73 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 370 T interne Tableau °C 1950 1800 15 185 340 15 136.5 2100 86.5 2250 Ø160 1500 550 1650 1200 55 50 1050 45 689 1350 855 55 260 85 40 900 35 25 20 25 30 35 T Amb. °C 40 45 50 20 35 30 750 16 80 155 Puissance frigorifique W Diagramme de rendement ∅ 63 FR Climatiseur pour montage sur paroi ICS 200-2000 W ICS 200 50 / 60 Hz Capacité frigorifique (L35; L35) W 2000 / 2300 Capacité frigorifique (L35; L50) W 1380 / 1590 Puissance absorbée nominale (L35; L50) W 1035 / 1219 Courant nominal max. A 4,5 / 5,3 Température d’utilisation °C 20 - 50 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2450 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2500 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 62 Dimensions mm 280 x 435 x 1160 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 63 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Diagramme de rendement Gabarit de perçage T interne Tableau °C 2900 2600 25 395 20 217.5 145 3200 370 2300 Ø180 780 Puissance frigorifique W 435 20 2000 ∅ 1700 45 1100 35 1160 50 1400 400 55 80 40 300 125 30 25 20 25 30 35 40 45 50 20 350 800 35 90 T Amb. °C 64 80 30 FR Climatiseur pour montage sur paroi ICS 250-2600 W ICS 250 50 / 60 Hz Capacité frigorifique (L35; L35) W 2600 / 2860 Capacité frigorifique (L35; L50) W 1730 / 1900 Puissance absorbée nominale (L35; L50) W 1478 / 1932 Courant nominal max. A 6,7 / 8,4 Température d’utilisation °C 20 - 50 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2600 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2500 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 63 Dimensions mm 280 x 435 x 1160 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 63 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Diagramme de rendement Gabarit de perçage T interne Tableau °C 3500 370 3000 25 395 20 217.5 145 4000 780 Ø180 2500 ∅ 50 2000 45 400 55 1160 40 80 35 1500 300 125 30 25 20 1000 25 30 35 40 45 50 35 80 30 T Amb. °C 90 20 350 Puissance frigorifique W 435 20 65 FR Climatiseur pour montage sur paroi ICS 350-3500 W ICS 350 50 / 60 Hz Capacité frigorifique (L35; L35) W 3500 / 3850 Capacité frigorifique (L35; L50) W 2230 / 2470 Puissance absorbée nominale (L35; L50) W 1613 / 2093 Courant nominal max. A 7,3 / 9,1 Température d’utilisation °C 20 - 50 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2500 Classe d’isolation B Ventilateur (côté condensation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2500 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 62 Dimensions mm 280 x 435 x 1230 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 73 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Diagramme de rendement Gabarit de perçage T interne Tableau °C 4050 198 4600 20 217.5 65 5150 395 20 400 Puissance frigorifique W 435 5700 Ø210 876 3500 55 2950 ∅ 40 400 45 2400 1230 50 35 318 120 25 25 30 35 T Amb. °C 40 45 50 80 90 35 20 350 20 1300 66 75 30 1860 30 FR Climatiseur pour montage sur toit ICR 150-1450 W ICR 150 50 / 60 Hz Capacité frigorifique (L35; L35) W 1450 / 1670 Capacité frigorifique (L35; L50) W 740 / 850 Puissance absorbée nominale (L35; L50) W 808 / 989 Courant nominal max. A 3,7 / 4,3 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2500 Classe d’isolation B Ventilateur (côté condensation) Type Axial Nombre de pôles p 4 Tours par minute tr/min 1420 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 62 Dimensions mm 480 x 595 x 400 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 63 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 595 T interne Tableau °C 1950 1800 35 195 225 40 20 370 1650 1500 100 175 2100 43 2250 480 Puissance frigorifique W Diagramme de rendement 1350 1200 55 50 1050 45 ∅ 40 900 35 30 750 20 25 30 35 40 45 22.5 550 25 50 20 T Amb. °C 67 FR Climatiseur pour montage sur toit ICR 170-1700 W ICR 170 50 / 60 Hz Capacité frigorifique (L35; L35) W 1700 / 1870 Capacité frigorifique (L35; L50) W 1080 / 1190 Puissance absorbée nominale (L35; L50) W 816 / 1012 Courant nominal max. A 3,7 / 4,4 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2600 Classe d’isolation B Ventilateur (côté condensation) Type Axial Nombre de pôles p 4 Tours par minute tr/min 1420 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 64 Dimensions mm 480 x 595 x 400 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 63 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz 2870 Gabarit de perçage 595 T interne Tableau °C 195 225 100 40 20 175 2300 35 43 2590 1700 1450 370 1980 480 Puissance frigorifique W Diagramme de rendement 55 50 45 1150 35 30 870 20 25 30 35 T Amb. °C 68 ∅ 40 40 45 25 50 20 22.5 550 FR Climatiseur pour montage sur toit ICR 230-2300 W ICR 230 50 / 60 Hz Capacité frigorifique (L35; L35) W 2300 / 2530 Capacité frigorifique (L35; L50) W 1330 / 1460 Puissance absorbée nominale (L35; L50) W 1026 / 1265 Courant nominal max. A 4,7 / 5,5 Température d’utilisation °C 20 - 55 Ventilateur (côté évaporation) Type Centrifuge Nombre de pôles p 2 Tours par minute tr/min 2600 Classe d’isolation B Ventilateur (côté condensation) Type Axial Nombre de pôles p 4 Tours par minute tr/min 1380 Classe d’isolation B Gaz réfrigérant Type de gaz réfrigérant R-134a(CH2FCF3) Poids net kg 65 Dimensions mm 480 x 595 x 400 H Niveau de protection Intérieur/Extérieur IP 54/34 Niveau de bruit dB(A) 63 Alimentation électrique V Ph Hz 220-240V/1/50-60 Hz Gabarit de perçage 4025 595 T interne Tableau °C 3160 2870 195 225 100 40 20 175 3450 35 43 3738 2300 2000 55 1750 45 370 2590 480 Puissance frigorifique W Diagramme de rendement 50 40 1440 ∅ 35 1150 30 870 20 25 20 25 30 35 40 45 22.5 550 50 T Amb. °C 69 FR Renseignements utiles pour l’utilisation des climatiseurs I.CO.S La puissance frigorifique exigée d’un climatiseur sert à compenser les apports thermiques suivants : 1. Chaleur générée par les composants électriques et électroniques figurant à l’intérieur du tableau électrique. 2. Chaleur transmise à l’intérieur du tableau électrique par les parois. Chaleur produite par les composants internes Les composants internes du tableau (transformateurs, télérupteurs, onduleurs, actionneurs, PLC, lampes, écrans) dégagent de la chaleur. La puissance thermique nominale, totale dissipée à l’intérieur du tableau est la somme, correcte avec le coefficient de contemporanéité, de la chaleur dégagée par chacun des composants. Pour simplifier le calcul, il est possible d’utiliser des valeurs moyennes, indépendamment du producteur, lesquelles figurent dans le tableau «A». Par exemple, il est pratique de retenir qu’un transformateur dégage en moyenne une puissance thermique égale à 5% de la puissance distribuée, l’on peut donc attribuer au transformateur en question un rendement de 95%. La chaleur dégagée est, comme chacun sait, proportionnellement inverse au rendement. Il est de toute façon conseillé, en particulier pour les composants dont la puissance est élevée, de consulter le fabricant du composant. Le coefficient de contemporanéité tient compte de la simultanéité du fonctionnement des appareils. L’estimation de ce coefficient doit être réalisée par l’assembleur, mais pas sans le support d’un technicien connaissant l’application. Chaleur entrant à travers les parois Les parois du tableau électrique, n’étant pas isolées, peuvent être un vecteur de transmission de la chaleur important entre l’intérieur et l’extérieur. Si la température à l’intérieur de l’armoire électrique est supérieure à la température extérieure, la chaleur est sortante, dans le cas contraire, elle est entrante. L’on peut en moyenne calculer 5W par m2 de surface et par degré de différence. Si le tableau électrique est installé en extérieur, le rayonnement solaire et l’influence éventuelle du vent sur le coefficient de changement thermique par convection doivent absolument être pris en compte. Si l’on considère un tableau installé en intérieur, éloigné de sources de chaleur pouvant directement irradier le tableau, aux dimensions de 2000 x 600 x 5000mm, la surface totale du tableau sera 28,4m2. Si le tableau est maintenu à 35°C et que la température ambiante à l’extérieur est de 45°C («cas estival»), sera transmise à l’intérieur du tableau une puissance thermique de: 28,5x5x10=1,42 kW Charge thermique totale La charge thermique totale à éliminer, égale à la puissance frigorifique du climatiseur est simplement la somme de la charge interne et de la charge entrante (ou sortante et dans ce cas, elle est soustraite) à travers les parois. 70 Choix du dispositif de refroidissement Il existe de nombreux moyens, donc un grand choix d’appareils pouvant servir à refroidir un tableau électrique : • climatiseurs condensés à air • climatiseurs condensés à eau • échangeurs de chaleur air-air • échangeurs à tubes de gaz • ventilateurs avec filtre d’entrée • échangeurs air-eau • unité de refroidissement à cellules Peltier Chacun de ces systèmes est capable de «produire du froid» ou mieux, de transférer la chaleur d’une source à une autre en exploitant divers procédés, avec des limites d’utilisation, d’encombrement et des coûts différents et, par conséquent, divers avantages et inconvénients d’un point de vue pratique. Pour les dispositifs d’usage commun, l’on peut dire que : Le climatiseur condensé à air peut être utilisé sous des températures ambiantes ne dépassant pas les 55°C. Les environnements particulièrement poussiéreux peuvent en limiter l’usage. L’échangeur air-air peut uniquement être utilisé s’il est acceptable que la température intérieure dépasse la température extérieure, à titre indicatif d’au moins 10°K, restant que les puissances échangeables soient tout de même limitées. Les avantages sont une faible consommation électrique, un poids réduit, simplicité et fiabilité complète tant à l’intérieur qu’à l’extérieur. Le ventilateur à filtre peut être utilisé seul s’il est admis que la température intérieure soit supérieure à la température extérieure. Les limites de ce dispositif sont liées au niveau de protection IP et à l’isolation EMC. L’échangeur eau-air offre une bonne alternative au climatiseur classique, mais à l’unique condition d’avoir de l’eau réfrigérée à disposition. L’évaluation économique n’est donc pas immédiate et présuppose également des choix pouvant influer sur la fiabilité du système. Les climatiseurs refroidis à l’air I.CO.S Le climatiseur I.CO.S est un climatiseur à cycle de compression de gaz. Le gaz réfrigérant choisi est celui qui offre le meilleur COP, c’est-à-dire le meilleur rapport entre l’énergie frigorifique rendue et l’énergie absorbée. Au cours de la conception de projet des climatiseurs, I.CO.S a tenu compte de : Optimiser le rendement sans augmenter la consommation. La coopération efficace avec le fabricant des compresseurs a permis d’optimiser ces équipements pour les conditions de fonctionnement des climatiseurs pour tableaux électriques. Réduction de l’encombrement. L’utilisation d’échangeurs de chaleur à géométrie compacte, l’attention portée aux débits internes quant à l’optimisation de l’échange air-fluide par l’intermédiaire d’échangeurs de chaleur à l’avant-garde, les compresseurs de dimensions réduites, ont permis de réaliser des machines à la fois compactes et fiables. Fiabilité. Le travail commun avec le fabricant des compresseurs visant à optimiser ces derniers pour les conditions de fonctionnement des climatiseurs de tableau électrique a permis de créer un produit d’une grande fiabilité. Économie. Tous les composants utilisés sont fournis de série. Cela permet des économies de gestion, des prix transparents et une livraison rapide et fiable. La puissance frigorifique d’un climati- FR Température interne au t.e. °C Puissance rendue W seur à cycle de compression de gaz dépend, grosso modo, de la température à l’intérieur et à l’extérieur du tableau électrique et de l’air qui est utilisé pour refroidir le condensateur du tableau. L’humidité de l’ait à l’intérieur du tableau diminue dans le temps si le cadre électrique est fermé et étanche (niveau de protection du tableau électrique: IP 54). La capacité de refroidissement d’un climatiseur sur les composants électriques est réduite en présence d’une forte humidité, il est donc nécessaire de porter une attention particulière à l’étanchéité du tableau. Les puissances des climatiseurs, comme le requièrent les normes, sont spécifiées à 35°C / 35°C et 35°C / 50°C. Pour connaître les puissances dans des conditions variées, il est possible de recourir aux diagrammes figurant dans ce catalogue, dont nous reprenons un exemple. Température ambiante °C L’axe horizontal représente la température ambiante, celle à l’extérieur du tableau. Lorsque la température augmente, la puissance frigorifique diminue, suite à l’augmentation de la pression, c’est-à-dire de la température sur le passage du compresseur. L’axe vertical représente la température à l’intérieur du tableau, où l’effet est inverse. Une augmentation de la température entraîne une augmentation du rendement frigorifique, alors qu’une diminution entraîne l’effet inverse. Cela s’explique par le fait que le compresseur fonctionne à un volume déplacé constant et la puissance frigorifique dépend de la masse déplacée. En diminuant la température à l’intérieur du tableau, la vapeur aspirée par le compresseur a une densité inférieure, donc, à volume égal, un poids inférieur. Le graphique ci-dessus permet, de manière extrêmement simple, de vérifier les limites de fonctionnement et également d’éviter le surdimensionnement du climatiseur. Un surdimensionnement est néfaste pour le climatiseur puisque, la puissance frigorifique étant non modulable, l’on a une augmentation du nombre de déclenchements du climatiseur, ce qui peut engendrer une panne de l’appareil. La raison est liée à la manière dont le compresseur du climatiseur est lubrifié. Lubrification effectuée au moyen de l’huile entraînée par le fluide frigorigène dans le circuit. À chaque déclenchement, l’huile en suspension entre en retard dans le circuit et cela, après plusieurs déclenchements, peut empêcher la lubrification du compresseur. La circulation de l’air à l’intérieur du tableau Le concepteur du tableau électrique doit faire en sorte que : • Il n’y ait pas de phénomènes de stratification d’air chaud. • Le climatiseur choisi, en ce qui concerne la position des bouches d’aspiration et de sortie, doit être optimal. Le choix peut porter également sur les climatiseurs de toiture. • Il n’y ait pas d’obstacle à l’émission de l’air froid dans le tableau électrique. Celui-ci peut comporter un court-circuit entre le flux d’air à l’entrée et à la sortie du tableau. • Prévoir et/ou simuler une utilisation impropre du tableau de la part des utilisateurs finaux, simulant, par exemple, la formation de condensation à l’intérieur du tableau. La circulation de l’air à l’extérieur du tableau Sur le côté extérieur, aucun obstacle ne doit entraver la circulation de l’air, sinon le manque d’air porté ou la recirculation de l’air chaud entraîne l’intervention des protections et l’arrêt du compresseur. Une recirculation partielle de l’air est également néfaste, puisque l’on obtient de toute façon un rendement moindre et une plus grande absorption. Le ventilateur extérieur est toujours arrêté avec le compresseur pour réduire l’encrassage de la batterie de condensation et éviter des consommations d’énergie inutiles. Formation de condensation Les climatiseurs de tableau I.CO.S sont équipés d’un thermostat réglé en usine à 35°C. Comparé avec les environnements habités par l’homme, cela peut paraître une température élevée, mais la maintenir à cette valeur permet d’éviter des migrations de vapeur d’eau (augmentation de l’humidité relative dans certaines zones avec formation de condensation) de l’extérieur à l’intérieur du tableau. Pour cette raison, nous vous recommandons d’éteindre le climatiseur lorsque vous ouvrez la porte du tableau électrique. Les climatiseurs I.CO.S sont prédisposés à recevoir un signal d’arrêt en cas d’ouverture de la porte. Utilisation Température de l’air extérieur. Les climatiseurs I.CO.S sont prévus sans aucune température minimale d’utilisation. La température ambiante extérieure de fonctionnement constant est de 50°C. Température de l’air intérieur. Les climatiseurs intérieurs n’ont pas de limite inférieure à la température intérieure, si ce n’est celle déjà mentionnée. Raccordement électrique. Il est crucial qu’avant de raccorder le climatiseur, la tension soit vérifiée et la fréquence de rendement soit inscrite sur la plaquette de données techniques. Installation et dimensions Il est important de vérifier que le tableau électrique est en mesure de supporter le poids du climatiseur et qu’une fois installé, l’espace autour du climatiseur soit suffisant pour l’entretien minimum nécessaire. Il ne faut pas oublier où se fixe la condensation produite par le climatiseur et qui sort de l’évacuation appropriée. Le tableau électrique doit être percé selon le gabarit de perçage prévu. Le montage des climatiseurs de tableau I.CO.S est simplifié grâce à la fourniture de série d’un connecteur électrique complet figurant sur le côté extérieur. 71 Climatizadores de la serie ICS Los climatizadores de la serie ICS son realizados para ser instalados en la puerta o en la pared del cuadro eléctrico y se entregan listos para el uso. La rejilla frontal está preparada para alojar en ella el filtro del aire (opcional) removible y lavable; la plantilla de perforación 1:1, los tornillos de fijación y el tubo de goma con porta-goma, racor y abrazadera están incluidos en el embalaje del producto. La conexión eléctrica se efectúa mediante un enchufe rápido suministrado adjunto (por cablear). El climatizador se suministra con centralita electrónica de mando y control, además de cubeta de disipación condensación y evacuación de emergencia con tubo de goma a acoplar durante el montaje. Climatizadores de la serie ICR Los climatizadores de la serie ICR son realizados para ser instalados en el techo del cuadro eléctrico y se entregan listos para el uso. La rejilla frontal está preparada para alojar en ella el filtro del aire (opcional) removible y lavable; la plantilla de perforación 1:1, los tornillos de fijación y el tubo de goma con porta-goma, racor y abrazadera están incluidos en el embalaje del producto. La conexión eléctrica se efectúa mediante un enchufe rápido suministrado adjunto (por cablear). El climatizador se suministra con centralita electrónica de mando y control, además de cubeta de disipación condensación y evacuación de emergencia con tubo de goma a acoplar durante el montaje. Funciones del control electrónico El termostato electrónico instalado en los modelos ICS e ICR posee las siguientes características estándar: • Visualizador de la temperatura interior cuadro • Variación del set de temperatura requerida interior cuadro • Parámetros profundos protegidos mediante contraseña • Retardo de encendido compresor • Alarma temperatura máxima • Alarma anticongelación • Alarma condensador sucio • Alarma nivel cubeta agua para los modelos ICR de techo • Alarma sonora desactivable mediante botón • Verificación funcionamiento del ventilador lado evaporador • Contacto puerta que detiene el climatizador (programable: si no es necesario, puede ser excluido) • Diagnóstico alarmas con visualizador de led y mensajes de error 72 ES CLIMATIZADORES pag 74 CLIMATIZADORES pag 86 INFORMACIONES ÚTILES PARA EL USO DE LOS CLIMATIZADORES I.CO.S 73 ES Climatizador para montaje en pared ICS 035-380 W ICS 035 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 380 / 420 Capacidad Refrigerante (L35; L50) W 189 / 226 Potencia nominal consumida (L35; L50) W 350 / 391 Corriente nominal máxima A 1,5 / 1,7 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Axial Número polos p 2 Rotaciones por minuto rpm 2600 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 16 Dimensiones mm 170 x 286 x 525 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 61 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 470 440 13 143 277 400 380 55 ø154 210 50 270 35 170 30 16 80 35 25 120 20 25 30 35 40 45 50 38 50 40 525 420 45 220 20 ∅ T Ambiente °C 77 74 13 97 520 286 260 50 570 T interior Cuadro °C Potencia Refrigerante W Diagrama de rendimiento Tipo Gas Refrigerante ES Climatizador para montaje en pared ICS 050-500 W ICS 050 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 500 / 575 Capacidad Refrigerante (L35; L50) W 272 / 312 Potencia nominal consumida (L35; L50) W 350 / 391 Corriente nominal máxima A 1,6 / 1,7 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Axial Número polos p 2 Rotaciones por minuto rpm 2600 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 17 Dimensiones mm 170 x 286 x 525 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 61 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 730 660 13 13 143 97 820 286 260 50 900 T interior Cuadro °C 500 277 580 55 ø154 210 50 420 40 350 35 260 30 16 80 35 25 180 20 25 30 35 40 45 50 38 50 45 525 420 Potencia Refrigerante W Diagrama de rendimiento Tipo Gas Refrigerante 20 ∅ T Ambiente °C 77 75 ES Climatizador para montaje en pared ICS 080-800 W ICS 080 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 800 / 920 Capacidad Refrigerante (L35; L50) W 560 / 645 Potencia nominal consumida (L35; L50) W 546 / 621 Corriente nominal máxima A 2,5 / 2,7 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 27 Dimensiones mm 210 x 350 x 630 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 60 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz 350 1120 1050 1000 920 52.5 245 52.5 175 65 1190 115 1250 Plantilla de perforación T interior Cuadro °C 865 800 365 Potencia Refrigerante W Diagrama de rendimiento Ø160 735 55 670 68 40 503 45 540 630 50 600 35 480 35 25 20 25 30 35 40 45 40 270 30 410 ∅ 50 20 T Ambiente °C 67 76 80 50 ES Climatizador para montaje en pared ICS 100-1100 W ICS 100 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 1100 / 1210 Capacidad Refrigerante (L35; L50) W 1000 / 1100 Potencia nominal consumida (L35; L50) W 568 / 644 Corriente nominal máxima A 2,6 / 2,8 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 30 Dimensiones mm 210 x 350 x 630 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 60 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 350 1300 1200 52.5 245 52.5 175 65 1500 115 1700 T interior Cuadro °C 1100 Ø160 55 1090 365 1150 40 68 45 1050 503 50 630 Potencia Refrigerante W Diagrama de rendimiento 35 900 30 500 35 20 20 25 30 35 40 45 40 270 25 ∅ 50 T Ambiente °C 67 80 50 77 ES Climatizador para montaje en pared ICS 130-1250 W ICS 130 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 1250 / 1430 Capacidad Refrigerante (L35; L50) W 1070 / 1230 Potencia nominal consumida (L35; L50) W 699 / 828 Corriente nominal máxima A 3,2 / 3,6 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 40 Dimensiones mm 235 x 370 x 855 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 68 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 370 1700 1570 1470 15 185 340 1360 Ø160 1250 1140 15 136.5 1790 86.5 1900 550 T interior Cuadro °C Potencia Refrigerante W Diagrama de rendimiento 45 920 689 50 855 55 1100 55 260 40 85 35 820 30 25 30 35 T Ambiente °C 40 45 50 20 35 25 20 16 80 155 700 ∅ 78 ES Climatizador para montaje en pared ICS 150-1580 W ICS 150 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 1580 / 1740 Capacidad Refrigerante (L35; L50) W 1150 / 1265 Potencia nominal consumida (L35; L50) W 765 / 920 Corriente nominal máxima A 3,5 / 4,0 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2400 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 43 Dimensiones mm 235 x 370 x 855 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 73 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 370 T interior Cuadro °C 1950 1800 15 185 340 15 136.5 2100 86.5 2250 Ø160 1500 550 1650 1200 55 50 1050 45 689 1350 855 55 260 85 40 900 35 25 20 25 30 35 T Ambiente °C 40 45 50 20 35 30 750 16 80 155 Potencia Refrigerante W Diagrama de rendimiento ∅ 79 ES Climatizador para montaje en pared ICS 200-2000 W ICS 200 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 2000 / 2300 Capacidad Refrigerante (L35; L50) W 1380 / 1590 Potencia nominal consumida (L35; L50) W 1035 / 1219 Corriente nominal máxima A 4,5 / 5,3 Temperatura de empleo °C 20 - 50 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2450 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2500 Clase de aislamiento B Gas Refrigerante Diagrama de rendimiento Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 62 Dimensiones mm 280 x 435 x 1160 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 63 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación T interior Cuadro °C 2900 2600 25 395 20 217.5 145 3200 370 2300 Ø180 780 Potencia Refrigerante W 435 20 2000 ∅ 1700 45 1100 35 1160 50 1400 400 55 80 40 300 125 30 25 20 25 30 35 40 45 50 20 350 800 35 90 T Ambiente °C 80 80 30 ES Climatizador para montaje en pared ICS 250-2600 W ICS 250 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 2600 / 2860 Capacidad Refrigerante (L35; L50) W 1730 / 1900 Potencia nominal consumida (L35; L50) W 1478 / 1932 Corriente nominal máxima A 6,7 / 8,4 Temperatura de empleo °C 20 - 50 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2600 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2500 Clase de aislamiento B Gas Refrigerante Diagrama de rendimiento Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 63 Dimensiones mm 280 x 435 x 1160 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 63 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación T interior Cuadro °C 3500 370 3000 25 395 20 217.5 145 4000 780 Ø180 2500 ∅ 50 2000 45 400 55 1160 40 80 35 1500 300 125 30 25 20 1000 25 30 35 40 45 50 35 80 30 T Ambiente °C 90 20 350 Potencia Refrigerante W 435 20 81 ES Climatizador para montaje en pared ICS 350-3500 W ICS 350 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 3500 / 3850 Capacidad Refrigerante (L35; L50) W 2230 / 2470 Potencia nominal consumida (L35; L50) W 1613 / 2093 Corriente nominal máxima A 7,3 / 9,1 Temperatura de empleo °C 20 - 50 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2500 Clase de aislamiento B Ventilador (lado condensante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2500 Clase de aislamiento B Gas Refrigerante Diagrama de rendimiento Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 62 Dimensiones mm 280 x 435 x 1230 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 73 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación T interior Cuadro °C 198 4600 20 217.5 65 5150 395 20 4050 400 Potencia Refrigerante W 435 5700 Ø210 876 3500 55 2950 ∅ 2400 40 400 45 1230 50 35 318 120 25 25 30 35 T Ambiente °C 40 45 50 80 90 35 20 350 20 1300 82 75 30 1860 30 ES Climatizador para montaje en techo ICR 150-1450 W ICR 150 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 1450 / 1670 Capacidad Refrigerante (L35; L50) W 740 / 850 Potencia nominal consumida (L35; L50) W 808 / 989 Corriente nominal máxima A 3,7 / 4,3 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2500 Clase de aislamiento B Ventilador (lado condensante) Tipo Axial Número polos p 4 Rotaciones por minuto rpm 1420 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 62 Dimensiones mm 480 x 595 x 400 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 63 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 595 T interior Cuadro °C 1950 1800 35 195 225 40 20 370 1650 1500 100 175 2100 43 2250 480 Potencia Refrigerante W Diagrama de rendimiento 1350 1200 55 50 1050 45 ∅ 40 900 35 30 750 20 25 30 35 40 45 22.5 550 25 50 20 T Ambiente °C 83 ES Climatizador para montaje en techo ICR 170-1700 W ICR 170 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 1700 / 1870 Capacidad Refrigerante (L35; L50) W 1080 / 1190 Potencia nominal consumida (L35; L50) W 816 / 1012 Corriente nominal máxima A 3,7 / 4,4 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2600 Clase de aislamiento B Ventilador (lado condensante) Tipo Axial Número polos p 4 Rotaciones por minuto rpm 1420 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 64 Dimensiones mm 480 x 595 x 400 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 63 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz 2870 Plantilla de perforación 595 T interior Cuadro °C 195 225 100 40 20 175 2300 35 43 2590 1700 1450 370 1980 480 Potencia Refrigerante W Diagrama de rendimiento 55 50 45 1150 35 30 870 20 25 30 35 T Ambiente °C 84 ∅ 40 40 45 25 50 20 22.5 550 ES Climatizador para montaje en techo ICR 230-2300 W ICR 230 50 / 60 Hz Capacidad Refrigerante (L35; L35) W 2300 / 2530 Capacidad Refrigerante (L35; L50) W 1330 / 1460 Potencia nominal consumida (L35; L50) W 1026 / 1265 Corriente nominal máxima A 4,7 / 5,5 Temperatura de empleo °C 20 - 55 Ventilador (lado evaporante) Tipo Centrífugo Número polos p 2 Rotaciones por minuto rpm 2600 Clase de aislamiento B Ventilador (lado condensante) Tipo Axial Número polos p 4 Rotaciones por minuto rpm 1380 Clase de aislamiento B Gas Refrigerante Tipo Gas Refrigerante R-134a(CH2FCF3) Peso Neto kg 65 Dimensiones mm 480 x 595 x 400 H Grado de protección Interno/Externo 54/34 Ruidosidad dB(A) 63 Alimentación eléctrica V Ph Hz 220-240V/1/50-60 Hz Plantilla de perforación 4025 595 T interior Cuadro °C 3160 2870 195 225 100 40 20 175 3450 35 43 3738 2300 2000 55 1750 45 370 2590 480 Potencia Refrigerante W Diagrama de rendimiento 50 40 1440 ∅ 35 1150 30 870 20 25 20 25 30 35 40 45 22.5 550 50 T Ambiente °C 85 ES Informaciones Útiles para el Uso de los climatizadores I.CO.S La potencia refrigerante requerida a un climatizador sirve para compensar las siguientes aportaciones térmicas: 1. Calor generado por componentes eléctricos y electrónicos presentes en el interior del cuadro eléctrico. 2. Calor transmitido hacia el interior del cuadro eléctrico por las paredes del mismo. Calor producido por los componentes internos Los componentes internos del cuadro (transformadores, telerruptores, accionamientos, PLC, lámparas, vídeo) disipan calor. La potencia térmica nominal total disipada en el interior del cuadro es la suma, corregida con el coeficiente de contemporaneidad, del calor disipado por cada componente. Para simplificar el cálculo se pueden utilizar valores medios, independientemente del productor, algunos de los cuales aparecen en la tabla “A”. Es praxis estimar, por ejemplo, que un transformador disipe en promedio una potencia térmica equivalente al 5% de la potencia proporcionada, esto es, atribuir al transformador un rendimiento del 95%. Como se sabe, el calor disipado es el valor inverso del rendimiento. En todo caso es siempre conveniente, en especial para componentes de elevada potencia, consultar al fabricante del componente mismo. El coeficiente de contemporaneidad considera la simultaneidad de funcionamiento de los equipos. La estimación de este coeficiente debe ser efectuada por el ensamblador, pero con el soporte de un técnico que conozca la aplicación. Calor que entra a través de las paredes Careciendo de aislamiento, las paredes del cuadro eléctrico pueden ser un importante vehículo de transmisión del calor entre el interior y el exterior. Si la temperatura interna del armario eléctrico es superior a aquella externa, el calor será de salida y, en caso contrario, será de entrada. En general, es posible calcular 5W por cada m2 de superficie y por cada grado de diferencia. Si el cuadro eléctrico está instalado al aire libre, deberán considerarse absoluta y adicionalmente la irradiación solar y la influencia eventual del viento sobre el coeficiente de intercambio térmico por convección. Si consideramos un cuadro instalado internamente, lejos de fuentes de calor que puedan irradiar directamente sobre el mismo, con dimensiones de 2000 x 600 x 5000mm, la superficie total del cuadro será de 28,4m2. Si el cuadro es mantenido a 35°C y la temperatura del ambiente externo es de 45°C (“caso estival”) se transferirá hacia el interior una potencia térmica de: 28,5 x 5 x 10 = 1,42 kW. Carga térmica total La carga térmica total a disipar, igual a la potencia refrigerante del climatizador, es simplemente la suma de la carga interna y de la carga que entra (o que sale y en este caso debe ser sustraída) a través de las paredes. 86 Elección del dispositivo de refrigeración Existen muchos métodos y, por lo tanto, una amplia variedad de aparatos que se pueden utilizar para enfriar un cuadro eléctrico: • climatizadores de aire por aire • climatizadores de aire condensados por agua • intercambiadores de calor aire-aire • intercambiadores de tubos de gas (Heat-pipe) • ventiladores con filtro de entrada • intercambiadores aire-agua • unidades de refrigeración con celdas de Peltier Cada uno de estos sistemas es capaz de “producir frío” o, mejor aún, de transferir el calor de una fuente a otra aprovechando diferentes principios, con límites de empleo, dimensiones y costes diferentes y, por lo tanto, con diferentes ventajas y desventajas en términos prácticos. Para los dispositivos de uso común podemos decir que: El climatizador condensado por aire puede ser utilizado con temperaturas ambientes no superiores a 55°C. Límites de uso pueden ser ambientes particularmente polvorientos. El intercambiador aire-aire puede utilizarse sólo si es aceptable que la temperatura interna supere la externa, aproximadamente en al menos 10°K, considerando que las potencias intercambiables son en todo caso limitadas. Las ventajas pueden ser vistas en el bajo consumo eléctrico, peso reducido, simplicidad y completa estanqueidad entre exterior e interior. El ventilador con filtro puede utilizarse sólo en caso de ser admisible que la temperatura interna supere a aquella externa. Los límites de este dispositivo se refieren al grado de protección IP y al apantallado EMC. El intercambiador agua-aire ofrece una buena alternativa al climatizador clásico sólo en caso de poder utilizar agua refrigerada. Por lo tanto, la evaluación económica no es inmediata y presupone también opciones que pueden cambiar la fiabilidad del sistema. Los climatizador refrigerados por aire I.CO.S I.CO.S es un climatizador de ciclo de compresión de gas. El gas refrigerante elegido es aquel que ofrece el mejor COP, esto es, la mejor relación entre energía refrigerante producida y energía absorbida. Durante el diseño de los climatizadores, I.CO.S ha tenido en cuenta: Maximizar el rendimiento sin variación de los consumos. La estrecha cooperación con el fabricante de los compresores ha permitido optimizar los mismos para las condiciones de trabajo de los climatizadores de cuadro. Reducción de dimensiones. El uso de intercambiadores de calor con geometrías compactas, la atención a los flujos internos y la optimización del intercambio aire-fluido mediante intercambiadores de calor con tecnología de vanguardia, además de los compresores compactos, han permitido producir máquinas compactas y fiables. Fiabilidad. El trabajo en común con el fabricante de los compresores, optimizándolos para las condiciones de trabajo de los climatizadores de cuadro eléctrico, permite ofrecer un producto de elevada fiabilidad. Economía. Todo lo que se utiliza es suministrado de serie. Esto permite obtener ahorros en la gestión, transparencia en los precios y velocidad y fiabilidad en la entrega. ES Temperatura interior al cuadro eléctrico °C Potencia de rendimiento W La potencia refrigerante de un climatizador de ciclo de compresión de gas depende, simplificando, de la temperatura interna del cuadro eléctrico y de aquella externa al cuadro mismo, aire que se usa para enfriar el respectivo condensador. La humedad del aire interior del cuadro disminuye paulatinamente si el cuadro mismo está cerrado y sellado (grado de protección del cuadro eléctrico: IP 54). Un climatizador que trabaja en presencia de fuerte humedad reduce la capacidad de enfriar componentes eléctricos, motivo por el cual se debe prestar particular atención al sellado del cuadro mismo. Tal como requieren las normativas, las potencias de los climatizadores son especificadas a 35°C / 35°C y 35°C / 50°C. Para conocer las potencias en condiciones diferentes, es posible emplear los diagramas del presente catálogo, de los cuales a continuación mostramos un ejemplo. Temperatura ambiente. °C El eje horizontal presenta la temperatura ambiente, aquella externa al cuadro. Al aumentar la temperatura, la potencia refrigerante disminuye por efecto del aumento de la presión y de la temperatura en el envío del compresor. En cambio, el eje vertical presenta la temperatura interna del cuadro, en que el efecto es opuesto. Un aumento de la temperatura lleva a un aumento del rendimiento refrigerante, mientras que una disminución produce el efecto opuesto. Esto se explica con el hecho de que el compresor trabaja a volumen desplazado constante y la potencia refrigerante depende de la masa desplazada. Reduciendo la temperatura en el interior del cuadro, el vapor aspirado por el compresor tiene una densidad menor y por lo tanto, con igual volumen se verifica un menor peso. El gráfico precedente permite verificar con extremada sencillez las condiciones límites de funcionamiento y, además permite evitar un sobredimensionamiento del climatizador. Un sobredimensionamiento es dañino para el climatizador ya que, no siendo modulable la potencia refrigerante, se verifica un aumento del número de encendidos del climatizador mismo, lo que puede provocar avería en el aparato. El motivo de lo anterior está relacionado con el hecho de que el compresor del climatizador está lubricado. Esto se verifica mediante el aceite arrastrado con el fluido refrigerante dentro del circuito. Con cada encendido el aceite sufre un retardo de entrada en circulación en suspensión y esto, después de muchos encendidos, puede comprometer la lubricación del compresor. La circulación del aire en el interior del cuadro El diseñador del cuadro eléctrico debe obtener que: • No se produzcan fenómenos de estratificación de aire caliente. • El climatizador elegido, por lo que refiere a la posición de las bocas de aspiración y de envío, sea aquel más adecuado. También es posible elegir climatizadores de techo. • No haya impedimento para la introducción del aire frío en el cuadro eléctrico. Esto puede provocar un cortocircuito entre el flujo de aire en entrada y el de salida del cuadro. • Prever y/o simular un uso impropio del cuadro de parte de los usuarios finales simulando, por ejemplo, la formación de condensación en el interior del mismo. La circulación del aire en el exterior del cuadro En la parte externa no debe haber obstáculos para la circulación del aire ya que, de lo contrario, el escaso caudal de aire o la recirculación de aire caliente provoca la intervención de las protecciones y la consiguiente detención del compresor. Incluso sólo una recirculación parcial es dañina, ya que se verifica un rendimiento menor y una absorción mayor. El ventilador externo es detenido junto con el compresor a fin de disminuir el ensuciamiento de la batería condensadora y evitar inútiles consumos de energía. Formación de condensación Los climatizadores de cuadro I.CO.S tienen un termostato regulado en la fábrica en 35°C. En comparación con ambientes habitados por el hombre podría parecer una temperatura alta, pero es mantenida en este valor para evitar eventuales migraciones de vapor de agua (aumento de la humedad relativa en algunas zonas, con formación de condensación) desde el exterior hacia el interior del cuadro. Por el mismo motivo, es conveniente apagar el climatizador al abrir la puerta del cuadro eléctrico. Los climatizadores I.CO.S están preparados para recibir una señal que los detiene en caso de puertas abiertas. Empleo Temperatura del aire externo Los climatizadores I.CO.S han sido preparados para no tener temperaturas mínimas de empleo. La temperatura ambiente constante externa de trabajo es de 50°C. Temperatura del aire interno En climatizadores internos no hay límites inferiores a la temperatura interna, salvo lo dicho anteriormente. Conexión eléctrica Es extremadamente importante que, antes de conectar el climatizador, se verifique que la tensión y frecuencia de red sean aquellas que se indican en la placa de datos técnicos. Instalación y dimensiones Es importante verificar que el cuadro eléctrico sea capaz de sostener el peso del climatizador y que, una vez instalado, quede suficiente espacio en torno al climatizador mismo para efectuar el mantenimiento mínimo requerido. No olvidar dónde conducir la condensación producida por el climatizador, que sale a través del respectivo conducto de evacuación. El cuadro eléctrico debe ser perforado aplicando la plantilla de perforación suministrada adjunta. El montaje de los climatizadores de cuadro I.CO.S se facilita gracias al suministro de serie de un conector eléctrico completo, presente en la parte interna. 87 Sede legale: Via Aldo Moro, 11/E 41030 Bomporto (MO) Italy Phone +39 059 818143 Fax +39 059 8170482 Strada degli Schiocchi, 12 41124 Modena (MO) Italy www.icoseurope.com [email protected] cod. I.CO.S-INT/Rev.01/10 Uffici: