MULTIGAS ANALYSIS - Spacelabs Healthcare

Transcripción

MULTIGAS ANALYSIS - Spacelabs Healthcare
MULTIGAS ANALYSIS
Speed and Performance in a Small Package
SpacelabsHealthcare’sMultigasModuleincorporatesadvancedtechnology–
includingthePHASEINgasanalysisbench,theNomoline™(no-moisture)gas
samplinglineandtheServomexO2sensor–forincreasedperformance
andreliabilityinmonitoringCO2,N2O,O2andanestheticagents.
Advanced Technology for
Speed, Accuracy and Reliability
ThisMultigasModule
iscapableofidentifying
anddisplayingagent
valuesinlessthan
20secondsafterstart
up,andissuitable
foruseonallpatient
populations–from
newbornthroughadult
–duetoitslowsample
flowrate(50ml/min).
Acompactsolutionfor
yourcompletegas
analysisneeds,itcan
beintegrateddirectly
intoSpacelabspatient
monitoringsystems.
•
PHASEINgasanalysisbenchwarmsupandbegins
providingfullaccuracyofgasconcentrationdataand
agentidentificationinlessthan20seconds.Automatic
zerocalibrationatstartup,andthenonceevery8hours
ofcontinuoususe,eliminatesmultiplezeroingmessages
andthedropoffofcriticaldata.Alight-emittinggasinlet
providesastatusindicatortotheuser,detectingthe
presenceofaNomolinesamplinglineandproviding
color-codedinformationaboutbenchstatusand
thealarmsystem.
• Servomexparamagneticoxygensensorprovidesinspired
oxygen(FiO2),expiredoxygen(FeO2)andinstantaneousO2
values.Anon-depletingsensor,itdoesnotrequirereplacement.
• Nomoline“no-moisture”gassamplinglineprovideswater
andfiltrationmanagementwithouttheneedforwatertraps.
Achoiceofsingleandmultipleuseversionsavailable.
92518MultigasModule
For all Patient Populations – Neonate through Adult
TheMultigasModule’shighlyefficientPHASEINgasanalysis
benchusesasampleflowrateofjust50ml/min–allowing
side-streamgassamplingonallpatientpopulations.
Compact & Compatible
ForintegrationwithSpacelabsXprezzon™andUltraviewSL®
patientmonitoringsystems.
System
OK
NomolineGasSamplingLine
Comprehensive Gas Analysis
• AUTOagentidentification
-Isoflurane
-Desflurane
-Sevoflurane
-Enflurane
Alarm
Warning
LightEmittingGasInlet(LEGI)StatusIndicator
Performance Specifications
WarmUp
• RELIABLECO2&multigasmonitoring
• FASTO2technology
Anesthetic
AgentPresent
SampleLineFlow
<20secondsforconcentrationreporting,automatic
agentidentification,andfullaccuracyspecification
50ml/min±10ml/min
Occlusion
Automaticallydetectsandattemptstoclear
samplelineocclussions
SuspendSampling
InSuspendMode,sensorscontinuetooperatebut
pumpstopsandwaveformsandnumericzonesare
cleared,allowingsensorstoremainwarmedup
-Halothane
www.spacelabshealthcare.com
Spacelabs Healthcare Company Headquarters
5150 220th Ave. SE, Issaquah, WA 98029
PO Box 7018, Issaquah, WA 98027-7018
Telephone: +1 425-657-7200
© 2011 Spacelabs Healthcare
Specifications subject to change without notice. Ultraview SL and
Xprezzon are trademarks of Spacelabs Healthcare. Other brands
and product names are trademarks of their respective owners.
Product may not be available in all locations. Check with your
local Spacelabs representative.
In North America: +1 800-522-7025
Fax: +1 425-657-7212
M1122-de11