multisplit - Refrigeracion Lozano
Transcripción
multisplit - Refrigeracion Lozano
MANUAL DE ESPAÑOL INSTRUCCIONES Y DE INSTALACIÓN UNIDADES CONDENSADORAS MULTISPLIT Modelos BMC-BMH 18-50 BMC21S23 BMC25S24 (R22 y R407C) BMC-BMH27S33 BMC-BMH36S33 BMC-BMH50S33 (R22) 035T83261-000 Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 1 6/28/04, 10:27 AM 1 CONTENIDOS 1 - SEGURIDAD ............................................................................................ 2 2 - ESPECIFICACIONES TÉCNICAS ........................................................... 3 3 - DIMENSIONES ........................................................................................ 5 4 - INSTALACIÓN .......................................................................................... 5 5 - CONEXIONES DE TUBERÍAS DE REFRIGERANTE ............................. 6 6 - DESCONGELACIÓN ............................................................................... 7 7 - DIAGRAMA DEL CABLEADO .................................................................. 8 8 - GUÍA PARA LA SOLUCIÓN DE PROBLEMAS ...................................... 10 9 - CUIDADO Y MANTENIMIENTO ............................................................. 11 10 - APÉNDICE TÉCNICO ...........................................................................11 11 - DECLARACIÓN DE CONFORMIDAD ................................................. 12 TE CH NIC AL GU IDE 1 - SEGURIDAD Este sistema de aire acondicionado debe instalarlo sólo personal cualificado. Para el buen funcionamiento de esta unidad es necesario llevar a cabo las tareas habituales de mantenimiento, como la limpieza de bobinas y de filtros. CUIDADO Antes de abrir la unidad, asegúrese de que está desconectada de la corriente. CONEXIONES ELÉCTRICAS Todas las conexiones y cableado eléctricos deben ajustarse a las normas y los códigos de 2 J175ES la zona. El cable de corriente y el de interconexión no debe ser más delgado que el cable enfundado de policloropreno (245 IEC 57 o H05RN-F). El dispositivo de desconexión debe tener una separación de contacto de al menos 3 mm. PRECAUCIONES GENERALES Compruebe que el suministro eléctrico disponible concuerda con la tensión indicada en la placa. Use una protección apropiada para su línea eléctrica. La unidad deberá estar conectada a la toma de tierra. Y DE INSTALACIÓN UNIDADES CONDENSADORAS 2 6/28/04, 10:27 AM 2 - ESPECIFICACIONES TÉCNICAS Multi Split (BMC-BMH) - 50 Hz Modelos Unidad exterior Suministro de alimentación V/Ph/Hz Consumo de energía BMC-BMH 18 21 25 21S23 25S24 50 36 220-240/1/50 kW 2 x 0,91 0,91 + 1,21 2 x 1,21 0,91 + 1,15 2 x 1,15 3,6 5,6 A 2 x 4,2 4,2 + 5,7 2 x 5,7 4,2 + 5,3 2 x 5,3 16,9 26,5 Carga de refrigerante (BMC-BMH) gr 2 x 930 930 + 1.050 2 x 1.050 1.000 + 1.060 2 x 1.060 1.950 1.700 Refrigerante máximo gr 2 x 950 950 + 1.050 2 x 1.050 1.150 +1.210 2 x 1.210 2 x 4,30 2 x 3,75 Corriente R-22 Tipo de refrigerante 2 Cantidad Compresor Tipo de compresor Dimensiones Rotatorio Alternando Altura mm 969 969 969 969 969 900 1.142 Anchura mm 850 850 850 850 850 1.060 1.060 Fondo mm 287 287 287 287 287 345 345 kg 61 64,5 66 69 71 130 165 Peso Rotatorio Tipo Tuberías Diámetro Tuerca de mariposa Succión pulgada 3/8 3/8 y 1/2 1/2 3/8 3/8 5/8 5/8 Líquido pulgada 1/4 1/4 1/4 1/4 1/4 3/8 3/8 21 25 25S24 36 50 Multi Split (BMC-BMH) - 60 Hz Modelos Unidad exterior Suministro de alimentación V/Ph/Hz Consumo de energía BMC-BMH 18 21S23 208-230/1/60 kW 2 x 1,09 1,09 + 1,20 2 x 1,20 0,91 + 1,1 2 x 1,15 3,6 5,6 A 2 x 5,19 5,19 + 5,7 2 x 5,7 4,15 + 5,2 2 x 5,3 16,9 26,5 Carga de refrigerante (BMC-BMH) gr 2 x 930 930 + 1.050 2 x 1.050 1.000 + 1.060 1.060 + 1.060 2.300 1.700 Refrigerante máximo gr 2 x 950 950 + 1.050 2 x 1.050 1.150 + 1.210 - - Corriente Tipo de refrigerante R-22 Cantidad Compresor 2 Tipo de compresor Dimensiones Rotatorio Alternando Altura mm 696 696 696 696 696 900 1.142 Anchura mm 850 850 850 850 850 1.060 1.060 Fondo mm 287 287 287 287 287 345 345 kg 77 80 81,5 69 71 130 165 Peso Rotatorio Tipo Tuberías Diámetro 2 x 1.210 Tuerca de mariposa Succión pulgada 3/8 3/8 y 1/2 1/2 3/8 3/8 5/8 5/8 Líquido pulgada 1/4 1/4 1/4 1/4 1/4 3/8 3/8 Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 3 6/28/04, 10:27 AM 3 Modelos Refrigeración Capacidades nominales Calefacción BMC-BMH Unidad exterior 36 50 27S33 36S33 50S33 Btu/h 18000 x 2 24000 x 2 8200 x 3 11500 x3 (1100 x 2)+22500 kW 5,3 x 2 7,0 x 2 2,4 x 3 3,4 x 3 (3,2 x 2)+6,59 kcal/h 4550 x 2 6060 x 2 2066 x 3 2900 x 3 (2772 x 2)+5670 Btu/h 18400 x 2 24200 x 2 - 12100 x 3 (11500 x 2)+23500 kW 5,4 x 2 7,1 x 2 - 3,5 x 3 (3,4 x 2)+6,89 kcal/h 4670 x 2 6190 x 2 - 3050 x 3 (2898 x 2) + 5922 V/Ph/Hz Suministro de alimentación Consumo de energía Consumo de corriente 208-230/1/60 kW 4,02 6,26 2,87 3,70 5,13 A 19,51 29,82 13,30 17,00 25,22 gr 2300 x2 1700 x 2 3 x 750 1160 x 3 2 2 3 3 3 ROTATORIO ALTERNANDO ROTATORIO ROTATORIO ROTATORIO R22 Tipo de refrigerante Carga refrigerante (BMC/BMH) Cantidad Unidad exterior Kompressor Kompressortyp Dimensiones Altura mm 900 1142 1142 1142 1142 Anchura mm 1060 1060 850 850 1060 Fondo mm 345 345 285 285 345 kg 128 163 113 126 164 Peso Acero galvanizado Material Carcasa mm Grosor 0,9 Pintura de poliéster Acabado Tuberías (1400 x2)+2400 Typ Tuerca de mariposa Succión pulgada 5/8 5/8 3/8 1/2 1/2 , 5/8 Líquido pulgada 3/8 3/8 1/4 1/4 1/4 , 3/8 Modelos Unidad exterior 18G 21G BMC-BMH 25G 36G 50G Suministro de alimentación V/Ph/Hz Diámetro Multi Split R407C 220-240/1/50 kW 2 x 1,11 1,11 + 1,37 2 x 1,37 2 x 2,09 2 x 2,74 A 2 x 5,28 5,28 + 6,6 2 x 6,6 2 x 9,22 2 x 13,07 Carga de refrigerante (BMC) gr 2 x 930 930 + 1.000 2 x 1.000 2 x 2100 2 x 2000 Carga de refrigerante (BMH) gr 2 x 930 930 + 950 2 x 950 2 x 2100 2 x 1900 Consumo de energía Corriente R-407C Tipo de refrigerante 2 Cantidad Unidad Exterior Compresor Dimensiones Tipo de compresor Rotatorio Altura mm 696 696 696 900 1.142 Anchura mm 850 850 850 1.060 1.060 Fondo mm 287 287 287 345 345 kg 61 64,5 66 130 165 Peso Acero galvanizado Material Carcasa Grosor mm 0,9 Pintura de poliéster Acabado Tipo Tuberías 4 J175ES Pipe Size Tuerca de mariposa Succión pulgada 3/8 3/8 y 1/2 1/2 5/8 5/8 Líquido pulgada 1/4 1/4 1/4 3/8 3/8 Y DE INSTALACIÓN UNIDADES CONDENSADORAS 4 6/28/04, 10:27 AM 3 - DIMENSIONES Dimensiones generales Unidad exterior BMC-BMH 18-50 Unidad exterior BMC-BMH 27-50 S33 D H W Las dimensiones de las unidades se muestran la tabla de Especificaciones técnicas. 4 - INSTALACIÓN La instalación de la unidad implica: – – – – montaje de la unidad conexiones de los tubos de refrigerante conexiones de descarga de agua condensada en la unidad con bomba de calor conexiones del cableado de la unidad. Espacio libre alrededor de unidad exterior Se necesita un mínimo de espacio libre alrededor de las unidades para asegurar que la circulación de aire se realiza correctamente y para poder realizar fácilmente el manteniemiento y las reparaciones. BMC-BMH 18-50 Unidad BMC-BMH 27-50 S33 200 400 100 190 600 E D A B C A B C D E BMC-BMH 18 - 50 200 400 100 190 600 BMC-BMH 27-50 S33 Ubicación de la unidad exterior OK Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 5 6/28/04, 10:27 AM 5 5 - CONEXIONES DE TUBERÍAS DE REFRIGERANTE Asegúrese de que las longitudes y los cambios de dirección y elevación se mantienen estrictamente al mínimo. Para evitar pérdidas de calor, las dos líneas deben aislarse de forma independiente. Sujete las cañerías con abrazaderas y cerciórese de que cualquier vibración de las cañerías no se transmite a la estructura del edificio. Utilice sólo tubo de calidad para refrigeración para presiones de funcionamiento de 30 bares. No utilice tubo de cobre de tipo sanitario: DEBE utilizar tubo de calidad para refrigeración para cobre desoxidado y desgrasado. LONGITUDES DE TUBERÍAS • Longitudes máximas de tuberías Tamanõ de la unidad interior D (m) L (m) H (m) 9 12 15 10 12 15 18 12 18 15 18 12 25 22 25 20 NOTA En los casos en que las diferencia de levación entre la unidad interior y la exterior sea mayor de 5 mestros, debe instalarse un prurificador de aceite cada 5 metros. La línea de aspiración debe tener un gradiente del 2% hacia el compresor en las secciones horizontales. Cuando los tubos sean muy largos e incluyen muchos purificadores de aceite, es posible que sea necesario ajustar la carga del compresor. – Vacíe las cañerías. Esta operación, que debería durar por lo menos 15 minutos si las cañerías son largas y hay cambios en la elevación, debe ir seguida de una prueba para comprobar si hay fugas de agua. – Para ello, después de vaciar el tubo, cierre la espita del manómetro, anote el valor del manómetro y espere 15 minutos. Si la aguja se mueve, existe una fuga en el sistema. Realice los ajustes o reparaciones necesarios y repita el proceso hasta que la aguja no se mueva. – Abra las válvulas de servicio y recargue de refrigerante si fuera necesario. Model : BMC-BMH 27-50 Model : BMC21S23U15, BMC25X24U15 Aislamiento H1 - H2 UNIDAD A1 UNIDAD A2 L1 C L3 B H L2 Grosor mínimo de 6 mm H1 - H2 Unidad Interior Modelos A2 BMC B1 B2 BMC 20 m 20 m 20 m L L1 + L2 L1 + L2 L1 + L2 Longitud máxima de la diferencia de tubos – Longitud mínima permitida del tubo 8m 8m 8m L1 - L2 L1 - L2 L1 - L2 12 m 5m 5m 5m H H H H – 1m 1m 1m H1 + H2 H1 + H2 H1 + H2 3m 3m 3m 3m L L1, L2 L1, L2 L1, L2 L3 H3 C H2 L2 H1 B L1 A Y DE INSTALACIÓN UNIDADES CONDENSADORAS 6 D1 D2 4 x MHC09B A1 15 m Diferencia de altura máxima permitida entre la Unidad 1 y la Unidad 2 J175ES B2 B1 L1 Longitud máxima permitida del tubo Altura máxima permitida del tubo L UNIDAD B2 3 x MHC09B A Unidad Exterior D H 6 A H L1 L2 L L2 UNIDAD B1 6/28/04, 10:27 AM D3 • Tamaños de los cables BMC/H18 Tamaño de la unidad M2 Suministro de alimentación 3x4 M2 2 x 4 x 2,5 Interconxión BMC/H21 BMC/H25 BMC/H36 BMC21S23 BMC25S24 3x4 3x4 3 x 10 3 x 4 x 2,5 4 x 4 x 2,5 BMC/H50 BMC/H BMC/H50 27-36 S33 S33 3 x 10 3 x 16 3 x 16 2 x 4 x 2,5 2 x 4 x 2,5 3 x 4 x 2,5 3 x 4 x 2,5 • Debe añadirse carga de refrigerante por cada metro extra de tubo superior a 7,5 metros. Tamaños de la unidad g/m 9 12 12 15 18 40 25 40 Conexiones de tuberías de refrigerante (conexiones de ensanchamiento) Para evitar la alteración de las capacidades de las unidades, compruebe que las longitudes y los cambios de elevación se mantienen estrictamente al mínimo. Antes de conectar las líneas de refrigerante, siga el procedimiento siguiente (si no se instalan precargadas): – Seleccione tubos de cobre con un diámetro acorde con el tamaño de la unidad que va a instalar. – Instale las líneas de refrigeración, compruebe que no hay cuerpos extraños en los tubos. – Instale los conectores de ensanchamiento y abocine el extremo de los tubos. BMC-BMH 27-50 S33 BMC-BMH 18-50 Unidad exterior Unidad interior Línea de gas Espita de presión Línea de líquido D S S D D S S R22/R407C D S D 6 - DESCONGELACIÓN La descongelación se lleva a cabo mediante el panel de control electrónico de la unidad interior utilizando el sensor para detectar la temperatura del serpentín exterior. Hay un cable conectado entre el panel electrónico y el sensor del serpentín de la unidad exterior como se muestra en la ilustración inferior. Si la unidad no se descongela correctamente, compruebe el cable de conexión o póngase en contacto con el Servicio Técnico de York. Panel de control Unidad interior Cable de conexión 5 m (10 m y 50 m opcional) Unidad exterior Sensor del serpentín exterior Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 7 6/28/04, 10:27 AM 7 7 - DIAGRAMA DEL CABLEADO - R22 BLU WHT BMC-BMH 18-25 COMM. MAIN. AUX. CF1 PNK s R M C RED BLK BLU CC1 M BLK FAN MOTOR COMPRESSOR MOTOR A BRW BLU PNK BLU BRW 4 SOL2 R2 4 4-WAY B 3 SOL1 3 R1 COMPRESSOR MOTOR B BLU BLK 4-WAY A CC2 RED YEL WHT BLU WHT R C WHT s M 1 BLU R1 5 1 R2 N 1 2 3 4 N L N 1 UNIT A 2 3 4 TB1 UNIT B 035T00130-009 POWER SUPPLY 220 -240 Va.c. 1 Ph 50 Hz 208 -230 Va.c. 1 Ph 60 Hz BMC18R15A, BMC18G15P BMC21R15A, BMC21G15P BMC25R15A, BMC25G15P WHT PNK WHT BRW BLU BLU BLK RED BLK BRW 5 035T00716-000 BMH18R15A, BMH18G15P BMH21R15A, BMH21G15P BMH25R15A, BMH25G15P BMC-BMH 36-50 L N N N 1 2 N 1 2 BMC36R15A, BMC50R15A BMC36G15P, BMC50G15P BMC36R15AD, BMC50R15AD BMC36G15PD, BMC50G15PD BMH36-50R15ADFG BMH36-50G15PDFG 2 BRW BRW BRW BRW GRY GRY BLC BRL WHT CRG BLK RLD RC1 RC2 BLU BRW S R G S R G COMP B COMP Sv4 P4 WHT YEL S R G COMP A 035T00271 - 000 BMC25S24 Y DE INSTALACIÓN UNIDADES CONDENSADORAS 8 R4 CH2 YEL BLU PW RED WHT YEL YEL BRW WHT BUK YEL BLU CRG CRG BLU BLU Sv3 P3 BMC21S23 J175ES BRW BRW BLU BLU CRG CF BLU BRW CH1 CC2 035T00270 - 000 REV. 01 8 R3 BLU 1 CC1 BLK AC N Sv2 BLU 2 R2 AC2 PM 1 P2 LHS YEL UNIT B1 WH1 N BRW BLU S R G COMP B 2 R1 BLU PM WHL YEL S R G COMP A 1 WHT BLU Sv1 REW P1 RED REW BRW BRW 2 RC2 RLD N 1 BLU UNIT A1 RC1 BLU RLD POWER SUPPLY BLU FAN SV2 R1 N N CF BRW PLK PLK YEL BRW YEL NET RED BLU CC3 BLK BR BLU YEL REU BLU BLU YEL BLU BRW CC2 BLU 2 CC1 PH 1 YEL BLU N SV1 PH UNIT B1 UNIT B2 2 R2 BRW AC1 BLU BRW L UNIT A2 BRW BRW WH1 A4 UNIT B2 REU AC BRW BRW R3 A3 WHL BRW A2 GRY BLU A1 GRY UNIT A N BLU GUW N BRW BLU L RHU POWER SUPPLY BMC-BMH 36-50 6/28/04, 10:27 AM BMH36R16S33 BMH50R16S33 COMM. AUX. R FAN MOTOR #2 M BLU VIO N COMM. DCT DCT C A1 A1 A1 MC1 MC2 MC3 A2 A2 A2 RV D/F INTERFACE CONTROLLER PNK T2 VIO N L A MC2 L N RV D/F N L MC2 L2 T2 N L N 1 2 3 4 N 1 2 3 4 TB1 BLU 4-WAY C SDL3 4-WAY B VIO ORG WHT BRW BLU GRY RED BLK BRW BLU BRW BLU BRW N L YEL ORG T2 RED N 1 2 3 4 BLU VIO YEL GRY BRW TB2 BLU BRW UNIT C 4-WAY A BLU 4-WAY C SDL1 YEL ORG SDL3 4-WAY B BLU BLU RED VIO ORG WHT BRW BLU GRY RED BLK BRW BLU MC2 L2 T2 SDL2 4-WAY A SDL1 TB1 BRW BLU N L BLU BLU BRW VIO YEL GRY BRW N 1 2 3 4 T2 ORG MC2 TB2 M G FAN MOTOR #2 MC1 N L2 AUX. SDL2 BRW MAIN BLU BLU L L2 BRW C5 PNK L1 O/F RVA L BLU L2 ORG BLU RVB WHT O/F BLK RV O/F N BRW M G N L AUX. FAN MOTOR #1 T2 L A PNK T1 RV D/F N L COMM. BLU B RV O/F INTERFACE CONTROLLER TGRY MC3 S BLU DCT A A1 DCT BLU BLU A1 MC2 A1 GRY BRW C3 C A1 L MAIN BLU COMPRESSOR MOTOR C MC1 L2 MC1 N C COMPRESSOR MOTOR B M G COMPRESSOR MOTOR C INTERFACE CONTROLLER BRW C4 PNK GRY BLU MAIN BLU GRY T1 C BRW BRW PNK L1 RV D/F VIO BRW RV C5 BLU VIO YEL O/F RVC N MC2 VIO BLU C TGRY YEL S BLU RV O/F N L T1 INSET 4.7 K RESISTOR BRW S BRW C3 RED M GRY ORG R C2 WHT YEL L C COMPRESSOR MOTOR B M FAN MOTOR #1 WHT R/C L N MC1 L1 BLU R O/F INTERFACE CONTROLLER BRW COMPRESSOR MOTOR A M G ORG WHT BLU AUX. DCT DCT YEL MAIN COMM. BLU C BRW BLU C4 PNK GRY RV GRY T1 RED L1 RV O/F B MC2 VIO COIL SENSOR C BLU DCT T1 INSET 4.7 K RESISTOR C S DCT M C2 035T00865-000 COIL SENSOR B C1 BLK RED R/C MC1 L1 BLU WHT BLK S C RV BRW R M COMPRESSOR MOTOR A R COIL SENSOR A 035T00863-000 COIL SENSOR B COIL SENSOR C BLK BLU WHT C1 RED BLK BLK BLU C BLU S A COIL SENSOR A R M N L N 1 2 3 4 N 1 2 3 4 BLU BRW POWER SUPPLY N 220~240 Vo.c. 1 Ph 50 Hz L 208~230 Vo.c. 1 Ph 60 Hz PE UNIT A UNIT B UNIT C POWER SUPPLY N 220~240 Vo.c. 1 Ph 50 Hz L 208~230 Vo.c. 1 Ph 60 Hz PE UNIT A UNIT B BMC27-36R15S33 Para detalles de conexión de la unidad, veáse el diagrama del interior de la unidad. Encienda la unidad y compruebe la operación tanto en el modo refrigeración como en el modo calefacción. Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 9 6/28/04, 10:27 AM 9 8 - GUÍA PARA LA SOLUCIÓN DE PROBLEMAS Problema A. El compresor no funciona Causa probable y solución 1. Fusible de control fundido. Sustituya el fusible. Si el fusible se funde inmediatamente, busque algún fallo eléctrico en el sistema. 2. Relé de bloqueo defectuoso. Antes de desechar el relé, coloque el interruptor en posición de apagado y de nuevo en la configuración seleccionada. De esta forma el relé de bloqueo se libera de la electricidad. Si se corrige el estado del relé, el compresor comenzará a funcionar. Si no comienza, compruebe la continuidad mediante el relé. Sustitúyalo si es necesario. 3. Control de presión defectuoso. Sustituya el control si es defectuoso o no está bien calibrado. Los controles de tipo encapsulado no pueden volver a calibrarse. 4. Contactos abiertos en el interruptor de baja presión. La presión de succión es inferior a la de la configuración. Localice y repare la fuga de refrigerante. Vacíe y vuelva a cargar el sistema. 5. Contactos abiertos en el interruptor de alta presión. Reduzca la presión a la de la configuración. Consulte el apartado E. 6. Sobrecarga del ventilador del condensador disparado o defectuoso. Sobrecarga configurada incorrectamente. Configurar según las especificaciones técnicas. Las bobinas no están configuradas según las instrucciones. Sustituya el motor. B. El compresor hace ciclos cortos 1. Contacto intermitente en el circuito eléctrico. Repare o sustituya el control eléctrico defectuoso. 2. Sobrecarga de refrigerante o de gas no condensable en el sistema (aire). Reduzca la alta presión. Purgue todo el sistema. Vacíelo y recárguelo. Control en ciclo L.P. 3. Falta refrigerante. Localice y repare la fuga. Purgue, evacúe y recargue. 4. Fluctuación de voltaje. El voltaje no debe ser superior al 10% de la especificación de la unidad. 5. El compresor del motor está sobrecargado. Ha aumentado la corriente debido a que el condensador está hermético. Sustituya el compresor. Carga incorrecta. Ajustar la sobrecarga a la configuración especificada en el diagrama de cableado. 6. Compresor defectuoso. Deseche y sustituya el compresor sólo como última medida y después de que haya descartado todas las demás fuentes de error. C. El compresor arranca pero sólo funciona 1. Cableado incorrecto. Compruebe el cableado con el diagrama de cableado. 2. Voltaje del cable bajo. Compruebe el voltaje de la unidad mientras el compresor se intenta arrancar. El voltaje no debe ser superior al 10% del voltaje especificado. 3. La resistencia de las bobinas del compresor no se ajusta a las especificaciones. Compruebe la continuidad y la resistencia entre los terminales utilizando un óhmetro. 4. Compresor inmóvil. Sustituya el compresor. 1. Cableado incorrecto. Compruebe el cableado con el diagrama de cableado. 2. Voltaje del cable bajo. Compruebe el voltaje de la unidad mientras el compresor se intenta arrancar. El voltaje no debe ser superior al 10% del voltaje especificado. 3. La resistencia de las bobinas del compresor no se ajusta a las especificaciones. Compruebe la continuidad y la resistencia entre los terminales utilizando un óhmetro. 4. Compresor inmóvil. Sustituya el compresor. D. El compresor funciona de forma continuada E. Presión demasiado alta 1. Calor excesivo. Conmpruebe la entrada de aire y/o el aislamiento del espacio que rodea la unidad. Si la temperatura elevada es constante, quizás sea necesaria una mayor capacidad o una segunda unidad. 2. Escasez de refrigerante. Localice y repare la fuga, vacíe y recargue. 3. Condensador sucio. Limpie el condensador. 4. Compresor ineficaz. Compruebe la presión de succión y cualquier otro posible origen del problema antes de sustituir el compresor. 5. Termostato de la habitación defectuoso. Si la temperatura de la habitación es satisfactoria y la unidad continúa funcionando, reduzca o aumente la temperatura. Si el compresor no funciona, sustituya el termostato. F. Presión demasiado baja 1. Sobrecarga de refrigerante. Purgue, vacíe y recargue el sistema con la cantidad adecuada de refrigerante. 2. Aire o no condensable en el sistema. Purgue, vacíe y recargue el sistema. 3. Condensador sucio. Limpie las aletas y utilice aire comprimido. G. Presión demasiado baja 1. Escasez de refrigerante. Localice y repare la fuga, vacíe y recargue el sistema. 2. Válvulas de decraga o de succión ineficaces. Sustituya el compresor. H. Presión de succión demasiado alta 1. Carga excesiva en el evaporador. Compruebe la entrada de aire y/o el aislamiento del espacio que rodea la unidad. 2. Compresor ineficaz. Si la temperatura elevada es constante, quizás sea necesaria una mayor capacidad o una segunda unidad. Compruebe la presión de succión y cualquier otro posible origen del problema antes de sustituir el compresor. I. 1. Escasez de refrigerante. Localice la fuga, repárela, vacíe y recargue el sistema. 2. Restricción parcial o completa en el sistema de refrigeración. Compruebe que el tubo del líquido no está en una zona con la temperatura demasiado baja o que no está congelada. Compruebe el funcionamiento de las válvulas y de los elementos conectados a la electricidad. Presión de succión demasiado baja 10 Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 10 6/28/04, 10:27 AM PUENTE PARA BOMBA DE CALOR Para bomba de calor: Asegúrese de introducir un puente restrictor de 4.7k, colocado a la unidad exterior, con el cable de conexión para el cuadro electrónico de la unidad interior, según se muestra en la figura siguiente. PUENTE DE RESISTENCIA 4.7k CABLE DESDE EL CUADRO INTERIOR Si se introduce el puente, no podrá funcionar el acondicionador de aire. 9 - CUIDADO Y MANTENIMIENTO MANTENIMIENTO MENSUAL MANTENIMIENTO ANUAL 1. Los filtros de aire se deben limpiar cada 4 semanas como máximo. En algunas zonas se deben limpiar semanalmente. Los filtros deben cambiarse anualmente en la mayoría de modelos con conducto. 2. Compruebe que el circuito de refrigerante continee la carga de refrigerante correcta. 3. Compruebe que el serpentín del condensador no está obstruido ni excesivamente sucio y, si es necesario, lave el serpentín desde el interior de la estructura con cuidado para no dañar las aletas de aluminio. La garantía NO cubre este proceso. Es el dueño quien se debe ocupar de ello. 4. Compruebe que el/los disco/s para la suciedad están sujetos al eje. 5. Compruebe que el agua de la bandeja para líquido condensado está limpia. Limpie la bandeja si es necesario. 6. Compruebe que todos los paneles de la estructura están encajados y elineados correctamente. 7. Limpie la estructura según las instrucciones. 8. Compruebe el funcionamiento del termostato y fíjelo. 1. Repita el mantenimiento mensual. 2. Conecte los manómetros de servicio y registre el modo y la presión de funcionamiento. 3. Pruebe la configuración del colocando un par termoeléctrico en la ranura succionadora y reducir esa temperatura en la temperatura de succión del compresor. o o Una lectura de 4 C a 6 C es adecuada. 4. Compruebe que la estructura no tiene ningún desconchado ni abrasiones en la pintura. 5. Limpie la estructura con la misma frecuencia con que limpiaría la pintura de un coche. 6. Mida y registre el amperaje de cada motor fijándose en los detalles de la placa. 7. Registre los voltajes entre las fases a tierra o neutro. 8. Sustituya el filtro cuando sea necesario. 9. Si el evaporador de la polea se ventila, ajuste la correa. 10 - APÉNDICE TÉCNICO Capacidad de la Unidad La capacidad total para la refrigeración puede determinarse usando los factores de corrección C1, C2 y C3. Capacidad dada para refrigeración = Capacidad para la refrigeración en condiciones estándar de evaluación x C1 x C2 x C3. C1 = Factor de corrección de capacidad para la temperatura C2 = Corrección de capacidad para la longitud de los tubos C3 = Corrección de capacidad para la velocidad del ventilador de la unidad interior Y DE INSTALACIÓN UNIDADES CONDENSADORAS 11 J175ES 11 6/28/04, 10:27 AM Temperatura húmeda de aire entrante, unidad interior (CWB) Factor de corrección de capacidad para la temperatura (C1) 35 Factor de corrección de capacidad C1 30 Rango de temperatura de funcionamiento 120% 110% 25 100% 90% 20 85% R.C. 15 10 20 25 30 35 40 45 Temperatura seca de aire entrante, unidad exterior (CDB) Corrección de capacidad para la longitud de los tubos (C2) Unidades interiores 5 10 1,00 0,98 Longitud de la tubería (m) Factor de corrección C2 Corrección de capacidad para la velocidad del ventilador de la unidad interior (C3) Velocidad del ventilador Factor de corrección C3 Unidades interiores Alta Media Baja 1 0,90 0,75 Límites de temperatura de funcionamiento Máximo Mínimo (BMC-BMH27-50S33) Modo refrigeración + 46°C + 16°C Modo calefacción + 24°C (modo bomba de calor) – 8°C Mínimo (BMC-BMH18-50) + 19°C (– 5 con el kit de temperatura baja) – 8°C 11 - DECLARACIÓN DE CONFORMIDAD RETIRADA, DESMONTAJE Y DESECHO ¡Este producto contiene refrigerante a presión, partes giratorias, y conexiones eléctricas que podrían ser peligrosas y causar heridas! Cualquier manipulación deberá ser llevada a cabo sólo por personal especializado que use ropa de protección adecuada y tenga en cuenta las precauciones de seguridad. Lea el manual Riesgo de descarga eléctrica La unidad puede controlarse a distancia y podría ponerse en marcha sin previo aviso 1. Aísle todas las fuentes de corriente eléctrica de la unidad, incluida cualquier fuente de algún sistema de control que se encienda a través de la unidad. Asegúrese de que todos los puntos de aislamiento eléctrico y de gas permanecen seguros en su posición OFF (apagado). Entonces podrá desconectar y quitar los cables de alimentación y las tuberías del gas. En cuanto a los puntos de conexión, consulte las instrucciones de instalación de la unidad. 2. Quite todo el refrigerante de cada sistema de la unidad y deposítelo en un contenedor apropiado, usando una unidad de recuperación o recogida de refrigerante. Así este refrigerante podrá volverse a usar, si es posible, o devolverse al fabricante para desecharlo. El refrigerante no deberá liberarse en la atmósfera bajo ninguna circunstancia. Cuando proceda, desagüe el aceite refrigerante de cada sistema en un contenedor apropiado y deséchelo según las leyes y ordenanzas locales. 3. Normalmente la unidad empaquetada puede retirarse en una pieza después de realizar la desconexión anterior. Deberá retirarse todos los tornillos de fijación y luego alzar la unidad desde su posición usando los puntos indicados y los métodos correctos para levantarla. Se DEBE consultar las instrucciones de instalación de la unidad para conocer el peso de la unidad y los métodos correctos para alzarla. Tenga en cuenta que cualquier aceite refrigerante residual o derramado debería limpiarse y desecharse de la forma descrita anteriormente. 4. Después de retirarlas de su posición, las piezas de la unidad podrán desecharse según lo dispuesto en las leyes y ordenanzas locales. YORK® International Corporation 035T83261-000 12 Y DE INSTALACIÓN UNIDADES CONDENSADORAS J175ES 12 6/28/04, 10:27 AM