Revista Paraguay Oral Research Vol. 1 Nº 1
Transcripción
Revista Paraguay Oral Research Vol. 1 Nº 1
Paraguay Oral Research PAOR V o l 1 - n ° 1 w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Titulo: Paraguay Oral Research Titulo clave abreviado: PAOR Vol 1. N°1 Enero – Abril 2012 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Universidad Autónoma del Paraguay Facultad de Odontología Pierre Fauchard Colón 658 y Gral. Diaz 1053 Tel: (+595-21)-441-924 Asunción - Paraguay Editoras: Dra. Alma Elizaur (Brasil) Facultad de Odontología Ribeirão Preto Universidad de São Paulo São Paulo - Brasil Dra. Mirtha Perdomo Duarte (Paraguay) Facultad de Odontología Pierre Fauchard Universidad Autónoma del Paraguay Asunción - Paraguay Comite Editorial: Dra Carolina Ayala Haedo Dra Rossana Sotomayor Dra Patricia Escobar Docentes de Investigación: Dra. Carolina Ayala Haedo Dra. Rossana Sotomayor Dr. Marcelo Costa Dra. Inés Domenech Dra. Fernanda Aira Dra. Ninfa Jacquett Comité Revisor: Carlos Estrela ( Brasil) Erick Miranda Souza ( Brasil) Eduardo Lima Machado ( Brasil) Mario Roberto Leonardo( Brasil) Renato de Toledo Leonardo ( Brasil) Jesus Djalma Pecora ( Brasil) Valdir Muglia ( Brasil) Luis González Navarro ( Paraguay) Rodolfo Perruchino ( Paraguay) Carmen Espinola ( Paraguay ) David Ugarte ( Paraguay) Ivonne Garcia ( Paraguay) Raquel Fernandez ( Paraguay) Juan Pablo Penoni ( Paraguay) Lea Assed Becerra ( Brasil) Ninfa Jacquet (Paraguay) Teresa Chirife ( Paraguay) Valeria Pagnano ( Brasil) Jacqueline Orue de Cubilla ( Paraguay) Alderete ( Paraguay) Victor boettner ( Paraguay) Julian Ayala Arellano( Paraguay) Marcelo Costa (Paraguay) Diseño y Diagramación: Lic. Jorge González Bauzá Paraguay Oral Research La UAP es pionera en la búsqueda de conocimientos por medio de la investigación científica. Desde su creación trabajó en ese sueño, de formar profesionales con sentido crítico. Además de todo un programa innovador de formación profesional, por medio de un programa de iniciación científica, que fue todo un desafío, tanto para los docentes, como también para los jóvenes estudiantes. Así fuimos haciendo camino. Hoy contamos con cursos de post-grado de Maestría y Doctorado, a nivel académico, que forman el profesor universitario y un investigador científico. La UAP ya formó alrededor de cincuenta Masters en Rehabilitación Oral, Endodoncia, Operatoria Dental y Odontopediatría y está formando doctores en las mismas especialidades, en un total de cinco años de estudio e investigación. Para emprender esta trayectoria contamos con el apoyo de profesores investigadores de la Facultad de Odontología de Ribeirão Preto de Universidad de São Paulo, una de las mayores universidades de Latinoamérica, con la que firmamos convenio, lo que permitió nuestra formación principalmente en la investigación odontológica, abriéndonos para el mundo de la ciencia, disponiendo además de conocimientos, sus modernos laboratorios, donde nuestros alumnos de pre – grado, Masterado y Doctorado ya desarrollaron algunas de las tesis. Esto coloca a la Odontologia del Paraguay en el ámbito de la producción de conocimiento y no simplemente como repetidores. Hoy con el lanzamiento de la Revista “PARAGUAY ORAL RESEARH” on-line es un peldaño importantísimo para la investigación, no solamente de la UAP, sino para toda la odontología de nuestro país, pues será una forma de divulgar las investigaciones realizadas aquí y las de otros centros científicos del mundo. Es un gran desafío, considerando que la meta es colocar esta revista a un nivel de excelencia, que con seguridad dependerá de su cuerpo editorial crítico, su periodicidad y de los trabajos científicos publicados. Esto dará un impulso en la realización de investigaciones de alta calidad científica, ya que este deberá ser el principal criterio de aceptación de los trabajos. Dra. Alma Elizaur (Br) Editora Internacional Dra. Mirtha Perdomo (Py) Editora Nacional w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y EDITORIAL Paraguay Oral Research INDICE w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y ARTICULOS ORIGINALES/ ARTIGOS ORIGINAIS 1.FILTRACIÓN APICAL ENTRE DOS CEMENTOS SELLADORES: ACROSEAL Y SEALER 26 AIRA, MF; COSTA M; ESCOBAR,PM ;PERDOMO M;DOMENECH,MI...……………………5-10 2. VERIFICACIÓN DEL CLORO ACTIVO Y PH DE DIFERENTES SOLUCIONES DE HIPOCLORITO DE SODIO ENCONTRADAS EN EL MERCADO PARAGUAYO DAVALOS , SC; ESCOBAR PM; PERDOMO M.................................................................................11-15 3. DETERMINACION DE LOS FRACASOS EM LAS RESTAURACIONES COM AMALGAMA DE PLATA POR MEDIO DE LA EVALUACION DE SUS CARACTERISTICAS CLINICAS. MEZA O, GARCIA I ,OSORIO M...........................................................................................................16-22 4. EFECTO DE UN DENTIFRICO EXPERIMENTAL CONTENIENDO MICROPARTICULAS DE BIOSILICATO EN SUPERFICIE DE ESMALTE EROSIONADO IN VITRO: ESTUDIO COMPARATIVO-PINTADO K, TIRAPELI C, PANAZERI H, GAVA I, DUARTE...........................23-32 ARTICULOS DE REVISION / ARTIGOS DE REVISAO. 5. RELACION ENTRE ESTABILIDAD PRIMARIA Y TRATAMIENTO DE SUPERFICIES DE LOS IMPLANTES DENTALES. REVISION DE LA LITERATURA. SHIMANO A. ELIZAUR A, ARRICO F, CANDIDO DOS REIS A. .....................................................................................................33-41 RELATO DE CASOS CLINICOS/ RELATO DO CASO 6. RESTAURACIONES CON RESINA COMPUESTA EN EL SECTOR POSTERIOR CON LA TÉCNICA DIRECTA EN UNA CAVIDAD CLÁSICA Y EN UNA EXTENSA ABARCANDO UNA CÚSPIDE KEGLER E. ; ARCE J; SAMANIEGO M, LANDIVAR J, FERNANDEZ R...............42 PAOR V o l 1 - n ° 1 4 Paraguay Oral Research Aira,MF*; Costa, M**; Escobar Dávalos,PM***; Perdomo,M****, Domenech, MI***** * Especialista en Endodoncia UAP, Docente de la Catedra de Investigacion UAP. **Master en Endodoncia UAP, Especialista en Endodoncia UAP, Docente de la Catedra de Endodoncia I UAP, Docente del curso de posgrado de Endodoncia de la UAP *** Master en Endodoncia Sao Leopoldo Mandic Campinas, Especialista en Endodoncia Uninga Bauru, Docente de la Catedra de Endodoncia I UAP. **** Master en Endodoncia UAP, Especialista en Endodoncia UAP, Docente de la catedra de endodoncia UAP *****. Especialista en Endodoncia UAP, Docente de la Catedra de Investigacion UAP. RESUMEN: El propósito de este estudio fue evaluar el grado de filtración apical en piezas dentarias extraídas de dos cementos a base de hidróxido de calcio Acroseal de Septodont y Sealer 26 de Dentsply. Se utilizaron 24 raíces distales de molares inferiores divididas en cuatro grupos (n=10): dos grupos experimentales: G1-Sealer 26 (Dentsply Maillefer) y G2- Acroseal (Septodont), y dos grupos de control: grupo control positivo y grupo control negativo. Las raíces fueron instrumentadas y luego obturadas con la técnica de condensación lateral y sumergidas en tinta china color verde (NANKIN ACRILEX Taiwán) en compartimientos independientes por tres días para ser luego diafanizas y posteriormente fotografiadas con el Dino-Lite Plus Digital Microscope (AnMO electronic corporation. Taiwán) con una magnificación de 49 X. Fueron tomadas medidas con el Software DinoCapture Dedicated for DinoLite Digital Microscope Version 2.7.0.8 (AnMO electronic corporation. Taiwán) en milímetros para medir la penetración del colorante desde el punto más apical de la obturación hacia el más coronal. Fue utilizado test T-Students para análisis estadístico de muestras independientes demostrando que no existe diferencias estadísticamente significativas (p>0.05) entre los grupos. Podemos concluir que no encontramos diferencia en cuanto a la filtración apical entre los dos cementos estudiados Sealer 26 (Detnsply Maillefer) y Acroseal (Septodont). PALABRAS CLAVES: cementos endodónticos, Acroseal, Sealer 26, filtración apical. Introducción La re infección de los conductos radiculares es uno de los factores cruciales que influye en el resultado del tratamiento (11) Fernández et. al. En 1998 definen filtración apical como el movimiento de líquidos periapicales hacia el conducto en dientes despulpados con obliteración incompleta del conducto radicular, por lo PAOR V o l 1 - n ° 1 5 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y FILTRACIÓN APICAL ENTRE DOS CEMENTOS SELLADORES: ACROSEAL Y SEALER 26 APICAL LEAKAGE BETWEEN TWO SEALER: ACROSEAL AND SEALER 26 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research general mediante acción capilar, ya que existe el potencial de comunicación entre el espacio pulpar y el periapical, algunos investigadores señalan que la inflamación no ocurre a menos que las bacterias sean un cofactor, resultando importante sobre todo en los fracasos a largo plazo. (7) Existen varios métodos para probar el sellado apical in vitro: Pruebas de microfiltración marcada con tintes o colorantes, Filtración de bacterias, radioisótopos, Pruebas electroquímicas, fluorométricas, Microscopía electrónica de barrido. Wu et al. 1988 ante una retrospectiva de la literatura sobre estudios de infiltración, observaron que casi la mitad de los trabajos publicados en endodoncia se refería a ese tema, con resultados variados y contradictorios, como también la metodología utilizada. Se sabe que casi todos los cementos endodónticos permiten cierto grado de infiltración de colorantes. (3) Hovland & Dumsha consideran que la infiltración puede producirse en las interfaces del cemento con la dentina, del cemento con el cono, por entre el cemento endodóntico o por la disolución del mismo. De esa manera se puede entender que uno de los puntos críticos se encuentra en el cemento endodóntico. (4) El propósito de este estudio fue evaluar el grado de filtración apical de dos cementos selladores endodonticos a base de hidróxido de calcio que son el Sealer 26 y el Acroseal. También se introdujo en este estudio la utilización del Dino-Lite Plus Digital Microscope (AnMO electronic corporation. Taiwán) elemento que contribuye para realizar tomas a gran aumento y de una manera accesible y práctica. Material y Método Para la realización de este estudio se utilizaron 24 raíces distales de molares inferiores divididas en cuatro grupos(n=10): dos grupos experimentales: G1- obturadas con cemento Sealer 26 y G2- obturadas con cemento Acroseal y dos grupos de control: G3- control positivo y G4- control negativo. PAOR V o l 1 - n ° 1 6 Preparación de los conductos. Una vez localizado el conducto se comprobó la patencia con una lima K #10 (JOTA), hasta visualizar su salida a través del foramen apical, la longitud de trabajo del mismo fue tomada visualmente al realizar la patencia. La instrumentación fue realizada con la técnica escalonada, con limas manuales tipo K (JOTA) de acero inoxidable conicidad 0,02. Fueron utilizadas cuatro limas tipo K (#25, #30, #35, #40) para la preparación apical del conducto a longitud de trabajo y limas #45, #50 y #55 tipo k para el retroceso. Para la irrigación se utilizo hipoclorito de sodio al 2,5% 2 ml (marca Base Base) entre instrumento e instrumento y se utilizó EDTA-T al 17% (Fórmula & Ação) antes de la última irrigación. Se secó el conducto con puntas de papel absorbente del # 40 (META). Se verificó la patencia del conducto pasando de nuevo la lima K#10 a través del foramen, para asegurarse que el conducto no haya sido obliterado durante la instrumentación y continua permeable. Obturación de los conductos. Se prepararon los cementos, según las indicaciones del fabricante. Se coloco cemento a la punta del cono principal de gutapercha y se introdujo en el conducto hasta alcanzar la longitud de trabajo preestablecida. Luego se realizó la técnica de condensación lateral utilizando conos accesorios RS (META) y espaciador D (Dentsply Maillefer), hasta lograr una obturación que alcance el tercio cervical del conducto radicular. Se realizó el corte de la gutapercha coronal remanente aplicando calor mediante un condensador hasta la entrada del conducto. G1: Condensación lateral + Sealer 26 (Dentsply Maillefer). 10 piezas dentarias. G2: Condensación lateral + Acroseal (Septodont). 10 piezas dentarias. Una vez obturadas las raíces, se almacenaron en un ambiente seco durante un mes. Transparentación: Una vez cumplido este periodo de Paraguay Oral Research Las raíces fueron diafanizadas por desmineralización de 4 ml. de ácido Nítrico al 3% durante 72 horas. Luego se realizó la deshidratación, sumergiendo las piezas en alcohol metílico al 99.8% por 5 días, realizando cambios diarios. Finalmente, las raíces fueron transparentadas y mantenidas en salicilato de metilo, hasta ser evaluadas. También fueron realizados los controles negativo y positivo para cada unos de los cementos: G 3: Condensación lateral + Sealer 26 (Dentsply Maillefer). 1 pieza dentaria, barnizada hasta el ápice con barniz de uñas y cubiertas completamente con cera pegajosa. G 4: Condensación lateral + Acroseal (Septodont). 1 pieza dentaria, barnizadas hasta el ápice con barniz de uñas y cubiertas completamente con cera pegajosa. G 5: Condensación lateral + Sealer 26 (Dentsply Maillefer). 1 pieza dentaria. Sin barniz de uñas ni cera pegajosa. G 6: Condensación lateral + Acroseal (Septodont). 1 pieza dentaria Sin barniz de uñas ni cera pegajosa. programa se midió en milímetros, la penetración del colorante desde el punto más apical de la obturación hacia el más coronal. (Fig. 2). Fig.1 Fotografía tomado con el Dino-Lite Plus Digital Microscope a 49 X (AnMO electronic corporation. Taiwán) Fig. 2 Medición realizada desde el ápice a la porción mas coronal de filtración con el Software DinoCapture Dedicated for DinoLite Digital Microscope Version 2.7.0.8 (AnMO electronic corporation. Taiwan) Evaluación Para evaluar las muestras, se capturó una imagen de cada una de ellas mediante Dino-Lite Plus Digital Microscope (AnMO electronic corporation. Taiwán) con una magnificación de 49 X (Fig. 1). Las raíces fueron medidas con el Software DinoCapture Dedicated for DinoLite Digital Microscope Version 2.7.0.8 (AnMO electronic corporation. Taiwán). Con este Resultados La Tabla I muestra la filtración promedio (mm) en cada grupo de tratamiento, con sus respectivas desviaciones estándar. Se puede observar a simple vista que no hay diferencias aparentes entre los grupos estudiados. PAOR V o l 1 - n ° 1 7 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y tiempo, las raíces G1 y G2 se barnizaron con 2 capas de barniz de uñas a excepción del foramen apical y se sellaron con cera pegajosa (a excepción de los últimos 2 mm apicales). Luego las muestras se sumergieron en tinta china color verde (NANKIN ACRILEX) en compartimientos independientes por tres días. Se enjuagaron en agua corriente y se les retiró tanto la pintura de uñas como la cera pegajosa con una hoja de bisturí N° 15. Paraguay Oral Research Tabla I. Parámetros descriptivos de la: Filtración Apical (mm) w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y GRUPOS TTO SEALER26 ACROSEAL N Media (mm) .7728 .5819 10 10 Desviación estándar .64913 .67267 En la siguiente Tabla II se muestran los parámetros descriptivos de la longitud de las raíces de los grupos investigados. La prueba TStudents para muestras independientes, muestra que no hay diferencias estadísticamente significativas (p>0.05), entre las longitudes promedio de las raíces de los grupos de tratamiento. La prueba de Levene's tampoco arrojó diferencias estadísticamente significativa (p>0.05) entre las varianzas de las longitudes de la raíces, condición necesaria y suficiente para poder aplicar la prueba de comparaciones de medias. Tabla II. Parámetros descriptivos de la: Longitud de las raíces GRUPOS TTO SEALER26 ACROSEAL N Media (mm) 13.3000 14.1000 10 10 Desviación estándar 1.15950 1.79196 Gráfico 1. Parametros descriptivos de la filtración (mm) entre los grupos de tratamiento 16 13,3 14 14,1 12 10 8 Longitud (mm) 6 Filtración (mm) 4 2 0 0.77 0.58 SEALER26 ACROSEAL Discusión El propósito de este estudio fue evaluar PAOR V o l 1 - n ° 1 8 el grado de filtración apical en piezas dentarias extraídas (ex vivo) de dos cementos a base de hidróxido de calcio Acroseal de Septodont y Sealer 26 de Dentsply. Con las pruebas realizadas se observo que no existe diferencia estadísticamente significativa entre los cementos estudiados. Existiendo una filtración promedio en milímetros un poco mayor en el cemento Sealer 26 (Dentsply Maillefer) 0.7728 mm; que el cemento Acroseal (Septodont) 0.5819mm. Estos cementos son comúnmente utilizados en nuestro país, de manera que contamos con un elemento más a tener en cuenta a la hora de seleccionar alguno de ellos en nuestra práctica diaria. En el trabajo sobre microfiltración apical “in vitro” de dos cementos selladores, realizada por el Dr. Costa M.J. , en el cual fueron comparados el Sealer 26 y Endo CPM Sealer, el Sealer 26 presento una media de microfiltración apical de 1,1mm en tres días.(12) A diferencia del mismo, en este trabajo el Sealer 26 presento una media de filtración apical de 0,7728 mm en tres días. Pero ambos trabajos d emu es tr an q u e n o ex is te d if er en cia estadísticamente significativa entre los cementos estudiados. En conductos radiculares obturados con Sealer 26 Siqueira Junior y Garcia Filho 1994 observaron “in vitro” los menores promedios de infiltración en comparación a los que se observaron con el Sealapex y el CRCS, aunque no hubo diferencia estadísticamente significativa entre los materiales probados.(1) En comparación con dicho estudio, en este trabajo el Sealer 26 presento una media de filtración apical mayor que el otro cemento estudiado el Acroseal de la Septodont. Pero nuevamente ambos trabajos no presentan diferencia estadísticamente significativa entre los cementos estudiados. Wu et al. En 1988 ante una retrospectiva de la literatura sobre estudios de infiltración, observaron que casi la mitad de los trabajos publicados en endodoncia se refería a ese tema, con resultados variados y contradictorios, como también la metodología utilizada. Se sabe que casi todos los cementos endodónticos permiten cierto grado de infiltración de colorantes. (3) Por lo tanto ya es sabido que la técnica utilizada en este trabajo para verificar la filtración apical tiene sus limitaciones, pero a sus vez nos proporciona cierta tranquilidad saber que a pesar de las limitaciones de la técnica los cementos utilizados presentaron promedios de filtración en milímetros muy bajos. Conclusión De acuerdo con la metodología utilizada se puede concluir que: - El cemento Sealer 26 presentó una media de filtración apical de 0,7728 mm en tres días. - El cemento Acroseal presentó una media de filtración de 0,5819 mm en tres días. - La media del Sealer 26 fue mayor que la del Acroseal. - El porcentaje de filtración en el cemento Sealer 26 fue de 5,8% y el del Acroseal 3,9%. - El porcentaje de filtración fue mayor en el Sealer 26. - No hay diferencia estadísticamente significativa entre los dos cementos estudiados Sealer 26 (Dentsply Maillefer) y Acroseal (Septodont). Abstract The purpose of this study was to evaluate the degree of apical leakage in teeth extracted from two cements calcium hydroxide Acroseal Septodont and Sealer 26, Dentsply. We used 24 distal roots of mandibular molars divided into four groups (n = 10): two experimental groups: G1-Sealer 26 (Dentsply Maillefer) and G2Acroseal (Septodont), and two control groups: positive control group and control group negative. The roots were instrumented and then sealed with the lateral condensation technique and immersed in India ink green (NANKING Acrilex Taiwan) in separate chambers for three days only to be photographed diafanizas and then with the Dino-Lite Digital Microscope Plus (electronic corporation Anmo. Taiwan) with a magnification of 49 X. Measures were taken with DinoCapture Dedicated Software for Digital Microscope DinoLite Version 2.7.0.8 (Anmo electronic corporation Taiwan) in millimeters to measure the penetration of the dye from the most apical to most coronal seal. T-test was used for statistical analysis Students independent samples demonstrating that there are no statistically significant differences (p> 0.05) between groups. We conclude that there are difference in apical leakage between the two studied cements Sealer 26 (Dentsply Maillefer) and Acroseal (Septodont). Agradecimiento Mi más sincero agradecimiento al Dr. Eugenio Kegler por su aporte desinterado para la elaboración de este proyecto. Referencias 1. 2. 3. 4. Siqueira Jr, IF; Garcia Filho, P.F. Avaliação “in vitro” das propiedades seladoras de três cimentos endodônticos a base de hidróxido de calcio. Rev. Bras. Odont., v51, n1, 1994, p.37-40. Fidel RAS, Fidel SR, Spanó JCE, Barbin EL, Pécora JD. Tempo de endurecimento de algunos cimentos endodônticos que contém hidróxido de calcio. Rev. Odontol Bras Cent 1995; 05:15-17. Trope M, Chow E, Nissan R. In vitro endotoxin penetration of coronally unsealed endodonontically treated teeth. Endod Dent Traumatol 1995; 11:90-94. Huang TH, Kao CT. pH measurement of root canal sealers. J Endod 1998; 24:236-38. 5. Valois, CRA; De Castro, AJR; 2002 Comparasion of the apical sealing ability of PAOR V o l 1 - n ° 1 9 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research four root canal sealers. J. Bras Endod 3, 317 – 322 (In portugues) 6. Estrela C. Ciencia Endodóntica. Sao Paulo. Artes Médicas. 2004. 7. Pécora J.D. Novak Savioli R. Paschoal Vansan L. Gariba Silva Wanderle R. Ferreira da Costa. NOVO MÉTODO DE DIAFANIZAR DENTES. 2004. On line. D i s p o n i b l e e n : http://www.forp.usp.br/restauradora/Trabalh os/diafa.html#intr 8. Pécora J.D Manoel D. Sousa Neto. Materiais obturadores dos canais radiculares. 2 0 0 4 . D i s p o n i b l e e n : http://www.forp.usp.br/restauradora/matob.h tml Queiroz, Celso Emanoel de Souza et al. Evaluación de la citotoxicidad de dos cementos de endodoncia en una cultura de macrófagos. J. Appl. Oral Sci. [En línea]. 2005, vol.13, n º 3 [citado el 28.11.2010], p. 237-242. Disponible en: <http://www.scielo.br/scielo.php?script=sci _ a r t t e x t & p i d = S 1 6 7 8 77572005000300007&lng=en&nrm=iso>. ISSN 1678-7757 doi:. 10.1590/S167877572005000300007. Dultra Fábio, Barroso Juliana Machado, Carrasco Laise Daniela, Capelli Alexandre, Guerisoli Danilo M. Zanello, Pécora Jesus Djalma. Evaluation of apical microleakage of teeth sealed with four different root canal sealers. J. Appl. Oral Sci. [serial on the Internet]. 2006 Oct [cited 2011 Aug 09] ; 1 4 ( 5 ) : 3 4 1 - 3 4 5 . Av a i l a b l e f r o m : http://www.scielo.br/scielo.php?script=sci_a rttext&pid=S167877572006000500008&lng =en. De-Deus G, Branda˜o MC, Fidel RAS, Fidel SR. The sealing ability of GuttaFlowTM in oval-shaped canals: an ex vivo study using a polymicrobial leakage model. International Endodontic Journal, 40, 794–799, 2007. Costa Perdomo M.J., Microfiltración apical in vitro de dos cementos de obturación 9. 10. 11. 12. PAOR V o l 1 - n ° 1 10 de conductos radiculares. 2008. 13. Garcia LR, Consani S, Pires-de-Souza FP, de Almeida GL. In vitro analysis of the cement film thickness of two endodontic sealers in the apical region. Indian J Dent Res 2009;20:390 Paraguay Oral Research Verificación del cloro activo y pH de diferentes soluciones de Hipoclorito de sodio encontradas en el Mercado paraguayo. Davalos Frutos, S*; Escobar Davalos, PM**; Perdomo, M.*** *Especialista en Endodoncia UAP, Docente de la Cátedra de Endodoncia I UAP. ** Máster en Endodoncia Sao Leopoldo Mandic, Especialista en Endodoncia Uninga Bauru, Docente de la Cátedra de Endodoncia I UAP. *** Master en Endodoncia UAP, Especialista en Endodoncia UAP. Docente de la Catedra de Endodoncia III UAP. RESUMEN El objetivo del trabajo fue verificar la concentración de cloro activo y del pH de 25 soluciones de hipoclorito de sodio de diferentes marcas comerciales y diferentes concentraciones existentes en el mercado paraguayo. Cinco de estas soluciones fueron adquiridas en casas dentales y veinte de supermercados ambos de la ciudad de Asunción. La concentración de cloro activo fue verificada a través de titulación yodométrica y el pH a través de un aparato llamado pH-metro en el Instituto Nacional de Tecnología Normalización y Metrología, AsunciónParaguay. Los valores encontrados fueron anotados y comparados con los valores existentes en los rótulos de los productos. De acuerdo a los datos estadísticos recolectados hubo diferencia estadística significativa entre la media de las concentraciones de hipoclorito de sodio especificadas por el fabricante y la media de las concentraciones obtenidas en nuestra investigación. Del total de las marcas comerciales (25 muestras) , el 92 % no presentaba la concentración de hipoclorito de sodio especificada por el fabricante (23 muestras), 8% presentó la misma concentración especificada por el fabricante (2 muestras); 72% presentaron concentración inferior a la especificada por el fabricante ( 18 muestras) y 20% presentaron concentración superior a la especificada por el fabricante( 5 muestras).Todas las marcas comerciales presentaron pH alcalino con un promedio de pH 11,9. Pero ninguna presenta su pH en el envase. Palabras Claves: Hipoclorito de Sodio – Titulación yodométrica – pH . Introducción. La solución de hipoclorito de sodio, en sus diferentes concentraciones, constituye la primera elección mundial como substancia irrigadora de conductos radiculares (1,2) En Endodoncia la solución de hipoclorito de sodio es utilizada en concentraciones que varían de 0,5% 5,25%. Sin embargo por ser una solución clorada presenta elevada inestabilidad afectada por factores como temperatura, presencia de luz, pH, Presencia de iones metálicos, presencia de materia orgánica, concentración, tiempo de almacenamiento y contacto con el aire. (1, 3, 4, 5, 6,7, 8) La inestabilidad natural de los compuestos clorados asociados a la negligencia de sus fabricantes (Uso de agua inapropiada, almacenamiento inadecuado) puede llevar la disminución del contenido de cloro libre y como consecuencia la descomposición precoz del producto como consecuencia de la pérdida del poder bactericida. (9) PAOR V o l 1 - n ° 1 11 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Determination of Active Chloride content In Different Solutions Sodium Hypochlorite In Paraguay's Market. Paraguay Oral Research Del total de las marcas comerciales (25 muestras), el 92 % no presentaba la concentración de hipoclorito de sodio especificada por el fabricante (23 muestras), 8% presentó la misma concentración especificada por el fabricante que fueron las marcas Pino Leche y Lava1000; 72% presentaron concentración inferior a la especificada por el fabricante (18 muestras) y 20% presentaron concentración superior a la especificada por el fabricante. (5 muestras). Todas las marcas comerciales presentaron pH alcalino con un promedio de pH 11,9. Pero ninguna presenta su pH en el envase. Los resultados se pueden observar en los cuadros 2 y 3. Figuras 1 y 2. Cuadro 2. Concentraciones de Hipoclorito de Sodio según el fabricante y según el informe del INTN. Cuadro 4. Test ”t” student. Fig 1. Concentracion de Hipoclorito de sodio según el fabricante y según el informe del INTN. Fig 2. pH de las soluciones analizadas en el INTN. Cuadro 3. pH de las soluciones analizadas en el INTN Discusión El preparo químico - mecánico ocurre de manera interactiva entre instrumentos y una substancia química auxiliar con propiedades de preferencia PAOR V o l 1 - n ° 1 13 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Resultados w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research capacidad antimicrobiana, capacidad de disolver tejidos, poder de limpieza, buena tolerancia de los tejidos periapicales. (10) La solución más utilizada todavía es el Hipoclorito de Sodio por el alto poder de disolución de tejidos (7) y su alta capacidad bactericida (14, 15, 16) Las concentraciones son variadas, siendo las utilizadas en la práctica clínica desde 0,5% a 5,25% aunque existen trabajos de su uso hasta 10% (17). Una vez que el odontólogo defina la solución de hipoclorito de sodio a utilizar, se presenta otro problema: la calidad del producto a utilizar. No siempre la cantidad de cloro residual libre existente en el momento que compramos es el mismo para su utilización. Esto se debe a la inestabilidad química del hipoclorito de sodio. Es por eso la importancia de mantener las concentraciones para obtener una buena desinfección y con eso aumentar las chances de alcanzar el éxito endodóntico; estudios en la literatura buscan minimizar los factores que contribuyen a la inestabilidad de la solución entre ellos factores intrínsecos y extrínsecos como: La temperatura elevada, el envase, el contacto con el dióxido de carbono atmosférico y la presencia de luz ( 8) Pero pocos trabajos analizan la calidad de la solución ya existente en el frasco a la hora de comprar que anularían nuestros intentos por mantener la concentración adecuada. Diversos autores estudiaron la estabilidad química de las soluciones de hipoclorito de sodio y la inestabilidad del cloro es extremadamente preocupante sobre todo entre productos comerciales. (10) La evaluación del pH de las soluciones experimentales pareciera ser importante para mantener la estabilidad de la solución, recomendando que la solución de hipoclorito de sodio debe presentar un pH alcalino (encima de 10) para mayor estabilidad y liberación lenta de cloro (7,8) Contrariando a Macedo (18) que revelaron que el pH no muestra relación con la velocidad de reacción de hipoclorito de sodio, siendo solo la concentración, tiempo de exposición y activación factores que influyen en la velocidad de reacción. Nuestros resultados demostraron que todas las soluciones analizadas presentaron pH alcalino, en su mayoría cerca de 12. Estudios revelan que las soluciones disponibles en el comercio especializado o en los consultorios odontológicos presentan concentraciones menores de lo que indica en el envase (10) siendo recomendados el uso de soluciones recién preparadas para evitar que las concentraciones de las preparaciones obtenidas PAOR V o l 1 - n ° 1 14 coincidan con los valores esperados. (3). Nuestros resultados revelaron que de las 26 soluciones analizadas solo 2 coincidieron, 19 se presentaron menores y 5 mayores a lo que indica el envase. Conclusión De acuerdo a los análisis de datos se concluye que: - Hay diferencia significativa entre la media de las concentraciones de hipoclorito de sodio especificadas por el fabricante y la media de las concentraciones obtenidas en la investigación. Pino Leche al 4% y Lava1000 al 2,5% fueron las únicas soluciones que presentaron la concentración igual a la obtenida por el informe del INTN. - Todas las soluciones presentaron pH alcalino alrededor de 12. Se sugiere un mejor control de calidad de las soluciones de hipoclorito de sodio encontradas en el mercado nacional, sobretodo de las soluciones adquiridas en casas dentales. Abstract The aim of this study was to verify the concentration of active chlorine and pH of sodium hypochlorite solutions of different brands and concentrations on the market. Five of these solutions were obtained in dental markets and twenty in supermarkets, all of them in Asuncion- Paraguay. The chlorine concentrations was verified trough iodometric titration and pH through a pH meter device in the National Institute of Standards and Technology in Asuncion-Paraguay. The values were compared with the existing values in the labels of each products. According to statistical data collected there was statically difference between the mean concentrations of hypochlorite sodium specified by the manufactures and the average concentrations obtained in our study. Of all the commercial brands (25 samples), 92% had no concentration specified by the manufacture (23 samples), 8% had the sample concentrations specified by the manufacture (2 samples) 72% had less than the specified by the manufacture (18 samples) and 20% had higher than specified by the manufacture (5 samples) All the brands showed an alkaline pH with an average pH 11,9. But none was specified in the sample. Paraguay Oral Research 1.JOHNSONS B. Y REMEIKIS N. Effective shelf-life of prepared sodium hypochlorite solution. J Endod. 1993. 19; 1: 40-43 2.ESTRELA C. Hipoclorito de Sodio In: Ciencia Endodôntica. Sao Paulo: Artes Medicas, 2004, 415-455. 3. PECORA JD et al Estudo sobre a sobrevida da solução Dakin. Rev. Odontol USP. 1987.1;1:3-7. 4.PISKIN B. Y MURAT T. Stability of various Sodium Hypochlorite Solutions. J endod. 1995. 21; 5:253-255. 5.NICOLETTI M.A et al . Hipoclorito de sodio: Analise de fontes promotoras de inestabilidade química. Rev. Inst. Ciênc.Saude.1997.15;1:23-27 6.SÓ MVR et al. Efeito da temperatura, luminosidade e forma de armazenamento na estabilidade da solução de h ip o clo r ito d e s ó d io a 1 , 0 % . R ev. Fa c. P. Alegre,2002.43;2:14-17. 7.SIQUEIRA E., NICOLETTI MA., BONBANA A.,SANTOS M. Influence of pH on the chemical stability of o,5% Sodium hypochlorite solution. 2002.9; 3:207-211. 14. FERRARI PHP, CAI S, BOMBANA AC. Effects of endodontics procedures on Enterococci, enteric Bacteria and yeast in primary endodontic infections. Int End J.2005.38:372-80. 15. RADCLIFFE CE.POTOURIDOU L.QURESHI r, HABAHBEH N. QUALTROUGH A. WORTHINGTON H et al. Antimicrobial activity of varying concentration of sodium hypoclorite in the endodontic microorganisms Actinomyces israelli. E. naeslundii. Candida Albicans and Enterococcus Faecalis. Int End J.2004.37:438-46. 16. VIANNA ME HORZ HP, GOMEZ VPFA, CONRADS G. In vivo evaluation of microbial reduction after chemomechanical preparation of human root canals containing necrotic pulp tissue. Int End J.2006.39:484-92. 17. NAKAMURA H, KATSUHISA A, FUJITA H, NAKAZATO H, NISHIMURA Y. FURUSE Y et al. The solvent action of sodium hypoclorite and bovine endo collagen, bovine pulp and bovine gingiva. OOO. 1985.60;322-6 18. MACEDO RG. WESSELINK PR, ZACCHEO , FANALI D & VAN DER SLUI LW. Reaction rate of NaOCl in contact with bovine dentine: effect of activation, exposure time, concentration and pH. Int. End J. 2010.June 1-5. 8.ESTRELA CRA, ESTRELA C, CARVALHO AL, GONALLA ANPF, PECORA JD. Controle microbiano e químico de diferentes soluções de hipoclorito de sódio. Rev Odontol Bras Central 2002;11:16-21. 9. NICOLETTI MA, MAGALHAES JF. Influencia del envase y de factores ambientales en la estabilidade de la solucion de Hipoclorito sódico. Bol. Ofic. Param.1996.121:4:301-309. 10. PECORA JD et al Verificação do teor de cloro ativo de diferentes marcas de líquidos de Dakin encontrados no mercado. Rev. Odontol USP. 1988.2;1:10-13. 11. VARGAS MC Verificação do teor de cloro ativo em soluções comerciais de hipoclorito de sódio. Dissertação de mestrado Faculdade de Odontologia da Universidade Federal de Pernambuco, Camagibe, PE 2000. 12. VENTURA ACA. Et al Determinação do teor de cloro ativo nas soluções de hipoclorito de sódio: Visão atual do problema. Ver. Pau. Odontol, São Paulo 2002.4:24-8. 13. MADEIROS GHF. Avaliação química dos parâmetros físico-químicos de diferentes substancias empregadas durante a terapia endodóntica. Dissertação de mestrado em Odontologia, Universidade Luterana do brasil, Canoas, 2005. PAOR V o l 1 - n ° 1 15 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Referencias Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y DETERMINACIÓN DE LOS FRACASOS EN LAS RESTAURACIONES CON AMALGAMA DE PLATA POR MEDIO DE LA EVALUACIÓN DE SUS CARACTERÍSTICAS CLÍNICAS DETERMINATION OF THE FAIRLURE OF THE SILVER AMALGAM RESTORATIONS THROUGH THEIR CLINICAL EVALUATION Meza O*, García I**, Osorio M***. * MS, Universidad Autónoma del Paraguay “Pierre Fauchard”, Profesor Adjunto, Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay. **MS, Universidad Autónoma del Paraguay “Pierre Fauchard”, Profesora Titular, Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay. *** Directora del Departamento de Investigación, Universidad Nacional de Asunción, Facultad de Odontología, Asunción, Paraguay. RESUMEN: El presente estudio fue realizado para determinar los fracasos en las restauraciones de amalgama de plata por medio de la evaluación de sus características clínicas. Para ello, se procedió a la evaluación clínica y radiográfica de 218 restauraciones de amalgama de plata en 65 pacientes (20 a 60 años) (edad promedio 37 años) portadores de dichas restauraciones (Clase 1= 168, Clase 2= 50). Los pacientes fueron consultados sobre la fecha aproximada en que le fueron realizadas las restauraciones. Los fracasos de las restauraciones fueron evaluados según criterios modificados en 6 parámetros; 1: filtración marginal (FM), 2: fractura de la restauración (FR), 3: fractura del diente (FD), 4: caries secundaria (CS), 5: sensibilidad (S), 6: corrosión (C). La longevidad media de las restauraciones fue de 16 años. Los datos fueron digitados y analizados en una planilla electrónica en el programa Microsoft Office Excel 2007. El porcentaje de restauraciones exitosas fue de 73,4 (n= 160). Las causas de fracaso expresadas en cantidad y porcentaje de todos los criterios fueron: CS n= 50 (35,2%), FM n= 48 (33,8%), C n= 24 (16,9), FR n= 9 (6,3%), S n= 8 (5,6%), FD n= 3 (2,1%). Las principales causas de fracaso fueron Caries Secundaria, Filtración Marginal y Corrosión. La menor frecuencia de fracaso fue observada en el parámetro Fractura del Diente. Mayores fracasos se observaron en restauraciones Clase 2 (53,4%, n= 31), encontrándose en las mismas un 71,4%, n= 15, de restauraciones con 3 criterios de fracaso. En Clase 1 (46,6%, n= 27) predominaron los fracasos con dos criterios, n= 11, 47,8%. Mayor número de fracasos se observó en molares inferiores con restauraciones Clase 1 (n= 12, 14,3%), y menor número en premolares superiores con restauraciones de Clase 1 (n= 3, 30,0%) PALABRAS CLAVES: cementos endodónticos, Acroseal, Sealer 26, filtración apical. PAOR V o l 1 - n ° 1 16 Introducción La amalgama de plata es un material que sigue siendo muy utilizado en nuestro medio a pesar de que últimamente es rechazada por parte de los pacientes por su falta de estética. Por otro lado, a nivel asistencial igualmente prevalecen los criterios de durabilidad y economía.(1) Se debe considerar que el nivel socio económico de la población paraguaya no escapa a la necesidad de contar con un material de obturación de bajo costo pero de excelentes propiedades para su utilización en dientes posteriores, y que responde a las necesidades locales. En la práctica profesional diaria no es raro encontrar restauraciones con este material que distan mucho de ser excelentes, razón por la cual se consideró muy importante la realización de este estudio en la que se evaluaron las causas más frecuentes de los fracasos de estas restauraciones, además no existe ningún estudio de este tipo en el país, y considerando que podría dar respuesta a una necesidad local de contar con un material que por su costo-beneficio, es y seguirá siendo un material de restauración muy utilizado. Según Llodra (1996) en Revelles (2002) la valoración del éxito o fracaso de una restauración no es tarea sencilla. Un primer enfoque podría ser la edad de las restauraciones que necesitan ser sustituidas mediante estudios transversales. Como segunda opción se puede obtener el número de restauraciones con éxito a lo largo del tiempo y estimar la supervivencia. En tercer lugar mediante estudios transversales se puede conocer la edad de las restauraciones intactas (estudios de persistencia).(8) Este trabajo consistió en evaluar el estado de las restauraciones de amalgama de plata, realizadas en premolares y molares de 217 casos, como número mínimo, identificando las causas más frecuentes de los fracasos, con el propósito de tomar medidas tendientes a solucionarlos. Desde el punto de vista clínico, la mayoría de los fracasos que se observan en las restauraciones son debidos a una mala elección del caso para utilizar este material, ya que no todos están indicados para el mismo, sea por la extensión o la ubicación de las lesiones cariosas. También se une a estos factores la preparación cavitaria deficiente, la inadecuada manipulación del material, ya sea por mala dosificación de la aleación y el mercurio, la mala mezcla de los mismos y la inserción inadecuada dentro de la cavidad preparada. A todo esto se suma un mal tallado y pulido final de la restauración.(4) La duración de la amalgama es algo que sobresale sobre los demás materiales utilizados en odontología. Akerboom y cols., en 1993, evaluaron amalgamas a los 10 años de su colocación y establecieron dos tipos de fallas: falsas y verdaderas. Las verdaderas eran debidas a técnica restaurativa deficiente, y las falsas, a otras causas. Solamente, el 8,5% de las restauraciones tuvo que ser reemplazado, en su mayoría por fallas verdaderas.(9) Según la declaración de consenso de la OMS sobre la amalgama dental, aunque mucha de la investigación se ha centrado en la elaboración de materiales restauradores dentales, no existe otro material de obturación directa con tan amplias indicaciones para su uso, de tan fácil manipulación y que tenga las buenas propiedades físicas de la amalgama dental.(6) Dado que no existen en Paraguay datos que expliquen las causas de fracasos en restauraciones de amalgama, se plantea el presente estudio con el objeto de realizar algunas evaluaciones clínicas de los fracasos en la utilización de este material y sus posibles causas en pacientes en cuyas bocas existen restauraciones hechas con el mismo. Material y Métodos. Se realizó un estudio observacional descriptivo de corte transverso para determinar la frecuencia y las características del fracaso de las restauraciones realizadas con amalgama de plata en pacientes que tenían este tipo de material restaurador. El universo de estudio estuvo constituido por pacientes entre 20 a 60 años, de ambos sexos que contaban como mínimo con un diente permanente restaurado con amalgama de plata, que concurrieron para PAOR V o l 1 - n ° 1 17 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research el tratamiento de sus problemas dentales a la Cátedra de Operatoria Dental II Curso del Tercer Año de la Facultad de Odontología de la Universidad Nacional de Asunción, la Cátedra de Operatoria Dental II Curso del Tercer Año de la Facultad de Odontología de la Universidad del Norte y la Cátedra de Operatoria Dental I Curso del Tercer Año Facultad de Odontología de la Universidad Autónoma de Asunción, durante los meses de noviembre del 2007 y marzo a agosto del 2008, en los que se determinó: La presencia de filtración marginal (FM), la presencia de caries secundaria (CS), la presencia de fractura de la restauración (FR), la presencia de fractura del diente (FD), la presencia de sensibilidad (S), la presencia de corrosión superficial (C). La muestra quedó conformada por 65 individuos, quienes al momento de concurrir al servicio de asistencia odontológica contaban como mínimo con un diente permanente restaurado con amalgama de plata y manifestaron estar conformes de participar del estudio. Las restauraciones de amalgama fueron evaluadas de manera directa. Se procedió a la limpieza de las restauraciones con cepillito de Robinson y piedra pómez para su posterior tinción colorimétrica con una sustancia colorante utilizada para la detección de caries (rojo ácido al 1%), por 10 segundos. La evaluación de las restauraciones se realizó clínicamente, utilizando una sonda exploradora número 47 adulto de la marca “JON” y espejo bucal plano, en las unidades dentales disponibles en las facultades. Se tomaron radiografías de aleta de mordida y también fotografías, con una cámara digital SONY Cyber Shot, de todos los casos observados.(fig.1,2 y 3) Fig. 1. Materiales utilizados PAOR V o l 1 - n ° 1 18 Fig. 2. Rx de Aleta de Mordida Fig. 3. Fotos de restauraciones Las restauraciones fueron evaluadas en los siguientes 6 criterios: ? Se consideró filtración marginal cuando al aplicar el colorante detector de caries sobre el diente, este quedó teñido en la interface diente-restauración, y con la sonda exploradora, este quedó trabada. ? Se consideró fractura de la restauración cuando se observó una pérdida del material restaurador. ? Se consideró fractura del diente cuando se observó una pérdida del tejido dentario. Se consideró caries secundaria cuando se observó radiográficamente zonas radiolúcidas debajo o en los bordes de la restauración. ? Se consideró diente sensible cuando a la inspección, este respondió positivamente al test del frio y a la percusión vertical. ? Se determinó visualmente si existe o no corrosión superficial de la restauración. A partir de la valoración de estos criterios las restauraciones fueron categorizadas como: -Exitosas: ausencia de los criterios señalados; -Fracasadas: aquellas que presentaron uno o más criterios de evaluación. Se consultó la fecha de permanencia aproximada de las restauraciones en boca (antigüedad de la restauración). Para la recolección de los datos se procedió a sentar al paciente en el sillón dental con el respaldo en un ángulo de 90º, para la buena observación por parte del operador, de los dientes que fueron evaluados, ubicándose el mismo frente al paciente. Se requirió de una buena iluminación del campo operatorio, de un auxiliar que separe los labios del paciente con un separador y otro que fue asentando los datos en la ficha. Hubo un solo observador o evaluador. Los resultados de la evaluación de cada diente se registraron en una ficha de recolección de datos especialmente diseñada para el presente estudio. Los datos registrados en las fichas, fueron digitados en una planilla electrónica en el programa Microsoft Office Excel 2007 donde las variables estaban representadas en las columnas y los individuos en las filas. De la base de datos obtenida, se realizaron tablas de frecuencias absolutas y porcentuales; como así también tablas de contingencias, los cuales permitieron un mejor análisis y comprensión de los resultados. Los datos previamente tabulados fueron analizados mediante estadística descriptiva. Considerando un estudio realizado en el año 2005 (Moncada) en 213 restauraciones de amalgama, donde el porcentaje de restauraciones aceptadas clínicamente fue de 82,6%, frente al 17,4% de fracasos, no fue necesario aplicar una fórmula para determinar el tamaño de la muestra, pues se trabajó con todos aquellos pacientes que consultaron en el periodo de tiempo establecido para la realización del trabajo de campo, sin aplicar ninguna técnica de muestreo en la selección de la unidad de análisis. Por lo cual el estudio se constituye en un estudio no probabilístico, con énfasis en el muestreo de casos consecutivos a partir del cumplimiento de los criterios de inclusión. Se le informó al paciente su estado de salud bucal y de sus restauraciones. Los datos personales de cada paciente fueron confidenciales así como el resultado de cada restauración observada. Las observaciones fueron realizadas por una sola persona, en este caso, el investigador de este estudio. Resultados. Se evaluaron 65 pacientes de 20 a 60 años, (edad promedio 37 años), de ellos el 64,6% (n= 42) mujeres y el 35,4% (n= 23) hombres, portadores de 218 restauraciones de amalgama (Clase 1= 168 y Clase 2= 50). De las 218 restauraciones de amalgama evaluadas, el porcentaje de restauraciones aceptadas clínicamente fue de un 73,4% frente al 26,6% de fracasos. El mayor porcentaje de fracasos se observó en restauraciones de Clase 2. Las principales causas de fracasos de restauraciones de amalgama fueron la caries secundaria (35,2%) y la filtración marginal (33,8%). La menor frecuencia de fracaso fue observada en el parámetro fractura del diente (2,1%). El 26,6% (58/218) de las restauraciones evaluadas presentaban algún tipo de fracaso. De éstas el 53,4% (31/50) corresponden a la clase 2 (Tabla 1). Resultados bastante semejantes a un estudio similar realizado en Chile, en el cual el porcentaje de fracasos fue del 17,4%, correspondiendo un mayor porcentaje de fracasos a la clase 2 (59,5%). El 69% de los fracasos en las restauraciones se debieron a la presencia de caries secundaria (35,2%) y filtración marginal (33,8%). El criterio que con menor frecuencia se encontró fue la fractura dentaria (2,1%) (Tabla 2). También bastante semejantes al estudio similar realizado en Chile, en el cual hubo un 62,1% de fracasos, correspondiendo un 35,1% a caries secundaria y un 27,0% a filtración marginal. Sin embargo en este estudio la sensibilidad fue la razón menos frecuente de fracaso, 2,7%. En la PAOR V o l 1 - n ° 1 19 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research evaluación de la prevalencia por Clase se observó que la fractura de la restauración fue mayor en Clase 1 en tanto que los demás criterios fueron más prevalentes en la clase 2, a excepción de la corrosión que se presentó en igual proporción para ambas clases (tabla 3). El 75,9% de las restauraciones presentaban entre 2 y 3 criterios de fracaso. El 84,5% de las restauraciones presentaron más de 1 criterio de fracaso. El 83% de las restauraciones observadas correspondieron a los molares. Al evaluar el porcentaje de fracasos de acuerdo a las piezas dentarias se pudo valorar que los premolares presentaron mayor proporción que los molares. Al evaluar los fracasos por arcada se observó que la arcada superior presenta una proporción 4,7 mayor a la inferior. El 62% de las restauraciones Clase 2 resultaron con fracaso, en tanto que solo el 16,1% de las restauraciones Clase 1 no fueron exitosas. (Tabla 4). A partir de las restauraciones observadas según el sexo de los pacientes se pudo apreciar que las mujeres presentaron mayor proporción de restauraciones con algún criterio de fracaso. Tabla 1 .Evaluación de restauraciones según categorías por clase. Clase 2 Total Categorías deClase 1 evaluación Número% Número % Número % Exitos 141 88,1 19 11,9 160 73,4 Fracasos 27 46,6 31 53,4 58 26,6 Total 168 77,1 50 22,9 218 100,0 Tabla 2 . Proporción de restauraciones con fracaso según criterios de evaluación. Criterios de evaluación Número Filtración marginal 48 Fractura de la restauración 9 Fractura del diente 3 Caries secundaria 50 Sensibilidad 8 Corrosión 24 Total 142 % 33,8 6,3 2,1 35,2 5,6 16,9 100,0 Tabla 3 .Prevalencia de criterios de fracaso según clase Clase 1 Clase 2 Total Número % Número % Número % Filtración marginal 19 39,6 29 60,4 48 33,8 Fractura de la restauración 5 55,6 4 44,4 9 6,3 Fractura del diente 1 33,3 2 66,7 3 2,1 Caries secundaria 20 40,0 30 60,0 50 35,2 Sensibilidad 2 25,0 6 75,0 8 5,6 Corrosión 12 50,0 12 50,0 24 16,9 Total 59 41,5 83 58,5 142 100,0 Causas PAOR V o l 1 - n ° 1 20 Tabla 4. Fracasos de restauraciones según clase. Éxitos Fracasos Total Número % Número % Número % Clase 1 141 83,9 27 16,1 168 77,1 Clase 2 19 38,0 31 62,0 50 22,9 Total 160 73,4 58 26,6 218 100,0 Clase Discusión. La metodología utilizada en este trabajo de investigación estuvo basada en un estudio realizado por Moncada y cols. del Área de Operatoria Dental, Dpto. de Odontología Restauradora, Universidad de Chile (2005) y por Mjör (1981) con algunas modificaciones. En este último ni en las anteriormente realizadas existió calibración para el diagnóstico de caries, ni se explica que criterio se utilizó para restauraciones fracasadas. En este estudio, los criterios que se tuvieron en cuenta fueron filtración marginal, fractura de la restauración, fractura del diente, caries secundaria, sensibilidad y corrosión. Todos estos criterios también fueron tenidos en cuenta en el estudio de Moncada y cols. a excepción de la corrosión, criterio empleado solo en este estudio. El menor porcentaje de fracaso se observó en la fractura de la pieza dentaria, a pesar de haber sido observados pacientes con problemas parafuncionales. La sensibilidad poco frecuente también coincide con estudios anteriores así como en la mayor frecuencia de la misma en restauraciones de Clase 2. Esto se debería a una mala técnica de higiene del paciente en los espacios interproximales que conllevan a la aparición de caries secundaria en esa zona. La alta prevalencia de fracasos en restauraciones Clase 2 (53,4%), muy semejante al estudio de Moncada (59,5%), debería llamar la atención de los profesionales y profundizar en el estudio sobre las causas reales del mismo, para saber si son factores inherentes al profesional, al paciente o al propio material. En cuanto a la edad mediana o antigüedad de las restauraciones se ha observado un promedio de tiempo de permanencia de las restauraciones de 16 años. La edad mediana de las restauraciones ha sido utilizada en varios estudios anteriores realizados sobre el tema, que manifestaron una edad mediana de no más de 5 a 8 años, hasta 9 como máximo, mucho menor al observado en este estudio. Existen muchos factores que pueden influenciar sobre la longevidad de las restauraciones, uno de ellos y el más importante en nuestro medio es la mala higiene bucal de los pacientes, por sobre otros como la preparación cavitaria deficiente y la mala técnica de manipulación del material, inherentes estos al profesional. El hecho de que las restauraciones, sean cual fuere del material que hayan sido realizadas, fallen, es un hecho indiscutible, y las razones de su fracaso son temas muy subjetivos ya que no existen estudios a largo plazo sobre el comportamiento de los materiales restauradores en boca, realizados de manera apropiada, para establecer específicamente cual fue la razón por la que las mismas fracasaron en caso de que haya sido así. El problema es que estos seguimientos son difíciles de realizar, por la parcialidad en la selección de los pacientes y la variación entre uno y otro, que otra vez, pueden dar resultados subjetivos. Conclusión. El porcentaje de fracasos de las restauraciones de amalgama fue del 26,6% con una longevidad media de 16 años. Las principales causas de fracaso fueron la caries secundaria y la filtración marginal. La menor frecuencia de fracaso se observó en los parámetros de fractura del diente y sensibilidad. Mayores deterioros se observaron en restauraciones de Clase 2 que presentaron tres o más criterios de fracaso. También se observó mayor porcentaje de fracasos en premolares. Abstract. The aim of this study was to determine failures in amalgam restorations evaluating its clinical characteristics. There for, we proceeded to do the clinical and radiological evaluation of 218 amalgam restorations in 65 patients (20 to 60 years) (37 years average age) carrying Class 1 restorations:168, Class 2 restorations:50 . Patients were consulted the approximate date in which restorations were made. The restoration failures were evaluated by modified criteria in the following six parameters; 1: marginal filtration (MF), 2: restoration fracture (RF), 3: tooth fracture (TF), 4: secondary caries (SC), 5: sensitivity (S), 6: corrosion (C). The average longevity of restorations was of 16 years. The data was digitalized and analized in a Microsoft Excel 2007 electronic schedule. The percentage of successful restorations was of 73,4 (n:160) The failure reasons expressed in quantity and percentage were : SC n= 50 (35,2%), MF n=48 (33,8%), C n=24 (16,9%), RF n=9 (6,3%), S n=8 (5,6%), TF n=3 (2,1%). The main failure reasons were Secondary Caries, Marginal Filtration and Corrosion. The minimum failure frequency was observed in the Tooth Fracture parameter. Greater failures were observed in Class II (53, 4 %, n: 31) with 71,4%, n= 15 of restorations having 3 failure parameters. In Class I (46,6%, n= 27) two failure parameters predominated, n= 11, 47,8 % restorations. Mayor number of failures were observed in lower molars with Class 1 (n=12, 14,3%) and a lower number in upper bicuspids with Class 1 restorations (n=3, 30,0 %) Referencias. 1. Amalgama. Un material de ayer? D i s p o n i b l e e n : http://www.odontologiaholística.org.ve/amal gama.html. (Consultado en 16-07-2007) 2. Barrancos Mooney, Julio. Operatoria Dental: Restauraciones. Bs.As. Panamericana. 1º Edición 1981 – 1988. 3. Barrancos Mooney, Julio. Operatoria Dental: Integración clínica. Julio Barrancos Mooney. Bs.As. Panamericana. 4º Edición 2006 4. CDA (Asociación Dental de California) Amalgama es un material seguro y duradero que se utiliza para las restauraciones. D i s p o n i b l e e n : http://www.cda.org/popup/Amalgam_Spanis h. (Consultado en 13-07-2007) PAOR V o l 1 - n ° 1 21 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y 5. Espías Gómez A. Estado actual de los potenciales efectos de la amalgama dental en la salud. Disponible en: http://www.consejodentistas.org/informació n_ama.php. (Consultado en 16-07-2007) 6. FDI. Declaración de la OMS sobre la amalgama dental. Disponible en: http://www.consejodentistas.org/informació n_ama.php. (Consultado en 16-07-2007) 7. Lanata, Eduardo Julio. Operatoria Dental: Estética y adhesión. Bs. As. Grupo Guía Editores. 2005. 8. Llodra Calvo J C. Análisis de la vida media de las restauraciones dentales y principales causas de fracaso: una revisión bibliográfica. Disponible en: http://www.consejodentistas.org/informació n_ama.php. (Consultado en: 16-07-2007) 9. Materiales Dentales. Amalgama dental. Algunas consideraciones técnicas. Tribuna Odontológica, Programa de actualización basado en la evidencia. 2004; 1 (4). D i s p o n i b l e e n : http://www.medilegis.com/BancoConocimie nto/O/Odontologica-v1n4materiales/materiales.htm. (Consultado en 16-07-2007) 10. Quesada Álvarez C. Análisis comparativo de la microdureza Rockwell superficial y Vickers en diferentes composites con esmalte y dentina natural. Disponible en: http://www.odontologos.com.co/voco/voconews /voconews.htm. (Consultado en: 13-072007) 11. Revelles Suárez F. Restauraciones dentales en escolares del distrito Sanitario Alcalá la Real-Martos. Año 2002. Disponible en: h t t p : / / w w w. d b . d o y m a . e s / c g i bin/wdbcgi.exe/doyma/mrevista.pubmed_fu ll?inctri=05ZI010&rev= 27&vol=30&num=8&pag=496. (Consultado en 16-07-2007) 12. Toledano M. Informe sobre posibles PAOR V o l 1 - n ° 1 22 efectos adversos de la amalgama de plata para uso en odontología. Disponible en: http://www.consejodentistas.org/informació n_ama.php. (Consultado en: 16-07-2007) 13. Uribe Echevarría, Jorge. Operatoria Dental: Ciencia y Práctica. Madrid. Ediciones Avance Médico Dentales. S.L. 1990. EFECTO DE UN DENTÍFRICO EXPERIMENTAL CONTENIENDO MICROPARTÍCULAS DE BIOSILICATO® EN SUPERFICIE DE ESMALTE EROSIONADO IN VITRO: ESTUDIO COMPARATIVO. THE EFFECT OF AN EXPERIMENTAL DENTIFRICE CONTAINING BIOSILICATE® MICRON-PARTICLES ON ERODED ENAMEL SURFACE IN VITRO: A COMPARATIVE STUDY. PINTADO PALOMINO, K*; TIRAPELLI,C** ;PANZERI,H**; GAVA,IL***; DUARTE,R***. *DDS, Specialist in Restorative Dentistry, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Brazil. **DDS, PhD, Professor, Department of Dental Materials and Prosthesis, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Brazil ***Undergraduate students, Faculty of Dentistry of Ribeirão Preto, University of São Paulo, Brazil Resumen Objetivos: Este estudio evaluó in vitro el efecto de un dentífrico experimental (DE) con micropartículas de una vitrocerámica bioactiva - Biosilicato® (Mp-Bios) en la fórmula, para tratar la superficie erosionada del esmalte. Material y métodos: sesenta muestras de esmalte dental bovino (EDB) (4x4x3mm) fueron separadas en grupos experimentales (n = 10 por grupo): G1-control (agua destilada), G2-DE con Mp-BIOS 7.5%; G3-DE sin Mp-BIOS; G4- DE con monofluorfosfato - 1500ppm; G5- DE con NaF- 500ppm, y G6- DE con 7,5% de micropartículas de Bioglass 45S5 y sometidas a espectroscopia (FTIR), microscopía electrónica de barredura (MEB) y análisis de microdureza superficial (MS) , antes y después de 7 días de desafíos erosivos (inmersión en ácido láctico, pH = 4,3, 1 vez al día, durante 1 hora). Después de cada desafío erosivo, las muestras fueron expuestas a suspensiones de los dentífricos (15 min), seguido por inmersión en saliva artificial entre los desafíos erosivos. Otras sesenta muestras de EDB fueron sometidas a pruebas de rugosidad antes y después de una prueba de cepillado con los dentífricos evaluados. Las variaciones porcentuales de MS y rugosidad se analizaron con las pruebas de ANOVA-Tukey (á = 0,05). Resultados: Las menores variaciones de MS ocurrieron para G4, G2, G6, G3, G5 y G1, respectivamente. G2, G6 (p <0,5) y G4 (p <0,01) fueron más eficientes que G1 y G5 en el EDB reendurecido. Variación porcentual de rugosidad se observó sólo en G4, donde la superficie de las muestras se hicieron más lisas. La MEB mostró una superficie EDB alterado en G1, G3 y G5, y FTIR demostró que hidroxicarbonatoapatita se había formado en la superficie del EDB cuando el DE contenía partículas bioactivas (G2 y G6). Conclusiones: los resultados sugieren que la formulación de dentífrico con micropartículas de Biosilicato® podría ser una opción para tratar el esmalte erosionado. PALABRAS CLAVES: esmalte, erosión, pasta dental, biomateriales, dentífrico. PAOR V o l 1 - n ° 1 23 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Introduction Nowadays, the integrity of the enamel, dentin and cement surfaces have been challenged by further aggressive situations such as, acidogenic diets, gastroesophageal reflux disease(2), eating disorders(8) and increased use of tooth-whitening products(18). Because the critical pH of dental enamel is approximately 5.5, any solution with a lower pH value may cause erosion, particularly if the attack is of long duration, and repeated over time. Saliva and salivary pellicle counteract the acid attacks but if the challenge is severe, a total destruction of tooth tissue follows. Because enamel acid erosion is a surface phenomenon, the protection and treatment of tooth surfaces with acid-resistant and/or remineralizers agents appears to be an interesting strategy. The effectiveness of fluoride as a therapy for erosion is still under debate(4,15). Therefore, the search for innovative agents, with a cost-benefit as good as or better than that reached by fluorides remains a promising aim. In the dental field of developing new technologies to guarantee oral health, dentifrices represent an ancient product that has been reinvented throughout the years with innovative formulations(20). Because dentifrices (together with toothbrushes) represent the most easy-to-use and accessible products for oral self-care, they have become vehicles for a wide variety of therapeutic or preventive (antimicrobial and remineralizing) agents, such as fluorides(15), triclosan(3), chlorhexidine(17), medicinal plants(1) , chlorine compounds(13), CPPACP(12) and bioglasses(5). A new bioactive material that is a >99.5% crystallized (P 2 O 5 –Na 2 O–CaO–SiO 2 glassceramic powder-Biosilicate®), which was developed by a multidisciplinary research group(25), is being proposed as a suitable remineralizing agent in an experimental fluoridefree dentifrice formulation. Given the successful history of the use of biomaterials in bone regeneration(7), biomaterials, such as bioactive glasses and glass-ceramics, have been proposed for enamel and dentin regeneration. The PAOR V o l 1 - n ° 1 24 similarity between bone, dentin, and enamel led to the hypothesis that bioactive glasses and glassceramics could be applicable to regenerate eroded dental surfaces via the in-situ deposition of hydroxy carbonate apatite (HCA). Additionally, the antimicrobial properties of bioactive materials could be an additional advantage in improving oral health(26, 27). The first experiments with Biosilicate® showed that this novel material increases osteogenesis in cell culture(10), and in vivo tests indicated its good performance in bone regeneration(16). An in vitro study showed the effects of the micron-sized (1-20 µm) particles of Biosilicate® in human dentin(21). Observations from this study indicated that an HCA-bonded layer was deposited on the dentin surface and in the dentinal tubules. As a consequence, a clinical study was carried out to investigate Biosilicate particles as a desensitizing agent(22). The results from the 6-month clinical study showed a very significant decrease in dentin hypersensitivity pain in patients treated with Biosilicate® particles mixed with distilled water. Also, an in vitro comparative study showed that micronsized particles from Biosilicate were efficient in occluding dentinal tubules in dentin discs submitted to carbamide peroxide at 16%(14). Following these positive results with Biosilicate® particles, the present investigation was designed to evaluate an experimental fluoride-free dentifrice containing Biosilicate® micron-sized particles. Importantly, the crystalline character of Biosilicate® offers an advantage over all other types of bioglasses because crystallization significantly changes the fracture characteristics of glass, yielding less sharp and less abrasive particles(23), which could then be safely brushed against teeth and gingiva. Paraguay Oral Research Materials and Methods Preparation of the bovine enamel specimens One hundred and twenty (120) freshly extracted intact bovine incisors (with no cracks or erosion) stored in physiological saline solution at room temperature had the crowns separated from the roots using dental hand pieces. The facial sides of the crown were gently cut out with a diamond saw under water cooling to provide quadrangular BDE blocks that were successively ground (Polishing machine, Struers, Denmark) on wet silicon carbide paper with grain sizes ranging from 300 to 2000. The thickness and size of the flat BDE specimens (4x4x3 mm, n=120) were checked with a micrometer (Mitutoyo, Tokyo, Japan). All the specimens were sonicated and stored in 1.5 ml safe-lock tubes (Eppendorf Brazil, São Paulo, Brazil) with artificial saliva for one week until the start of the experiment. Study design The BDE specimens randomly received an identification number ranging from 1 to 120. The specimens 1 to 60 (Group A, n=60) were used to test the effect of the products on enamel surface, and specimens 61 to 120 (Group B, n=60) were used to test the abrasiveness of the toothpastes on enamel surface. The specimens were randomly allocated into six groups (A=G1, G2, G3, G4, G5, G6 and B= G1, G2, G3, G4, G5, G6; n=10 per group). To provide a comparative evaluation, the experimental dentifrice was compared to controls, to other commercial brand fluoride dentifrices, and to other experimental dentifrices with similar therapeutic agents. The products used in the comparative evaluation are described in Table 1 Table 1. Products tested in the study: experimental groups, therapeutics agents and manufacturers. The variables measured were micro-hardness and roughness of the bovine enamel surface before and after applying the dentifrices in two different conditions. These conditions were 1) cycles of erosive challenges (CEC) on enamel surface, which involved cycling the specimens in artificial saliva, acid conditions, the dentifrice slurry and artificial saliva again and 2) a simulation of the tooth brushing process to evaluate the abrasiveness of the dentifrices. Scanning electron microscopy (SEM) and Fourier transform infra-red spectroscopy (FTIR) One specimen from each group (A: G1, G2, G3, G4, G5, G6) was randomly chosen and submitted to SEM and FTIR analyses before and after the cycle of erosive challenges on bovine enamel. Also, the micron-sized particles of Biosilicate® and bioglass type 45S5 were analyzed at a SEM to observe morphological aspects. Surface micro-hardness measurements Specimens in each group (Group A: G1, G2, G3, G4, G5, G6) had their surface micro- PAOR V o l 1 - n ° 1 25 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y The research hypothesis was that the micron-sized particles of the developed bioactive glass-ceramic could be an option as a therapeutic agent in a fluoride-free dentifrice formulation. To test this hypothesis, we evaluated comparatively two parameters: i) the effect of this experimental dentifrice on bovine enamel surface challenged by an acid solution and ii) the abrasive effect of the experimental dentifrice on bovine enamel. w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research hardness measured using a micro-hardness tester (HMV-2000, Shimadzu, Kyoto, Japan) with a load of 25 g for 5 s at three different points on the bovine enamel surface before and after the sevenday cycles of erosive challenges. Roughness measurements Specimens in each group (Group B: G1, G2, G3, G4, G5, G6) had their surface roughness (Ra) measured before and after the tooth brushing test with a profilometer (SJ-201-P, Mitutoyo, Kawasaki, Japan) with a cut-off of 0.08 mm. Dentifrices Dentifrice formulations were prepared to incorporate Biosilicate® (G2) or bioglass 45S5 (G6), both at 7.5% (wt %), with the following components: carboxymethylcellulose, methyl psodium hydroxybenzoate, sodium saccharin, menthol oil, propylene glycol, glycerol, sorbitol, flavor, hydrated silica, thickening silica, and sodium lauryl sulfate. The strict control group (G3) contained the same components except the bioactive materials. A very popular commercial dentifrice (1500 ppm of fluoride) was employed in G4, and a low fluoride (500 ppm) dentifrice was used in G5.Enamel surface events: cycles of erosive challenges Specimens (Group A: G1, G2, G3, G4, G5, G6) were submitted to seven cycles of erosive challenge (one per day, for 7 days) at room temperature. Initially, the specimens were stored in individual tubes with artificial saliva for 12 h. Thereafter, each specimen was transferred to an individual tube with acid solution (5mL, lactic-acid with pH 4.3) and kept for 1 hour. Next, the specimens were washed with distilled water for one minute and inserted in another individual tube with the remineralizing solution (4mL, dentifrice suspensions prepared with distilled water in a 1: 3 proportion (w/w)) for 15 minutes. Sequentially, the specimens were pulled out of the tubes, washed again with distilled water for 1 minute and inserted in the individual tubes with fresh artificial saliva (5mL) where they were kept for 12 h to complete one cycle. The artificial saliva, acid solution, and remineralizing solution were changed at each cycle. The effect of the dentifrices was determined by evaluating the PAOR V o l 1 - n ° 1 26 micro-hardness of the specimens before and after the cycles. Specimens (Group B: G1, G2, G3, G4, G5, G6) were brushed using an automatic brushing machine with identical and new toothbrushes, with a load of 200 g and 350 strokes per minute for 1 minute, using a dentifrice slurry with a 1:2 dentifrice to distilled water ratio. The abrasiveness of each dentifrice was evaluated by the enamel roughness variation determined by profilometry of the specimens before and after tooth brushing. Statistics The data for the SM and roughness were collected before and after the events on the BDE surface (cycles of erosive challenges and tooth brushing tests) for each specimen. The percent variations of SM and roughness for each specimen were analyzed with an analysis of variance followed by the Tukey's test using the GraphPad 5.00 software for Windows. Results Representative SEM images from the baseline BDE are shown in Figure 1; they show evidence of a flat and smooth surface. Figure 1. SEM image from a bovine enamel specimen before the DesRe process. Figure 2 shows particles of bioglass type 45S5 (1.0 to 4.5 µm) and particles of Biosilicate® (1.0 to 1.5 µm). The morphological difference between the particles obtained from the crystallized vitroceramic (B) and those from a partially crystallized one (A) is shown in Figure 2, where the edges present in Paraguay Oral Research Figure 2. (A) Bioglass type 45S5 particles and (B) Biosilicate® particles. Figure 3 shows representative SEM images from specimens of DBE submitted to the cycles of erosive challenges. SEM revealed morphological differences brought about by the various products applied. Using Figure 1 as a baseline SEM image, the SEM images in Figure 3 show that in both the control group (G1) and the strict control group (G3), the enamel surfaces were affected by the acid solution, and no regeneration occurred with the application of distilled water or a dentifrice without a therapeutic agent. The SEM images of the specimens treated with the experimental dentifrice (G2), commercial brand dentifrice (G4), and experimental dentifrice containing bioglass type 45S5 (G6) showed no visual changes on the BDE surface, suggesting that these products played a role in the remineralization / regeneration of the enamel during the cycles of erosive challenges. Surprisingly, the specimens treated with the commercial brand fluoride dentifrice (G5) looked similar to the control specimens. Figure 3. SEM images of the surface of the specimens after the Des-Re process. In the upper left corner, letter and number identify the group to which the image belongs. Figure 4 shows representative FTIR results from the DBE surfaces. There were two different patterns of peaks; the first showed the groups G1, G3, G4, and G5 with no surface changes of the peaks that remained at the same position; and the second showed the groups G2 (Biosilicate) and G6 (bioglass) exhibiting significant changes. A small shift between 1062 cm-1 and 1050 cm-1 (G2 and G6) was observed, and the peak at 1100 cm-1 almost disappeared. This change was very important as it indicated the formation of HCA on the enamel surface triggered by the bioactive particles. The peaks observed for BDEs treated with dentifrices containing the bioactive material were coincident with peaks observed with Biosilicate® or bioglass type 45S5 after 24 hours in SBF (“a” spectrum); this is strongly suggested by the peak at 564 cm-1. After the cycles of erosive challenge, the “b” spectrum was the representative image for the bovine enamel treated with the experimental dentifrices containing the bioactive glass-ceramics (G2 and G6). The peaks G2 and G6 PAOR V o l 1 - n ° 1 27 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y the bioglass type 45S5 are not seen in the Biosilicate® particles. w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research were quite similar; therefore, only one (b) line was plotted to represent them. The main spectral peaks for the molecular vibrations of Biosilicate® and 45S5 were observed at 460, 536, 930 nm and at 1124, 602, 574 nm for bovine enamel. From these spectra, it was suggested that Biosilicate® formed a thin layer of HCA on the bovine enamel surface. The double peaks at 602 and 574 nm were the most important P-O crystal vibrational bend modes associated with HCA and they could be clearly observed on the BDE from G1, G3, G4, and G5 (“c” and “d” spectrum) in enamel surfaces treated or not treated with fluoride dentifrices (G1 and G3 versus G4 and G5). G3, and G5, which was consistent with greater decreases in SM. Figure 5. Variation in the specimens' micro-hardness exposed to Des-Re process. Figure 4. Representative FTIR analyses of the BDE surfaces before the Des-Re process. Figure 5 shows the variation of the surface micro-hardness (SM) of the specimens exposed to the cycles of erosive challenges. The smallest changes in SM were observed in increasing order for G4, G2, G6, G3, G5, and G1, indicating that the commercial brand fluoride-dentifrice (G4) was the most efficient in maintaining the SM of the BDE exposed to acid conditions, followed by the dentifrices in which a glass (G6) or glassceramic biomaterial (G2) was used as therapeutic agent. A statistically significant difference in SM was found between the control group (G1) and G2, and between G4 and G6. The product used in G2 was statistically significantly more efficient than its strict control (G3) or G5. As the specimens in G5 demonstrated the highest SM variation (with variation defined as decrease in SM), statistically significant differences were observed between G5 and G2, between G5 and G6, and between G5 and G4. The SEM images showed more disturbed enamel surfaces for G1, PAOR V o l 1 - n ° 1 28 For surface roughness variation (Figure 6), a statistically significant difference was found only when G4 was compared with G5. Actually, for G4 specimens, the surface became smoother after the toothbrush test. Figure 6. Variation in the specimens' roughness after the tooth brushing test. Discussion Currently, there is no standard protocol for erosion experiments in general, and in particular, for testing agents to prevent or to treat erosion of the enamel and dentin4. The experimental design of this study was therefore elaborated to test the effect of therapeutic agents on enamel surface submited to cycles of erosive challenges. From the literature there are evidences that fluoride agents are a good option to lead with eroded enamel, although no consensus regarding the best approach had been established yet. Moretto et al., 2010(9) evaluated in vitro the effect of dentifrices with different fluoride concentrations as well as of a low-fluoridated dentifrice supplemented with trimetaphosphate (TMP) on enamel erosion. The alterations of the enamel were quantified using the Knoop hardness test. The results suggested that the 500 microg F/g plus 3% TMP and 5,000 microg F/g dentifrices had a greater protective effect when compared with the 1,100 microg F/g dentifrice. Considering the side-effect of the fluoride products, non-fluoride therapeutic agents, are also investigated to treat dental eroded surfaces. A study evaluated the effect of CCP-ACP on bovine enamel eroded by cola drink. The results showed the enamel became hardener after four applications of CCP-ACP paste19. In this study, the SM and SEM was the main outcome of interest for testing the bioglass (type 45S5) and its crystalline counterpart as proposed agents to treat eroded enamel surface. There was no statistically significant difference between the SMs at baseline, indicating an efficient random distribution of the specimens. The bovine enamel in the control group (G1) showed the highest variation in SM as expected because distilled water had no effect in regenerating / rehardening the enamel surface exposed to acid conditions. Experimental dentifrices containing the bioactive materials of glass-ceramic (G2) and glass (G6) and the commercial brand fluoride-dentifrice (G4) were able to guarantee significantly lower SM variation than distilled water. The strict control dentifrice (G3) did not show the same effect that was observed for G2 and G6, indicating that the proposed therapeutic agents of Biosilicate® and bioglass type 45S5 were responsible for the lower variation in SM; or for re-hardening the enamel. There were no statistically significant differences between the experimental dentifrices (G2 and G6) compared to the commercial brand fluoride dentifrice containing 1,500 ppm of monofluorphosphate of sodium and calcium carbonate as remineralizing agents (G4), suggesting that the experimental and fluoride dentifrice had the same performance. However, when these experimental dentifrices (G2 and G6) were compared to the commercial brand fluoride dentifrice containing only 500 ppm of the fluoride compound (G5), a statistically significant difference was found, indicating that the fluoridefree experimental dentifrices (G2 and G6) were much more efficient than the low fluoride dentifrice (G5). Indeed, the literature confirms the benefits of using fluoride toothpaste in preventing caries in children and adolescents when compared to placebo, but the effects were only significant for fluoride concentrations of 1000 ppm and above(24). The commercial brand fluoride dentifrice (G4) showed the best results for SM variation. The dentifrice used in the group G4 was one of the most commonly used in Brazil, and it has two active remineralizing agents of MFP and reactive calcium carbonate. Also, there was no statistically significant difference between the G2 and G6 groups indicating that Biosilicate® and bioglass type 45S5 had the same effect on SM. The representative SEM images showed regular BDE surfaces for groups G2, G4, and G6, and it showed visual surface changes for G1, G3, and G5. The morphological variation in the enamel surfaces matched the variations in SM, and the higher SM variations occurred in the specimens from G1, G3, and G5, suggesting that when distilled water (G1), an experimental dentifrice without a therapeutic agent (G3), and a dentifrice with only 500 ppm of NaF (G5) were used, the enamel surface was disturbed. For the roughness variation, a significant difference in variation was found only when we compared the commercial brand fluoride dentifrice (G4) with the commercial brand low fluoride dentifrice (G5). The former made the surface of the bovine enamel smoother than before, whereas the latter PAOR V o l 1 - n ° 1 29 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research showed the greatest increase in roughness. The percent composition of the ingredients in the formulations of the dentifrices G4 and G5 were not available from the manufacturers. It is possible that the dentifrice with the lowest amount of fluoride also has a higher level of abrasives, and the commercial brand dentifrice with the two remineralizing agents (MFP and calcium carbonate) had a low amount of abrasives. Hara et al. 2008, (6), described the interplay between fluoride and abrasives on mineral surfaces, showing that fluorides reduced the surface loss in enamel at all abrasive levels. Muray and Shaw 1980 (11) suggested that the lower fluoride content the higher the abrasives content should be to guarantee adequate oral health status. Given the results of all the experiments and considering the limitations of this in vitro study, our research hypothesis was confirmed, and therefore, the micron-sized particles of Biosilicate® are an interesting option (in fluoride-free dentifrice formulations) as a therapeutic agent for treating eroded enamel. Additional questions to be answered in subsequent future investigations are as follows: i) Given that the bioactive vitro-ceramic triggered the HCA layer formation on the enamel, what is the thickness of this layer and how strong is its resistance to acid challenges?; ii) How does the acidity influence the reactions occurring on the bioactive particle surfaces?; iii) What would be the interplay between the microorganisms in the mouth, particularly streptococcus mutans, and the bioactive glasses?; iv) What is the optimal dose of the bioactive material into a dentifrice formulation?; and v) What would be the interplay between fluoride and bioactive vitro-ceramics in dentifrice formulations? Acknowledgments The authors are grateful to FAPESP, the State of São Paulo Research Foundation (contract number 09/00514-9 and 07/08179-9), and to Capes and CNPq for the financial support for this work. Conclusions The results from this in vitro study suggest that Biosilicate® micron-particles could be used as a remineralizing agent in a fluoride-free dentifrice formulation. 6. Hara AT, González-Cabezas C, Creeth J, Parmar M, Eckert GJ, Zero D. Interplay between fluoride and abrasivity of dentifrices on dental erosion-abrasion. J Dent. 2009 Oct; 37(10):781-5. 7. Hench LL. The story of Bioglass. J Mater Sci Mater Med. 2006 Nov;17(11):967-78. PAOR V o l 1 - n ° 1 30 References 1. Alviano WS, Alviano DS, Diniz CG, Antoniolli AR, Alviano CS, Farias LM, Carvalho MA, Souza MMG, Bolognese AM. In vitro antioxidant potential of medicinal plant extracts and their activities against oral bacteria based on Brazilian folk medicine. Arch Oral Biol. 2008 Jun;53(6):545-52. 2. Di Fede O, Di Liberto C, Di Nicola F, Giannone N, Occhipinti G, Lo Muzio L et al. Oral manifestations in gastroesophageal reflux disease. Recenti Prog Med. 2005 Sep;96(9):445-51. 3. Fine DH, Furgang D, Markowitz K, Sreenivasan PK, Klimpel K, De Vizio W. The antimicrobial effect of a triclosan/copolymer dentifrice on oral microorganisms in vivo. J Am Dent Assoc. 2006 Oct;137(10):1406-13. 4. Ganss C, Schlueter N, Hardt M, Schattenberg P, Klimek J. Effect of fluoride compounds on enamel erosion in vitro: a comparison of amine, sodium and stannous fluoride. Caries Res. 2008;42(1):2-7. 5. Gillam GD, Tang JY, Mordan NJ, Newman HN. The effects of a novel Bioglass dentifrice on dentine sensitivity: a scanning electron microscopy investigation. J Oral Rehabil. 2002 Apr;29(4):305-13. 8. Lo Russo L, Campisi G, Di Fede O, Di Liberto C, Panzarella V, Lo Muzio L. Oral manifestations of eating disorders: a c r i t i c a l r e v i e w. S A D J . 2 0 0 7 Mar;62(2):066-71. 9. Moretto MJ, Magalhães AC, Sassaki KT, Delbem AC, Martinhon CC. Effect of different fluoride concentrations of experimental dentifrices on enamel erosion and abrasion. Caries Res. 2010;44(2):135-40. 10. Moura J, Teixeira LN, Ravagnani C, Peitl O, Zanotto ED, Beloti MM et al. In vitro osteogenesis on a highly bioactive glassceramic (Biosilicate®). J Biomed Mater Res A. 2007 Sep 1;82(3):545-57. 11. Murray JJ, Shaw L. A 3-year clinical trial into the effect of fluoride content and toothpaste abrasivity on the caries inhibitory properties of a dentifrice. Community Dent Oral Epidemiol. 1980 Feb; 8(1):46-51. 12. Oshiro M, Yamaguchi K, Takamizawa T, Inage H, Watanabe T, Irokawa A, Ando S, Miyazaki M. Effect of CPP-ACP paste on tooth mineralization: an FE-SEM study. J Oral Sci. 2007 Jun;49(2):115-20. 13. Panzeri H, Lara EHG, Paranhos HFO, da Silva CHL, de Souza RF, Gugelmim MCMS, Tirapelli C, Cruz PC, Andrade IM. In vitro and clinical evaluation of specific dentifrices for complete denture h y g i e n e . G e r o d o n t o l o g y. 2 0 0 9 Mar;26(1):26-33. 14. Pinheiro HB; Lopes B; Klautau EB; Cardoso J; Silva BR; Cardoso PEC. Influence of bioactive materials used on the dentin surface whitened with carbamide peroxide 16%. Mat Res. 2010 Jun; 13(2):273-8. 15. Rios D, Magalhães AC, Polo RO, Wiegand A, Attin T, Buzalaf MA. The efficacy of a highly concentrated fluoride dentifrice on bovine enamel subjected to erosion and abrasion. J Am Dent Assoc. 2008 Dec;139(12):1652-6. 16. Roriz VM, Rosa AL, Peitl O, Zanotto ED, Panzeri H, Oliveira PT. Efficacy of a bioactive glass-ceramic (Biosilicate®) in the maintenance of alveolar ridges and in osseointegration of titanium implants. Clin Oral Implants Res. 2010 Feb;21(2):148-55. 17. Slot DE, Lindeboom R, Rosema NAM, Timmerman MF, van der Weijden GA. The effect of 0.12% chlorhexidine dentifrice gel on plaque accumulation: a 3-day non-brushing model. Int J Dent Hyg. 2007 Feb;5(1):45-52. 18. Sykes LM. Dentine hypersensitivity: a review of its aetiology, pathogenesis and management. Oral Dis. 2008 Sep;14(6):479-84. 19. Tantbirojn D, Huang A, Ericson MD, Poolthong, S. Change in surface hardness of enamel by a cola drink and a CPP–ACP paste. J Dent. 2008 Jan;36(1):74-9. 20. Tirapelli C, Panzeri FC, Ribas JP, Panzeri H. Dentifrices: current view. Revista ABO 2007, 81:364-367. 21. Tirapelli C, Panzeri H, Lara EHG, Soares RG, Peitl O, Zanotto ED.The effect of a novel crystallised bioactive glassceramic powder on dentine hypersensitivity: a long term clinical study. J Oral Rehabil, 2010. doi: 10.1111/j.1365-2842.2010.02157.x 22. Tirapelli C, Panzeri H, Soares RG, Peitl O, Zanotto ED. A novel bioactive glassceramic for treating dentin hypersensitivity. In press: Braz Oral Res, 2010. 23. Varner JR, Quinn GC, Wightman M. Fractography of Glasses and Ceramics V Wiley & Sons; 484 pages, August 2007. 24.Walsh T, Worthington HV, Glenny AM, Appelbe P, Marinho VC, Shi X. Fluoride toothpastes of different concentrations for preventing dental caries in children and adolescents. PAOR V o l 1 - n ° 1 31 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Paraguay Oral Research Cochrane Database Syst Rev. 2010 Jan 20; (1): CD007868. Review. w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y 25. Zanotto ED, Ravagnani C, Peitl O, Panzeri H, Lara EH. Process and compositions for preparing particulate, bioactive or resorbable biosilicates for use in the treatment of oral ailments, Patent WO2004/074199, Fundação Universidade Federal de São Carlos; Universidade de São Paulo, 20 Feb. 2004. 26. Zehnder M, Luder HU, Schatzle M, Kerosuo E, Waltimo T (b). A comparative study on the disinfection potentials of bioactive glass S53P4 and calcium hydroxide in contra-lateral human premolars ex vivo. Int Endod J. 2006 Dec;39(12):952-8. 27. Zehnder M, Waltimo T, Sener B, Söderling E (a). Dentin enhances the effectiveness of bioactive glass S53P4 against a strain of Enterococcus faecalis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2006 Apr;101(4):530-5. PAOR V o l 1 - n ° 1 32 Paraguay Oral Research Relation between the primary stability and the format and surface treatment of Dental Implants:literature review Ferraz Oliscovicz, N*; Shimano, AC**, Elizaur Benitez Catirse, AC***, Carrico Nogueira, FH****, Cândido dos Reis,A***** *Pos-graduation student, Department of Dental Materials and Prosthodontics, University of São Paulo Faculty of Denstistry of Ribeirão Preto, Brazil **Associate Professor, Department of Biomechanics, Medicine and Reabilitation of Locomotive Device, University of São Paulo, Faculty of Medicine of Ribeirão Preto, Brazil ***Associate Professor, Department of Dental Materials and Prosthodontics, University of São Paulo Faculty of Denstistry of Ribeirão Preto, Brazil ****Pos-graduation student, Department of Dental Materials and Prosthodontics, University of São Paulo Faculty of Denstistry of Ribeirão Preto, Brazil *****Prof. Dr, Department of Dental Materials and Prosthodontics, University of São Paulo Faculty of Denstistry of Ribeirão Preto, Brazil ABSTRACT The format of the implant, surface treatment and characteristics of the bone is essential to get the primary stability. The aim of this article is review and analyze critically the current available literature in the field of primary stability of implants and discuss the methods of analysis and its relation with the format and surface treatment that influence in the primary stability. Important and relevant articles were selected from Medline that discuss about shape and surface treatment of the implant screw, and evaluated primary stability through insertion of torque and Resonance Frequency Analysis (RFA). Reports on pullout test were found in relation to orthopedic implants. The reviewer intends to include the main information in the articles selected and also a critical evaluation. The discussion data is organized as to emphasize factors significantly related to primary stability. Implantodontics lacks confident methods and scientific based results which determine the existence and efficiency of primary stability relating it with implant shape and surface treatment. It is believed that performance assays associated to Resonance Frequency Analysis, add knowledge related to implant primary stability, considering that it may quantify the maximum force necessary to destabilize the implant on the bone. Keywords: stability primary, dental implants, design of implants, treatment of superficies Introduction Primary stability, the resistance to micro movements during surgical time (4) is one of the main factors, which determine osseointegration(3,4,6,7,9,17). Osseointegration is at its best when biological and mechanical principles are respected together. Thus, bone quality and quantity, correct surgical techniques and implant geometry directly influence primary stability (25). PAOR V o l 1 - n ° 1 33 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Relación entre el estabilidad primaria y formato y tratamiento de superficies de los implantes dentales: revisión de la literatura w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Implant design, classified according to constituted material and morphology (46) is the subject of intensive research aiming to find the best type (shape, type of screw, length, diameter) and prevent failure in bone anchoring (29) especially in the technique of immediate load. The most important condition, determinant of clinical success, is when the implant with immediate or precocious load acquires initial stability (28), a requisite to initiate the prosthetic treatment. Therefore, load application must be previously evaluated. Primary stability may be analyzed by insertion torque and resonance frequency, a non invasive method where bone formation around the implant is measured by the Osstell TM Mentor instrument (Intgrations Diagnostics AB, Savedalen, Sweden)(23). A complementary method to measure primary stability is the pullout test. This is also multifactorial and related to the implant design, bone density, and the surgical preparation for implant installation (16). Modifications in screw threading may substantially modify the pullout strength (15). Few reports were found in the literature describing pullout resistance to dental implants, which could contribute to studies of primary stability. This review aims to cover articles reporting primary stability analysis of dental implants, through performance assays and resonance frequency analysis (RFA or ISQ) as a function of shape and surface treatment and to emphasize the great scarcity in the literature on this specific theme. Methods and Aims Important and relevant articles were selected from Medline. The first selection was of information on shape and surface treatment of the implants. The next group selected were articles on primary stability evaluated through insertion torque, resonance frequency and pullout tests. The reviewer intends to include the main information in the articles selected and also a critical evaluation. The discussion data is organized as to emphasize factors significantly PAOR V o l 1 - n ° 1 34 related to primary stability. Results Increased indications for the use of dental implants a, resulted in diverse implant brands, some made with poorly known material, design and surface characteristics. This diversity as well as the right surgical procedure for its installation and the bone quality contributes to difficulties of use. For a confident prevision of osseointegration a method is needed, which results in primary stability. The technique chosen must be related to osseointegration determining factors, should be clinically feasible, simple, rapid, non invasive, low cost, and not risk implant success. Thus, a numeric value could be assessed at the time of the final implant installation through torque insertion (4). These authors compared torque insertion of 100 dental implants after waiting for osseointegration and found 5 unsuccessful ones, three of them with an insertion torque greater than 40 Nc (good primary stability). Of the successful implants, 14 had a torque between 0 and 10 Nc (unsatisfactory initial stability). The results implied that insertion torque should not be the only method to gauge initial stability and this should not be the only criterion to determine osseointegration. Primary stability may be also determined by RFA or ISQ using the Osstell TM clinical instrument (11,23,24). The validity of the method was evaluated (3) utilizing implants, installed with an insertion torque of 45 N/cm in the mandibles of human cadavers. The results indicated confidence in the RFA to determine implant primary stability but there was no concordance in relation to insertion torque. Boronat López, et al. (2) evaluated the primary stability of 133 implants through ISQ and insertion torque at the day of surgical installation. The implant stability ISQ and insertion torque means were 62.1 and 35.7 Ncm, respectively, and were proportional. Kahraman, et al. (17) also found a correlation between insertion torque and RFA in selfthreading implant systems, where the mean for insertion torque and RFA in primary stability were respectively 33 ±11 Ncm and 66 ±12. In medical orthopedics, implants are tested by resistance to pullout strength. This could be altered by the design of screw threads (47). Zamarioli, et al. 47(2008) evaluated different screws to in test structures of polyurethane, density 0.16 and 0.32 g/cm3, having different diameter pilot orifices and thread design. They detected the influence of these factors in the insertion torque and force of retrieval. The functional objective of design is to dissipate and distribute biomechanics loads of the implant-supported prosthetic piece (25). Selection of the appropriate implant design is imperative to diminish the magnitude, quantity and type of loads imposed on the implant/bone interface (1,13,19). The functional area, identified thread quantities and depths (37), is responsible to dissipate compression stress and tension, but not shearing stress at the bone interface and to give initial stability (19). Implant design has more influence on the surface area than on width. A cylindrical smooth implant has 30% less surface area than a threaded one of the same size. Smooth cylindrical implants are loaded with pure shearing stress at the bone implant interface. Threaded implants modify the load applied to the bone interface through the geometry of the screw threading (27). New implant biomaterials are being explored and/or developed to alter cellular performance at the bone-implant interface (36). A rough and porous surface increases the effective surface about 12 times in relation to a smooth one, generating an osteo-inductive effect and increasing the anchoring of the implant on the bone as was observed by Schroeder, et al. (34)1981, in histological studies. Some studies show that resonance frequency increases with the micropore size and oxide thickness (38). Sul, et al. 38(2002) investigated, by resonance frequency, the stability of implants topographically modified and/or with chemically modified surfaces, six weeks after installation in rabbit bone. Chemically modified surfaces showed a higher mean in the primary stability quotient than the implants topographically modified. Carvalho, et al. (5) 2009, revised 36 literature reports of the last 27 years and concluded that rough surfaces have higher and better bone-implant contact, as well as better biomechanical characteristics. In the same line of research, Tabassum et al. (39) reported biomechanical studies of the effect of surface roughness on primary stability, through insertion torque and retrieval in 160 screw type implants inserted in polyurethane blocks with a density of 0.49 g/cm3, similar to the trabecular bone and a 0.0 to 2.5 mm lamina to simulate cortical bone. They found increased torque values when the implants with acid treated surfaces showed higher insertion torque when compared to the machine produced ones. Clinical experiments with porous miniimplants were successful in 95% of cases (4 years) making possible the use of smaller implants in bone deficient sites, since and increased surface area was observed in comparison to machine-made implants (10). Thus, textured surfaces are indicated for poor quality bone, grafted areas, immediate implant and load and allow previsions of osseointegration. However, for wide clinical use the surfaces still lack long period longitudinal studies (41). Theoretically, a rough surface has a higher capacity for a resistant interaction at the implant insertion than a smooth one. This prevents micromovements, so pernicious to the establishment of osseointegrated interfaces. Rapid bone deposition also takes place. However, body surfaces in implants should be smooth, where soft tissue/implant interfaces will form, or where it is expected to occur reabsorption and later migration of the soft tissue. Discussion A considerable portion of studies reported in the literature on primary stability are of analysis methods by insertion torque and PAOR V o l 1 - n ° 1 35 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Resonance Frequency Analysis. These methods sometimes present correlations and sometimes they do not (2,3,17) making it difficult to decide which is the best one for this analysis, and producing a gap in this area of knowledge. Another reference test, which could be used is pullout test, utilized in orthopedic implant research (47,32). Association of this type of analysis to the other ones would spread the variability of methods and increase confidence in the indication or not of certain types of implants in the diverse conditions encountered in clinical practice, like low bone quantity and quality. Scarce knowledge is available on the correlation of these methods to implant design and surface treatment, since it is necessary to understand the influence of this factors and the importance of the analysis. This discussion is based on relevant factors in implant primary stability: design and treatment of surfaces and the showing of success in relation to performance tests and resonance frequency analysis. Implant Design With the significant evolution of defined clinical parameters, many types of implants were developed. To be adequate the implant should have some properties such as, immediate stability, have maximal superficial anchorage, be easily inserted, cause the least bone trauma during insertion and resist to the insertion and retrieval torques (46). Implant design is of great importance in primary stability, but it is also, extremely necessary to observe quantity and quality of bone and the site of installation. Several authors recommend that implants with immediate load should be associated to dense cortical bone and have bicortical anchorage in both the apical bone and the bone crest (8,14,33,40). However, in the apical aspect, this anchorage is not feasible in several cases, mainly in posterior regions (44), which need longer implants. To increase the implant length would not be especially advantageous but it would be necessary to develop different implant macro and micrometric shapes. Another aspect to be considered in PAOR V o l 1 - n ° 1 36 elaborating varied generic implants should be tension parameters to maintain the bone of the crest border and the implant material. Thus, a careful treatment plan, including an appropriate selection of implant design, is imperative to decrease the magnitude, quantity and type of loads imposed on the interface implant/bone (1,13,19,26). To compensate problems due to poor bone quantity and quality, implant shape and thread characteristics should be evaluated when one is chosen. According to Chong et al. (9) selftreading implants have better initial stability than the ones without threads. Cylindrical smooth implants are easier for surgical insertion, but the bone/implant interface is submitted to a much greater shearing stress compared to a conical smooth implant, which allows a compression load component applied in the interface. In contrast, the implant threaded in circular transversal sections is easily inserted surgically and permits an optimized functional surface, facilitates an initial rigid fixation, which limits micromoviments during the healing process. The loading of implants with radicular shapes lengthwise to its axis is limited by the mandible and maxilla anatomy, which by preventing installation in satisfactory positions result in absence of bone compressive loads. Implant angulations aiming to attain a favorable position, may imply increased tension on the bone crest and result in higher peri-implant bone loss (27). Considering these facts, the functional surface area of the implant should have its design improved to support the functional loads, since it is responsible to dissipate compression and tension loads to the bone/implant interface and thus allow initial stability after insertion. This is fundamental to the first implant threads, in the region close to the prosthetic component, since most tension is applied at the half closer to implant crest, a very important zone for the adequate distribution of tensions. In the posterior areas of maxilla and mandible arcades, the load magnitude increases, reduces bone volume and height and calls for a careful engineering to improve implant design to support functional loads in these anatomical limits (20,21,35). Thus, the implant shape may be the easiest method to significantly increase surface area and primary stability diminishing the influence of imposed loads. Considering all these factors, the extrinsic biomechanical characteristics which are attracting more interest in research are the geometrical configuration, and superficial topography of the implant. They are responsible for the tissue response to the installation of an alloplastic element, to a controlled aggression during the bone preparation and after implant loading, when functional and parafunctional loads will act on prosthetic components and these on the implants. This means that several specific dental implant design characteristics may be varied, independently or as a whole, to improve the functional surface area of load transference. Treatment of implant surface The advantages of a texturized surface are uncontested as confirmed Carvalho, et al, (5)2009; who observed higher bone/implant contacts with rough surfaces treated chemically or just with acid. These are also better when compared to machine made implants (31). However, in cortical bone thickness above 2.0 mm, surface roughness is not an influent factor (39). Acid treatment produced surface has uniform micro rugosities and micropores - the microretentions. In acid-treated surfaces the values of insertion torque permit its clinical application in cases where a higher initial stability is needed, like for immediate load (22). Texturizing by jetting particles produces uneven depressions on the machine-made surfaces- the macroretentions (41). However, this method is difficult to get a homogenous surface throughout the implant (45) Associating particle jetting and acid treatment produces micro and macro retentions, which promote a wider surface profile. The surfacet shows higher retrieval torque in relation to the acid treatment only and bone/implant contact of 60 to 70% However the technique does not prevent incorporation of oxide particles on the implant surface. The problem was minimized by jetting with HP particles, an osteoconductor, not prejudicial to bone conductivity to the surface (12). The use of radiation of low intensity laser to texturize surfaces is responsible for transforming the cell metabolic and functional activities (18) and has advantages like low contamination indexes due to lack of contact of the implant surface with chemical substances (41). In addition primary stability is higher in laser treated implants, according to Torres & Teixeira, (42)2008 due to greater bone formation. The reports show that different surface textures are indicated for regions of bad bone quality because they promote, due to topography improved bone contact and an interface of higher resistance. Conclusions Through this literature review we can conclude that implantodontics lacks confident methods and scientific based results which determine the existence and efficiency of primary stability relating it with implant shape and surface treatment. It is believed that performance assays associated to resonance frequency, add knowledge related to implant primary stability, considering that it may quantify the maximum force necessary to destabilize the implant on the bone. The search for new materials and methods to evaluate primary stability is a high priority, hopefully contributing to overcome the problems due to limited surgical techniques, poor bone quantity and quality available at the site of implant installation. References Astrand P, Engquist B, Dahlgren S, Engquist E, Feldmann H, Gröndahl K. Astra Tech and Branemark system implants: a prospective 5year PAOR V o l 1 - n ° 1 37 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research 1. comparative study- results after one year. Clin Impl Dent Relat Res. 1999 Jul;1(1):17-26. 2. Boronat López A, Peñarrocha Diago M, Martínez Cortissoz O, Mínguez Martínez I. Resonance frequency analysis after the placement of 133 dental implants. Med Oral Patol Oral Cir Bucal 2006 Mai;11(3),:E272-6. 9. Chong L, Khocht A, Suzuki JB, Gaughan J. Effect of implant design on initial stability of tapered implants. J Oral Implant. 2009 Jun;35(3):130-5. 3. Brouwers JEIG, Lobbezoo F, Visscher CM, Wismeijer D, Naeije M. Reliability and validity of the instrumental assessment of implant stability in dry human mandibles. J Oral Rehab. 2009 Apr;36(4):279–83. 10. Deporter DA, Todescan R, Watson PA, Pharaoh M, Levy D, Nardini K. Use of endopore dental implant to restore single teeth in the maxilla: protocol and esrly results. Int J Oral Maxillofac Implants 1998 Mar/Apr;13(2):263-72. 4. Carvalho MA, Queiroz CM, Molena CCL, Rezende CP, Rapoport, A. Estudo clínico da relação do torque de inserção dos implantes e sua osseointegração. Rev Bras Cir Cabeça Pescoço. 2008 Oct/Nov/Dec;37(4):202-5. 11. Friberg B, Sennerby L, Gröndahl K., Bergström C, Bäck T, Lekholm U. On cutting torque measurement during implant placement: a 3-year clinical prospective study. Clin Implant Dent Relat Res.1999 Oct;1(2):75–83. 5. Carvalho BM, Pellizzer EP, Moraes SLD, Falcón-Antenucci RM, Ferreira JS Jr. Surface treatments in dental implants. Rev Cir Traumatol Bucomaxilofac. 2009 Jan/Mar;9(1):123-30. 12. Gronowicz G & Maccarthy MB (Response of human osteoblasts to implant materials: integrin-mediated adhesion. J Orthop Res.1996; 14:878-87. 6. Çehreli MC, Kökat AM, Comert A, Akkocaoðlu M, Tekdemir I, Akça K. Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets. Clin Oral Impl Res. 2009a Oct;20(10):1163–9. 7. Cehreli MC, Karasoy D, Akca K, Eckert SE. Meta-analysis of methods used to assess implant stability. Int J Oral M a x i l l o f a c I m p l a n t s . 2009b;24(6):1015–32. 8. Chiapasco M, Gatti C, Rossi E, Haefliger W, Markwalder TH. Implant-retained PAOR V o l 1 - n ° 1 38 mandibular overdentures with immediate loading: a retrospective multicenter study on 226 consecutive cases. Clin Oral Impl Res. 1997 Feb; 8(1):48–57. 13. Hansson S. The implant neck: smooth or provided with retentions elements biomechanical approach. Clin Oral Impl Res 1999;10:394-405. 14. Hui E, Chow J, Li D, Liu J, Wat P, Law H. Immediate provisional for single-tooth implant replacement with Branemark system: preliminary report. Clin Implant Dent Relat Res. 2001; 3:79–86. 15. Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J. Increase of pullout strength of spinal pedicle screws with conica core: biomechanical tests and ? nite element analyses. J Orthop Res. 2005 Jul;23(4):788-94. Oral Patol Oral Cir Bucal. 2006 Mai/Jun;11(3):E281-5. 16. Inceoglu S, Ferrara L, McLain RF. Pedicle screw fixation strength: pullout versus insertional torque. Spine J. 2004 Sept/Oct;4(5):513-8. 23. Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Impl Res. 1996 Sept;7(3): 261-7. 17. Kahraman S, Bal BT, Asar NV, Turkyilmaz I, Tözüm TF. Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil. 2009 Oct;36(10):755-61 18. Khadra M, Lyngstadaas SP, Haanæs HR, Mustafa K. Effect of laser therapy on attachment, proliferation e differentiation of human osteoblast-like cells cultured on titanium implant material. Biomaterials. 2005; 26:3503-9. 19. Kline R, Hoar JE, Beck GH, Hazen R, Resnik RR, Crawford EA. Prospective multicenter clinical investigation of a bone quality-based dental implant system. Implant Dent 2002;11(3):224 –34. 20. Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol. 1991;17(2):126-31. 21. Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. J Oral Implantol. 1992;18(4): 343-53. 22. Martínez González JM, García Sabán F, Ferrándiz Bernal J, Gonzalo Lafuente JC, Cano Sánchez J, Barona Dorado C. Removal torque and physico-chemical characteristics of dental implants etched with hydrofluoric and nitric acid. An experimental study in Beagle dogs. Med 24. Meredith N, Book K, Friberg B, Jemt T, Sennerby L Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8:234-43. 25. Meredith, N. Assessment of implant stability as a prognostic determinant. Int J P r o s t h o d o n t i c s 1 9 9 8 Sept/Oct;11(5):491–501. 26. Misch CE, Poitras Y, Dietsh-Misch F. Endosteal implants in the edentulous posterior maxilla: rationale and clinical reports. Oral Health. 2000; 8:7-15. 27. M i s c h C E . I m p l a n t e s D e n t a i s Contemporâneos. São Paulo: Editora Santos; 2006. 28. Morton D, Jaffin R, Weber H-P. Immediate restoration and loading of dental implants: Clinical considerations and protocols Int J Oral Maxillofac Implants. 2004 (suppl);19(7):103–8. 29. O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Impl Dent Rel Res. 2000 Apr;2(2):85–92. 30. Raghavendra S, Wood MC, Taylor TD. Early wound healing around PAOR V o l 1 - n ° 1 39 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research Paraguay Oral Research implants: a review of the literature. Int J Oral Maxillofac Implants. 2005 Mai/Jun;20(3):425-31. w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y 31. Rodriguez-Rius D, Garcia-Saban FJ. Caracterización físico-química de la superficie de 9 implantes dentales con 3 distintos tratamientos de superficie. Med Oral Patol Oral Cir Bucal 2005 Jan/Feb;10(1):58-65. 32. Rosa RC, Silva P, Shimano AC, Volpon JB, Defino HLA, Schleicher P, Kandziora F. Análise biomecânica de variáveis relacionadas à resistência ao arrancamento dos parafusos do sistema de fixação vertebral. Rev Bras Ortop. 2008 Jul;43(7):293-9. 33. Schnitman PA, Wöhrle PS, Rubenstein JE, DaSilva JD, Wang NH. Ten-year results for Branemark implants immediately loaded with fixed prostheses at implant placement. Int J Oral Maxillofac Implants 1997 Jul/Aug;12(4):495–503. 34. Schroeder A, Van Der Zypen E, Stich H, Sutter F. The reactions of bone, connective tissue and epithelium to endosseal implants with spryed titanium surfaces. J Maxillofac Surg. 1981; 9:1525. 35. Sertgoz A & Guvener S. Finite element analysis of the effect of cantilever and implant length on strees distribution on implant supported prosthesis. J Prosthet Dent. 1996; 75:165-169. 36. Stanford C. Surface modifications of dental implants. Aust Dent J 2008;53(1 Suppl):S26–S33. 37. Strong JT, Misch CE, Bidez MW, Nalluri P. Functional surface area: Threadform PAOR V o l 1 - n ° 1 40 parameter optimization for implant body design. Compedium. 1998; 19:19-25. 38. Sul YT, Johansson CB, Jeong Y, Wennerberg A, Albrektson T. Resonance frequency-and removal torque analysis of implants with turned and anodized surface oxides. Clin Oral Impl Res 2002 Jun;13(3):252–9. 39. Tabassum A, Meijer GJ, Wolke JGC, Jansen JA. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Clin Oral Impl Res. 2010 Feb;21(2):213–20. 40. Tawse-Smith A, Payne AGT, Kumara R, Thomson WM. One-stage operative procedure using two different implant systems: a prospective study on implant overdentures in the edentulous mandible. Clin Impl Dent Relat Res 2001;3(4):185–93. 41. Todescan FF, Bechelli A, Romanelli H. Implantodontia Contemporânea – Cirurgia e Prótese . São Paulo: Artes Médicas; 2005. 42. Torres M. & Teixeira E. Influence of low power laser (GaAlAs – ë830nm) on bone formation related to primary stability in type IV bone. Rev Odonto Ciênc. 2008; 23:175-181. 43. Trisi P, Rao W. Bone classification: clinical-histomorphometric comparison. Clin Oral Impl Res. 1999 Feb;10(1):2–7. 44. Wang K, Li DH, Guo JF, Liu BL, Shi SQ. Effects of buccal bi-cortical anchorages on primary stability of dental implants: a numerical approach of natural frequency analysis. J Oral Rehab 2009 Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Wennerberg A, Albrektsson T, Johansson C, Andersson B. Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface t o p o g r a p h y. B i o m a t e r i a l s . 1 9 9 6 Jan;17(1):15–22. 46. Worthington P, Lang BR, Rubenstein JE. Osseointegração na odontologia (uma visão geral). São Paulo: Quintessence Editora Ltda, 2005. 47. Zamarioli A, Simões PA, Shimano AC, Defino HLA. Insertion torque and pullout strength of vertebral screws with cylindrical and conic core. Rev Bras Ortop. 2008 Oct; 43(10):452-59. PAOR V o l 1 - n ° 1 41 Paraguay Oral Research Restauraciones con resina compuesta en el sector posterior con la técnica directa en una cavidad clásica y en una extensa abarcando una cúspide w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Kegler EG*, Arce J**, Samaniego M***, Landivar J****, Fernandez R*****. * Máster en Dentística FOB USP, Especialista en Dentística FOB USP, Docente de la Cátedra de Operatoria Dental UNA, Docente del Curso de Especialización en Operatoria Dental IOA, Docente del Curso de Perfeccionamiento en Estética y Cosmética Dental del Círculo de Odontólogos de Itapúa ** Máster en Materiales Dentales FOB USP, Docente del Curso de Especialización en Operatoria Dental IOA, Docente del Curso de Perfeccionamiento en Estética y Cosmética Dental del Círculo de Odontólogos de Itapúa *** Especialista en Operatoria Dental FOB USP, Docente del Curso de Especialización en Operatoria Dental IOA, Docente de la Cátedra de Dentística Clínica UP, Docente de la Cátedra de Operatoria Dental UNCA, Docente del Curso de Perfeccionamiento en Estética y Cosmética Dental del Círculo de Odontólogos de Itapúa **** Especialista en Dentística FOB USP ***** Máster en Dentística UFPEL, RS, Docente de la Cátedra de Operatoria Dental UAP, Docente de la Cátedra de Clínica de Operatoria Dental UAA, Docente del Curso de Especialización en Operatoria Dental IOA RESUMEN: Los clínicos están en busca de nuevos materiales, técnicas y métodos alternativos para reconstruir dientes con mucha pérdida de estructura en forma directa tanto en dientes vitales como no vitales. Las mejoras en las propiedades físicas y mecánicas de las resinas compuestas actuales permiten extender las indicaciones de este material a restauraciones amplias como alternativa a restauraciones indirectas presentando como principal ventaja conservación de estructura dental sana y el costo. Existen estudios que soportan esta técnica, no obstante mayor evidencia científica es necesaria para comprobar la duración de este tipo de restauraciones, pero se hace evidente que estos materiales siguen evolucionando y tal vez estos sencillos procedimientos en dientes con gran pérdida de estructura sean de rutina en el futuro. El objetivo de este artículo es describir las maniobras clínicas de restauración con resina compuesta nanoparticulada, de dos piezas dentarias 3.6 y 3.7 que presentaban restauraciones deficientes, uno con extensa pérdida de estructura dental envolviendo una cúspide y el otro con menor pérdida de estructura. PALABRAS CLAVES: Restauraciones extensas, Resinas compuestas, Restauraciones directas. PAOR V o l 1 - n ° 1 42 Introducción Las resinas compuestas surgieron en el mercado como evolución de las resinas acrílicas restauradoras y su composición consta de una porción orgánica y otra inorgánica (Bowen 1956). Las mismas fueron patentadas por Bowen en 1962, dando comienzo a una nueva era en la odontología restauradora. (Nagem Filho 1999). En un principio eran utilizadas solo en dientes anteriores, y a partir del surgimiento de las resinas hibridas pasaron a ser utilizadas también en dientes posteriores. Estos materiales fueron evolucionando en sus propiedades físicas y químicas, apareciendo en el mercado resinas microhibridas (0,1 -10µm) y luego nanoparticuladas con partículas en nanoaglomerados (0,6 – 1,4 µm). La utilización en esta escala permitió la inserción de una mayor cantidad de partículas inorgánicas (82% en volumen) disminuyendo la contracción de polimerización y mejorando aún más las propiedades. (Fracci 2006). Según el Consejo de la ADA (1998) las restauraciones en dientes posteriores con resina compuesta deben estar limitadas a cavidades pequeñas y medianas, esta sugerencia fue hecha basada en la baja resistencia al desgaste y el comportamiento marginal de las primeras resinas compuestas. (Roulet 1997) No obstante una revisión de la literatura publicada en el 2001 no reportó diferencia significativa entre restauraciones directas e indirectas con resina compuesta después de 3 años. (Hickel 2001) Varios son los factores que llevan a los clínicos a realizar mayor número de restauraciones con este material dejando de lado la amalgama; entre las que pueden ser citadas: mejoras en las propiedades mecánicas y físicas de adhesivos y resinas (Van Meerbeek 2001; Hickel 2000); demanda de pacientes por restauraciones estéticas, posibilidad de conservar la estructura dental sana remanente. Además puede ser mencionado el factor económico, ya que varios pacientes no pueden acceder a tratamientos restauradores más costosos, como lo son las restauraciones indirectas. Es por eso que en el consultorio, los odontólogos muchas veces se ven obligados a extender la utilización de las resinas con técnica directa a restauraciones amplias. Este fenómeno se está dando tanto en países del tercer mundo como en países del primer mundo. (Liebenberg 2000; Deliperi 2005). Actualmente el dogma de la odontología restauradora está siendo reevaluado, los clínicos están en busca de nuevos materiales, técnicas y métodos alternativos para reconstruir dientes con mucha pérdida de estructura en forma directa tanto en dientes vitales como no vitales (Deliperi 2005). El objetivo de este artículo es describir las maniobras clínicas de restauración con resina compuesta nanoparticulada de dos piezas dentarias que presentaban restauraciones deficientes, uno con extensa pérdida de estructura dental envolviendo una cúspide y el otro con menor pérdida de estructura. Relato del Caso Clinico: Paciente de 30 años de edad, de sexo femenino con buena higiene bucal y bajo riesgo de caries, se presentó a la consulta odontológica con dos restauraciones deficientes de resina compuesta, en los dientes 3.6 y 3.7, por lo cual se decidió sustituirlas utilizando la técnica directa de restauración con resinas compuestas. Luego de realizar el aislamiento absoluto se procedió a la eliminación de las restauraciones antiguas con puntas diamantadas esféricas compatibles al tamaño de las cavidades. En el margen vestíbulo distal de la cavidad del 3.6 la terminación de la preparación fue realizada en forma de chanfer por los motivos anteriormente citados. El acabado del borde cavo superficial fue efectuado con una fresa diamantada dorada en forma de llama con el objetivo de eliminar todos los prismas de esmalte friables, este procedimiento nunca debe ser pasado por alto ya que es fundamental para promover las funciones de retención, resistencia y mantenimiento del sellado marginal de la restauración. Ambas preparaciones dentarias PAOR V o l 1 - n ° 1 43 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research recibieron base de ionómero de vidrio modificado con resina (Vitrebond - 3M ESPE) con el objetivo de disminuir el volumen final de resina compuesta y por consiguiente la contracción de polimerización, también actúa absorbiendo las tensiones de contracción de polimerización en función de su bajo módulo de elasticidad. Además de eso el cemento de ionómero de vidrio libera flúor y proporciona una mayor estabilidad a la interfase adhesiva debido a su menor coeficiente de expansión térmica lineal comparado al de las resinas compuestas (Franco 2003). El condicionamiento de los substratos fue realizado con ácido fosfórico al 37%, (Dental gel - Densply) por 30 segundos en esmalte y 15 en dentina. El sistema adhesivo (Adapter Single Bond – 3M ESPE) utilizado fue el convencional de 2 pasos y fueron seguidas las instrucciones del fabricante. Con las cavidades preparadas optamos por la elección de la resina Filtek Supreme (3M ESPE), con partículas nanométrica con tamaño medio de 20 nm y nanoaglomerados con tamaño medio de 6 µm. (Mitra 2003). Para disminuir las tensiones de contracción de polimerización fue realizada la técnica incremental en porciones de 2 mm de espesura en forma de conos, separadamente, sin unir las paredes vestibular y lingual, siguiendo las orientaciones de las cúspides correspondientes. El primer incremento de resina compuesta fue realizado con el color A 3 dentina (Filtek Supreme), luego con un pincel se procedió a colocar un tinte color ocre (Tetric color ochre – Ivoclar Vivadent) siguiendo los surcos de la restauración, un pigmento marrón (Tetric color médium-brown – Ivoclar Vivadent) en el surco principal, en las crestas de las cúspides fue utilizado un tinte de color blanco (Tetric color white – Ivoclar Vivadent) por último una resina color A 2 esmalte para dar mayor translucidez y forma final a la restauración. Cada camada de resina como de colorante fue polimerizada por 30 segundos. Después de la remoción del aislamiento absoluto se procedió al control de la oclusión eliminando los contactos prematuros. El pulido PAOR V o l 1 - n ° 1 44 de la restauración fue realizado con gomas abrasivas de diferente granulación (Enhance – Densply) y el brillo final con un cepillo con carburo de silicio integrado a sus fibras (Astrobrush – Ivoclar Vivadent). Finalmente fue aplicado un sellante de superficie, este procedimiento contribuye a rellenar pequeños defectos existentes en la interfase diente material restaurador, además fortalece y aumenta el tiempo de vida de la restauración. Figura 1 Restauraciones deficientes en el 3.6 y 3.7 Figura 2 Ataque con ácido fosfórico al 37% (Dental Gel – Densply) Figura 3 Paraguay Oral Research Figura 7 Aplicación de la resina compuesta color A 3 en forma de conos, siguiendo la orientación de las cúspides Figura 4 Aplicación del adhesivo con microbrush (Single bond – 3M ESPE) Figura 8 Aplicación de un tinte de color blanco (Tetric color white – Ivoclar Vivadent) en las crestas de las cúspides Figura 5 Un leve chorro de aire es utilizado para evaporar el solvente del adhesivo Figura 6 Fotopolimerización del adhesivo Figura 9 Aplicación de un tinte de color ocre (Tetric color ochre – Ivoclar Vivadent) en el surco para simular el color natural del diente . PAOR V o l 1 - n ° 1 45 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Secado de la cavidad con papel absorbente después de la aplicación de digluconato de clorhexidina al 2% por 1 minuto. Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Pulido de la restauración con gomas abrasivas (Enhance – Densply) Figura 10 Aplicación de una resina A 2 esmalte para dar forma final a la restauración en el 3.6 Figura 14 Pulido de la restauración con un cepillo especial (Astrobrush - Ivoclar Vivadent) Figura 11 Aplicación de una resina A 2 esmalte para dar forma final a la restauración en el 3.7 Figura 15 Restauración final Figura 12 Control de la oclusión Figura 13 . PAOR V o l 1 - n ° 1 46 índice de éxito de restauracione directas de 66% en 10 años y 47,8% en 15 años (Smales 1996). Un índice de retención del 88% después de 8 años, aumentando el índice de fracaso en pacientes mayores de 30 años. (Plasmans 1998). La mayor causa de fracaso era la fractura del diente restaurado (McDaniel 2000). Estudios laboratoriales de restauraciones extensas con resina compuesta directa indicaron que la falla en la interfase diente restauración es más probable que la falla del material (Kuijs 2003; Fennis 2005). Estos resultados demuestran la mejora de las propiedades físicas y mecánicas de las resinas compuestas en los últimos años lo que permite a los odontólogos realizar restauraciones más amplias con este material. En un estudio clínico (Pallesen 2003) después de 11 años de seguimiento no se encontró diferencia en el índice de fracaso entre restauraciones clase II realizadas con la técnica directa (17%) e indirecta (16%), otros autores (Swift 2001; Van Dijken 2000) encontraron resultados similares. Los sistemas de resinas compuestas para restauraciones indirectas también ganaron popularidad en los últimos años. Calor, presión y una atmosfera de nitrógeno pueden ser combinadas para lograr un mayor grado de polimerización y mejorar la resistencia al desgaste. No obstante, la composición química básica de las restauraciones indirectas de resina compuesta es similar a las de resina con la técnica directa. Las variaciones en las propiedades mecánicas son mínimas y no es de esperar diferencias clínicas significantes. (Swift 2001) Restauraciones cerámicas son más costosas y requieren técnicas más complicadas por lo tanto consumen mayor tiempo. El éxito de estas depende de la resistencia de la restauración cerámica por lo que es importante el diseño de la cavidad, forma de la restauración y su ajuste interno en la cavidad. En estas restauraciones el desgaste de la línea de cemento debe ser considerado, es por eso que un buen ajuste es fundamental para lograr la longevidad (Pallesen 2000). Thordrup y col. (2006) en un estudio clínico de 10 años de seguimiento no encontraron diferencia significativa entre restauraciones cerámicas y de resina compuesta con la técnica directa e indirecta en cavidades MOD. Los autores concluyeron que las inlays tuvieron un comportamiento clínico aceptable y el índice de éxito (80%) fue similar a las restauraciones directas de resina compuesta. Krujis y col (2006) en un estudio laboratorial en premolares observaron que restauraciones indirectas de cerámicas y resinas compuestas y resinas compuestas directas utilizadas en restauraciones extensas con pérdida de cúspides presentaron similar resistencia a la fatiga. En relación a la técnica, a la hora de realizar preparaciones para restauraciones indirectas, especial cuidado debe ser tomado para no desgastar estructura dental sana ya que muchas veces es difícil distinguir entre la restauración y el tejido dental por lo que se recomienda que este paso sea efectuado en forma minuciosa. En cavidades extensas la micro retención mecánica obtenida gracias a la técnica adhesiva en esmalte y dentina puede no ser suficiente para garantizar la estabilidad a largo plazo de la restauración, en estos casos macro retenciones pueden mejorar el desempeño de la restauración, preparos similares para onlays de porcelana o resina también están indicados debido a que proporcionan una mejor distribución de fuerzas oclusales (Mondelli 2008). Deliperi y Baedwell (2006) realizaron un estudio clínico en 25 restauraciones directas de resina compuesta en cavidades donde una o más cúspides necesitaban ser restituidas. Después de 30 meses ninguna falla fue observada. Es evidente que un mayor número de estudios clínicos con muestras mayores son necesarios para que este tipo de restauraciones tenga soporte científico, pero por los trabajos anteriormente citados podemos observar que existe una tendencia a extender las indicaciones de resinas compuesta con la técnica directa Conclusión La evolución de los sistemas restauradores adhesivos en los últimos años PAOR V o l 1 - n ° 1 47 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y Paraguay Oral Research están llevando a los clínicos a realizar restauraciones directas en cavidades cada vez más amplias. Mayor evidencia científica es necesaria para comprobar la duración de este tipo de restauraciones, no obstante, se hace evidente que estos materiales siguen evolucionando y tal vez estos sencillos procedimientos en dientes con gran pérdida de estructura sean de rutina en el futuro. Abstract Clinicians are looking for new materials and techniques to restore teeth with great lost of structure with a direct technique in vital and nonvital teeth. Improvements in physics and mechanics properties of new resin composites extend his indication to large restoration. The advantages of direct restoration are preservation of tooth structure and cost. They are studies supporting large restoration with direct resin composite, even though; most studies are needed to know longevity of these restorations. Dental material as resin composite are in constant evolution and maybe these kind of restoration will be of routine in the future. The objective of this study is to describe a restoration technique with resin composite of the 3.6 that present an old restoration that need to be change and include the restoration of one cuspid and the 3.7 that have a small restoration that also need to be change. Referencias 1- Bowen RL. Use of epoxy resins in restorative materials. J Dent Res 1956 jun; 35 (3): 360-9. 2- Fracci CE. Resinas compostas em dentes posteriores. In: Miyashita E. Trajano de Melo A. Odontologia estética planejamento e técnica. Cap 4 São Paulo, Artes médicas. 2006. 3- Nagem Filho, H. Materiais dentários Resinas compostas, 2º Ed. Bauru. Produções artes gráficas LTDA. 1999. 4- ADA Council On Scientific Affairs. Statement on posterior resin based composite. ADA Council on Dental PAOR V o l 1 - n ° 1 48 Benefit Program. J Amer Dent Assoc 1998;129:1627–8. 5- Hickel R, Manhart J. Longevity of restorations in posterior teeth and reasons for failure. J Adhes Dent 2001;3:45–64. 6- Van Meerbeek B, Vargas M, Inoue S, et al. Adhesives and cements to promote preservation dentistry. Oper Dent 2001;Supplement 6:119–44. 7- Hickel R, Manhart J, Garcìa Godoy F. Clinical results and new developments of direct posterior restorations. Am J Dent 2000;13:41D–54D. 8- Liebenberg WH. Assuring restorative integrity in extensive posterior resin restorations: pushing the envelope. Quintessence Int 2000;31:153–64 9- Deliperi S, Bardwell DN. Two-year clinical evaluation of non vital tooth whitening and resin composite restorations. J Esthet Restor Dent 2005;17:369–79. 10- Deliperi S, Bardwell DN, Coiana C. Reconstruction of devital teeth using direct fiber-reinforced composite resins: a case report. J Adhes Dent 2005;7:165–71 11- Mondelli J, Furuse AY, Benetti AR. Restauraçoes extensas de resina composta em dentes posteriores como alternativa ás inlays e onlays. In APCD 50 anos. 1º Ed. Sao Paulo. Editora Santos. 2008. 12- Franco EB, Lopes LG. Conceitos atuais na polimerizaçao de sistemas restauradores resinosos. Biodonto 2003; 1(2) 28-49. 13- Mitra SB, Wu D, Holmes, B. An apllication of nanotechnology in advanced dental materials. J Am Dent Assoc, Oct. 2003; 134 (10) 1382-90. 14- Shillingburg HT, Hobo S, Whitsett LD, et al. Fundamentals of fixed prosthodotics. Chicago (IL): Quintessence Publishing Books; 1997. Paraguay Oral Research three materials for cusp-replacing adhesive restorations. J Dent 2006;34:19–25. 26- Deliperi S, Bardwell DN. Clinical evaluation of direct cuspal coverage with posterior composite resin restorations. J Esthet Restor Dent. 2006;18(5):256-65 w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y w w w . p a r a g u a y o r a l .c o m . p y 15- Smales RJ, Hawthorne WS. Long-term survival and cost-effectiveness of five dental restorative materials used in various classes of cavity preparations. Int Dent J 1996;46:126–30. 16- Plasmans PJJM, Creugers NHJ, Mulder J. Long-term survival of extensive amalgam restorations. J Dent Res1998;77:453–60. 17- McDaniel JR, Davis RD, Murchison DF,Cohen RB. Causes of failure among cuspal coverage amalgam restorations: a clinical survey. J Amer Dent Assoc 2000;131:173–7. 18- Kuijs RH, Fennis WM, Kreulen CM, et al. Does layering minimize shrinkage stresses in composite restorations? J Dent Res 2003;82:967–71 19- Fennis WM, Kuijs RH, Barink M, et al.Can internal stresses explain the fracture resistance of cusp-replacing composite restorations? Eur J Oral Sci 2005; 113:443–8 20- Pallesen U, Qvist V. Composite resin fillings and inlays. An 11-year evaluation. Clin Oral Investig 2003;7:71–9 21- Swift EJ Jr. Processed composites. J Esthet Restor Dent 2001;13:284. 22- van Dijken JW. Direct resin composite inlays/onlays: an 11 year follow-up. J Dent. 2000 Jul;28(5):299306. 23- Pallesen U, van Dijken JWV. An 8-year evaluation of sintered ceramic and glass ceramic inlays processed by the Cerec CAD/CAM system. Eur J Oral Sci 2000;108:239–46. 24- Thordrup M, Isidor F, Horsted-Bindslev P. A prospective clinical study of indirect and direct composite and ceramic inlays: ten-year results. Quintessence Int 2006 Feb;37(2):13944. 25- Kuijs RH, Fennis WM, Kreulen CM, et al. A comparison of fatigue resistance of PAOR V o l 1 - n ° 1 49