CONFIGURACION MONOFASICA 2 POLOS 6, 10, 16, 20, 25, 32, 40
Transcripción
CONFIGURACION MONOFASICA 2 POLOS 6, 10, 16, 20, 25, 32, 40
Gama LED (H) UNIDAD DE PROTECCION AUTORREARMABLE CON MOTOR REARMADOR INTEGRADO. MODELOS RDI705H Y RDI105H (VERSION BORNAS TIPO U) CONFIGURACION MONOFASICA 2 POLOS 6, 10, 16, 20, 25, 32, 40, 50 Y 63A. L ENTRADA 230 V AC N NEUTRO L C1 IMPORTANTE: LA CONEXION DEL NEUTRO AL MAGNETOTERMICO COMO INDICA EL ESQUEMA (BORNA N) N C2 A B N L1 INPUT 1 POWER 230V~ CO NT RO L OU T ! EPXX Tele L CXX RDI 705H - Consult Manual Protection Unit I N 300 mA 1 ! G T L 1 COM L 2 SEN SOR 1 L ER CK TEST LOW VOLT I TI M BL O 30 0 N 2 ON Self Reclosing I m LT VO W I-ON LO I-ON A WORKING M 3 Reclosure RESET TEST OFF 1 ! 2 I N 3 4 5 6 7 8 9 AU XILIAR Y IN -OU T (C ON SU L T MAN U AL ) N VERSION BORNAS TIPO U CAUTION POSITION TRANSFORMADOR TOROIDAL DE INTENSIDAD DIFERENCIAL TRDF18 T CONSULT MANUAL G I T RDF18 RELE DE SALIDA CONMUTADO LIBRE DE POTECIAL CON FUNCION DE ACTIVACION POR ALARMA Y BLOQUEO BORNA Nº BORNAS AUXILIARY IN-OUT RELE DE SALIDA 5A MAX AC1 2 CONTACTO N/C RELE 3 CONTACTO COMUN RELE 2 3 4 RELE 4 CONTACTO N/O RELE ENTRADAS PARA CONTACTO EXTERNO LIBRE DE POTENCIAL CON FUNCION DE DESCONEXION, DESBLOQUEO Y PUESTA A CERO DE LA CUENTA DE DISPAROS BORNA Nº BORNAS AUXILIARY IN-OUT ENTRADAS REMOTE IN 8 ENTRADA REMOTE IN 9 ENTRADA REMOTE IN L BORNA BORNAS NO CONECTAR 1 BORNA NO CONECTAR 5 BORNA NO CONECTAR 6 BORNA NO CONECTAR 7 BORNA NO CONECTAR SALIDA 230 V AC N TRDF18: PASAR LOS CONDUCTORES FASE (L1) Y NEUTRO (N) POR EL ORIFICIO DEL TRANSFORMADOR TOROIDAL INDIVIDUALMENTE EMPAREJADO Y AJUSTADO PARA SU MODULO NO INTERCAMBIAR Y POSICIONARLO SEGUN SENTIDO FLECHA ! 28 CONSULTAR MANUAL DE INSTRUCCIONES Gama LED (H) UNIDAD DE PROTECCION AUTORREARMABLE CON MOTOR REARMADOR INTEGRADO. MODELOS RDI705H Y RDI105H (VERSION BORNAS TIPO R) CONFIGURACION MONOFASICA 2 POLOS 6, 10, 16, 20, 25, 32, 40, 50 Y 63A. L ENTRADA 230 V AC N NEUTRO L C1 IMPORTANTE: LA CONEXION DEL NEUTRO AL MAGNETOTERMICO COMO INDICA EL ESQUEMA (BORNA N) N C2 A B N L1 INPUT 1 POWER 230V~ C O NT RO L OU T ! EPXX Tele L CXX RDI 705H - Consult Manual Protection Unit I N 300 mA WORKING I-ON I-ON M W LO LT VO I 1 ! SENSO R 1 L CAUTION POSITION TRANSFORMADOR TOROIDAL DE INTENSIDAD DIFERENCIAL TRDF18 T T O BL 3 CK M TI Reclosure ER TEST LOW VOLT RESET TEST OFF I N AUX. ! 1 2 N CONSULT MANUAL G G 0 30 2 ON Self Reclosing I N A m I VERSION BORNAS TIPO R RELE DE SALIDA LIBRE DE POTECIAL CON FUNCION DE ACTIVACION POR BLOQUEO T RDF18 BORNA Nº AUX. RELE DE SALIDA 1A MAX AC1 BORNA NO CONECTAR 1 CONTACTO N/C RELE 2 CONTACTO COMUN RELE 1 BORNA Nº 2 Y 3, CONTACTO AUXILIAR NORMALMENTE CERRADO SE ABRE EN CASO DE ALARMA Y BLOQUEO L SALIDA 230 V AC N TRDF18: PASAR LOS CONDUCTORES FASE (L1) Y NEUTRO (N) POR EL ORIFICIO DEL TRANSFORMADOR TOROIDAL INDIVIDUALMENTE EMPAREJADO Y AJUSTADO PARA SU MODULO NO INTERCAMBIAR Y POSICIONARLO SEGUN SENTIDO FLECHA ! 29 CONSULTAR MANUAL DE INSTRUCCIONES 2 RELE