error contents
Transcripción
error contents
E R R O R C ON T EN T S 2. OUTDOOR UNIT LEDS (1) Stop the air conditioner operation. (2) Press the master control button and the fan control button simultaneously for 2 seconds or more to start the test run. When the outdoor temperature drops, the outdoor units fans may switch to low speed. ERROR : HEAT & COOL MODEL (REVERSE CYCLE) ONLY The LED lamps operate as follows according to the error contents. Error display LED1 Test run display LED2 0.1 s ec. (3) Press the start/stop button to stop the test run. ON OFF [SELF-DIAGNOSIS] ON OFF Quick flash continued When the error indication E:EE is displayed, follow the following items to perform the self-diagnosis. E:EE indicates an error has occurred. ON ON OFF OFF 2 s ec. 1 quick flash repeated 1) Stop the air conditioner operation. ON OFF 2 s ec. 2 quick flash repeated Error code ON OFF ON OFF 03 04 05 06 07 08 09 0A 0b 0c 0d 0E 0F 11 12 13 14 2004.08.02 Lighting continued 4 quick flash repeated Lighting continued Ex. Self-diagnosis simultaneously for 5 sec- 5 quick flash repeated Lighting continued 6 quick flash repeated Lighting continued 7 quick flash repeated Lighting continued Error contents Room temperature sensor open Lighting continued 2 s ec. 3 quick flash repeated 02 Discharge temperature sensor error 0.5 s ec. SU MO TU WE TH FR SA 00 01 Lighting continued ON OFF Unit number (usually 0) Communication error (indoor unit remote controller) Communication error (indoor unit outdoor unit) Power source connection error 0.5 s ec. 2) Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis. Refer to the following tables for the description of each error code. Error code Quick flash continued Model abnormal or EEPROM abnormal 0.5 s ec. 1. REMOTE CONTROLLER DISPLAY (3) Press the set temperature buttons onds or more to stop the self-diagnosis. Error contents 0.1 s ec. 8 quick flash repeated Lighting continued Outdoor heat exchanger temperature sensor error Outdoor temperature sensor error Communication signal error Indoor unit error Discharge temperature abnormal High pressure abnormal When the fault is cleared, the LED lamp goes off. However, for discharge pipe temperature abnormal and high pressure abnormal, the LED lamp lights continuously for 24 hours, as long as the power is not turned off. Room temperature sensor short-circuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor shortcircuited Outdoor heat exchanger temperature sensor open Outdoor heat exchanger temperature sensor shortcircuited Power source connection error Float switch operated Outdoor temperature sensor open Outdoor temperature sensor short-circuited Discharge pipe temperature sensor open Discharge pipe temperature sensor short-circuited Outdoor high pressure abnormal Discharge pipe temperature abnormal Model abnormal Indoor fan abnormal Outdoor signal abnormal Outdoor EEPROM abnormal www.enindel.com 8