x-fires™ 1000

Transcripción

x-fires™ 1000
X-FIRES™ 1000
Appliance Specifications
TM
Product Reference Information
Cat. #
Model
Ship. Wt.
Ship. Volume
H7222
X-FIRE-1000-NG
46 lb.
3.31 cu. ft.
H7223
X-FIRE-1000-LP
46 lb.
3.31 cu. ft.
X-Fires™ 1000
Catalytic Vent-free Fireplaces
Ratings
Input
NG = 5,110 - 8,870 BTU/HR
LP = 5,110 - 7,500 BTU/HR
Fuel
Natural Gas and Propane Gas
Venting
Ventless
(No Chimney Or Flue Required)
99.99%
Installation
Wall-Mounted
(Mounting Template Supplied)
Wall
Requirements
Any Wall Surface, Including
Combustible Surfaces
(Unit Can Not Be Recessed Into Wall)
Manual
Control
Manual Rotary Concealed Behind Glass
Inlet
Pressure
NG - Minimum 6” W.C.
LP - Minimum 11” W.C.
Ignition
Piezo
Safety
Features
O.D.S. - Oxygen Depletion Sensor
Minimum
Room Size
450 Cubic Feet*
Side
View
Front View
* Does not include any additional fuel burning appliances in the space. If you
have any additional gas burning appliances in the space, follow combustion and
ventilation air section from product installation instructions.
Listing
Information
POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL
COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED
FIXING POINTS
PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4
PUNTOS DE SUJECION
PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED
Clearance in
front of
heater 20”
Clearance to
combustible
sidewalls 4”
(both sides)
Note : Zero clearance from bottom of heater frame
required for hard combustible floors. Minimum 4”
clearance required to rugs or any fabric floor
coverings. REFER TO INSTRUCTION MANUAL
IMPORTANTE
ESTE APARATO UNICAMENTE DEBE SER
COLGADO EN UNA PARED.
NO EMPOTRE NINGUN ELEMENTO DE
ESTE APARATO.
ESTA PLANTILLA SIRVE UNICAMENTE
PARA MARCAR LOS PUNTOS DE FIJACION.
RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO.
IMPORTANT : Fabrics, curtains and drapes are not
permited above the heater at any distance and within
20” of the heater sides. No combustible shelves of any
size are permitted above the heater.
F860041/A
ADVERTENCIA
ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES
Deben mantenerse en todo momento los siguientes espacios
libres. El no hacerlo puede causar un riesgo de incendio.
Consulte el manual de instrucciones suministrado con este
aparato para obtener información completa.
El espacio de 32” hasta un techo
combustible se mide desde el borde
superior del panel de vidrio del aparato
Espacio libre
delante del
calentador 20”
CONCEALED
GAS INLET
ENTRADA DE
GAS OCULTA
Espacio hasta
paredeslaterales
combustibles
4” (ambos lados)
Nota: No se requiere espacio libre desde el borde inferior del
marco del calentador en caso de pisos combustibles duros.
Se requiere un espacio mínimo de 4” entre el calentador y
cualquier alfombra, moqueta o revestimiento de suelo de
tela. CONSULTE EL MANUAL DE INSTRUCCIONES.
IMPORTANTE: No se permite la colocación de telas, cortinas y
similares por encima del calentador a cualquier distancia, ni a
una distancia de 20” de los laterales del calentador. No se
permiten estantes combustibles de cualquier tamaño por
encima del calentador.
F860041/A
X-FIRES™ 1000
F860487 - ISSUE A - PRW
FocalPointFires Single
P/N 506035-06 REV. NC 07/2008
26/06/08
F860487 Lennox 1000 fitting template
Artwork Size: W1002 x H642
CONTORNO DE LA APARATO
This Lennox Hearth Products unvented gas room
heater is certified by
OMNI-Test Laboratories,
Inc to ANSI Z21.11.2
standard.
Portland
APPLIANCE OUTLINE
Clearance to combustible ceiling
32” measured from top of appliance
glass panel
IMPORTANT
THIS APPLIANCE IS TO BE WALL HUNG
ONLY.
DO NOT RECESS OR INSET ANY PART OF
THE APPLIANCE.
THIS TEMPLATE IS FOR THE MARKING
OF FIXING POINTS ONLY.
DO NOT INSTALL THE APPLIANCE WITH
THIS TEMPLATE IN PLACE.
FIREBOX OUTLINE
CONTORNO DE LA CAMARA DE COMBUSTION
CLEARANCES FROM COMBUSTIBLE MATERIALS
The following clearances must be maintained at all times.
Failure to do so may result in the risk of a fire.
For full information refer to the instruction manual
provided with the heater.
WALL MOUNTED VENT FREE FITTING TEMPLATE
PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS
CENTRE LINE
LINEA DE CENTRO
WARNING
6 3/8” (160mm)
8 13/16” (225mm)
15 3/4” (400mm)
31/8”
(78.6mm)
A FULL SIZE TEMPLATE IS SUPPLIED TO ASSIST WITH WALL MOUNTING
Efficiency
US
Report No. 317-F-10-5
Diagrams, illustrations
and photographs are not
to scale – consult installation instructions. Product
designs, materials, dimensions, specifications, colors and prices are subject
to change or discontinuance without notice.
Diagrams & Illustrations Are Not to Scale
Page 1 of 2
Combustible Clearances
X-FIRES™ 1000
Side Clearance To Combustibles: 4”
Side Clearance To Curtains, Drapes and Other Fabrics: 20”
Minimum Clearance To Ceiling Above Appliance: 32” (measured from
top of glass panel)
Clearance To Combustibles Placed Directly In Front Of Unit: 40”
Due to heat output, electronic appliances such as televisions, should
not be mounted on the wall above the unit
Approved for installation into bedrooms
Note: See installation instructions manual supplied with fireplace,
for specific installation details
39-7/16”
21-3/16”
39-7/16”
Fireplace and Surround Dimensions
21-3/16”
11-1/4”
21-7/16”
11-1/4”
25-1/4”
25-1/4”
4-1/2”
7-1/2”
4-1/2”
7-1/2”
15-3/4”
15-3/4”
23-3/4”
23-3/4”
X-FIRE-1000 Surround Kits
Cat. No.
Model
Ship. Wt.
Ship. Volume
H7226
X-FIRE-1000-L
Limestone Surround
55 lb.
4.58 cu. ft.
H7227
X-FIRE-1000-G
Granite Surround
55 lb.
4.58 cu. ft.
Printed in U.S.A. © 2008 by Lennox Hearth Products
P/N 506035-06 REV. NC 07/2008
Description
Page 2 of 2