x-fires™ 1000
Transcripción
x-fires™ 1000
X-FIRES™ 1000 Appliance Specifications TM Product Reference Information Cat. # Model Ship. Wt. Ship. Volume H7222 X-FIRE-1000-NG 46 lb. 3.31 cu. ft. H7223 X-FIRE-1000-LP 46 lb. 3.31 cu. ft. X-Fires™ 1000 Catalytic Vent-free Fireplaces Ratings Input NG = 5,110 - 8,870 BTU/HR LP = 5,110 - 7,500 BTU/HR Fuel Natural Gas and Propane Gas Venting Ventless (No Chimney Or Flue Required) 99.99% Installation Wall-Mounted (Mounting Template Supplied) Wall Requirements Any Wall Surface, Including Combustible Surfaces (Unit Can Not Be Recessed Into Wall) Manual Control Manual Rotary Concealed Behind Glass Inlet Pressure NG - Minimum 6” W.C. LP - Minimum 11” W.C. Ignition Piezo Safety Features O.D.S. - Oxygen Depletion Sensor Minimum Room Size 450 Cubic Feet* Side View Front View * Does not include any additional fuel burning appliances in the space. If you have any additional gas burning appliances in the space, follow combustion and ventilation air section from product installation instructions. Listing Information POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA NIVELAR LA PLANTILLA ANTES DE MARCAR LA PARED FIXING POINTS PIERCE TEMPLATE TO MARK HOLE POSITION ON WALL X 4 PUNTOS DE SUJECION PERFORE LA PLANTILLA PARA MARCAR LA POSICION DE LOS 4 TALADROS EN LA PARED Clearance in front of heater 20” Clearance to combustible sidewalls 4” (both sides) Note : Zero clearance from bottom of heater frame required for hard combustible floors. Minimum 4” clearance required to rugs or any fabric floor coverings. REFER TO INSTRUCTION MANUAL IMPORTANTE ESTE APARATO UNICAMENTE DEBE SER COLGADO EN UNA PARED. NO EMPOTRE NINGUN ELEMENTO DE ESTE APARATO. ESTA PLANTILLA SIRVE UNICAMENTE PARA MARCAR LOS PUNTOS DE FIJACION. RETIRE LA PLANTILLA ANTES DE COLOCAR LE APARATO. IMPORTANT : Fabrics, curtains and drapes are not permited above the heater at any distance and within 20” of the heater sides. No combustible shelves of any size are permitted above the heater. F860041/A ADVERTENCIA ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES Deben mantenerse en todo momento los siguientes espacios libres. El no hacerlo puede causar un riesgo de incendio. Consulte el manual de instrucciones suministrado con este aparato para obtener información completa. El espacio de 32” hasta un techo combustible se mide desde el borde superior del panel de vidrio del aparato Espacio libre delante del calentador 20” CONCEALED GAS INLET ENTRADA DE GAS OCULTA Espacio hasta paredeslaterales combustibles 4” (ambos lados) Nota: No se requiere espacio libre desde el borde inferior del marco del calentador en caso de pisos combustibles duros. Se requiere un espacio mínimo de 4” entre el calentador y cualquier alfombra, moqueta o revestimiento de suelo de tela. CONSULTE EL MANUAL DE INSTRUCCIONES. IMPORTANTE: No se permite la colocación de telas, cortinas y similares por encima del calentador a cualquier distancia, ni a una distancia de 20” de los laterales del calentador. No se permiten estantes combustibles de cualquier tamaño por encima del calentador. F860041/A X-FIRES™ 1000 F860487 - ISSUE A - PRW FocalPointFires Single P/N 506035-06 REV. NC 07/2008 26/06/08 F860487 Lennox 1000 fitting template Artwork Size: W1002 x H642 CONTORNO DE LA APARATO This Lennox Hearth Products unvented gas room heater is certified by OMNI-Test Laboratories, Inc to ANSI Z21.11.2 standard. Portland APPLIANCE OUTLINE Clearance to combustible ceiling 32” measured from top of appliance glass panel IMPORTANT THIS APPLIANCE IS TO BE WALL HUNG ONLY. DO NOT RECESS OR INSET ANY PART OF THE APPLIANCE. THIS TEMPLATE IS FOR THE MARKING OF FIXING POINTS ONLY. DO NOT INSTALL THE APPLIANCE WITH THIS TEMPLATE IN PLACE. FIREBOX OUTLINE CONTORNO DE LA CAMARA DE COMBUSTION CLEARANCES FROM COMBUSTIBLE MATERIALS The following clearances must be maintained at all times. Failure to do so may result in the risk of a fire. For full information refer to the instruction manual provided with the heater. WALL MOUNTED VENT FREE FITTING TEMPLATE PLANTILLA PARA LA INSTALACION DE CHIMENEAS DE PARED SIN SALIDA DE HUMOS CENTRE LINE LINEA DE CENTRO WARNING 6 3/8” (160mm) 8 13/16” (225mm) 15 3/4” (400mm) 31/8” (78.6mm) A FULL SIZE TEMPLATE IS SUPPLIED TO ASSIST WITH WALL MOUNTING Efficiency US Report No. 317-F-10-5 Diagrams, illustrations and photographs are not to scale – consult installation instructions. Product designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice. Diagrams & Illustrations Are Not to Scale Page 1 of 2 Combustible Clearances X-FIRES™ 1000 Side Clearance To Combustibles: 4” Side Clearance To Curtains, Drapes and Other Fabrics: 20” Minimum Clearance To Ceiling Above Appliance: 32” (measured from top of glass panel) Clearance To Combustibles Placed Directly In Front Of Unit: 40” Due to heat output, electronic appliances such as televisions, should not be mounted on the wall above the unit Approved for installation into bedrooms Note: See installation instructions manual supplied with fireplace, for specific installation details 39-7/16” 21-3/16” 39-7/16” Fireplace and Surround Dimensions 21-3/16” 11-1/4” 21-7/16” 11-1/4” 25-1/4” 25-1/4” 4-1/2” 7-1/2” 4-1/2” 7-1/2” 15-3/4” 15-3/4” 23-3/4” 23-3/4” X-FIRE-1000 Surround Kits Cat. No. Model Ship. Wt. Ship. Volume H7226 X-FIRE-1000-L Limestone Surround 55 lb. 4.58 cu. ft. H7227 X-FIRE-1000-G Granite Surround 55 lb. 4.58 cu. ft. Printed in U.S.A. © 2008 by Lennox Hearth Products P/N 506035-06 REV. NC 07/2008 Description Page 2 of 2