SOPRO Project Roundtable Nissan Motor Iberica
Transcripción
SOPRO Project Roundtable Nissan Motor Iberica
SOPRO Project Roundtable Nissan Motor Iberica Avila, Castilla y León, Spain 25th November 2009 SOPRO, Avila, 25 NOV'09 1 SOPRO Solar Process Heat Objectives • Trigger the starting-up of markets for solar process heat by carrying out targeted market development activities in 6 European Regions • Implement of 12 pilot projects (solar process heat installations) • Develop solar contracting for solar process heat Approach • Bringing togeather know-how from industrial processes, solar thermal and regional market development • Trans-sectorial approach (not limited to specific industrial sector/branches) SOPRO, Avila, 25 NOV'09 2 SOPRO Solar Process Heat Partnership • Regional partners: • O.Ö.Energiesparverband (Upper Austria) • ESCAN (Central Spain) • ECCB (South Bohemia, Czech Republic) • Gergtec (North-Rhine-Westphalia, Germany) • SAENA (Saxony, Germany) • ENERGAP (Podravje Region, Slovenia) • Scientific partners: • ISE technical & scientific support on solar thermal technologies • GERTEC technical & scientific support on industrial processes Project duration: 1-jun-2009 to 30-sept-2011 (28 months) SOPRO, Avila, 25 NOV'09 3 SOPRO Solar Process Heat Some main objectives • New pilot projects • Increased know-how of solar companies on industrial process • Incresased awareness of industrial decission makers • Increased uptake of solar contracting / ESCOs • Solar companies include process heat in their business portfolio SOPRO, Avila, 25 NOV'09 4 Por qué? Donde? INSTALACION TERMOSOLAR PARA PROCESO DE TÚNEL DE TRATAMIENTO (PREDESENGRASE, FOSFATADO, CATAFORESIS) Cómo? Cuanto? ÁVILA Real/ Expected Análisis 1 Por qué? Todas las plantas NISSAN tenemos los mismos indicadores de gestión los objetivos ambientales son los indicados en el Donde? Cómo? NISSAN PROGRAM GREEN 2007- 2010 Es un programa que fija objetivos ambientales para todas las plantas NISSAN del mundo desde el año 2007 al año 2010 hay tres indicadores fundamentales (“TRES CADENAS LIMPIAS”) Cuanto? porcentaje de reciclado de residuos Kgrs CO2/VEHÍCULO Real/ Expected Análisis Kgrs disolventes/m2 de superficie pintada Mensualmente todas las plantas reportamos la situación actual comparada con objetivo El objetivo perseguido fue la mejora del indicador de Kgrs CO2/veh 2 Por qué? CADENA LIMPIA 1 Reducción emisiones CO2 ÁVILA Donde? - 14% Ahorro periodo 2005 - 2010 CADENA LIMPIA 2 Aumentar % reciclado CADENA LIMPIA 3 Reducir emisiones VOC’s 73.9% (2005) Æ 85% (2010) 57 g/m² 2010 La instalación termosolar CED es una ayuda para la consecución de los Objetivos medioambientales de NMISA Planta de Ávila Cómo? Cuanto? Real/ Expected Análisis CARACTERÍSTICAS TÉCNICAS FOTOVOLTAICAS TÉRMICAS POTENCIA 103 kwp 370 kwp Nº PLACAS 480 252 ENERGÍA GENERADA 128.000 kwh/año 479.990 kwh/año EMISIONES CO2 EVITADAS 50 t CO2/año 217 t CO2/año 3 Por qué? Dónde Donde? Cómo? Se eligió la línea de pretratamiento de carrocerías porque en esta línea se consume energía calorífica generada en la sala de calderas usando agua a 110 ºC como portador y utilizando intercambiadores de calor Central térmica Linea de pretratamiento Cuanto? Real/ Expected Análisis La idea fue generar energía termosolar y transportarla hasta los intercambiadores de calor existentes en el proceso Dicho aporte de energía sería de apoyo, no de sustitución 4 Por qué? PREMISAS Donde? Cómo? Cómo? Cuanto? Localidad del emplazamiento ..................: Avila Provincia ....................................................: Avila Latitud ........................................................: 40º 38´ N Longitud .....................................................: 4º 50´ O Altura geográfica .......................................: 1126 m Temperatura media: invierno/verano ......: 2,5ºC/20ºC Radiación media …….................................: 3,99 kWh/m² dia Real/ Expected Análisis 5 Por qué? La instalación se compone de: Un sistema de captación formado por captadores que transforman la radiación solar incidente en energía térmica Donde? Un sistema de acumulación, constituido por dos depósitos de 20.000 litros que almacenan el agua caliente hasta que se precise su uso Cómo? Cómo? Un sistema de intercambio primario, que realiza la transferencia de energía térmica captada desde el circuito de colectores, o circuito primario, al agua caliente que se consume o circuito secundario. Cuanto? Un sistema de intercambio secundario, secundario que realiza la transferencia de energía térmica acumulada hacia las aplicaciones. Real/ Expected Un circuito hidráulico, constituido por tuberías, bombas, válvulas, etc., que conduce el fluido caliente desde el sistema de captación hasta el sistema de acumulación y desde éste a la red de consumo Análisis Un sistema de regulación y control, control que se encarga de asegurar el correcto funcionamiento del equipo 6 Por qué? Donde? Cómo? Cómo? Cuanto? Real/ Expected Análisis Captación/ Colectores Número de colectores 252 uds Superficie útil de captación total 252 x 2.1 = 529,2 m2 Número de baterías 42 uds Número de colectores por batería 6 uds Sistema de conexión baterías serie - paralelo Esta instalación está distribuida en dos dientes de sierra 7 Captación/ Colectores Por qué? Marca y modelo :GAMESA SOLAR 5.000ST Donde? Cómo? Cómo? Contraseña de homologación :NPS-4805 Dimensiones :1.050 x 2.120 x 86,2 mm Superficie útil de captación 2,1 m2 Cuanto? Real/ Expected Análisis Peso en vacío: 47 kg Volumen de agua contenido: 1,8 litros Presión máxima: 12 bar Caudal específico: 69 l/h m2 8 Sistema de acumulación Por qué? La producción de agua coincide con los periodos de mayor radiación solar, no así con el consumo, de ahí la necesidad de Donde? Cómo? Cómo? Cuanto? acumularla. Se han utilizado acumuladores de acero inoxidable de forma cilíndrica, siendo la altura mayor que el diámetro De esta manera, se favorece la estratificación. 2 depósitos acumuladores de 20.000 litros de capacidad conexionados en serie. Real/ Expected Análisis 9 Por qué? Sistema HIDRAÚLICO/ Tuberías, fluidos Donde? Las tuberías de todos los circuitos son de cobre con las uniones soldadas por capilaridad. Cómo? Cómo? Estan aisladas con aislamiento de elastómero térmico (20 mm interiores y 30 mm exteriores) y las que circulan por el exterior están protegidas contra los agentes atmosféricos, mediante pinturas adecuadas, papel kraft de aluminio reforzado con fibra de vidrio, chapa de aluminio Cuanto? FLUIDO DE TRABAJO Real/ Expected Para proteger el campo de colectores del riesgo de heladas se utilizará anticongelante etilenglicol en el circuito primario al 25 de concentración. Análisis 10 ESQU EMA D E PRINCIPIO P R IN C IP IO ESQUEMA DE Por qué? P IS C IN A C A T A F O R E S IS P IS C IN A PREDESENGRASE CUBA: 30 m 3 CUBA: 90 m 3 C ir c u it o d e a g u a s o b re c a le n t a d a IN T E R C A M B IA D O R C A T A F O R E S IS VA Donde? IN T E R C A M B IA D O R PREDESENGRASE C ir c u it o d e a g u a s o b r e c a le n t a d a P IS C IN A FOSFATADO V .C . CUBA: 90 m 3 ÀREA TO TAL PANELES 530 m 2 V .C . Cómo? Cómo? VA Sonda Tª VA VA 132 CO LECTORES GS 5000 ST IN T E R C A M B IA D O R FO SFATADO C o b re 2 " IN T E R C A M B IA D O R C A L E N T A M IE N T O F O S F A T A D O Y C A T A F O R E S IS (C ir c u it o d e c a le n t a m ie n to ) 4 0 °C - > 5 5 °C S1 AGUA + P R O P IL E N G R IC O L (3 5 % ) S11 S12 VA S13 VA VA IN T E R C A M B IA D O R F& C 324 Kw S14 VA IN T E R C A M B IA D O R PREDESENGRASE 186 Kw 120 CO LECTORES GS 5000 ST S9 Cuanto? S10 V1 C o b re 3 " V2 C o b re 3 " S8 S6 ~ 4 5 °C C o b re 3 " S4 S5 C o b re 3 " Real/ Expected ACUM ULADOR SOLAR 1 C o b re 3 " ~ 4 5 °C Cobre 3" S3 ACUM U LADO R SOLAR 2 2 0 .0 0 0 lt r s 2 0 .0 0 0 lt rs S2 B 1 .1 V a c ia d o B 1 .2 Q P R I M A R I O = 1 8 . 9 0 0 l /h C o b re 3 " V A S O D E E X P A N S IÓ N 1 d e 5 0 0 lt rs Q S E C U N D A R I O = 1 8 . 9 0 0 l /h B 2 .1 B 3 .1 B 2 .2 B 3 .2 Q APORTE SOLAR = 2 0 . 0 0 0 l/h C o b re 3 " FQ A S1 Análisis S3 S2 PSHL LSL S5 S4 S9 S6 S8 S11 S10 S13 S12 V a c ia d o S 14 P LC D E CO N TRO L IN S T . S O L A R LLENADO AF FQ A PSHL B11 B12 I SA S IC N IN SS N AMNO M T OORT IO BR É RIIB CÉ AR , S . AA. , S .A . - P L-P AN AV - IL A L TAAN D T EA ADVEI LA LSL B21 B22 B31 B32 V3V V1 V2 S IS T E M A D E L L E N A D O A U T O M Á T IC O C IR C U IT O S O L A R V A S O D E E X P A N S IÓ N 2 d e 5 0 0 lt r s C IR C U IT O S E C U N D A R IO C IR C U IT O P R E D E S E N G R A S E C IR C U IT O F O S F A T A D O Y C A T A F O R E S IS A .F . IN S T A L A C IÓ N S O L A R P L A N T A D E P IN T U R A F echa D ib u j a d o 2 7 - 0 9 - 0 7 C o m p rob . N o m b re P .C . F irm a s IN S T A L A D O R G a m e s a S o l a r & E L Y O I b é r ic a 11 Por qué? Donde? Cómo? Cómo? Cuanto? Real/ Expected Análisis 12 Por qué? Donde? Cómo? Cómo? Cuanto? Real/ Expected Análisis 13 Por qué? Donde? Cómo? Cómo? Cuanto? Real/ Expected Análisis 14 Por qué? Donde? Cómo? Cómo? Cuanto? Real/ Expected Análisis 15 Por qué? Investments: -TOTAL INSTALLATION COST: 279,930 € Donde? Cómo? Cuanto? Cuanto? Real/ Expected - CONTRIBUTION OF NISSAN: …………………………………….. 140.000 € - REST: - EREN: Grants from Local Authorities (Junta Castilla y León) 37% (103,861€) - ADE: Grants from Local Authorities (Junta Castilla y León) llegó al 50% - Fiscal deduction of the total investment for the first year, (deduction of the tax of societies quota). Análisis 16 PRESENTACIÓN DEL EREN. PROYECTO SO-PRO Jorge Jové Sandoval Jefe del Área Solar Dpto. de Energías Renovables Ente Regional de la Energía de Castilla y León (EREN) Ávila, 25 noviembre de 2009 ¿QUÉ ES EL EREN? El EREN es un Organismo de la Junta de Castilla y León encargado de establecer la política energética regional, fomentando el ahorro y la eficiencia energética y promoviendo las energías renovables. El año 2001 lanza el Plan Solar de Castilla y León con el objeto de generar mercado solar a largo plazo. El Plan se sustenta en las siguientes líneas de actuación: Plan Solar de CyL Difusión a los usuarios Formación a los instaladores Financiación de las instalaciones Acción Institucional MODELO DE NEGOCIO INSTALACIÓN SOLAR Compra Acción comercial Montaje Pago inversión Acción comercial INSTALADOR CLIENTE Compra ESE Contrata INSTALADOR Montaje CLIENTE € AHORRO TOTAL Amortización SUBVENCIÓN Pago energía Modelo nuevo (ESE): Modelo clásico (Instalador): € INSTALACIÓN SOLAR Precio energía ENERGÍA y AÑOS SUBVENCIÓN APOYOS INSTITUCIONALES - Promoción institucional: El EREN lleva más de 4 años vendiendo energía de origen solar térmico a los Hospitales del SACyL, prestaciones que pueden ser consultadas en su portal de internet. Esta actuación, Programa HOSPISOL, le ha valido el Premio Europeo 2008 al mejor proyecto de Servicios Energéticos en el Sector Público. www.eren.jcyl.es APOYOS INSTITUCIONALES El Programa Hospisol se inició en el año 2004 y hasta la fecha se han ejecutado 15 instalaciones en 14 Hospitales, con los siguientes resultados: 3.425 m2 instalados 1,8 M€ invertidos 3.193 camas afectadas 5.066.537 kWh (hasta 31/8/09) 438.322 € ahorrados APOYOS INSTITUCIONALES Actuación EST 3 - Financiación de las instalaciones: El EREN ha incluido desde el año 2009 ayudas a la ejecución de instalaciones mediante ESE. EST 4 EST 5 Actuación EST 3 Instalación por elementos con captadores solares cuyo coeficiente global de pérdidas es nferior o igual a 5 W/(m 2ºC) EST 4 Instalación por elementos con captadores solares cuyo coeficiente global de pérdidas es nferior a 9 W/(m 2ºC) y superior a 5 W/(m 2ºC) EST 5 Instalación por elementos con captadores solares con coeficiente global de pérdidas nferior a 4 W/(m 2ºC) EST 6 Estudios de viabilidad de instalaciones de energía solar térmica mediante ESE en edificios del sector terciario, industriales o de viviendas, salvo unifamiliares, de superficie de captación gual o superior a 40 m 2 Subvención (% coste subvencionable) Empresas No empresas 30% 40% 25% 35% 40% 50% 300 € con independencia de la superficie de captación total resultante del estudio (o 75% del coste laboral incurrido por la ESE). ≤ 8 m2 8 < X ≤ 20 m2 20 < X ≤ 50 m2 50 < X ≤ 70 m2 70 < X ≤ 100 m2 > 100 m2 ≤ 8 m2 8 < X ≤ 20 m2 20 < X ≤ 50 m2 50 < X ≤ 70 m2 70 < X ≤ 100 m2 > 100 m2 ≤ 8 m2 8 < X ≤ 20 m2 20 < X ≤ 50 m2 50 < X ≤ 70 m2 70 < X ≤ 100 m2 > 100 m2 Gasto subvencionable 1.000 €/m2 840 €/m2 790 €/m2 720 €/m2 670 €/m2 620 €/m2 900 €/m2 750 €/m2 700 €/m2 650 €/m2 600 €/m2 570 €/m2 1.140 €/m2 960 €/m2 900 €/m2 840 €/m2 770 €/m2 720 €/m2 EL EREN Muchas gracias por su atención Jorge Jové Sandoval Jefe del Área Solar Departamento de Energías Renovables Ente Regional de la Energía de Castilla y León www.eren.jcyl.es